manuals.online logo
Brands
  1. Home
  2. •
  3. Brands
  4. •
  5. MG
  6. •
  7. I/O System
  8. •
  9. MG R9WTU-ED User manual

MG R9WTU-ED User manual

EM-6225 Rev.3 P. 1 / 4
MG CO., LTD. www.mgco.jp
5-2-55 Minamitsumori, Nishinari-ku, Osaka 557-0063 JAPAN
INSTRUCTION MANUAL
DISCRETE I/O EXTENSION UNIT
(Di (internal power), Do (photo MOSFET relay), pulse totalizer)
MODEL
R9WTU-ED
BEFORE USE ....
Thank you for choosing us. Before use, please check con-
tents of the package you received as outlined below.
If you have any problems or questions with the product,
please contact our sales office or representatives.
■PACKAGE INCLUDES:
Discrete I/O extension unit.................................................(1)
Upper mounting adaptor ....................................................(2)
■MODEL NO.
Confirm Model No. marking on the product to be exactly
what you ordered.
■INSTRUCTION MANUAL
This manual describes necessary points of caution when
you use this product, including installation, connection and
basic maintenance procedures.
For detailed information of operation and configuration, re-
fer to the Instruction Manual of Multi Power Monitoring
Unit (model: R9xWTU).
POINTS OF CAUTION
■POWER CONSUMPTION
AC: < 2VA
DC: < 1.5W
■GENERAL PRECAUTIONS
• Before you remove or mount the unit, turn off the power
supply and input signal for safety.
■ENVIRONMENT
• Indoor use.
• Do not install the unit where it is directly exposed to rain,
water droplets or sunlight.
• When heavy dust or metal particles are present in the
air, install the unit inside proper housing with sufficient
ventilation.
• Do not install the unit where it is subjected to continuous
vibration. Do not subject the unit to physical impact.
• Environmental temperature must be within -10 to +55°C
(14 to 131°F) with relative humidity within 30 to90% RH
in order to ensure adequate life span and operation.
■WIRING
• Wiring to the unit must be conducted by qualified service
personnel.
• Do not install cables close to noise sources (relay drive
cable, high frequency line, etc.).
• Do not bind these cables together with those in which
noises are present. Do not install them in the same duct.
■AND ....
• The unit is designed to function as soon as power is sup-
plied, however, a warm up for 10 minutes is required for
satisfying complete performance described in the data
sheet.
R9WTU-ED
EM-6225 Rev.3 P. 2 / 4
MG CO., LTD. www.mgco.jp
5-2-55 Minamitsumori, Nishinari-ku, Osaka 557-0063 JAPAN
COMPONENT IDENTIFICATION
Terminal Block, Discrete Outputs
Output Status Indicator LED
Input Status Indicator LED
Terminal Block, Discrete inputs
COMCOM
DI1DI2
21
1110
COMCOM
DI3DI4
43
1312
COMCOM
DI5DI6
65
1514
COMCOM
DI7DI8
87
1716
NC
NC
9
18
NC
DO8
+
NC
DO8
-
89
1718
DO7
+
DO6
+
DO7
-
DO6
-
67
1516
DO5
+
DO4
+
DO5
-
DO4
-
45
1314
DO3
+
DO2
+
DO3
-
DO2
-
23
1112
DO1
+
DO1
-
1
10
■I/O STATUS INDICATOR LED
Discrete I/O extension units have LED indi-
cators showing I/O signal status.
Contact ON : LED ON
Contact OFF : LED OFF
TERMINAL ASSIGNMENTS
14
56
DI5
COM COM
15
DI6
16 17 18
789
DI7 DI8 NC
COM COM
10
12
DI1
COM COM
11
DI2
12 13
34
DI3 DI4
COM COM NC
ID ID
1 COM Input comon 10 DI1 Input 1ch
2 COM Input comon 11 DI2 Input 2ch
3 COM Input comon 12 DI3 Input 3ch
4 COM Input comon 13 DI4 Input 4ch
5 COM Input comon 14 DI5 Input 5ch
6 COM Input comon 15 DI6 Input 6ch
7 COM Input comon 16 DI7 Input 7ch
8 COM Input comon 17 DI8 Input 8ch
9 NC Unused 18 NC Unused
■DISCRETE INPUT
5
14 13
DO5–
DO5+ DO4+
4
DO4–
321
12 11 10
DO3– DO2– DO1–
DO3+ DO2+
9
18 17
NC
NC
DO8+
8
DO8–
76
16 15
DO7– DO6–
DO7+ DO6+ DO1+
ID ID
1 DO1– Output 1ch– 10 DO1+ Output 1ch+
2 DO2– Output 2ch– 11 DO2+ Output 2ch+
3 DO3– Output 3ch– 12 DO3+ Output 3ch+
4 DO4– Output 4ch– 13 DO4+ Output 4ch+
5 DO5– Output 5ch– 14 DO5+ Output 5ch+
6 DO6– Output 6ch– 15 DO6+ Output 6ch+
7 DO7– Output 7ch– 16 DO7+ Output 7ch+
8 DO8– Output 8ch– 17 DO8+ Output 8ch+
9 NC Unused 18 NC Unused
■DISCRETE OUTPUT
No.
FUNCTION FUNCTION FUNCTION FUNCTION
No. No. No.
INSTALLATION
■WALL MOUNTING
Attach the upper mounting adaptors to the upper side of
the unit, and pull out the lower mounting adaptors from the
lower side. Fasten a M4 screw through the mounting hole
(4.5 mm dia.) of each adaptor. (torque 1.4 N∙m)
To remove the upper mounting adaptor from the unit, pull
it out while squeezing the latches as shown in the figure
below.
push push
■DIN RAIL MOUNTING
Set the unit so that the lower mounting adaptors are at the
bottom. Hook the upper hook at the rear side of the unit
onto the DIN rail and push in the lower part of the unit.
When removing the unit, pull out the unit while pushing
down the adaptors using a minus screwdriver.
DIN Rail (35 mm wide)
Mounting Adaptor
R9WTU-ED
EM-6225 Rev.3 P. 3 / 4
MG CO., LTD. www.mgco.jp
5-2-55 Minamitsumori, Nishinari-ku, Osaka 557-0063 JAPAN
TERMINAL CONNECTIONS
Connect the unit as in the diagram below.
■EXTERNAL DIMENSIONS unit: mm (inch)
93 (3.66)
6 (.24) 36−M3 SCREW TERMINAL
126 (4.96)
122 (DIN RAIL MOUNT)
115 (4.53)
140 (5.51)
DIN RAIL
35 mm wide
2 − 4.5 (.18) dia. MTG HOLE
[4 (.16)]
6.5 (.25)
80 (3.15)7 (.28)
■CONNECTION DIAGRAM
LOAD
LOAD
U
1
10
1
10
Coil, etc.
Inductive loads
Varistor/CR Circuit
■Refer to the figure below for Photo MOS Relay discrete protection and noise removal.
•AC Powered• DC Powered
Coil, etc.
Inductive loads
Varistor/CR Circuit
Control
Circuit
10
1
DO1+
DO1–
17
8
DO8+
DO8–
Control
Circuit
Excitation Supply
1
10
8
17
+
–
1
5
10
2
6
4
7
13
8
14
12
15
11
16
17
COM
COM
COM
COM
COM
COM
DI2
DI1
DI3
DI4
DI5
DI6
DI7
DI8
■INPUT
COM
3
1
5
10
2
6
4
7
13
8
14
12
15
11
16
17
3
COM
DO6+
DO6–
DO7+
DO7–
DO8+
DO8–
DO1–
DO1+
DO2+
DO2–
DO3+
DO3–
DO4+
DO4–
DO5–
DO5+ COM
DI1
DI8
COM
DISCRETE
INPUT
DISCRETE
OUTPUT
■OUTPUT
EXTENSION CONNECTOR
R9WTU-ED
EM-6225 Rev.3 P. 4 / 4
MG CO., LTD. www.mgco.jp
5-2-55 Minamitsumori, Nishinari-ku, Osaka 557-0063 JAPAN
CONNECTING THE EXTENSION UNIT
1) Remove the cap.
2) Slide the two locks of the multi power monitoring unit to
the back position.
3) Connect the extension unit to the multi power monitor-
ing Unit.
4) Restore the two locks of the multi power monitoring unit
to the front position.
5) Mount the combined unit on a DIN rail.
Note: When you remove or mount the unit, turn off the power
supply and input signal for safety.
Lock
Cap
WIRING INSTRUCTIONS
■SCREW TERMINAL
Torque: 0.5 N·m
■SOLDERLESS TERMINAL
Refer to the drawing below for recommended ring tongue
terminal size. Spade tongue type is also applicable.
Applicable wire size: 0.25 to 1.65 mm2(AWG 22 to 16)
Recommended manufacturer: Japan Solderless Terminal
MFG. Co., Ltd, Nichifu Co., Ltd
6 (.24) max
3.3 (.13) max
mm (inch)

Other MG I/O System manuals

MG Mini-M M2LMS User manual

MG

MG Mini-M M2LMS User manual

MG R7K4FML3-6-DAC32B User manual

MG

MG R7K4FML3-6-DAC32B User manual

MG 10YS User manual

MG

MG 10YS User manual

MG R8-DCT8B2 User manual

MG

MG R8-DCT8B2 User manual

MG R7F4HD-DA32B User manual

MG

MG R7F4HD-DA32B User manual

MG R7F4DC-DC16A-H User manual

MG

MG R7F4DC-DC16A-H User manual

MG R3Y-MS8 User manual

MG

MG R3Y-MS8 User manual

MG M2BS-16U0 User manual

MG

MG M2BS-16U0 User manual

MG R1M-J3 User manual

MG

MG R1M-J3 User manual

MG R7HL-YS4L User manual

MG

MG R7HL-YS4L User manual

MG DS-824 User manual

MG

MG DS-824 User manual

MG R6N-SV2 User manual

MG

MG R6N-SV2 User manual

MG M6DYV User manual

MG

MG M6DYV User manual

MG 10FNS User manual

MG

MG 10FNS User manual

MG R5-SV1A User manual

MG

MG R5-SV1A User manual

MG M2BS2 User manual

MG

MG M2BS2 User manual

MG R7K4FML3-6-DC32B User manual

MG

MG R7K4FML3-6-DC32B User manual

MG Mini-M M2VV User manual

MG

MG Mini-M M2VV User manual

MG R8-DAT8B2 User manual

MG

MG R8-DAT8B2 User manual

MG R7F4HD-DAC32C User manual

MG

MG R7F4HD-DAC32C User manual

MG R7G4FML3-6-DC16A User manual

MG

MG R7G4FML3-6-DC16A User manual

MG M2BS-16U2 User manual

MG

MG M2BS-16U2 User manual

MG R7E-MS4 User manual

MG

MG R7E-MS4 User manual

MG R8-FS16N User manual

MG

MG R8-FS16N User manual

Popular I/O System manuals by other brands

National Instruments SCC-DI01 user guide

National Instruments

National Instruments SCC-DI01 user guide

M-system Devicenet R7F4DD-DA16A-C instruction manual

M-system

M-system Devicenet R7F4DD-DA16A-C instruction manual

Vexta EMP Series operating manual

Vexta

Vexta EMP Series operating manual

M-system R7ML-EA8 instruction manual

M-system

M-system R7ML-EA8 instruction manual

Elpro Technologies Condor ELPRO 415U-1-Cx Series Configuration manual

Elpro Technologies

Elpro Technologies Condor ELPRO 415U-1-Cx Series Configuration manual

ADLINK Technology cPCI-7300A user manual

ADLINK Technology

ADLINK Technology cPCI-7300A user manual

WAGO 750-438 manual

WAGO

WAGO 750-438 manual

WAGO 879-3001 (4PU) Operating and assembly instruction

WAGO

WAGO 879-3001 (4PU) Operating and assembly instruction

EasyIO 30P Frequently asked questions

EasyIO

EasyIO 30P Frequently asked questions

Johnson Controls M300MJ-4-20 Installation and maintenance instructions

Johnson Controls

Johnson Controls M300MJ-4-20 Installation and maintenance instructions

Acces I/O products ETH-IDIO-16 user manual

Acces I/O products

Acces I/O products ETH-IDIO-16 user manual

National Instruments sbRIO-9229 Operating instructions and specifications

National Instruments

National Instruments sbRIO-9229 Operating instructions and specifications

Siemens SIMATIC ET 200C manual

Siemens

Siemens SIMATIC ET 200C manual

DATAEAGLE Compact 2 Series Quick reference guide

DATAEAGLE

DATAEAGLE Compact 2 Series Quick reference guide

Easy Controls MC672 user manual

Easy Controls

Easy Controls MC672 user manual

Honeywell AUDZBX75 installation manual

Honeywell

Honeywell AUDZBX75 installation manual

Motorola Piccolo-XR owner's manual

Motorola

Motorola Piccolo-XR owner's manual

System Sensor M201E installation instructions

System Sensor

System Sensor M201E installation instructions

manuals.online logo
manuals.online logoBrands
  • About & Mission
  • Contact us
  • Privacy Policy
  • Terms and Conditions

Copyright 2025 Manuals.Online. All Rights Reserved.