manuals.online logo
Brands
  1. Home
  2. •
  3. Brands
  4. •
  5. MG
  6. •
  7. Transducer
  8. •
  9. MG 18RP User manual

MG 18RP User manual

EM-1867 Rev.1 P. 1 / 3
MG CO., LTD. www.mgco.jp
5-2-55 Minamitsumori, Nishinari-ku, Osaka 557-0063 JAPAN
INSTRUCTION MANUAL
BEFORE USE ....
Thank you for choosing us. Before use, please check con-
tents of the package you received as outlined below.
If you have any problems or questions with the product,
please contact our sales office or representatives.
■PACKAGE INCLUDES:
Signal conditioner ...............................................................(1)
■MODEL NO.
Confirm Model No. marking on the product to be exactly
what you ordered.
■INSTRUCTION MANUAL
This manual describes necessary points of caution when
you use this product, including installation, connection and
basic maintenance procedures.
POINTS OF CAUTION
■POWER INPUT RATING & OPERATIONAL RANGE
• Locate the power input rating marked on the product and
confirm its operational range as indicated below:
24V DC rating: 24V ±10%, approx. 80mA
■GENERAL PRECAUTIONS
• Before you remove the unit or mount it, turn off the power
supply and input signal for safety.
■ENVIRONMENT
• Indoor use.
• When heavy dust or metal particles are present in the
air, install the unit inside proper housing with sufficient
ventilation.
• Do not install the unit where it is subjected to continuous
vibration. Do not subject the unit to physical impact.
• Environmental temperature must be within -5 to +55°C
(23 to 131°F) with relative humidity within 30 to 90% RH
in order to ensure adequate life span and operation.
■WIRING
• Do not install cables close to noise sources (relay drive
cable, high frequency line, etc.).
• Do not bind these cables together with those in which
noises are present. Do not install them in the same duct.
■AND ....
• The unit is designed to function as soon as power is sup-
plied, however, a warm up for 10 minutes is required for
satisfying complete performance described in the data
sheet.
COMPONENT IDENTIFICATION
Body
Specifications
Front Cover
(Connection diagram
behind)
■FRONT VIEW (with cover open)
Span Adj.
Zero Adj.
1
78
56
2
34
INSTALLATION
Use Standard Rack (model: 18BXx or 18KBXx).
VAR TRANSDUCER MODEL 18RP
18RP
EM-1867 Rev.1 P. 2 / 3
MG CO., LTD. www.mgco.jp
5-2-55 Minamitsumori, Nishinari-ku, Osaka 557-0063 JAPAN
TERMINAL CONNECTIONS
Connect the unit as in the diagram below or refer to the connection diagram behind the front cover.
■EXTERNAL DIMENSIONS unit: mm (inch)
110 (4.33 )
93 (3.66)
24 (.94)
7 (.28)
78 (3.07)32 (1.26)
8–M3.5
SCREW
7 (.28)
2–M3
SCREW
■CONNECTION DIAGRAM
P2V
P1U
v
u
VT
P3
1L
1S
3L
3S
5
7
6
1
3
4
2
CONNECTOR
OUTPUT 1
OUTPUT 2
POWER
ll
LOAD
123
SOURCE
FUSE
k
CT
L
K
k
L
K
3-PHASE/3-WIRE
■
Vv
Uu
■TERMINAL ASSIGNMENTS
12
34
78
56
18RP
EM-1867 Rev.1 P. 3 / 3
MG CO., LTD. www.mgco.jp
5-2-55 Minamitsumori, Nishinari-ku, Osaka 557-0063 JAPAN
WIRING INSTRUCTIONS
■SCREW TERMINAL
Torque: 0.8 N·m
CHECKING
1) Terminal wiring: Check that all cables are correctly con-
nected according to the connection diagram.
2) Power input voltage: Check voltage supplied to the rack
(model: 18BXx or 18KBXx). For the DC power source, be
sure that the ripple level is within 10% p-p.
3) Input: Calculate the calibration range and check that the
result is within the usable range.
Calibration Range [var] = Measuring Range
(VT Ratio) × (CT Ratio)
4) Output: Check that the load resistance meets the de-
scribed specifications.
ADJUSTMENT PROCEDURE
This unit is calibrated at the factory to meet the ordered
specifications, therefore you usually do not need any cali-
bration.
For matching the signal to a receiving instrument or in case
of regular calibration, adjust the output as explained in the
following.
■HOW TO CALIBRATE THE OUTPUT 1
Use a signal source and measuring instruments of sufficient
accuracy level. Turn the power supply on and warm up for
more than 10 minutes.
1) ZERO: Apply 0% input and adjust output to 0%.
2) SPAN: Apply 100% input and adjust output to 100%.
3) Check ZERO adjustment again with 0% input.
4) When ZERO value is changed, repeat the above proce-
dure 1) – 3).
5) No need of adjustments for the Output 2.
MAINTENANCE
Regular calibration procedure is explained below:
■CALIBRATION
Warm up the unit for at least 10 minutes. Apply 0%, 25%,
50%, 75% and 100% input signal. Check that the output
signal for the respective input signal remains within accu-
racy described in the data sheet. When the output is out of
tolerance, recalibrate the unit according to the “ADJUST-
MENT PROCEDURE” explained earlier.
LIGHTNING SURGE PROTECTION
We offer a series of lightning surge protector for protec-
tion against induced lightning surges. Please contact us to
choose appropriate models.

Other MG Transducer manuals

MG L2PNA User manual

MG

MG L2PNA User manual

MG 18WT User manual

MG

MG 18WT User manual

MG LPAUN User manual

MG

MG LPAUN User manual

MG 17CE User manual

MG

MG 17CE User manual

MG LTWT User manual

MG

MG LTWT User manual

MG LTRPN User manual

MG

MG LTRPN User manual

MG 18PF User manual

MG

MG 18PF User manual

MG W2PV User manual

MG

MG W2PV User manual

MG MUWT User manual

MG

MG MUWT User manual

Popular Transducer manuals by other brands

Ametek 742R Operation, maintenance, and installation instructions

Ametek

Ametek 742R Operation, maintenance, and installation instructions

Simrad ES120-4X10 -  REV D datasheet

Simrad

Simrad ES120-4X10 - REV D datasheet

ESTERS ELEKTRONIK FMP 1836 instruction manual

ESTERS ELEKTRONIK

ESTERS ELEKTRONIK FMP 1836 instruction manual

Rishabh RISH CON - I operating manual

Rishabh

Rishabh RISH CON - I operating manual

Spectris HBM S2 Series Mounting instructions

Spectris

Spectris HBM S2 Series Mounting instructions

Thyracont VSM77PN operating instructions

Thyracont

Thyracont VSM77PN operating instructions

SonoSite L52 Series user guide

SonoSite

SonoSite L52 Series user guide

Simrad IS15 manual

Simrad

Simrad IS15 manual

Garmin Panoptix PS21-TR installation instructions

Garmin

Garmin Panoptix PS21-TR installation instructions

Induction Dynamics SolidDrive SD1 Installation & use guide

Induction Dynamics

Induction Dynamics SolidDrive SD1 Installation & use guide

Ashcroft CXLdp Installation sheet

Ashcroft

Ashcroft CXLdp Installation sheet

Thyracont VSP63MA4 operating instructions

Thyracont

Thyracont VSP63MA4 operating instructions

Panametrics C-RL instruction manual

Panametrics

Panametrics C-RL instruction manual

Balluff BTL266T user guide

Balluff

Balluff BTL266T user guide

Mountz BMX Series Operation instructions

Mountz

Mountz BMX Series Operation instructions

Mercury SMARTCRAFT WIRING CONNECTIONS

Mercury

Mercury SMARTCRAFT WIRING CONNECTIONS

HBK Z6 Mounting instructions

HBK

HBK Z6 Mounting instructions

MKS Baratron 223B instruction manual

MKS

MKS Baratron 223B instruction manual

manuals.online logo
manuals.online logoBrands
  • About & Mission
  • Contact us
  • Privacy Policy
  • Terms and Conditions

Copyright 2025 Manuals.Online. All Rights Reserved.