Microsensor Earth1006 User manual

V1.0
Earth1006
Operation Manual

I
CONTENTS
1 Introduction..........................................................................................................1
1.1 Brief introduction.....................................................................................1
1.2 Features....................................................................................................1
1.3 Basic parameters....................................................................................2
1.4 Outline dimension(Unit: mm)............................................................... 4
1.5 Panel structure........................................................................................ 4
1.6 Display...................................................................................................... 5
1.7 Key instruction.........................................................................................5
1.8 Interface....................................................................................................5
1.9 Application topology............................................................................... 6
1.10 Unpacking.............................................................................................. 7
1.11 Boot operation....................................................................................... 7
2 Detailed parameters..........................................................................................8
2.1 Power supply........................................................................................... 8
2.2 Display instruction.................................................................................. 9
2.3 Network mode....................................................................................... 11
2.4 Interface definition................................................................................12
2.4.1 Power interface......................................................................... 12
2.4.2 AI interface................................................................................. 14
2.4.3 DI/PI interface............................................................................ 15
2.4.4 RS485 communication interface........................................... 16
2.4.5 Camera interface...................................................................... 19

II
3 Device configurations..................................................................................... 19
3.1 configuration tool.................................................................................. 19
3.2 Local configuration method................................................................20
3.3 Remote configuration method........................................................... 21
3.4 Configuration options.......................................................................... 21
4 Installation instruction..................................................................................... 29
4.1 Installation tool...................................................................................... 29
4.2 Installation method, dimension and instruction............................. 29
4.2.1 Installation method................................................................... 29
4.2.2 Installation instruction.............................................................. 29
4.2.3 Installation dimension.............................................................. 30
4.3 SIM card installation............................................................................ 30
4.4 Device battery replacement............................................................... 32
4.5 Fixture..................................................................................................... 33
4.5.1 Underground installation examples...................................... 33
4.5.2 wall-mounting type....................................................................35
4.5.3 hoop-mounting type................................................................. 36
4.5.4 solar mounting type.................................................................. 37
5 Data platform instruction................................................................................ 38
6 FAQ.....................................................................................................................38
7 Responsibility................................................................................................... 41

III
Our company keeps the product technology and craftwork’s modification
rights. If the information were changed, no more notice would be edited.
Please pay attention to the latest introduction.
Our company keeps the final power of interpretation for this operation
menu.

1
Thank you for choosing the products from Micro Sensor Co., Ltd.
To better use this product, please read this operation manual
carefully before using.
1 Introduction
1.1 Brief introduction
Earth1006 Remote Monitoring Terminal is a compact device with battery
supply, ultra-low power consumption, IP68 protection, wireless
communication and various sensor data collection function, in specific
circumstance, multiple power supply options are available. It is suitable
for the monitoring fields without power supply condition and the harsh
environment. It could realize the multi-function including data collection,
storage, alarming and transmission for underground water, firefighting
water, dam water, water supply and drainage pipeline.
With a wide coverage of wireless network, the product could detect the
real-time data of many monitoring sites in a wide range of areas like
tap-water pipeline pressure, flow, underground water, agricultural
irrigation, dam level, water monitoring, wind, rain, ambient temperature
and humidity, air quality monitoring, water flow monitoring, image and
firefighting pipeline monitoring, especially suitable for Underground Well
detection application in a harsh environment.
1.2 Features
•IP68 protection--dust-proof and water-proof
•Variety of power supply optional and with ultra-low power

2
consumption
•Integrated battery with 3~5 years’ lifespan
•Wireless transmission, no field wiring
•Multi-parameter including pressure, temperature, level, flow, image
and manhole cover motoring
•Multi-channel with max. 8-way sensor access
•Remote configuration for collection, transmission and image
interval
•Remote configuration for upper and lower alarm limit and web
real-time warning
•PC and mobile terminal data application
•Support customer self-built system and configuration application
•Equipped with installation accessories
•Solution for underground pipe-network and pipe rack
1.3 Basic parameters
Power supply
Mode: battery/solar power/12~28V DC/110~240V AC
Consumption: sleeping current ≤30uA@14.4V
Transmission average current ≤40mA@14.4V
Interface
Interface type: 3-way AI, 2-way DI/PI,1-way RS485,1-way Camera
Data transmission
Communication mode: 2G/Multi-Bands/NB-Iota/LoRa

3
Wake-up mode: magnetic activation/timing/alarm wake-up
Sampling interval: 1,5,10,30,60,360,720,1440 minutes optional,
alarms are given at the intervals, and maximum 3 times warning can
be sent over each interval to ensure longer battery life.
Transmission interval: 1,5,10,30,60,360,720,1440 minutes optional
Image interval: 30,60,720,1440 minutes optional
Upload information: sensor data, battery information, network status,
self-check information
Data storage
Local storage: Flash 4MB (more than 200,000 history data)
Configuration
Configuration mode: local/remote configuration
Display
Segment LCD, with backlight
Environmental condition
Working temperature: -20℃~70℃
Storage temperature: -40℃~85℃
Others
Protection: IP68 (work normally for 72 hours at 1m below the water)
Housing material: PA6+30%GF
Installation method: wall-mounting, hoop-mounting
Outline dimension: 147×262.5×105.5mm

4
Weight: about 2.3kg
Accessory: magnetic bar*1, fixed support*1, M5 bolt*1, ф8mm
expansion bolt*3, ф200mm hoop *2
1.4 Outline dimension(Unit: mm)
1.5 Panel structure
Note:
1-mounting hole
2-magnetic control key
3-display screen
4-fool-proof interface
5-operation instruction

5
1.6 Display
1.7 Key instruction
Keys need to use the matching magnetic bar to operate, when the
magnetic bar close to or gently click the magnetic control key, Earth1006
Remote Monitoring Terminal will come into the key operation.
Off state (key induces 1s and the screen is not lit), key induces 8s, the
device boot;
Boot state, the key induces 1s, the screen lit;
When the screen is bright, the key induces 1s flip;
When the screen is bright, the key induces 8s off.
1.8 Interface
Table 1.1 Device interface
Type
AI
DI/PI
RS485
Camera
Qty.
3
2
1
1
Signal
0V~5V DC/
4mA~20mA
DC
Switch/pulse
ModBus RTU
Pictures only, video
transmission not
available
┄Device status
┄Channel NO./unit
┄Channel value/alarm

6
Remark
Collection
accuracy
±0.5%FS
Input current
≤30mA
Low level
0V~1V DC
High level
5V~12V DC
Pulse
frequency
≤10Hz
Support
max.3-way
sensor parameter
analysis and also
be used for device
configuration
RS485
1.9 Application topology

7
1.10 Unpacking
Table 1.2 packing list
No.
Item
Qty.
Remark
1
Earth1006 Remote Monitoring
Terminal
1 set
2
Magnetic bar
1pc
3
Hanging bracket
1set
Including fixed bolt
4
Expansion screw
3pairs
Wall mounted
5
Stainless steel hoop
2pcs
Stud mounted
6
Configuration line
1pc
1pc for each batch
7
Operation manual
1pc
8
Certification
1pc
After unpacking, please check carefully according to above list. The
specific quantity shall be consistent with the customer order contract. If
there is damage, loss, shortage or discrepancies of accessories, please
contact the manufacturer in time.
1.11 Boot operation
After receiving the product, please connect different interface sensor,
with more than 8s magnet induction magnetic control buttons, powered
on, the screen lit, entered the work flow, subsequent parameters
configuration can be remote, as shown in the device configuration.

8
2 Detailed parameters
2.1 Power supply
The power parameters are shown in table 2.1.
Table 2.1 power parameters
Power Supply
Non-rechargea
ble Battery
Rechargea
ble Battery
DC
Power
AC
Power/12VDC
Adapter
Solar
Power
Battery
Capacity
(See description
on label
/Nameplate)
20Ah/12V
12VDC
110V~240V
AC
50/60Hz
20 Ah/12V
Solar Panel:
12V/20W
Battery
Lifetime
3~5 years
(Related to
transmission
frequency)
Longer than
1
month(Relat
ed to
transmission
frequency)
\
\
More than 1
month
(Related to
Transmissio
n
frequency )
Feed
100mA/14.4V
DC
100mA
/12VDC
100mA
/12V DC
100mA
/12V DC
100mA
/12V DC
Power
Consumption
Sleep Current ≤30uA/14.4V
Transmission Average Current ≤50mA/14.4V

9
2.2 Display instruction
The screen display parameters are shown in table 2.2.
Table 2.2
Icon name
Meaning
Details
Signal
Wireless
signal
strength
indicator
≥25 full green
≥15 green for 3 bars
≥10 green for 2 bars
<10 green for 1 bar
0 null / signal tower icon only
SIM card
Card status
No card/unrecognized card
Configuration
Configuration
mode
When the configuration icon is lit, it
enters the configuration mode and the
device stops the data transmission.
Collection
Sensor data
collection
Collect sensor data regularly, the icon
lights, the device external feed, the
battery ┆
Photograph ┆
transmission ┆
collection ┆
configuration ┆
SIM card ┆
signal ┆
┄device status
┄channel NO./unit
┄channel value/alarm

10
sensor work
Transmission
Data
interaction
The device is communicating with the
server requesting the data.
Photograph
photograph
Taking photo/photo data acquisition
Battery
Power
indicator
Non-recharge
able battery
≥95% Full Green
≥85% 3 Green Bars
≥75% 2 Green Bars
≥65% 1 Green Bar
﹤65% Empty
12V DC
/110V~240V
AC
Adapter Icon displayed
on web.
Battery shows full on the
displayer
Rechargeable
Battery/Solar
power
≥95% Full Green
≥85% 3 Green Bars
≥75% 2 Green Bars
≥65% 1 Green Bar
<65% Empty
Channel NO.
Distinguish
between
different
sensor
channels
CH1~CH3: analog channel
CH4~CH6: RS485 channel
CH7~CH8: DI/PI
Unit
Sensor type
Pressure: kPa, MPa:
Temperature: ℃,℉:
Height: cm, m

11
Flow: cm³, m³
Flow rate: cm³/h, m³/h
Humidity: %RH
User defined: xxx
Channel value
Real-time
value of
sensor
Alarm
Alarm status
reminder
over the upper limit of channel
threshold
below the lower limit of channel
threshold
2.3 Network mode
Table 2.3 network mode
Communicati
on mode
Zone
Standard/Frequency bands
2G
Global bands
GSM 850/900/1800/1900MHz
Multi-Bands
China
TDD-LTE B38/B39/B40/B41
FDD-LTE B1/B3/B8
TD-SCDMA B34/B39
WCDMA B1
CDMA 1X/EVDO BC0
GSM/GPRS/EDGE B3/B8

12
EMEA/Korea/
Thailand/India
FDD-LTE B1/B3/B5/B7/B8/B20
WCDMA B1/B5/B8
GSM/GPRS/EDGE B3/B8
North America
FDD-LTE B2/B4/B12
WCMDA B2/B5
South America/
Australia/
New Zealand /
Tai Wan
TDD-LTE B40
FDD-LTE
B1/B2/B3/B4/B5/B7/B8/B28
WCDMA B1/B2/B5/B8
GSM/GPRS/EDGE B2/B3/B5/B8
Japan
FDD-LTE B1/B3/B8/B18/B19/B26
NB-IoT
Global bands
B1/B3/B8/B5/B20/B28
LoRa
433/470/868(Europe) /915(USA)
MHz transmission distance≤5km
(According to site environment)
2.4 Interface definition
All interfaces of Earth1006 are foolproof plug and each electrical
definition has different PIN number, please pay attention to checking.
2.4.1 Power interface
The power interface corresponds to 2PINS terminal, the definition of
interface is shown in Table 2.4.

13
Table 2.4 power interface
Interfa
ce type
Termin
al type
Power
supply
Pin
Defin
ition
Details
Note
Power
2PINS
Recharg
eable
battery/s
olar
power/12
VDC
1
VCC
Supply +
/solar
panel +
Non-rechargea
ble Battery has
no power
interface.
2
GND
Supply -
/solar
panel -
110V~24
0V AC
50~60Hz
1
L
AC L
Please pay
attention to
checking the
power supply
identification in
case of any
possible safety
accidents
2
N
AC N
Electrical
connection

14
2.4.2 AI interface
AI interface corresponds to 5PINS terminal and there are 2-wire and
3-wire. The definition is shown in table 2.5.
Table 2.5 AI interface
Interfac
e type
Terminal
type
Pin
Definiti
on
Details
Note
AI
5PINS
5
AGND
Common port
feed≤100mA
1
Vo
feed
2
AI1
Analog input 1
0V~5V DC/
4mA~20mA DC
Input
current≤30mA
AI2
Analog input 2
AI3
Analog input 3
2-wire electrical
connection(4~20mA)
3-wire electrical
connection(0~5VDC)

15
Channel Value
When there is no load, the current type channel value =
range ÷(-4), for example, when the range is 2 MPa,
the channel value is -0.250, and the voltage type
channel value = random value.
Note
If the equipment has three 5-PIN terminals, they are
three separated AI ports, which can connect with three
different sensors. But the AI interfaces are
standard-alone interfaces, cannot be extended by using
the external junction box. Different types of sensor
channels can be distinguished based on the labels.
2.4.3 DI/PI interface
DI/PI interface corresponds to 4PINS terminal and the definition is shown
table 2.6.
Table 2.6 DI/PI interface
Interfa
ce type
Termin
al type
Pin
Definition
Details
Note
DI/PI
4PINS
4
DGND
Common port
feed≤100mA
1
Vo
feed

16
2
DI1/PI1
Switch 1/
pulse 1 input
Low level 0~1V DC
High level 5~12V
DC
Pulse
frequency≤10Hz
3
DI2/PI2
Switch
2/pulse 2
input
electrical
connection
Channel Value
DI: At low level, the channel value is 0; at high level, the
channel value is 1.
When the * MST071 shift switch is raised (well cover
change), it turns on and outputs the high level.
PI: The channel value is 0.
Note
If the device has only one 4-PIN terminal, it can only
connect with one sensor as default, but if two channels are
required, exterior connection box would be necessary.
2.4.4 RS485 communication interface
RS485 interface corresponds to 7PINS terminal and the definition is
shown in table 2.7.
Table of contents
Popular Touch Terminal manuals by other brands

Unitech
Unitech MR350 MKII Technical reference manual

Siemens
Siemens SIMOTION TM15 manual

3M
3M Dynapro ET 3170 Terminal Series B installation guide

Datalogic
Datalogic F734-E Series Brochure & specs

VeriFone
VeriFone K250 Extended installation guide

Allen-Bradley
Allen-Bradley MobileView 2711T-B10R1K1 Product information