miseno MH00630BS User manual

2018.SEP
JUL18.0101
MH00630BS
MH00636BS
MODEL #.
MH00830BS
MH00836BS
1
SAFETY NOTICE ................................................................. 2-3
LIST OF MATERIALS....................................................... 4
INSTALLATION
Ducting Calculation Sheet....................................... 5
Mounting Height & Clearance................................ 6
Ducting Options ........................................................... 7
Hood Specications RH006 ................................... 8
Hood Specications RH008 ................................... 9
Mounting the Hood RH006 ..................................... 10
Mounting the Hood RH008 ..................................... 11
Ductless Recirculating .............................................. 12
FEATURES & CONTROLS
Electronic Controls ..................................................... 13
MAINTENANCE
Hood and Filter Cleaning......................................... 14
CFM SELECT................................................................................. 15
WIRING DIAGRAMS................................................................... 16
TROUBLESHOOTING................................................................ 17
LIST OF PARTS AND ACCESSORIES .............................. 18
WARRANTY.................................................................................... 19
Table of Contents
Important Safety Notice
READ AND SAVE THESE INSTRUCTIONS
2
WARNING
TO REDUCE THE RISK OF FIRE OR ELECTRIC SHOCK, DO NOT USE THIS FAN WITH ANY SOLID-STATE CONTROL DEVICE.
WARNING
TO REDUCE THE RISK OF FIRE ELECTRIC SHOCK, OR INJURY TO PERSONS, OBSERVE THE FOLLOWING:
a. Use this unit only in the manner intended by the manufacturer, if you have questions, contact the manufacturer.
b. Before servicing or cleaning unit, switch power off at service panel and lock panel to prevent power from being switched on accidentally.
When the service disconnecting means cannot be locked, securely fasten a prominent warning device, such as a tag, to the service
panel.
CAUTION
For general ventilating use only. Do not use to exhaust hazardous or explosive materials and vapors. Take care when using cleaning
agents or detergents. Suitable for use in household cooking area.
WARNING
TO REDUCE THE RISK OF RANGE TOP GREASE FIRE:
a. Never leave surface units unattended at high settings. Boilovers cause smoking and greasy spillovers that may ignite. Heat oils slowly
on low or medium settings.
b. Always turn hood ON when cooking at high heat or when aming food
c. Clean ventilating fans frequently. Grease should not be allowed to accumulate on fan or lter.
d. Use proper pan size. Always use cookware appropriate for the size of the surface element.
e. Keep fan, lters and grease laden surfaces clean.
f. Use high setting on hood only when necessary.
g. Don’t leave hood unattended when cooking.
h. Always use cookware and utensils appropriate for the type of and amount of food being prepared.
WARNING
TO REDUCE THE RISK OF INJURY TO PERSONS IN THE EVENT OF A RANGE TOP FIRE, OBSERVE THE FOLLOWING:
a. SMOTHER FLAMES with a close-tting lid, cookie sheet, or metal tray, then turn off the burner. BE CAREFUL TO PREVENT BURNS.
If the ames do not go out immediately, EVACUATE AND CALL THE FIRE DEPARTMENT.
b. NEVER PICK UP A FLAMING PAN – You may be burned.
c. DO NOT USE WATER, including wet dishcloths or towels – a violent steam explosion will result.
d. Use an extinguisher ONLY if:
1. You know you have a Class ABC extinguisher, and you already know how to operate it.
2. The re is small and contained in the area where it started.
3. The re department is being called.
4. You can ght the re with your back to an exit
WARNING
TO REDUCE THE RISK OF FIRE, ELECTRIC SHOCK OR INJURY TO PERSONS, OBSERVE THE FOLLOWING:
a. Installation work and electrical wiring must be done by qualied person(s) in accordance with all applicable codes and standards.
Including re-rated construction.
b. Sufcient air is needed for power combustion and exhausting of gases through the ue (chimney) of fuel burning equipment to prevent
back-drafting. Follow the heating equipment manufacturer’s guideline and safety standards such as those published by the National
Fire Protection Association (NFPA) and the American Society for Heating, Refrigeration and Air Conditioning Engineers (ASHRAE) and
the local code authorities.
c. When cutting or drilling into wall or ceiling, do not damage electrical wiring and other hidden utilities.
d. Ducted fans must always vent to the outdoors.
e. NEVER place a switch where it can be reached from a tub or shower.
f. Make sure the power is off before installing, wiring or maintenancing.
Important Safety Notice
3
WARNING
TO REDUCE THE RISK OF FIRE, USE ONLY METAL DUCTWORK.
CAUTION
To reduce risk of re and to properly exhaust air outside - Do not vent exhaust air into spaces within walls, ceilings,
attics, crawl spaces or garages.
Not for use over an outdoor grill.
This hood is not intended to be used as a shelf.
OPERATION
Always leave safety grilles and lters in place. Without these components, operating blowers could catch onto hair, ngers
and loose clothing.
The manufacturer declines all responsibility in the event of failure to observe the instructions given here for installation,
maintenance and suitable use of the product. The manufacturer further declines all responsibility for injury due to
negligence and the warranty of the unit automatically expires due to improper maintenance.
ELECTRICAL REQUIREMENTS
Important:
Observe all governing codes and ordinances.
It is the customer’s responsibility:
- To contact a qualied electrical installer.
- To assure that the electrical installation is adequate and in conformance with National Electrical Code, ANSI/NFPA 70
latest edition* or CSA standards C22.1-94, Canadian Electrical Code, Part 1 and C22.2 No.0-M91 - latest edition** and
all local codes and ordinances.
If codes permit and a separate ground wire is used, it is recommended that a qualied electrician determine that the
ground path is adequate.
Do not ground to a gas pipe.
Check with a qualied electrician if you are not sure the range hood is properly grounded.
Do not have a fuse in the neutral or ground circuit.
*National Fire Protection Association Batterymarch Park, Quincy, Massachusetts 02269
** CSA International 8501 East Pleasant Valley Road, Cleveland, Ohio 44131-5575
This appliance requires a 120V 60Hz electrical supply and connected to an individual properly grounded branch circuit
protected by a 15 or 20 ampere circuit breaker or time delay fuse. Wiring must be 2 wire with ground. Please also refer to
Electrical Diagram on product.
A cable locking connector (not supplied) might also be required by local codes. Check with local requirements, purchase
and install appropriate connector if necessary.
MH00630BS, MH00636BS - 320 Watts, 2.6 Amps
MH00830BS, MH00836BS - 320 Watts, 2.6 Amps
Power consumption shown above is the default power specs. Hoods with CFM Selector Technology enabled will consume
less power. See wiring diagram at the end of this manual for more information.
4
PARTS NOT SUPPLIED
- Ducting, conduit and all installation tools
- Cable connector (if required by local codes)
- Extension duct cover accessory
- Recirculating kit accessory
HARDWARE PACKAGE CONTENTS
PARTS SUPPLIED
1 - Hood with internal blower
1 - Duct cover wall bracket
1 - Duct cover assembly (top and bottom)
1 - Hardware package
1 - 6” round backdraft damper (pre-installed)
1 - 5W LED Light Strip
2 - Baffle Filters
MH00630BS, MH00636BS
(4) #6 x 1-1/2” (2) #6 x 1” (2) 4 x 8mm (3) Wire Nuts
MH00830BS, MH00836BS
(3) #6 x 1-1/2” (2) #6 x 1” (2) 4 x 8mm (3) Wire Nuts
List of Materials
5
Duct pieces To tal
Equivalent number
length x used =
3-1/ 4” x 10”
Rect.,
straight
1 Ft. x ( ) =Ft.
3-1/ 4” x 10”
Rect.to
6” round
transition
5 Ft. x ( ) =Ft.
3-1/ 4” x 10”
Rect.to
6” round
transition
900 elbow
20 Ft. x ( ) =Ft.
6”, 7”, 8”, 10”
Round,
900
15 Ft.
x ( ) =Ft.
6”, 7”, 8”, 10”
Round,
450
9 Ft. x ( ) =Ft.
Ft.
6”, 7”, 8”, 10”
Round,
straight
1 Ft. x ( ) =Ft.
Subtotal column 1 =
Duct pieces To tal
Equivalent number
length x used =
6”, 7”, 8”, 10”
Round, wall
cap with
damper
30 Ft. x ( ) =Ft.
Ft.
Ft.
Ft.
6”, 7”, 8”, 10”
Round
roof cap
30 Ft. x ( ) =Ft.
Subtotal column 2 =
Subtotal column 1 =
Total ductwork =
Maximum Duct Length: For satisfactory air movement,
the total duct length
should not exceed 100 equivalent feet.
6” round to
3-1/ 4” x 10”
rect.
transition
1 Ft. x ( ) =Ft.
6” round to
3-1/ 4” x 10”
rect.
transition
900 elbow
16 Ft. x ( ) =Ft.
7” round to
3 1/ 4” x 10”
rect.
transition
8 Ft. x ( ) =Ft.
7” round to
3-1/ 4” x 10”
rect.
transition
900 elbow
23 Ft. x ( ) =Ft.
elbow
elbow
7” to 6” or
8” to 7” Round
tapered
reducer
25 Ft. x ( ) =Ft.
3-1/ 4” x 10”
Rect.900
elbow
15 Ft. x ( ) =Ft.
3-1/ 4” x 10”
Rect.450
elbow
9 Ft. x ( ) =Ft.
3-1/ 4” x 10”
Rect.900
flat elbow
24 Ft. x ( ) =Ft.
3-1/ 4” x 10”
Rect.
wall cap
with damper
30 Ft. x ( ) =Ft.
Ft. x ( ) =Ft.
15
6”, 7“, 8”
Round
in-line
damper
Installation – Ducting Calculation Sheet
Installation – Mounting Height & Clearance
6
DUCTING
A minimum of 6” round duct must be used to
maintain maximum air ow efciency.
Always use rigid type metal ducts only. Flexible
ducts could restrict air ow by up to 50%.
Use calculation worksheet to compute total duct
work (Page 5).
ALWAYS, when possible, reduce the number of
transitions and turns. If a long duct run is required,
increase duct size from 6” to 7” or 8”.
If turns or transitions are required: Install as far
away from duct opening and as far apart between
the two transitions as possible.
Minimum mount height between range top to hood
bottom should be no less than 24”.
Maximum mount height should be no higher than
34”.
It is important to install the hood at the proper
mounting height. Hoods mounted too low could
result in heat damage and re hazard; while hoods
mounted too high will be hard to reach and will
loose performance and efciency.
If available, also refer to range manufacturer’s
height clearance requirements and recommended
hood mounting height above range. Always check
your local codes for any differences.
Duct cover extension kit available for ceiling
heights up to 12 feet. Turn to page 18 for part
number and ordering information.
DAMAGE-SHIPMENT / INSTALLATION:
• Please fully inspect unit for damage before
installation.
• If the unit is damaged in shipment, return the
unit to the store in which it was bought for
repair or replacement.
• If the unit is damaged by the customer, repair
or replacement is the responsibility of the
customer.
• If the unit is damaged by the installer (if other
than the customer), repair of replacement must
be made by arrangement between customer
24” min.
34” max.
min. A
min. B
max. C
min. D
min. E
max. F
Standard Extension
Hood Heights Duct Cover Duct Cover
minimum ducted (A) 26” 41“
minimum recirculating (B) 31” 45-1/2“
maximum (C) 49” 78-1/2”
Ceiling Heights
minimum ducted (D) 86” 101“
minimum recirculating (E) 91” 105-1/2“
maximum (F) 119” 148-1/2”
36”
MH008
Standard Extension
Hood Heights Duct Cover Duct Cover
minimum ducted (A) 27-1/2” 46-1/2“
minimum recirculating (B) 32” 50-1/2“
maximum (C) 42-1/2” 80”
Ceiling Heights
minimum ducted (D) 87-1/2” 106-1/2“
minimum recirculating (E) 92” 110-1/2“
maximum (F) 104-1/2” 150”
MH006
7
and installer.
WARNING FIRE HAZARD
NEVER exhaust air or terminate duct work into spaces between walls, crawl spaces, ceiling, attics or garages.
All exhaust must be ducted to the outside, unless using the recirculating option.
Use single wall rigid metal ductwork only.
Fasten all connections with sheet metal screws and tape all joints w/ certied Silver Tape or Duct Tape.
Some Ducting Options
Installation – Ducting Options
side wall cap
w/ gravity damper
Soffit or crawl space
Roof Pitch w/
Flashing & Cap
ductless
recirculating
side wall cap
w/ gravity damper
8
Installation – Hood Specication MH006
1"
11
8
"
13
16
"
37
16
"
29
15
16
"
83
4
"
63
4
"
12"
19
3
4
"
35 7
8
"
,
Standard Duct Cover
Min. ducted 27
1/2
”
Min. recirc. 32”
Max. ducted 42
1/2
”
RHEX001S Extension
Min. ducted 46
1/2
”
Min. recirc. 50
1/2
”
Max. ducted 80”
9
Installation – Hood Specication MH008
29 15/16”, 35 7/16”
14 1/8”
2 13/16”
20 1/16”
STANDARD
min. ducted - 26”
min. recirc. - 31”
max. - 49”
RHEX008S EXTENSION
min. ducted - 41”
min. recirc. - 45-1/2”
max. - 78-1/2”
11”
10 9/16”
5 15/16”
CL
1 3/16”
3 9/16”
4 1/2”
10
Installation – Mounting the Hood MH006
1. Measure from range top to hood bottom and mark line A.
(24” minimum from range top) .
2. Plum and mark center line.
3. Mark mounting height line B. (12” from line A)
4. Mark mounting spread from C/L on line B. From center
line to left mount mark (3-1/2”). From center line to right
mount mark (2”).
5. Fasten (2) #6x1-1/2” screws into studs on line B. Do not
fasten screws all the way. Note: wood blocking may
need to be added behind the drywall if no studs are
present. Wall anchors may also be used but check
local codes for compliance. Failure to use suitable
wall anchors to hold the weight of the hood could
result in personal injury or damage to the cooking
surface or counter.
6. Hang hood onto screws and hand tighten. (Fig.A) Use
the last #6x1-1/2” screw to further secure the hood to the
wall from inside the hood.
7. Center and attach duct cover bracket to wall below
ceiling or soft using (2) #6x1” screws.
8. Install electrical.
9. *Install duct work and duct tape.
10. Power up hood and check for leaks around duct tape.
11. Place telescopic duct covers onto hood and extend
inner (top) duct cover upwards and secure to duct cover
bracket using (2) 4 x 8mm screws.
*If using hood in recirculating mode you must secure air
diverter plate onto wall before installing duct work and
duct covers. Turn to page 14 for more details.
A
B
C/L
12"
2"
C/L
24" min
fig. A
Duct Cover Bracket
3-1/2"
WARNING: Electrical wiring must be done by a qualified person(s) in
accordance with all applicable codes and standards. This range hood must be
properly grounded. Turn off electrical power at service entrance before wiring.
!
Cable Lock
Cable Lock
A cable locking connector (not supplied) might
be required by local codes. Check with local
requirements and codes, purchase and install
appropriate connector if necessary.
CAUTION: At least two installers are
required due to the weight and size of the
hood.
!
11
1. Measure from range top to desired hood bottom location and
mark line A. (24” minimum from range top) .
2. Plum and mark center line.
3. Mark hood height line B. (11-1/16” from line A)
4. Mark mounting spread from C/L. (12-5/8” on line B)
5. Fasten (2) #6 x 1-1/2” screws into studs on line B but do not
tighten all the way. Note: Wood blocking may need to be
added behind the drywall if no studs are present. Wall
anchors may also be used but check local codes for
compliance. Failure to use suitable wall anchors to hold
the weight of the hood could result in personal injury or
damage to the cooking surface or counter.
6. Remove (2) screws securing electrical junction box to hood
body. Remove junction box.
7. Remove the (2) lters. Hang hood onto the mounting screws
and hand tighten each screw. (FIG. A #1) Secure third #6 x
1-1/2” screw with washer through inside of hood into wall for
extra support. (FIG. A #2)
8. Center and attach duct cover mounting bracket to wall just
below the ceiling or soft using (2) #6 x 1” screws. (FIG. A #3)
9. Install duct work and seal with aluminum duct tape*. Re-install
junction box with cable lock and install the electrical. Power up
hood to verify all functions and check for leaks around duct tape
10. Place telescopic duct covers onto hood and extend inner (top)
duct cover upwards and secure to duct cover bracket using (2)
4 x 8mm screws. Re-install lters.
* If using hood in recirculating mode you must secure the air
diverter plate onto wall before installing duct work and duct
covers. Refer to page 14 for more details.
11
1/16
”
Brackets are
pre-installed
24” Min.
A
B
3
1
2
Duct Cover Bracket
12
5/8
”
CAUTION: At least two installers ar
e
required
due to the weight and size of th
e
hood.
!
WARNING: Electrical wiring must be done by a qualified person(s) in
accordance with all applicable codes and standards. This range hood must be
properly grounded. Turn off electrical power at service entrance before wiring.
!
Cable Lock
A cable locking connector (not supplied) might
be required by local codes. Check with local
requirements and codes, purchase and install
appropriate connector if necessary.
Installation – Mounting the Hood MH008
FIG. A
12
Ductless recirculation is intended for applications where an exhaust duct work is not possible to be installed.
When converted, the hood functions as a recirculating hood rather than an exhaust hood. Fumes and exhaust
from cooking are drawn and ltered by a set of optional charcoal lters. The air is then puried and re-
circulated back within the home.
We recommend to ALWAYS exhaust air outside of the home by employing existing or installing new duct
work, if possible. The hood is most effective and efcient as an exhaust hood. Only when the exhaust option
is not possible should you recourse to converting the hood into a recirculating hood.
When converted to be a recirculating hood, a set of charcoal lters are required on top of its standard Bafe
Filter set. Order according to its part number below. The standard Bafe Filters are intended to capture
residue from cooking and the optional charcoal lters help to purify fumes exhausted from cooking for re-
circulation.
RECIRCULATING KIT (REQUIRED IF NO DUCTING IS USED)
Kit includes charcoal lters, charcoal lter brackets and air diverter plate.
Hood Models Part No. Filters & Brackets in pkg.
MH006 RHRK006BS 2
MH008 RHRK008BS 2
1. Purchase recirculating kit per the part number above
2. Secure air diverter plate to wall below duct cover bracket. (FIG. C) Run 6”
ducting from top of hood and secure to air diverter plate.
3. Remove bafe lters from hood. Install charcoal lters to back side of bafe
lters by 10 rubber clips and 2 magnets for each lter. (FIG. C)
4. Re-Install bafe lters. For more details refer to manual included with
recirculating kit.
5. Charcoal lters must be replaced after every 120 hours of use (or
approximately every 3 to 4 months based on an average of 1 - 2 hrs. of daily
cooking time).
Charcoal Filter Replacements
Hood Model Part No. Qty to Order
MH006, MH008 Z0F-C005 2
DO NOT WASH CHARCOAL FILTERS. Charcoal lters may need
to be changed more often depending on cooking habits.
Installation – Ductless Recirculating
Magnet
Magnet
FIG. C
13
- Power / Delay o button will turn power on and o for the entire hood (fan and lights).
- The hood will remember the last speed and light level it was last turned o at.
- Delay O Feature: With the fan on, press and hold the power button for three seconds. The fan
will change to speed 1 and automatically turn o after 5 minutes.
- CFM Select Feature: CFM Select allows the installer to set the maximum fan CFM to align with
local codes and regulations.
To verify the maximum fan CFM:
With hood o, press and hold the power button for ve seconds. If all three fan speed
indicators illuminate = default maximum CFM. If two speed level indicators illuminate
= 390 maximum CFM. If only one speed level indicator illuminates = 290 maximum CFM.
Lights are two levels, low and high. From o, press once for low, press again for high, press again to
power lights o.
Fan is three speed levels. From o, press once for low, press again for medium, press again for high,
press again to power fan o.
Power / Delay Off
Lights
Fan Speeds
Features & Controls - Electronic Controls
14
SURFACE MAINTENANCE:
Do not use corrosive detergents, abrasive detergents or oven cleaners.
Do not use any product containing chlorine bleach or any product containing chloride.
Do not use steel wool or abrasive scrubbing pads which will scratch and damage surface.
Cleaning Stainless Steel
Clean periodically with warm soapy water and clean cotton cloth or micro ber cloth. Always rub in the
direction of the stainless steel grain. To remove heavier grease build up use a liquid degreaser detergent.
After cleaning use a non-abrasive stainless steel polish/cleaners, to polish and buff out the stainless luster
and grain. Always scrub lightly, with clean cotton cloth or micro ber cloth and buff in the direction of the
stainless steel grain.
Bafe Filters
The bafe lters installed by the factory are intended to lter out residue and grease from cooking. They
need not be replaced on a regular basis but are required to be kept clean.
Remove and clean by hand or in dishwasher on low heat. Spray degreasing detergent and leave to soak if
heavily soiled.
Dry lters and re-install before using hood.
Removing Bafe Filters
1. Pull down on spring loaded handle
2. Pull down on lter handle to remove lter
Maintenance – Hood and Filter Cleaning
15
CFM Select
CFM SELECT
Some local codes limit the maximum amount of CFM a range hood can move. CFM Select allows you to control
the maximum blower CFM of the range hood without the need for expensive make up air kits. CFM Select enables
the installer to easily set the maximum blower speed to one of two most commonly specied CFM levels; 390 or
290 CFM. The usage of CFM Select may not be necessary for your installation. Please check your local codes for
CFM restrictions.
By default the maximum blower CFM is set to 750.
To enable CFM Select
1. Before hood installation, gain access to PC board by following the steps shown in FIG. C.
2. Change plastic jumper positioning as shown in FIG. D to set the desired maximum blower CFM.
3. Re-install PC board & continue with hood installation.
4. Remove the appropriate foil CFM sticker included with the hood literature and place inside the hood body below
the wiring diagram or in another clearly visible location.
NOTE: After re-positioning the jumper and powering on the hood, the CFM cannot be changed again.
To verify if your installer enabled CFM Select
With hood off, press and hold the power button for ve seconds. If 3 LEDs illuminate = defualt max. CFM, if 2 LEDs
illuminate = max. 390 CFM, and if 1 LEDs illuminate = max. 290 CFM.
When CFM Select is enabled, the number of blower speeds will be reduced. 390 CFM = max. 2 speeds and 290
CFM = max. 1 speeds.
There should also be a foil label located inside the hood body near the wiring diagram that indicates the blower
CFM.
PC Board
Ju mp er 5- 6 or 7-8
DEFAULT POSITION
Default Max. Blower CFM
Ju mp er 3 -4
Max. Blower CFM
390
Ju mp er 1 -2
Jumper Pins
Plastic
Jumper
1
3
5
7
2
4
6
8
1
3
5
7
2
4
6
8
1
3
5
7
2
4
6
8
Max. Blower CFM
290
AC
MOTOR
LAMP
12
34
6
5
8
7
CAUTION:
Hood must be disconnected from main power prior to performing the
conversion instructions listed below. Failure to do so could result in
personal injury or damage to the product.
!
- PC Board is located behind light panel.
- Remove bafe lters and light panel.
- Remove 2 screws attaching control board
assembly.
FIG. C FIG. D
16
Wiring Diagrams
MH00630BS
MH00636BS
GRAY
MH00830BS
MH00836BS
17
Troubleshooting
TROUBLESHOOTING PROCEDURES
Issue Cause What to do
After installation,
the unit doesn’t
work.
1. The power source is not turned ON. 1. Make sure the circuit breaker and the unit’s
power is ON.
2. The power line and the cable locking connector
is not connecting properly.
2. Check the power connection with the unit is
connected properly.
3. The switch board and control board wirings are
disconnected.
3. Make sure the wirings between the switch
board and control board are connected
properly.
4. The switch board or control board is defective. 4. Change the switch board or control board.
Light works, but
blower is not
turning.
1. The blower wire is not connected. 1. Make sure the blower wire is plugged into the
molex connector.
2. Blower molex plug pin is not making contact. 2. Disconnect the blower molex plug, check pins
inside plug to see if pin is pushed inside the
plug too far. Reseat pin if needed.
3. The blower is defective, possibly seized. 3. Change the blower.
4. The thermally protected system detects if the
blower is too hot to operate and shuts the blower
down.
4. The blower will function properly after the
thermally protected system cool down.
5. Damaged capacitor. 5. Change the capacitor.
6. The switch board or control board is defective. 6. Change defective part.
The unit is
vibrating.
1. The blower is not secured in place. 1. Tighten the blower in place.
2. Damaged blower wheel. 2. Replace the blower.
3. The hood is not secured in place. 3. Check the installation of the hood.
Only one or two
fan speeds work.
1. The installer may have adjusted the maximum
CFM of the hood to meet local codes.
1. Refer to page 13 to verify the CFM.
The blower is
working, but the
lights are not.
1. The LED strip plug is disconnected. 1. Connect the LED strip plug.
2. Defective LED strip. 2. Change the LED strip.
The hood is
not venting out
properly.
1. The hood might be hanging to high from the
cook top.
1. Adjust the distance between the cook top and
the bottom of the hood within 24” and 34”
range.
2. The wind from the opened windows or opened
doors in the surrounding area are affecting the
ventilation of the hood.
2. Close all the windows and doors to eliminate
the outside wind ow.
3. Blockage in the duct opening or ductwork. 3. Remove all the blocking from the duct work or
duct opening.
4. The direction of duct opening is against the wind. 4. Adjust the duct opening direction.
5. Using the wrong size of ducting. 5. Change the ducting to at least 6” or higher.
Mesh Filter is
vibrating.
1. Mesh lter is loose. 1. Change the mesh lter.
18
DESCRIPTION PART#
Optional Accessories
RH006 Recirculating Kit RHRK006BS
RH008 Recirculating Kit RHRK008BS
Replacement Charcoal Filters (each) Z0F-C005
RH006 Extension Duct Cover RHEX001S
RH008 Extension Duct Cover RHEX008S
Replacement Parts
Bafe Filter 50210034
Order replacement parts from us by calling 1.888.750.1698
List of Parts & Accessories

This manual suits for next models

3

Other miseno Ventilation Hood manuals

miseno MH10836BS User manual

miseno

miseno MH10836BS User manual

miseno MH00436G User manual

miseno

miseno MH00436G User manual

miseno MH80120AS User manual

miseno

miseno MH80120AS User manual

miseno MH70330AS User manual

miseno

miseno MH70330AS User manual

miseno MH00630AS User manual

miseno

miseno MH00630AS User manual

miseno MH70130BS User manual

miseno

miseno MH70130BS User manual

miseno MH20330AS User manual

miseno

miseno MH20330AS User manual

miseno MH10836AS User manual

miseno

miseno MH10836AS User manual

miseno MH70130AS User manual

miseno

miseno MH70130AS User manual

miseno MH00830AS User manual

miseno

miseno MH00830AS User manual

miseno RH70130BS Installation guide

miseno

miseno RH70130BS Installation guide

miseno MH00130CS User manual

miseno

miseno MH00130CS User manual

miseno MH70230BS User manual

miseno

miseno MH70230BS User manual

Popular Ventilation Hood manuals by other brands

Brandt AD1039X Guide to installation

Brandt

Brandt AD1039X Guide to installation

IKEA LAGAN manual

IKEA

IKEA LAGAN manual

Electrolux EFG540G user manual

Electrolux

Electrolux EFG540G user manual

Franke FGC 915 I XS LED Instructions for use and installation

Franke

Franke FGC 915 I XS LED Instructions for use and installation

Faber Egyzia Angolo installation instructions

Faber

Faber Egyzia Angolo installation instructions

Olimpia splendid UNICO AIR 8 HP Instructions for installation, use and maintenance

Olimpia splendid

Olimpia splendid UNICO AIR 8 HP Instructions for installation, use and maintenance

Luisi Air FOGO Installation, use and maintenance instructions

Luisi Air

Luisi Air FOGO Installation, use and maintenance instructions

ZANKER ZKC62640XA user manual

ZANKER

ZANKER ZKC62640XA user manual

Siemens LC 86950 GB Operating and installation instructions

Siemens

Siemens LC 86950 GB Operating and installation instructions

Electrolux LFV316K user manual

Electrolux

Electrolux LFV316K user manual

Zanussi Professional Export 642375 Specifications

Zanussi

Zanussi Professional Export 642375 Specifications

Whirlpool Ventilation Hood Installation and use guide

Whirlpool

Whirlpool Ventilation Hood Installation and use guide

Miele DA 292 i operating instructions

Miele

Miele DA 292 i operating instructions

Fulgor Milano CLUSTER CONCEPT 90 Instructions for installation and use

Fulgor Milano

Fulgor Milano CLUSTER CONCEPT 90 Instructions for installation and use

Smeg KSET56LEX2WL Instruction on mounting and use

Smeg

Smeg KSET56LEX2WL Instruction on mounting and use

Miele DAS 4630 Operating and installation instructions

Miele

Miele DAS 4630 Operating and installation instructions

FALMEC LUMEN 60 Instruction booklet

FALMEC

FALMEC LUMEN 60 Instruction booklet

Wolf Pro Wall Series installation guide

Wolf