Unit:mm
We reserve the right to change the specification without prior notice.
PR-0246B 2016/05 Printing
9
6
15.5
22.5
20
20
30
30
37
21.8
Rated pressure range
Withstand pressure
Applicable fluid
kgf/cm2
bar
psi
Pressure
resolution
Ambient humidity range
Vibration
Shock
Temperature characteristic
Weight
MaP
A. SPECIFICATIONS
TYPE
Battery
Battery life
Low-power indicator
Battery replaceable
Turn-on interval
Sampling rate
Repeatability
LCD display
Indicator accuracy
B. ORDERING INFORMATION
F1 : R1/8", M5
F2 : NPT1/8", #10-32 UNF
F3 : G1/8"(BSPP), M5
F4 : R1/4", M5
F5 : NPT1/4", #10-32 UNF
F6 : G1/4”(BSPP), M5
Pressure Port
MPG-60PL-F1
Optional Parts
C. PANEL DESCRIPTION
Battery Meter
Pressure Display
Setting Button
Pressure Unit
Display Section
D. DIMENSIONS
E.BATTERY STATUS / INSTALLATION
F1~F3:Hex flat:12
F4~F6:Hex flat:14
F1 : R1/8", M5
F2 : NPT1/8", #10-32 UNF
F3 : G1/8"(BSPP), M5
F4 : R1/4", M5
F5 : NPT1/4", #10-32 UNF
F6 : G1/4”(BSPP), M5
1
4
78
MPa
MPa
6
"+"
"-"
1.5MPa
0. ~ 1 000 Pa000 . M
Filtered air, incombustible and non-corrosive gases
0.01
0.01
0.1
0.001
Operation/Storage: 35 ~ 85% RH ( No condensation)
Total amplitude 1.5mm or 10G, 10Hz-55Hz-10Hz scan
for 1 minute, two hours each direction of X, Y and Z
100m/s (10G), 3 times each in direction of X, Y and Z
2
Approx. 40g
Yes
Yes
2 Hz (2 times/sec.)
3 ½ digit, 7 segment
±2% F.S. ±1 digit (ambient temperature: 25 ±3 ° C)
Operation: 0 ~ 50 ºC, storage: -10 ~ 60 ºC
( No condensation or freezing)
±2% F.S. of detected pressure (25 C) at temp.°
range of 0~50 C°
Ambient temp. range
Enclosure
Environment
5
2 3
For your safety, please read the following before using.
1
2
3
4
5
6
FOLLOW THE STEPS BELOW
● Using a flat screwdriver size 1.4 ~ 3.0 mm insert into the back of the
pressure gage as pictured. (See figure )
Turn the screwdriver horizontally 90 to separate the case and the base.●°
Repeat this process again for the other side. (See figure )
Carefully remove the outer cover (See figure ), and follow the diagrams●
below to replace battery and reassembly. Polarity must be observed,
incorrect battery installation will cause malfunction.
2
3
4
MPG-60 -P
(Positive)(Vacuum)
MPG-60 L-P
MPG-60V- MPG-60VL-
mmHg
CR 2032 lithium
Pressure Range
V : Vacuum (10 ~ -101kPa)
Positive (-0.100 ~ 1.000M a)PP:
0 ~ -101kPa
10 ~ -101kPa
Display pressure range
300kPa
Pak
-
-
0.01
0.1
1
1
-
-
Display turn off after 60 sec.
(Vacuum) (Positive)
psi bar mmHg kPa psi bar kgf MPa
Port size F1:R1/8”, M5; F2:NPT1/8”, #10-32 UNF; F3:G1/8”(BSPP), M5
F4:R1/4”, M5; F5:NPT1/4”, #10-32 UNF; F6:G1/4”(BSPP), M5
3 years
(5 times/day)
3 years
(5 times/day)
1 year
(5 times/day)
1 year
(5 times/day)
Pressure unit psi, bar, kgf/cm and MPa
2
user selectable
psi, bar, mmHg and kPa
user selectable
Back light Yes YesNo No
Back Light
Blank : Back light unavailable
L : Back light available
Do not use corrosive or flammable gas or liquid with this product.
Please use within the rated pressure range. Do not apply pressure
beyond recommended maximum withstand pressure, permanent
damage to the pressure gage may occur.
Do not drop, hit or allow excessive shock. Even if pressure gage
body appears undamaged, internal components may be broken and
can cause malfunction.
Do not use in environment containing steam or oil vapor.
This product is not explosion-proof rated. Do not use in atmosphere
containing flammable or explosive gases.
Using filter can extend pressure gage’s service life.
±0.2% F.S. ±1digit
± % F.S. ±1digit1
MG-60PSeries
MP-A5 : Mounting bracket
MP-A6 : Mounting bracket
MP-B2 : Panel adapter
MP-C2 : Panel adapter + Front protective lid
www.mindman.com.tw
-0.100 . M~ 1 000 Pa *1
*1. When the pressure is -0.1MPa, LCD displays MPa.
*2. Air tube must be installed to maintain IP65. (See section K)
IP65 2*
31 31 mm×+0
- 0.4
2Panel mountPanel mount
Panel adapter
Panel adapter
Front protective lid
Unit:mm
F
.
OPTIONAL PARTS DIMENSIONS
J. ZERO POINT RESET
Under measure mode, press button
for 2 ~ second .5s
I. PRESSURE UNIT SETTING MODE
Press than seconds.button for more 5
Measure mode
Use button to set desired pressure unit.
Unit setting
Measure mode
MPa
MPa
MPa
Measure mode
MPa
Measure mode
MPa
Zero point setting
MPa
kgf
bar
psi
MPa
MPa
G.
PRESSURE UNIT CONVERSION TABLE
K. DUST AND SPLASH ENVIRONMENT
To maintain IP65, please insert an air
tube (O.D.: 4mm) into atmospheric
release port and pipe the other end away
from dust / spattering liquid environment.
Use proper air tube dimension of
O.D.: 4mm, I.D.: 2.5mm, and the length
is on the user’s environment.depending Atmospheric release port
●
●
Air tube
Do not press button for 3 seconds to return to
measure mode.
L. ERROR CODE INSTRUCTION
Residual
pressure error
During zero reset, ambient
pressure is over ±3% F.S.
Change input pressure to ambient
pressure and perform zero reset again.
Applied
pressure error
Supply pressure is exceeds the
upper limit of pressure setting.
Adjust the pressure within operating
pressure range.
Error Type
Error code
Error Condition Troubleshooting
Battery error
When battery level is under
2.40V, the battery symbol
and will flash 4 times
then enter power save mode.
Replace battery.
From To
1 kPa
1 MPa
6.895 0.006895 0.07031 51.7157 1 0.06895
0.010000
10
0.145038
145.038
7.500616
7500.616
0.010197
10.197
0.001000
1
1
1000
100.0000 0.100000 1.01972 750.062 14.5038 1
0.98066514.2233735.5591
0.098066598.0665
0.00133320.01933610.00135950.0001330.13332
1 kgf/cm
2
1 mmHg
1 psi
1 bar
kPa MPa
kgf/cm
2
mmHg psi bar
H.
POWER-SAVE MODE
Measure mode Power-Save mode
MPa
MODEL:KP60P/KP60PL
kPa
mmHg
bar
psi
MODEL:KP60V/KP60VL
Supply pressure is exceeds the
lower limit of pressure setting.
◎The pressure gage will enter power saving mode if the button is not
pressed within 60 sec.
In measure mode, press the button to extend display for 120 sec.◎
no operation for 60 or 120 sec.
Front protective lid
Release the button when “ ” is shown.
Panel adapter
www.mindman.com.tw
MP-A5
MP-A6
1
M3x0.5
M3x0.5
Mounting bracket MP-A5
Mounting bracket MP-A6
Mounting bracket

Other Mindman Measuring Instrument manuals

Mindman MP30 Series User manual

Mindman

Mindman MP30 Series User manual

Mindman MPG-60 Series User manual

Mindman

Mindman MPG-60 Series User manual

Popular Measuring Instrument manuals by other brands

VeEX FX20 quick guide

VeEX

VeEX FX20 quick guide

GHM HONSBERG OMNIPLUS-F Series operating manual

GHM

GHM HONSBERG OMNIPLUS-F Series operating manual

Blue-White F-1000 instruction manual

Blue-White

Blue-White F-1000 instruction manual

Bosch BEA 060 Original instructions

Bosch

Bosch BEA 060 Original instructions

Omega VSHYe Series Installation and operation manual

Omega

Omega VSHYe Series Installation and operation manual

VOLTCRAFT 2109292 operating instructions

VOLTCRAFT

VOLTCRAFT 2109292 operating instructions

Lutron Electronics SL-4011 Operation manuals

Lutron Electronics

Lutron Electronics SL-4011 Operation manuals

Pulse Instruments POA08 user manual

Pulse Instruments

Pulse Instruments POA08 user manual

PCB Piezotronics 357A08 Installation and operating manual

PCB Piezotronics

PCB Piezotronics 357A08 Installation and operating manual

Davis Instruments Electronic Rain Counter instruction manual

Davis Instruments

Davis Instruments Electronic Rain Counter instruction manual

Sentinel Hub installation guide

Sentinel

Sentinel Hub installation guide

Ares 10020 Operation manual

Ares

Ares 10020 Operation manual

Circutor DCP-96 Aac instruction manual

Circutor

Circutor DCP-96 Aac instruction manual

ANATEL Novus RHT-Air instruction manual

ANATEL

ANATEL Novus RHT-Air instruction manual

Megasat HD 5 Combo user manual

Megasat

Megasat HD 5 Combo user manual

Ludlum Measurements 43-5 manual

Ludlum Measurements

Ludlum Measurements 43-5 manual

Endress+Hauser Gammapilot M FMG60 Brief operating instructions

Endress+Hauser

Endress+Hauser Gammapilot M FMG60 Brief operating instructions

Beko FLM SF53 Installation and operation instruction

Beko

Beko FLM SF53 Installation and operation instruction

manuals.online logo
manuals.online logoBrands
  • About & Mission
  • Contact us
  • Privacy Policy
  • Terms and Conditions

Copyright 2025 Manuals.Online. All Rights Reserved.