INSTRUCTION MANUAL
POTENTIOMETER INPUT MODULE
(8 points, isolated, connector type) MODEL R3Y-MS8
BEFORE USE ....
Thank you for choosing us. Before use, please check con-
tents of the package you received as outlined below.
If you have any problems or questions with the product,
please contact our sales office or representatives.
■PACKAGE INCLUDES:
Potentiometer input module...............................................(1)
■MODEL NO.
Confirm Model No. marking on the product to be exactly
what you ordered.
■INSTRUCTION MANUAL
This manual describes necessary points of caution when
you use this product, including installation, connection and
basic maintenance procedures.
POINTS OF CAUTION
■CONFORMITY WITH EU DIRECTIVES
• The equipment must be mounted inside the instrument
panel of a metal enclosure.
• The actual installation environments such as panel con-
figurations, connected devices, connected wires, may af-
fect the protection level of this unit when it is integrated
in a panel system. The user may have to review the CE
requirements in regard to the whole system and employ
additional protective measures to ensure the CE conform-
ity.
■HOT SWAPPABLE MODULES
• Replacing the module does not affect other modules on
the same base. Thus, the module can be replaced while
the power is ON. However, replacing multiple modules
at once may greatly change live voltage levels. We highly
recommend to replace them one by one.
■GENERAL PRECAUTIONS
• DO NOT set the switches on the module while the power
is supplied. The switches are used only for maintenance
without the power.
■ENVIRONMENT
• Indoor use.
• When heavy dust or metal particles are present in the
air, install the unit inside proper housing with sufficient
ventilation.
• Do not install the unit where it is subjected to continuous
vibration. Do not subject the unit to physical impact.
• Environmental temperature must be within -10 to +55°C
(14 to 131°F) with relative humidity within 30 to 90% RH
in order to ensure adequate life span and operation.
■WIRING
• Do not install cables close to noise sources (relay drive
cable, high frequency line, etc.).
• Do not bind these cables together with those in which
noises are present. Do not install them in the same duct.
■AND ....
• The unit is designed to function as soon as power is sup-
plied, however, a warm up for 10 minutes is required for
satisfying complete performance described in the data
sheet.
INSTALLATION
Use the Installation Base (model: R3-BSx).
R3Y-MS8
EM-8956 Rev.6 P. 2 / 4
MG CO., LTD. www.mgco.jp
5-2-55 Minamitsumori, Nishinari-ku, Osaka 557-0063 JAPAN
COMPONENT IDENTIFICATION
■FRONT VIEW■SIDE VIEW
RUN LED
ERR LED
Input Connector
• Pin Assignment
B
20
A
20
B
1
A
1
ON
SW3
1
2
3
4
Conv.
Rate
■SIDE DIP SW
• Conversion Rate: SW3-1, 3-2
SW CONVERSION RATE
160 ms (*)80 ms 40 ms 20 ms
SW3-1 OFF ON OFF ON
SW3-2 OFF OFF ON ON
(*) Factory setting
Note: Be sure to set unused SW3-3 and 3-4 to OFF.
■STATUS INDICATOR LED
RUN indicator: Bi-color (red/green) LED;
Red when the bus A operates normally;
Green when the bus B operates normally;
Amber when both buses operate normally.
ERR indicator: Bi-color (red/green) LED;
Red with input abnormality;
Green in normal operating conditions.
PC CONFIGURATOR
With configurator software, settings shown below are available.
Refer to the software manual of R3CON for detailed operation.
■CHANNEL INDIVIDUAL SETTING
PARAMETER AVAILABLE RANGE DEFAULT SETTING
Zero Scale -32000 to +32000 0
Full Scale -32000 to +32000 10000
Zero Base 0 to 10000 0
Full Base 0 to 10000 10000
Unused 0: Enable
1: Disable
0: Enable
R3Y-MS8
EM-8956 Rev.6 P. 3 / 4
MG CO., LTD. www.mgco.jp
5-2-55 Minamitsumori, Nishinari-ku, Osaka 557-0063 JAPAN
TERMINAL CONNECTIONS
Connect the unit as in the diagram below.
■EXTERNAL DIMENSIONS unit: mm (inch)
130 (5.12)
27.5 (1.08) 110 (4.33) POSITIONING
GUIDE
R3Y-MS8
EM-8956 Rev.6 P. 4 / 4
MG CO., LTD. www.mgco.jp
5-2-55 Minamitsumori, Nishinari-ku, Osaka 557-0063 JAPAN
■CONNECTION DIAGRAM
INPUT 1
+
–
3
2
1
max.
min.
INPUT 2
+
–
3
2
1
POTENTIOMETER
max.
min.
INPUT 3
+
–
3
2
1
POTENTIOMETER
max.
min.
INPUT 4
+
–
3
2
1
POTENTIOMETER
max.
min.
INPUT 5
+
–
3
2
1
POTENTIOMETER
max.
min.
INPUT 6
+
–
3
2
1
POTENTIOMETER
max.
min.
INPUT 7
+
–
3
2
1
POTENTIOMETER
max.
min.
INPUT 8
+
–
3
2
1
POTENTIOMETER
max.
min.
INTERNAL POWER
INTERNAL BUS A
INTERNAL BUS B*
POTENTIOMETER
19B
18B
17B
15B
14B
13B
11B
10B
9B
7B
6B
5B
19A
18A
17A
15A
14A
13A
11A
10A
9A
7A
6A
5A
*For dual redundant communication.
BUS CONNECTOR
• Unused Input Channels
Close across the unused input terminals as shown below.
19B
18B
INPUT 1
15B
14B
INPUT 2
11B
10B
INPUT 3
7B
6B
17B 13B 9B 5B
INPUT 4
19A
18A
17A
INPUT 5
15A
14A
13A
INPUT 6
11A
10A
9A
INPUT 7
7A
6A
5A
INPUT 8
SHORT
SHORT
The input will become unstable if unused channels are left
open.
Unused channels can be specified and set so on the PC
Configurator Software (model: R3CON) without needing to
short at the field terminals.
INPUT CONNECTOR (40-pin)
PIN NO. ASSIGNMENT PIN NO. ASSIGNMENT
1A NC 1B NC
2A NC 2B NC
3A NC 3B NC
4A NC 4B NC
5A IN8C 5B IN4C
6A IN8B 6B IN4B
7A IN8A 7B IN4A
8A NC 8B NC
9A IN7C 9B IN3C
10A IN7B 10B IN3B
11A IN7A 11B IN3A
12A NC 12B NC
13A IN6C 13B IN2C
14A IN6B 14B IN2B
15A IN6A 15B IN2A
16A NC 16B NC
17A IN5C 17B IN1C
18A IN5B 18B IN1B
19A IN5A 19B IN1A
20A NC 20B NC

Other MG I/O System manuals

MG R7F4DC-DAC16C-H User manual

MG

MG R7F4DC-DAC16C-H User manual

MG Devicenet R7F4HD-DA32A User manual

MG

MG Devicenet R7F4HD-DA32A User manual

MG R7K4FML3-6-DC32A1 User manual

MG

MG R7K4FML3-6-DC32A1 User manual

MG R30BS User manual

MG

MG R30BS User manual

MG R7HL-YS4L User manual

MG

MG R7HL-YS4L User manual

MG M2BS2 User manual

MG

MG M2BS2 User manual

MG R7F4HD-DAC32C User manual

MG

MG R7F4HD-DAC32C User manual

MG M6DYV User manual

MG

MG M6DYV User manual

MG 10YS User manual

MG

MG 10YS User manual

MG Mini-M M2VV User manual

MG

MG Mini-M M2VV User manual

MG R7K4FML3-6-DA32-1 User manual

MG

MG R7K4FML3-6-DA32-1 User manual

MG R7I4DML3-DC32A User manual

MG

MG R7I4DML3-DC32A User manual

MG R7C-RT4A User manual

MG

MG R7C-RT4A User manual

MG R8-DAT8B2 User manual

MG

MG R8-DAT8B2 User manual

MG R8-DCT8B2 User manual

MG

MG R8-DCT8B2 User manual

MG R30XN16A User manual

MG

MG R30XN16A User manual

MG M2BS-16U0 User manual

MG

MG M2BS-16U0 User manual

MG R7F4DC-DC8A-J User manual

MG

MG R7F4DC-DC8A-J User manual

MG R8-FS16N User manual

MG

MG R8-FS16N User manual

MG Mini-M M2LMS User manual

MG

MG Mini-M M2LMS User manual

MG DLS-M1 User manual

MG

MG DLS-M1 User manual

MG DS-824 User manual

MG

MG DS-824 User manual

MG M2BS-8U1 User manual

MG

MG M2BS-8U1 User manual

MG R3-DA16 User manual

MG

MG R3-DA16 User manual

Popular I/O System manuals by other brands

SIGMA TEK DI 160 instruction manual

SIGMA TEK

SIGMA TEK DI 160 instruction manual

Control Technologies 2556-A Installation and operation guide

Control Technologies

Control Technologies 2556-A Installation and operation guide

Contec PIO-16/16L(CB)H user guide

Contec

Contec PIO-16/16L(CB)H user guide

SIGMA TEK DM 811 instruction manual

SIGMA TEK

SIGMA TEK DM 811 instruction manual

Contec ADI12-8(USB)GY user guide

Contec

Contec ADI12-8(USB)GY user guide

red lion PM-50 installation guide

red lion

red lion PM-50 installation guide

SignalFire Ranger900 manual

SignalFire

SignalFire Ranger900 manual

Contec FA-UNIT-M11BE quick start guide

Contec

Contec FA-UNIT-M11BE quick start guide

Delta DVP-SX instruction sheet

Delta

Delta DVP-SX instruction sheet

Fastwel DIC324 user manual

Fastwel

Fastwel DIC324 user manual

OneFex CS-IO1616 manual

OneFex

OneFex CS-IO1616 manual

Sony DSBK-130 operating instructions

Sony

Sony DSBK-130 operating instructions

Stahl IS1 manual

Stahl

Stahl IS1 manual

Siemens SIMATIC ET 200SP manual

Siemens

Siemens SIMATIC ET 200SP manual

9dot NCORE manual

9dot

9dot NCORE manual

Novus DIGIRAIL OEE user guide

Novus

Novus DIGIRAIL OEE user guide

Honeywell Excel 5000 open XFL521B Product data

Honeywell

Honeywell Excel 5000 open XFL521B Product data

Automationdirect.com Productivity 1000 P1-08NE3 manual

Automationdirect.com

Automationdirect.com Productivity 1000 P1-08NE3 manual

manuals.online logo
manuals.online logoBrands
  • About & Mission
  • Contact us
  • Privacy Policy
  • Terms and Conditions

Copyright 2025 Manuals.Online. All Rights Reserved.