Minuteman RPM20161VN User manual

RPM1581HVN
RPM20161VN
RPM2082HVI
RPM20162VI
(Remote Power Manager)
User’s Manual

Table of Contents
1. IMPORTANT SAFETY INSTRUCTIONS..................................................................................1
2. Introduction...............................................................................................................................3
3. RPM Package...........................................................................................................................4
4. Function....................................................................................................................................5
5. Installation ................................................................................................................................6
6. Web Interface ...........................................................................................................................7
7. Specifications..........................................................................................................................22
8. Obtaining Technical Assistance..............................................................................................23
9. Limited Product Warranty .......................................................................................................24

1
1. IMPORTANT SAFETY INSTRUCTIONS
This manual contains important instructions that should be followed during the installation and the
operation of the Remote Power Manager (RPM).
SAVE THESE INSTRUCTIONS
An Important Notice
To ensure safety in all applications ensure that a Qualified Service Personnel installs the system.
Make sure that the AC Utility outlet is properly grounded.
Do not open the unit there are no serviceable parts inside. This will void the warranty.
Do not try to repair the unit yourself, see Obtaining Service.
Please make sure that the input voltage of the RPM matches the supply voltage.
Use a certified input power cord with the correct plugs and sockets for the appropriate voltage
system.
Make sure the RPM is installed in the proper environment as specified. (0-50°C and 0-90% non-
condensing humidity)
This RPM series is ONLY intended to be installed in an indoor temperature controlled environment
that is free of conductive contaminants.
Do not operate the RPM in: extremely dusty and/or unclean areas, locations near heating devices,
water or excessive humidity, or where the RPM is exposed to direct sunlight.
Select a location, which will provide good air circulation for the RPM at all times.
This RPM supports electronic equipment in offices, telecommunications, process control, security,
and IT applications.
Servicing of RPM should be performed by Qualified Service Personnel Only.
CAUTION – To reduce the risk of fire, connect only to a branch circuit with over current protection in
accordance with the National Electric Code.
CAUTION - Connect the RPM to a two pole, three wire grounding AC wall outlet. The receptacle
must be connected to the appropriate branch protection (circuit breaker or fuse). Connection to any
other type of receptacle may result in a shock hazard and violate local electrical codes. Do not use
extension cords, adapter plugs, or surge strips.
Route power cords so they cannot be walked on or damaged.
CAUTION - To reduce the risk of electrical shock with the installation of this RPM equipment and the
connected equipment, the user must ensure that the combined sum of the AC leakage current does
not exceed 3.5mA.
CAUTION - To de-energize the outputs of the RPM: Disconnect the RPM from the AC wall outlet.
CAUTION - Do not install this device if there is not at least 30 feet (10 meters) or more of wire
between the electrical outlet and the electrical service panel.
SSL Configuration:
These RPMs only support the SSLv1 protocol, which in most browsers is no longer
supported. Please DO NOT ENABLE the SSL function, doing so will require resetting the
RPM back to the factory default settings. See page 5 the ‘Function Button’ to reset to the
factory default settings.

2
Receiving Inspection
After removing your RPM from its carton, it should be inspected for damage that may have occurred in
shipping. Immediately notify the carrier and place of purchase if any damage is found. Warranty claims
for damage caused by the carrier will not be honored. The packing materials that your RPM was
shipped in are carefully designed to minimize any shipping damage. In the unlikely case that the RPM
needs to be returned to MINUTEMAN, please use the original packing material. Since MINUTEMAN is
not responsible for shipping damage incurred when the system is returned, the original packing material
is inexpensive insurance. PLEASE SAVE THE PACKING MATERIALS!
Para Systems Life Support Policy
As a general policy, Para Systems Inc. (Para Systems) does not recommend the use of any of its
products in life support applications where failure or malfunction of the Para Systems product can be
reasonably expected to cause failure of the life support device or to significantly affect its safety or
effectiveness. Para Systems does not recommend the use of any of its products in direct patient care.
Para Systems will not knowingly sell its products for use in such applications unless it receives in writing
assurances satisfactory to Para Systems that (a) the risks of injury or damage have been minimized, (b)
the customer assumes all such risks, and (c) the liability of Para Systems Inc. is adequately protected
under the circumstances.
Examples of devices considered to be life support devices are neonatal oxygen analyzers, nerve
stimulators (whether used for anesthesia, pain relief, or other purposes), auto transfusion devices, blood
pumps, defibrillators, arrhythmia detectors and alarms, pacemakers, hemodialysis systems, peritoneal
dialysis systems, neonatal ventilator incubators, ventilators for both adults and infants, anesthesia
ventilators, and infusion pumps as well as any other devices designated as “critical” by the United States
FDA.

3
2. Introduction
The RPM is an Internet ready device designed and equipped with an intelligent current-meter (True RMS) that
will indicate the total power consumption of the RPM.
Features:
Built-in web server.
Build-in true RMS current meter.
Easy setup.
7-segment LCD provides useful information.
Supports SNMP traps, which can be monitored by an NMS.
Supports SSL.
Sends emails and traps when an event occurs.
Provides an audible warning when the load exceeds the rating of the RPM.
Outlet protection via circuit breaker.
Individual control of the power outlets.
Group control of the power outlets.
LEDs visually indicate the status of the outlets.
Supports power on sequence.

4
3. RPM Package
The standard RPM package contains a Remote Power Manager unit with supporting hardware. The contents of
the package are:
Remote Power Manager unit.
Rackmount Brackets.
CD-ROM, which contains:
User Manual.
MIB files.
Adobe Acrobat Reader.

5
4. Function
Interface
7-segment LCD
Functions Description
Ethernet RJ45 port for the network communication.
Audible Alarm Warning- 1 beep in 1 second.
Overload- 3 beeps in 1 second.
Note: The audible alarm will keep beeping until the current is lower than
the threshold by 0.5 amps.
Function Button Press and release the function button to turn off the audible alarm.
Note: The overload alarm cannot be silenced.
Press and hold the function button for 2 beeps, then release will
display the IP address
Press and hold the function button for 4 beeps, then release will
change the way to set the IP address by either DHCP or fixed IP.
Press and hold the function button for 6 beeps, then release resets
the RPM back to the default setting.
Meter 3 digits will display the current and/or the IP Address.
ID The identification of the RPM.
LED Indicator SSL (yellow) LED: On means the web access is protected by SSL.
DHCP (green) LED: On means the RPM gets its IP address by DHCP.
Status (green) LED: Indicates each outlet’s power status.
Circuit Breaker Overload protection.

6
5. Installation
This RPM series is ONLY intended to be installed in an indoor temperature controlled environment that is free of
conductive contaminants. DO NOT operate the RPM in: extremely dusty and/or unclean areas, locations near
heating devices, water or excessive humidity, or where the RPM is exposed to direct sunlight. Select a location,
which will provide good air circulation for the RPM at all times. Route power cords so they cannot be walked on or
damaged.
Rack Mount Instructions
A) Elevated Operating Ambient Temperature - If installed in a closed or multi-unit rack assembly, the operating
ambient temperature of the rack environment may be greater than room ambient temperature. Therefore,
consideration should be given to installing the equipment in an environment compatible with the maximum
ambient temperature specified by the manufacturer.
B) Reduced Air Flow - Installation of the equipment in a rack should be such that the amount of airflow required
for safe operation of the equipment is not compromised.
C) Mechanical Loading - Mounting of the equipment in the rack should be such that a hazardous condition is not
achieved due to uneven mechanical loading.
D) Circuit Overloading - Consideration should be given to the connection of the equipment to the supply circuit
and the effect that overloading of the circuits might have on over current protection and supply wiring.
E) Reliable Earthing - Reliable Earthing of rack-mounted equipment should be maintained. Particular attention
should be given to supply connections other than direct connections to the branch circuit (e.g. use of power
strips)."
Hardware
The RPM comes with brackets for mounting into a rack. To mount the RPM into a rack perform the following
procedure:
1. Attach the mounting brackets to the RPM, using the four retaining screws provided for each of the brackets.
2. Select the desired location for the RPM.
3. Align the mounting holes of brackets with the notched hole on the vertical rail and attach with the retaining
screws.
4. Connect the Ethernet cable to the RPM.
5. Connect the output devices to the RPM outlets.
6. Connect the input power cord of the RPM to the wall outlet.
Note 1:
The default setting for the IP address is DHCP enabled. If the RPM cannot get the IP from DHCP server, the IP
address will stay at the default IP address 192.168.0.216
Note 2:
To setup the network system for RPM, it is strongly recommended to build up the power monitoring network
system, which is isolated from the others, in order to maintain reliable system operation.

7
6. Web Interface
Login:
Enter the IP address of RPM in a web browser.
Note:
The default setting for the IP address is DHCP enabled. If the RPM cannot get the IP from the DHCP server, the IP
address will remain at the default IP address 192.168.0.216
The default User name is snmp.
The default Password is 1234.

8
Information: RPM
This screen displays the total current draw of the RPM.

9
Information: System
Indicates the RPM’s system information, including:
Model No.
Firmware Version
MAC Address
System Name
System Contact
Location

10
Control: Outlet
Indicates the RPM’s outlet on/off status and control.
Select the outlet by checking the box and then click the ON or the OFF button to control the outlet.
ON: Press the ON button to turn on the assigned outlets.
OFF: Press the OFF button to turn off the assigned outlets.
OFF/ON: Press the OFF/ON button to reboot the assigned outlets.

11
Control: Group
This allows you to group multiple outlets for group control.
Setting: Allows you to enter into the setting mode.
Outlet: Allows you to assign the outlet to a group.
Note:
The identified outlets need to be listed in the alphabetical order.
ON: Press the ON button to turn on the assigned group.
OFF: Press the OFF button to turn off the assigned group.
Active: Enables the controllable group.

12
Control: Schedule
This allows you to Schedule turning OFF/ON the RPM’s outlets.
Outlet: Assign the outlet to be controlled in this schedule.
Every: Set the schedule for an outlet using: a single day, an assigned weekly day, or every day.
Date: When selecting the single day option “sgl” under the “Every” column, a specific date must be
entered.
Begin: End: Action:
Turn on outlet at this time None ON
Turn off outlet at this time None OFF
Turn off outlet at this time Turn on outlet at this time OFF/ON
Turn on outlet at this time Turn off outlet at this time ON/OFF
Active: Enables the assigned schedule control.

13
Control: Ping Action
This allows you to Ping the device that is connected to a specific outlet and if there is no response the outlet can be
rebooted.
Automatically cycle’s power to a locked device connected to the RPM by rebooting the outlet.
Ping IP Address: Set the IP address of the device to be monitored by the RPM.
Response 10 minutes: The RPM will ping the assigned IP address once each minute. If the device does
not respond, then the RPM will repeat the ping once every minute, if the device does not respond after 10
attempts (10 minutes), the RPM will carry out the assigned action automatically.
Action: Select the outlet action “OFF” or “OFF/ON”
Active: Enables this function.

14
Configuration: RPM
Configure the outlet name and the delay time.
Name: Rename the outlet.
ON: Set the delay time for the power on sequence.
OFF: Set the delay time for the power off sequence.
Note:
The maximum delay time is 255 seconds.
Note:
After the RPM is plugged into the main power, the RPM will automatically start to sequentially turn on the outlets
according to the preset delay time. The default setting for delay time is one second for each outlet; therefore the 8
outlet RPM will take 8-seconds, the 24 outlet RPM will take 24-seconds to complete the start-up sequence.
If the RPM is unplugged from the main power before the start-up sequence is completed, the outlets, which are not
turned on will remain off. The next time the RPM is plugged into the main power, these outlets will not be
automatically turned on. These outlets can only be turned on via the web interface.

15
Configuration: Threshold
Set the warning and overload thresholds for entire RPM.

16
Configuration: User
Change the ID (User name) and the password.
The default ID (User name) is snmp and the password is 1234.

17
Configuration: Network
Enter the network information or enable the DHCP function.
The default setting for DHCP is enabled.

18
Configuration: Mail
When an event occurs, the RPM can send out email messages to predefined accounts.
Email Server: Input the email server’s domain name (does not support IP addresses).
Sender’s Email: Input the sender’s email address.
Email Address: Input the recipient’s email address.
The email message format is as follows:
Indicates the Outlets A~H-XXXXXXXX status in order
X=0: means the outlet is off.
X=1: means the outlet is on.
Note: Make sure the DNS server can resolve the email server’s domain name.
This manual suits for next models
3
Table of contents
Popular Control Unit manuals by other brands

PERSTA
PERSTA DVA 200 BZ operating instructions

Dormakaba
Dormakaba MFC installation instructions

EWM
EWM Tetrix AC/DC Comfort 2.0 operating instructions

Viessmann
Viessmann EM-EA1 extension Installation and service instructions

Bosch
Bosch Rexroth DB 52 3X E Series operating instructions

TECSYSTEM
TECSYSTEM NT538 WS instruction manual