Our Products warrant this product to be free from manufacturing defects for a period of one year from the original date of
consumer purchase. This warranty is limited to the repair or replacement of this product only and does not extend to con-
sequential or incidental damage to other products that may be used with this product. This warranty is in lieu of all other
warranties, expressed or implied. Some states do not allow limitations on how long an implied warranty lasts or permit the
exclusion or limitation of incidental or consequential damage, so the above limitations may not apply to you. This warranty
gives you specific rights, and you may also have other rights which vary from state to state.
Warranty
This device complies with part 15 of the FCC and Industry Canada license-exempt RSS standard(s). Operation is subjected
to the following two conditions:
FCC / IC
(1) This device may not cause harmful interference,
(2) This device must accept any interference received, including interference that may cause undesired operation.
This parameter can access you to set the switch to be on/off after power failure.
(LED flashes twice when the configuration parameter changed.)
Operation: Quickly press the button 10 times (Please note: the switching of each value is in order, quickly press on the
button 10 times will switch once. eg: Switching from value 0 to value 2 needs 2 switching. )
Parameter=6,Size=1
Value=0 --- The switch is off regardless of the state prior to power failure.
Value=1 --- The switch is on regardless of the state prior to power failure.
Value=2(default) --- This switch will be return to state prior to the power failure after power is restored.
Restores state after power failure
Adjust LED brightness (quickly press 8x: change Parameter.)
(Green LED flashes twice to confirm the setting is successful.)
Parameter=7, Size=1,
Value=0 --- Bright
Value=1 --- Medium
Value=2 --- Low (default.)
FCC NOTE:
The manufacturer is not responsible for any radio or TV interference caused by unauthorized
modifications to this equipment. Such modifications could void the user’s authority to operate the equipment.
— Reorient or relocate the receiving antenna.
— Increase the separation between the equipment and receiver.
— Connect the equipment into an outlet on a circuit different from that to which the receiver is connected.
— Consult the dealer or an experienced radio / TV technician for help.
NOTE:
This equipment has been tested and found to comply with the limits for a Class B digital device, pursuant to Part
15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference in a residential
installation. This equipment generates, uses and can radiate radio frequency energy and, if not installed and used in accorda-
nce with the instructions may cause harmful interference to radio communications. However, there is no guarantee that
reception, which can be determined by turning the equipment off and on, the user is encouraged to try to correct the
interference by one or more of the following measures:
interference will not occur in a particular installation. If this equipment does cause harmful interference to radio or television
Important note:
To comply with the FCC RF exposure compliance requirements, no change to the antenna or the
device is permitted. Any change to the antenna or the device could result in the device exceeding the RF exposure require-
ments and void user’s authority to operate the device.
CAUTION - PLEASE READ!
This device is intended for installation in accordance with the National Electric Code and local regulations in the United
States, or the Canadian Electrical Code and local regulations in Canada If you are unsure or uncomfortable about performing
this installation consult a qualified electrician.
WARNING
RISK OF FIRE / RISK OF ELECTRICAL SHOCK / RISK OF BURNS TO REDUCE THE RISK OF ELECTRIC SHOCK, THIS
Please DO NOT use this switch to control Medical or Life Support equipment. Z-Wave devices should never be used to
control the On / Off status of Medical and / or Life Support equipment.
PRODUCT HAS A GROUNDING TYPE PLUG THAT HAS A THIRD (GROUNDING) PIN. THIS PLUG WILL ONLY
FIT INTO A GROUNDING TYPE POWER OUTLET. IF THE PLUG DOES NOT FIT INTO THE OUTLET, CONTACT
A QUALIFIED ELECTRICIAN TO INSTALL THE PROPER OUTLET. DO NOT CHANGE THE PLUG IN ANY WAY.
CONTROLLING APPLIANCES:
CAUTION: TO REDUCE THE RISK OF OVERHEATING AND POSSIBLE DAMAGE TO OTHER EQUIPMENT
• DO NOT EXCEED RATINGS
• DO NOT USE TO CONTROL ANY DEVICE
WHERE UNINTENDED OPERATION COULD CAUSE UNSAFE CONDITIONS (HEAT LAMP, SUN LAMP, ETC.)
Please exercise EXTREME CAUTION when using Z-Wave devices to control appliances. Reason being is because the
appliance you want to control may be in a separate room and if unintentional behavior occurs (such as adevice turning on or
off - either intentionally via schedules, or unintentionally via network error) this event may lead to a hazardous condition.
For these reasons, please note the following suggestions:
1) Do not include Z-Wave devices in Groups or Scenes if they control appliances.
2) Do not use Z-Wave devices to control electric heaters or any other appliances which may present a hazardous condition
due to unattended, unintentional, or automatic power control.
MEDICAL EQUIPMENT
CONTROLLING APPLIANCES
0x5E - ZWAVEPLUS_INFO
0x25 - SWITCH_BINARY
0x70 - CONFIGURANTION
0x85 - COMMAND_CLASS_ASSOCIATION
0x8E - COMMAND_CLASS_MULTI_CHANNEL_ASSOCIATION
0x59 - COMMAND_CLASS_ASSOCIATION_GRP_INFO
0x55 - COMMAND_CLASS_TRANSPORT_SERVICE
0x86 - COMMAND_CLASS_VERSION
0x72 - COMMAND_CLASS_MANUFACTURER_SPECIFIC
0x5A - COMMAND_CLASS_DEVICE_RESET_LOCALLY
0x87 - COMMAND_CLASS_INDICATOR
0x73 - COMMAND_CLASS_POWERLEVEL
0x9F - COMMAND_CLASS_SECURITY_2
0x6C - COMMAND_CLASS_SUPERVISION
0x7A - COMMAND_CLASS_FIRMWARE_UPDATE_MD
GRNERIC DEVICE CLASS: 0x10 - SWITCH BINARY
SPECIFIC DEVICE CLASS: 0x00 – NOT_USED
COMMANDCLASS:
Command Class Information