Mitsumi MinebeaMitsumi ForceSensorEvaluationKit5 User manual

copyright 2019 MinebeaMitsumi Inc.
1
Instruction Manual of ForceSensorEvaluationKit5
Rev.0
2022.02.17
MITSUMI ELECTRIC CO.,LTD.
Semiconductor Business Div.

copyright 2019 MinebeaMitsumi Inc.
Instruction Manual of ForceSensorEvaluationKit5
2
Evaluation Kit
Force/Torque Sensor sample
Evaluation Board
ForceSensorMultiFingerEvaBoard Ver.1.0
FW Ver.1.0.0.3
Evaluation App. ForceSensor_MultiFingerEvaProgram
App Ver. 1.0.0.3
Cable
•Cable for sensor connection
•Ethernet cable
This Evaluation Kit consists of below:
AC adaptor
*Ethernet cable is not included.
Required Spec. Ethernet cable:
Cat5e or higher/ RJ-45 Plug
Conversion Board
Conv. BD Ver1.1
*AC adaptor is not included.
Required Spec. AC adaptor:
Output DC voltage 5V/
Output current capacity 0.5A or more/
Plug No. PL04B

copyright 2019 MinebeaMitsumi Inc.
3
Evaluation Board
In Red: Our Products
U1:
MCU
SW2:
Tactile Switch(Reset)
JP8:
Jumper
(For connection of sensor FG and system GND)
TH14:
FG terminal of the sensor
U4:
LDO(For Sensor Analog Supply)
U2:
Ethernet PHY
Instruction Manual of ForceSensorEvaluationKit5
CN8:
Modular Jack
X2:
Clock 25MHz (For PHY)
ForceSensorMultiFingerEvaBoardVer1.0
Board Size:70x70mm
X1:
Clock 24MHz(For MCU)
U3:
LDO(For system power supply)
U7:
LDO(For Built-in LDO Supply of Sensor Analog)
SW1:
Slide Switch(For MCU mode switching)
CN1:
Connector(Unused)
CN2:
Connector(For sensor1 of SPI)
CN3:
Connector(For sensor2 of SPI)
CN4:
Connector(For sensor3 of SPI)
CN5:
Connector(For seonsor4 of SPI)
CN6:
Connector(For sensor5 of SPI)
CN7:
Connector
(For JTAG)
CN9:
DC Jack
JP1:
Jumper(For Built-in LDO Supply of Sensor Analog)

copyright 2019 MinebeaMitsumi Inc.
4
Setting the Evaluation Board
Instruction Manual of ForceSensorEvaluationKit5
No Connection Setting Remarks
JP1 Short ●Power to sensor Enable LDO with built-in sensor JP1 and JP2-7 are exclusive.
Only short-circuit JP1.
Open Disable LDO with built-in sensor
JP2-7 Short Power to sensor Enable LDO (U4) of the evaluation board
Open ●Disable LDO (U4) of the evaluation board
JP8 Short Connection of sensor FG and system GND of the evaluation board JP8 should be open, and TH14 and
chassis GNDs should be connected.
Open ●
No Function Remarks
CN1 - Unused
CN2-6 For sensor1~5 of SPI connection
No Setting Function Remarks
SW1 1ON MCU operation mode setting Do not change for debugging purposes.
2 OFF
3 OFF
4 OFF
SW2 Reset Reset MCU only.
Jumper
Connector
Switch
●:Factory setting

copyright 2019 MinebeaMitsumi Inc.
Conversion Board
5
How to connection
Connect the evaluation board as shown below.
Instruction Manual of ForceSensorEvaluationKit5
PC
Force/Torque sensor
Cable for sensor connection
Evaluation Board
Ethernet cable
AC adaptor
Chassis GND

copyright 2019 MinebeaMitsumi Inc.
6
Communication method
Instruction Manual of ForceSensorEvaluationKit5
Set value
IP address 192.168.0.200
Sub-net mask 255.255.255.0
Gateway 192.168.0.254
Port No. 1366
MAC address 0x74,0x90,0x50,0x00,0x79,0x03
Communication between the host and the evaluation board uses the UDP method for Ethernet communication.
Ethernet communication setting of the evaluation board
The host-side IP address must match up to the third octet (192.168.0).
The fourth octet, 200 series, is planned to be used on the evaluation board side.
Use a number other than 200 series.

copyright 2019 MinebeaMitsumi Inc.
7
Setting the evaluation board
Instruction Manual of ForceSensorEvaluationKit5
Set value
FW Ver. 1.0.0.x 1.0.1.x 1.0.2.x
IP address 192.168.0.200 192.168.0.201 192.168.0.202
MAC address 0x74,0x90,0x50,0x00,0x79,0x03 0x74,0x90,0x50,0x00,0x79,0x04 0x74,0x90,0x50,0x00,0x79,0x05
The IP address and the MAC address of the evaluation board are managed by the firmware version.
The third digit of the firmware version, the fourth digit of the IP address, and the sixth digit of the MAC address
are linked.
The IP address information on the back of the evaluation board

copyright 2019 MinebeaMitsumi Inc.
8
Evaluation App
Instruction Manual of ForceSensorEvaluationKit5
When the connection of the evaluation board is completed, start the app main unit.
*To operate this application, .NET Framework 3.5 must be valid.
The activation procedure is posted on the Microsoft website. If it is not activated, activate it according to the contents of
the website.
ForceSensorMultiFingerEvaluationProgram_ver.1.0.0.3
├ ForceSensorMultiFingerEvaluationProgram.exe :App main unit
├ NPlot.dll :Graph Drawing Library
├ UserData :Data saving folder
When you unzip the "ForceSensorMultiFingerEvaluationProgram_ver.1.0.0.3" zip file,
the file configuration is as follows.
*Do not change the file configuration.

copyright 2019 MinebeaMitsumi Inc.
9
Instruction Manual of ForceSensorEvaluationKit5
Fx,Fy,Fz measurement graph
Mx,My,Mz measurement graph
Fx,Fy,Fz measurement value
Mx,My,Mz measurement value
・Interval:Temperature update interval setting
*1msec step
・”Immed.” button:Temperature update button
*Regardless of Interval setting above, the
temperature is updated at the timing of
clicking the button.
Evaluation App display screen
Ethernet communication setting with the board
・Source Port:PC port number
・Destination IP Address:Board IP address
・Destination Port:Board port number
・”BIND” button: Communication establishment
・”FREE” button: Communication release
Communication setting with sensor
・Select one of I2C or SPI
・S1~S5:Select the sensor to be measured
“INIT.” button:
Read the matrix operation correction coefficients form the sensor,
and start sensor operation.
Change to light green during operation
・”START” button: Measurement start button
・”STOP” button: Measurement stop button
・”RESET” button: Board initialize button
・”STATUS” button: Board state check button
・”CALIB” button: Calibration button
*Change to red during calibration
・”SAVE” button: Data save button
*Measurement data is output as a text data.
Graph drawing ON/OFF
Fx,Fy,Fz measurement graph
Y-axis scale setting
*Set around 0 N
Mx,My,Mz measurement graph Y-axis scale setting
*Set around 0 Nm
Measurement graph X-axis scale setting
*The maximum value that can be set changes
depending value of interval
Version display
Displaying the response value of “STATUS” button
・Interval:Data acquisition interval setting
*The setting is 1-1000msec (1msec step)
・Limit:Number of measurements setting
・Measuring:Number of measurements display

copyright 2019 MinebeaMitsumi Inc.
10
How to use the evaluation application software
Instruction Manual of ForceSensorEvaluationKit5
1.Communication setting with the board
Set the PC port number, board IP address, and port number, and then click “BIND” button.
Button “FREE” to cancel.
When communication with the board is established, Firmware and Hardware versions of the board are displayed.
2.Select the sensor to be measured
Select SPI, use check box of S1 to S5 to select the sensor1 to 5, and then click “SELECT” button.
Button “RELEASE” to cancel.
3.Enter "Interval" and click "INIT.“
4.Enter “Meas.Times”
*Start sensor operation.
While the sensor is operating, the “INT.” button turns to the light green button.
Click again to stop sensor operating.

copyright 2019 MinebeaMitsumi Inc.
11
How to use the evaluation application software
Instruction Manual of ForceSensorEvaluationKit5
5.Enter X Width and Y Width (Value can be changed even during measurement)
6.Set whether to update temperature
Temperature is updated at set time intervals by checking Interval. (Cannot be changed after START)
“Immed.” button updates the temperature at the timing of clicking the button.
(The key is only enabled after START.)
Temperature updating with the "Immed." button performs temperature updating regardless of the time
interval of Interval. *Compatible with ver.1.0.0.2
7.Click “START” button to begin measuring
8.Click “STOP” button to stop measuring
When the acquisition of the number of times set in "Limit" is completed, the measurement is automatically stopped.
9.Graphing can be disabled by removing “Graph” check box.
Processing capacity is broken in the graph drawing by the specification of the PC, and the data may not be acquired at the
cycle set by "Interval". Graph drawing disabled, data acquisition can be prioritized.
10. Stop the sensor operation by clicking "INIT." *Stops sensor operation.
When the sensor operation is stopped, the “INT.” button becomes gray.

copyright 2019 MinebeaMitsumi Inc.
12
Evaluation application software “Function of offset calibration”
Instruction Manual of ForceSensorEvaluationKit5
The sensor output has an initial offset. Offsets also occur due to mounting and gravity.
It is possible to calibrate the offset deviation with the "CALIB." Button.
Press the "CALIB." Button again to cancel offset calibration.
↑Clicking "CALIB.“ button changes CALIB to red.
↑Point of calibration
Click "CALIB.“button again to
return CALIB to black.
↓
The average data of 10 times before pressing the
“CALIB” button is used for offset calibration.
↑Point at which offset
calibration was canceled

copyright 2019 MinebeaMitsumi Inc.
13
Evaluation application software “Data save”
Instruction Manual of ForceSensorEvaluationKit5
The data acquired by measurement can be saved with the "Save" button.
Data is saved in UserData folders with the file name “Log”+“Date, Time”+“.txt”(LogYYYYMMDDHHSS.txt).
The data will be saved in the following format.
Click “SAVE” button
↓
When saving is completed, the following popup is displayed.
↓
The data of the selected sensor is saved.
Table of contents