Middle Atlantic Products FlexView FVS Series User manual

FlexView™
FVS Series Electric Lift
Instruction Sheet
PRODUCT FEATURES
Thank you for purchasing the FlexView™ FVS Series Electric Lift. Please read these instructions
thoroughly before installing this product.
THANK YOU
• Middle Atlantic PD-815SC (8) outlet, 15 amp power strip with surge and circuit breaker
• Simple display mounting with electric adjustment of monitor height
• Lever Lock™ for easy mounting of Codecs and smaller components
• Adjustable cable management included
I-00669 Rev -

IMPORTANT SAFETY INSTRUCTIONS
Page 2
WARNING/CAUTION! The exclamation point within an
equilateral triangle is intended to alert the user to the
presence of important operating and maintenance
(servicing) instructions in the literature accompanying the
appliance
AVERTISSEMENT/ATTENTION! Le point d'exclamation
dans un triangle équilatéral est destiné à alerter l'utilisateur
de la présence d'importants instructions d’opération et de
maintenance (entretien) dans la documentation
accompagnant l'appareil.
!
!
WARNING! Failure to read, understand and follow the
following information can result in serious personal injury,
damage to the equipment or voiding of the warranty. It is
the responsibility of the Installer/User to ensure
that this product is loaded according to specifications.
AVERTISSEMENT! Refus de lire, comprendre et suivre
la renseignements suivants peut traduire par de graves
blessures, des dommages à l'équipement ou invalider la
garantie. Il est la responsabilité de l'installateur / utilisateur
de s'assurer que ce produit est chargé conformément aux
spécifications.
AVERTISSEMENT! Les caractéristiques de poids de ce
produit peuvent être trouvées sur le produit. Le
dépassement de ces caractéristiques de poids peut
entraîner des blessures graves ou des dommages
à l'équipement. C'est l'responsabilité de l'installateur /
utilisateur de s'assurer que les composants installé ne
dépassent pas les notes de poids comme un instable
condition peut se produire qui peut causer des blessures
ou dommages.
!
!
!
!
CAUTION! To avoid an unstable condition, place heavier
components at the bottom of the cabinet. When more than
one component is placed in the cabinet, begin at the
bottom of the cabinet and place equipment at the lowest
available point, evenly distribute weight (vertically) within
the cabinet.
ATTENTION! Pour éviter une condition instable, placer
des composants plus lourds dans le bas de l'armoire.
Lorsque plus d'un composant sera placé dans l'armoire,
commencez en bas de l'armoire, placent l'équipement sur
le point le plus bas disponible, distribuant uniformément le
poids (verticalement) dans l l'armoire.
!
!
WARNING! For use with televisions weighing 175lbs
(79 Kg) or less. Use with heavier televisions may
result in instability causing tip over resulting in death
or serious injury.
AVERTISSEMENT - Pour utilisation avec des téléviseurs
pesant 175 lbs (79 kg) ou moins. Utilisation avec des
téléviseurs plus lourds peut provoquer une instabilité
entraînant l’unité a basculer, que peut causer la mort ou
des blessures graves.
!
!
WARNING! Relocating audio and/or video equipment to furniture
not specifically designed to support audio and/or
video equipment may result in death or serious injury due to
the furnishing collapsing or over turning onto a child.
AVERTISSEMENT - Déplacement de l’équipements audio et /
ou vidéo sur des meubles pas conçu spécifiquement à soutenir
l'équipement audio et / ou vidéo peuvent entraîner la mort ou
des blessures graves cause par l’effondrement du meuble ou
en basculant sur un enfant.
!
!
WARNING! Death or serious injury may occur when children
climb on audio and/or video equipment furniture. A remote control
or toys placed on the furnishing may encourage a child to climb
on the furnishing and as a result the furnishing may tip over on to
the child.
AVERTISSEMENT - Mort ou blessures graves peuvent se
produire lorsque les enfants montent sur des meubles pour
l'audio et / ou vidéo. Une télécommande ou des jouets mis sur
le mobilier peuvent encourager un enfant à grimper sur le
meuble, provoquant une instabilité et entraînant l’unité a basculer
sur l'enfant.
!
!
•Clean only with dry cloth
Nettoyer avec un chiffon sec seulemen
WARNING! The weight ratings of this product can be
found on the product. Exceeding these weight ratings can
result in serious injury or damage to the equipment. It is the
responsibility of the Installer/User to ensure the components
installed do not surpass the weight ratings as an unstable
condition can occur which may cause possible injury or
damage.

Important Safety Instructions Page 2
Weight Ratings Page 4
Tools Required Page 4
Mobility Features Page 4
Operation Page 4
Hardware / Items Supplied Page 5
Flat Panel Installation Page 6
Vesa 800 Extension Bracket Installation (If Required) Page 7
Flat Panel Installation (Continued) Page 7
Flat Panel Installation (Continued) Page 8
Flat Panel Installation (Continued) Page 9
Door Reversal Procedure Page 10
Lever Lock™Tool Free Internal Management System Page 11
Cable Management / Equipment Mounting Page 12
Page 3
TABLE OF CONTENTS

• #2 Phillips Screwdriver
• Protective Eyewear
• Adjustable Wrench
• 1/2” Socket
• 7/16” Socket
ITEM
Screen
Screen (Including Camera Mount and Soundbar Mount)
Internal
Total Rated Load
DETAILS
175 lbs. (79.4 kg) Maximum
190 lbs. (86.2 kg)
Maximum
50 lbs. (23 kg) Maximum
240 lbs. (109 kg) Maximum
• Leveling feet are provided to level the unit as needed.
• (4) Optional directional locking casters are available
to allow easy “steering” of unit in locked direction.
Page 4
WEIGHT RATINGS
MOBILITY FEATURES
TOOLS REQUIRED
OPERATION
DURING OPERATION:
• IF THE FLEXVIEW MAKES UNUSUAL NOISE OR SMELLS, SWITCH OFF THE MAINS VOLTAGE IMMEDIATELY.
• TAKE CARE THAT THE CABLES ARE NOT DAMAGED.
• UNPLUG THE MAINS CABLE ON MOBILE EQUIPMENT BEFORE IT IS MOVED.
Move
Up
Move
Down
To prevent FlexView from
moving, lock casters
perpendicular to each
other as shown
NOTE: Push levers to lock, lift levers to unlock.

NOTE: Additional hardware is included
that may not be required for your installation.
Page 5
HARDWARE/ITEMS SUPPLIED
Thread Depth Indicator
(Qty 1)
5/16” Flat Washers
(Qty 10)
M5 x 12 (Qty 8)
M6 x 12 (Qty 8)
M4 x 16 (Qty 8)
(Qty 6)
M5 x 16
(Qty 6)
M5 x 20
M6 x 20 (Qty 6)
M8 x 20 (Qty 6)
(Qty 4)
M4 x 25
(Qty 4)
M5 x 25
M8 x 25 (Qty 6)
M8 x 30 (Qty 6)
M8 x 35 (Qty 4)
(Qty 8)
M5 x 50
M8 x 70 (Qty 4)
Universal Washers
(Qty 8)
Level
(Qty 1)
1/4” Large Nylon Spacers
(Qty 6)
1/2” Large Nylon Spacers
(Qty 12)
1” Nylon Spacers
(Qty 6)
1/4” Small Nylon Spacers
(Qty 6)
Nylon Spacers
(Qty 4)
1/2” Small Nylon Spacers
(Qty 6)
5/16”-18 Hex Head
Monitor Mount Bolts
(1/2” Socket Req’d)
(Qty 4)
Keys (Qty 2)
FLAT PANEL MOUNTING HARDWARE
Plastic Lever Lock™
Locking Rivets (Qty 3)
#6 Washers For Mounting
Small-Screw Components
To Lever Lock™ (Qty 20)
Vertical Monitor
Mounting Brackets (Qty 2)
VESA 800 Monitor
Adapter Brackets (Qty 2)
Flange Nuts 5/16” - 18
(Qty 8)
Cable Management Clips (Qty 8)
Pan Head Screws 8-32 x 3/8”
(Qty 8)
Wire Ties (Qty 12)
Vertical Mounting
Bracket Locking Screws
10-32 x 3/4” (Qty 2)
Flange Nuts 10-32 (Qty 2)
Truss Head Screws
10-32 x 3/4” (Qty 8)

M8
M6
M5
M4
Dimples (Face Up)
Universal
Washer
Page 6
FLAT PANEL INSTALLATION
Selecting The Mounting Hardware To Attach Brackets To Flat Panel
1) Identify the correct diameter screw for the flat
panel threaded inserts. The correct screws
should thread easily and not pull out when
tension is applied.
2) To determine proper screw length, insert thread
depth indicator into a threaded insert on the flat panel.
3) Mark the thread depth indicator 1/8” above the
depth of the threaded insert. (FIGURE A)
4) Select a screw that is shorter than the 1/8” mark
made on the thread depth indicator.
Threaded Insert
!
FIGURE A
Thread Depth Indicator
Mark 1/8” Above Depth
CAUTION! Do not use any screw longer than the 1/8”
mark or damage to the flat panel may occur.
Universal Washers
Universal washers are designed to accommodate the various
M4, M5, M6 and M8 hole sizes found in flat panels. (FIGURE B)
FIGURE B
Small Straw
or toothpick Depth Plus 1/8”
Mark Allowance
Small Straw
or toothpick
Depth Plus 1/8”
Allowance Mark
Screen Size
(Diagonal
1080P)
Viewing Distance
Range
Recommended
Display Height
Range to
Display Center
32"
4.0-6.7 feet
48-50"
37"
50-54"
40"
5.0-8.3 feet
54-56"
46"
5.7-9.5 feet
56-58
50"
6.3-10.4 feet
58-60
60"
7.5-12.5 feet
60-62"
65"
8.1-13.5 feet
62-64"
70"
8.75-14.6 feet 65"
NOTE: It is reccomended to position the
display so that it is centered with the
eyeline of the viewer. The following chart
is provided to assist you with determining
the proper height of your display.
4.6-7.7 feet

Page 7
NOTES:
• Place flat panel on soft, flat surface while working.
• Do not place excessive pressure on back of the flat panel.
• Universal washers must be installed between the head of the
mounting screw and the vertical mounting bracket as shown.
(FIGURE D)
Nylon Spacers (FIGURE E, PAGE 8)
Nylon spacers add distance between vertical
mounting bracket and flat panel. They will fit
all supplied screw sizes. The spacers must be
used only when attaching flat panels which have:
• Recessed mount points
• Uneven mount points
• Any obstruction near the mount points
• A curved back
NOTES:
• Nylon Spacers must be stacked and oriented as shown.
• Nylon Spacers must only be installed between the
vertical mounting bracket and the flat panel.
Mounting Screws (4)
FLAT PANEL INSTALLATION (CONTINUED)
Universal
Washers (4)
Vertical Mounting Brackets (2)
FIGURE D
VESA 800 EXTENSION BRACKET INSTALLATION (IF REQUIRED)
1) For monitors that require VESA 800 spacing, the VESA 800 monitor adapter bracket must be
used (not required for VESA 600 or less spacing).
2) Place vertical monitor mounting brackets over VESA 800 adapter bracket studs and secure using
(4) 5/16” -18 flange nuts. (FIGURE C)
FIGURE C
Vertical Monitor
Mounting Bracket (1)
Flange Nuts
5/16”-18 (4)
VESA 800 Monitor
Adapter Bracket (1)

Page 8
Attaching Vertical Mounting Brackets to Flat Panel
NOTE: The brackets are indicated (L) Left and (R) Right.
1) Place the flat panel face down on a soft, flat surface and
identify the number and location of screws.
2) Align the holes on each vertical mounting bracket with the
threaded inserts on the flat panel. (FIGURE E)
NOTE: To ensure a neat appearance, center vertical
mounting brackets on flat panel. Do not extend
brackets past top or bottom of flat panel.
3) Secure each vertical mounting bracket with the
screws and hardware identified in previous
steps. Use a minimum of (2) mounting screws per
vertical mounting bracket.
Flat Panel
Universal
Washer
Nylon Spacer
Vertical
Mounting
Bracket
Mounting
Screw
FIGURE E
FLAT PANEL INSTALLATION (CONTINUED)
WARNING! This operation requires two people. Do not release your flat panel until you are certain
that the top hook of each vertical mounting bracket is securely seated on the upper rail of the
horizontal mounting bracket.
!
Flat Panel
Vertical Mounting
Bracket
FIGURE G
Horizontal
Mounting
Bracket
Locking
Brackets
FIGURE F
Hanging the Flat Panel
1) Lower both locking brackets on vertical mounting brackets. (FIGURE F)
2) Raise the flat panel slightly above the top and
bottom rails on the horizontal mounting bracket.
(FIGURE G)
3) Place the flat panel down slowly, ensuring that
the top and bottom hooks on the vertical mounting
brackets properly engage the horizontal
mounting bracket. (FIGURE G)

Page 9
FLAT PANEL INSTALLATION (CONTINUED)
FIGURE H
4) Slide flat panel sideways until vertical mounting brackets drop into notches in horizontal mounting
bracket. (FIGURE H)
NOTE:
Several notch locations are provided for horizontal position adjustment.
5) Raise monitor to highest position.
6) Raise both locking brackets and secure to vertical
mounting brackets using (2) 10-32 x 3/4 screws
and (2) 10-32 nuts. (FIGURE I)
FIGURE I
Notches
Screws (2)
10-32 x 3/4”
Nuts (2)
10-32

Page 10
DOOR REVERSAL PROCEDURE
1) Lift and twist door hinges to remove desired door. (FIGURE J)
FIGURE J
2) On lower door only, remove and reinstall hinge on opposite side. (FIGURE K)
3) Re-attach doors using holes provided.
FIGURE K
Hinge

Locking Rivet
Page 11
LEVER LOCK™ TOOL FREE INTERNAL MANAGEMENT SYSTEM
The FlexView comes equipped with the following Lever Lock™ items: (6) LL receptacle brackets,
(2) LL-HC21 horizontal channels, and (1) LL-VP1710 vertical 10” deep plate.
Use Horizontal
Channels To
Manage Cables
Use Vertical
Plate To Mount
Small Devices
Lever Lock™ Plate Installation / Configuration
1) Insert the Lever Lock™ plate into the
mating slots in the upper horizontal channel.
(FIGURE L)
2) Secure lock mechanism into the mating slots
in the lower horizontal channel. (FIGURE L)
NOTE: Position the flanges to the outside of
the rack to maximize usability.
FIGURE L
Use Receptacle
Brackets To Lace
Cable Bundles
From Top To Bottom
Horizontal Channel Installation / Configuration
1) Insert horizontal channels into the mating slots in
the side receptacle brackets. Ensure the lock
mechanism is facing the bottom of the rack.
(FIGURE M)
2) Push horizontal channels into place until
locking mechanism ‘clicks’.
FIGURE M
Lock Mechanism
1) Install plastic locking rivet into the inner
holes as shown to prevent locking
mechanism from disengaging. (FIGURE N) FIGURE N
Locking Rivet Installation
2-Space Rail
NOT FOR
COMPONENT
STORAGE

Page 12
Clip
Middle Atlantic PD-815SC
(8) outlet, 15 amp power strip
with surge and circuit breaker
CABLE MANAGEMENT / EQUIPMENT MOUNTING
Raise display to highest position before securing cables. Create a service loop to assure adequate
cable length when display is fully extended. Cables can be secured to movable clips (provided) using
wire ties. Position and secure clips in channels as necessary using screws. (FIGURE O)
Cable
FIGURE O
WARRANTY
Middle Atlantic Products (the "Company") warrants the FlexView™ FVS Series Electric Lift for a period of (7) seven years from date of
shipment by the Company.
The Company's entire liability to the purchaser, and the purchaser's (or any other party's) sole and exclusive remedy, under this warranty
shall be limited, at the Company's option, to either (a) return of and refund of the price paid for, or (b) repair or replacement at the
Company's factory of the products purchased, or any part or parts thereof, which the Company has determined to be defective after
inspection thereof at the Company's factory.
This warranty does not cover damage due to acts of God, accident, misuse, abuse or negligence by parties other than the Company, or
any modification or alteration of the products. In addition, this warranty does not cover damage due to improper handling, assembly,
installation or maintenance.
THIS WARRANTY IS IN LIEU OF ALL OTHER WARRANTIES OF ANY KIND, EITHER EXPRESSED OR IMPLIED, INCLUDING, BUT
NOT LIMITED TO, IMPLIED WARRANTIES OF MERCHANTABILITY AND FITNESS FOR A PARTICULAR PURPOSE.
TO THE MAXIMUM EXTENT PERMITTED BY APPLICABLE LAW, IN NO EVENT SHALL THE COMPANY BE LIABLE FOR ANY
SPECIAL, INCIDENTAL, INDIRECT, OR CONSEQUENTIAL DAMAGES WHATSOEVER (INCLUDING, WITHOUT LIMITATION,
DAMAGES FOR LOSS OF BUSINESS PROFITS, BUSINESS INTERRUPTION OR ANY OTHER PECUNIARY LOSS) ARISING OUT OF
THE USE OF THE PRODUCTS PURCHASED, EVEN IF THE COMPANY HAS BEEN ADVISED OF THE POSSIBILITY OF SUCH
DAMAGES. THE COMPANY'S LIABILITY TO THE PURCHASER (OR ANY OTHER PARTY) HEREUNDER, IF ANY, SHALL IN NO
EVENT EXCEED THE PURCHASE PRICE OF THE PRODUCTS PAID TO THE COMPANY.
Corporate Headquarters
Corporate Voice 973-839-1011 - Fax 973-839-1976 / International Voice +1 973-839-8821 - Fax +1 973-839-4982
middleatlantic.com - [email protected]
Middle Atlantic Canada
Voice 613-836-2501 - Fax 613-836-2690 / middleatlantic.ca - [email protected]
Factory Distribution
USA: NJ - CA - IL Canada: ON - BC
At Middle Atlantic Products we are always listening. Your comments are welcome.
Middle Atlantic Products is an ISO 9001 and ISO 14001 Registered Company.
Screw
Accessory /
Storage Trough
Cable Service
Loop Routing
To Flat Panel
Table of contents