Midea CCM15 Quick start guide

Thank you very much for purchasing our product.
Before using your unit, please read this manual carefully and keep it for future reference.
FULL DC INVERTER SYSTEMS
OWNER´S & INSTALLATION MANUAL
DATA CONVERTER GATEWAY CCM15
COMMERCIAL AIR CONDITIONERS SDV4

ƔThis manual gives detailed description of the precautions
that should be brought to your attention during operation.
ƔIn order to ensure correct service of the wired controller
please read this manual carefully before using the unit.
ƔFor convenience of future reference, keep this manual
after reading it.

Table of Contents
I. Safety Precautions.........................................................................................1
II. Installation and Operation of the Data Converter..........................................3
III. APP Function Description...........................................................................12
IV. Web Client Operation................................................................................ 37
V. Remote Web Client Operation.....................................................................38

1
I. Safety precautions
The following contents are stated on the product and the operation
manual, including usage, precautions against personal harm and
property loss, and the methods of using the product correctly and safely.
After fully understanding the following contents (identifiers and icons),
read the text body and observe the following rules.
ƔIdentifier description
Identifier Meaning
Means improper handling may lead to personal
death or severe injury.
Means improper handling may lead to
personal injury or property loss.
[Note]: 1. “Harm” means injury, burn and electric shock which need
long-term treatment but need no hospitalization
2. “Property loss” means loss of properties and materials.
Warning
Caution

2
ƔIcon description
Meaninglcon
It indicates forbidding. The forbidden subject-matter is indicated in the
icon or by images or characters aside.
Warning
Please entrust the distributor or professionals to install the
unit. The installers must have the relevant know-how.
Improper installation performed by the user without
permission may cause fire, electric,shock, personal injury
or water leakage.
Delegate
installation
Warning
Forbid
Forbid
Do not spray flammable aerosol to the wire
controller directly. Otherwise, fire may occur.
Do not operate with wet hands or let water enter
the wire controller. Otherwise, electric shock
may occur.
Usage
Warning
It indicates compulsory implementation. The compulsory subject-matter
is indicated in the icon or by images or characters aside.

II. Installation and Operation of the Data Converter
1. System structure diagram
The system mainly includes the central air conditioning system, data converter, router, App,
cloud server, and Web client. The user can monitor the air conditioning system via App or
Web client. The data converter is connected to the XYE bus of the air conditioner via port 485
of the air conditioner. The power supply is connected to the mains supply via an adapter. For
the detailed connection, see the following figure:
3
NOTE
It is recommended to wire from the Outdoor XYE port
Fig.2.1 Schematic diagram of connecting the outdoor unit to the central air-conditioning
system.

If the data converter can only be connected to the outdoor unit, the outdoor unit shall be set
to enable automatic addressing so that the indoor unit can be located. For multiple systems,
port XYE of the outdoor unit is connected to the data converter in hand-in-hand manner. To
use one LAN cable to connect multiple CCM15 gateways, associate CCM15 gateways with
one router. For the configuration, see section 3.1.
4
Fig.2.2 Schematic diagram of connecting the indoor unit to the central air-conditioning
system.
Note: The new CCM15 is compatible with the V5X, V4+S, V4+R and Mini VRF outdoor units
For more information, please contact the technical support engineer

5
2. Hardware instruction
Fig.3.1 Structure dimension drawing

6
Fig.3.2
Connect to the
Ethernet
communication
terminal 485 terminal
Power supply
terminal
RESET
Status indicator light
Input Voltage:DC5V

3. Instructions
7
1. Unpack the packing box to see if the accessories are all in readiness. Data converter
is shown as the following figure:
Name Qty. Outline
1
1
1
1
Data
Converter
Installation
operation
manual
Power adaptor
Wiring 3-terminal
and 1 bags of
fixed screws

8
2.Take the data converter out and power it on to see if the device is normal ( POWER
indicator lights up)
3. Data converter installation precautions
a. Don’t install it in the place where flammable gas leaks easily. Once flammable gas leakage
occurs and stagnate around the device, it may result in fire.
b. Keep the device from heating element as far as possible.
c. Don’t install it in the place that is too dirty or humid.
Fig.3.3
POWER indicator lights up
4. LED Indicators
POWER: It is a power indicator, indicating that the power supply of the system is normal and
the system is running.
IP: It is a network communication indicator. When it flashes, it indicates that the data
converter is accessing the Ethernet. When it is off, it indicates that the data converter is not
accessing the Ethernet. In this case, check network connection and configuration.
485: It is an air conditioner communication indicator. When it flashes, it indicates that the
communication between the air conditioner and data converter is normal. When it is off, it
indicates that cable connection to port 485 is wrong or port 485 is not connected to an air
conditioner.
The data converter is restarted upon detecting abnormal communication. (If port 485 does not
communicate within 60s or the network port does not communicate within 3 minutes, the data
converter is reset.) In this case, POWER, IP, and 485 indicators are on together.

Figure 3 LED indicators
LED
indicator
Colour Operating
status Description
485 Green Flash
Flash
Steady on
Green
Red
IP
POWER
When the indicator flashes, it indicates
that an air conditioner is connected.
When it flashes, it indicates that the data
converter is accessing the Ethernet.
Power supply of the system is normal.
9
Air conditioner
communication
indicator
Air conditioner
communication
indicator
Ethernet
connection
indicator
485 IP POWER

5. Getting an IP Address
By default, the IP address of the data
converter is achieved by DHCP and
allocated by the access router. Only when
App and data converter are configured on
one LAN, can App read the IP address of the
data converter. To set a static IP address for
the data converter, log in to the embedded
Function list of App client
①CCM15 list.
②CCM15 management.
③Account management.
④Group management.
⑤Logs.
⑥Temperature unit.
⑦Log out.
10
Web page of the data converter.
II. Function Description
The data convert supports Web, HTTP,
TCP, and IP. Therefore, the user can
remotely access the central conditioning
VRF system via WAN. The App client on
smart phones and Web client are available.
①③④⑤⑥⑦②

Web function list
"AC Control": air conditioner control
"Booking Control": scheduled operations
"Operation logs": operation logs
"User group": group management
11
APP download
IOS: Go to APP Store seach “Green Control Intensity” to download the app
Android: Please ask to your Intensity Contractor for reference of the Android App.

III. APP Function Description
1. Registration Function
1-1 Registration Code
Before registering an account, the user must enter the registration code, as shown in the
following figure. Open App client on the smart phone. Enter the registration code, such as
Intensity, which is the first step. Then, click "OK". A login interface with the specified logo is
displayed. See the following figure:(Note:Registration function only APP client)
12

1-2 Account Registration
A registered account is used to manage devices and set management permissions. The
registered account can also be used to log in to the App and Web clients.
Procedure:
13
Click "Register". Enter a valid email
account and password.
The account information
is generated on the
cloud platform.
After registration is
completed, activate the
account via the email.
Only the activated
account can be used
(Note:Email could be
delayed)

2 Virtual function
The virtual experience function is used for showing the main interface , AC control,
booking control and so on. Operation only available for choosing the unit of the
temperature and setting the AC, the other menu and function are invalid in this function.
14

①prompts CCM15
configuration. ②displays the CCM15
configuration interface. ③displays two
configuration manners:
using a network cable or
scanning a QR code.
2. App Configuration
Refer to the guide to connecting the CCM15 and port XYE of the outdoor unit. Connect
the CCM15 to the router. After login via App, the main interface prompts the user to
configure the CCM15, as shown in the following figure:
15
NOTE
Please connect the CCM15 to a network with administrator level permission, or not it
may lead to security problems about account configuration.

①Select a configuration manner.
②The App will search for the CCM15 devices on its LAN and displays the IP address of
each CCM15 gateway. As shown in the figure above, ②displays multiple CCM15
devices found. Only one CCM15 device can be selected for configuration. Select one,
and the system counts down. After configuration succeeds, it goes to the main interface
for displaying devices.
2-1: Using a Network Cable
Only when the following conditions are met, can the user configures the CCM15 via a
network cable:
A. The CCM15 must access a wireless router.
B. The smart phone and CCM15 must be located in one network segment and connected
to one wireless router.
C. The wireless router must access the Internet.
16

①Click "CCM15 Management". ②Click "+" at the upper right corner. The CCM15
configuration interface is displayed. ③Select a configuration manner. The subsequent
steps are the same as those for configuring the CCM15 via a network cable. Repeat
the preceding steps to add multiple CCM15 devices until all the CCM15 devices are
configured.
Note: When one LAN accesses multiple CCM15 gateways, IP addresses of these
gateways are displayed, as shown in ②. In this case, one-to-one correspondence
between the CCM15 gateways and the IP addresses cannot be achieved. It is
recommended that every time when the user completes configuring a CCM15 device,
the user should timely rename the CCM15 device and record its IP address.
The following figure shows how to configure multiple CCM15 gateways:
17
Table of contents
Other Midea Gateway manuals