This module has three special functions, the default is closed, if necessary, you can
open them.
Function 0:After electricity,it will automatically output.
Function 1: Save and bring up the parameters, display the power and capacity.
Function 2: Automatic take turns to show parameters after output
Open/close method:
Long press the"OK" button, then to the module electricity, the LED will take turns to
show in "--0-"~"--2-" , when display "--0-" ,release the"OK" button will open or
close function 0, when display "--1-" ,release the"OK" button will open or close
function 1, when display "--2-" ,release the"OK" button will open or close function 2.
After releasing the "OK" button the digital tube display "--y-" said already open the
current function, the display "--n-" said it already close the current function.
1、Enable the function 0 it will automatically output after electricity.
2、Enable the function 1, in the condition of no output, press "SET" button will take
turns to show among voltage "00.00", current "0.000", bring up the parameters "Lo.-
0" and save the parameters "SA.- 0". Below illustrate this function:
For example:we need store10V, 1.5 A in the storage location 1 and bring up the
parameter from storage location 1.
1Press "SET" button to switch to the voltage value, setting voltage value of
10.00 V, press "SET" button to save the voltage value.
2Press "SET" button to switch to the current value, setting current value of
1.500 A, press "SET" button to save the current value.
3Press "SET" button to switch to the "SA.-0", press the or button to select
the storage location, here need to adjust to "SA.-1", press "OK" button to store the "10
V, 1.5 A" in the storage location 1.
4Press "SET" button to switch to "Lo.-0", press the or button to select the
storage location which the parameter need to bring up, here need to adjust to "Lo.-1",
then press the "OK" button to bring up the parameters of storage location 1.
5This module has total of 0 ~ 9 common 10 groups of storage location, the
storage location can be set arbitrary voltage and current value.
3、Enable the function 2,after output,it will automatically take turns to display the
parameters such as voltage, current, power and capacity.
Note:
1、Properly connect input and output, it is forbidden to reverse connection, or it will
be burn out.
2、This module is a step-down module, input voltage need over output voltage more
than 1.5 V.
3、
Output under 2A natural cooling, output above 2A shall strengthen heat dissipation.
Display:
00.00: voltage value ,00.00 ~ 36.00 V
0.000: current value, 0.000 ~ 3.000 A
P. 000, P0.00, P00.0, P000. : power value, unit W, the position of the decimal point as