Mobotix MX-Door2-INT-ON-PW Instructions for use

The HiRes Video Company
EN
www.mobotix.com
HiRes Video Innovations
The German company MOBOTIX AG is known as the leading pioneer in network camera technology and its
decentralized concept has made high-resolution video systems cost-ecient.
MX-DoorMaster: Quick Install
Security Door Opener with
Access Code Storage
Controls door openers via encrypted MxBus
communication and provides a doorbell for indoor
installation (includes backup power supply for
bell features and door opener)
Standard Connection: MX-DoorMaster with
IP Video Door Station, Door Opener and Door Sensors
Installing the MX-DoorMaster
Installing the module follows the procedure described in the
IP Video Door Station System Manual Part1,
in
Section
2.5, “Installing the MX-DoorMaster”
. Please also refer to this section to get more information on connection variants
(e.g. relay or Mediator operation).
Charging the Battery Pack after Installing
Once you have installed the module, you need to charge the MX-DoorMaster's battery pack without interruption
for at least 12 hours. The IP Video Door Station and its PoE power supply automatically charge the module via
the MxBus two-wire connection. Note that you should not use the door opener MX-DoorMaster during this time
(except for a short functional test). This ensures that you can extend the life cycle of the high-quality NiMH battery
pack (heavy-duty industrial grade) to several years (given normal usage).
Supported Door Openers
Standard door openers with 6 to 12VAC (min. 16Ω internal resistance) can be attached directly to the MX-DoorMaster;
such a door opener is powered by the integrated battery pack. In this case, you do not need an additional power
supply for the door opener. As an alternative, you can also connect door openers with up to 24V AC/DC (max. 1A)
using an external power supply (relay operation) or a self-locking door lock (“Mediator”; see
IP Video Door Station
System Manual Part1,
Section 2.5, “Installing the MX-DoorMaster”
).
Replacing the Battery Pack
First, dismount the MX-DoorMaster (see the
IP Video Door Station System Manual Part1
,
Section 2.4.6, “Removing
and Exchanging Modules”
). Next, replace the battery pack and install the MX-DoorMaster again (see
Section 2.5.4,
“Installation Using Cavity or In-Wall Socket”
).
Replacing the MX-DoorMaster
If the MX-DoorMaster needs to be replaced against all expectations, you need a current backup of the system
configuration. This will ensure that you can restore the encryption data later on. Please follow the steps outlined in
the
IP Video Door Station System Manual Part2
in
Section 5.2, “Backup & Restore”
. To dismount the MX-DoorMaster,
follow the steps in the
IP Video Door Station System Manual Part1
in
Section 2.4.6, “Removing and Exchanging
Modules”
.
• Open door, doorbell o/on, change sound
• Door indicator (open, closed, locked)
• Status LEDs for signaling
• Backup power supply with rechargeable battery
• Connection for door opener, door sensor and door lock
sensor
MOBOTIX MX-DoorMaster
MX-Door2-INT
includes 2 additional frames
(concave, angular), cavity wall socket
and mounting supply
Outdoor Indoor
Door
2
6
MxBus (YSTY 0.8 mm – max. length: 50 m)
Theft protection (YSTY 0.8 mm – max. length: 50 m)
Door opener, door sensor, lock sensor
(YSTY 0.8 mm – max. length: 50 m)
MX-DoorMaster
MX-Door2-INT
IP Video Door Station
2
For additional information on the other connection variants and for installing,
see the
IP Video Door Station System Manual Part1
on www.mobotix.com> Supprt> Manuals.
Connector for battery pack
MX-Door1-BAT
OUT–OUT1+ Theft protection /
Door opener
Theft protection
IN–OUT2+ Door sensor /
Door lock sensor
Door opener
IN2+BUS+ Door lock sensorMxBus+
IN1+BUS– Door switchMxBus–
MX-Door2-INT
31.815_EN_V1_09/2013

The HiRes Video Company
EN
www.mobotix.com
HiRes Video Innovations
The German company MOBOTIX AG is known as the leading pioneer in network camera technology and its
decentralized concept has made high-resolution video systems cost-ecient.
MX-DoorMaster: Quick Install
Operation: Keys and Signaling
2013 • Declaration of Conformity: www.mobotix.com> Support> Media Library> Certificates
Copyright © MOBOTIX AG 2013 • Made in Germany • Technical information subject to change without notice.
General Signals
State LED Left LED Signal Left LED Right LED Signal Right
Door closed and locked On On
Door closed and not locked On Short flash 1x every 2s
Door is open On O
Doorbell is currently pressed Short flash 1x every 0.5s
Missed doorbell
<5 min.: On, 1x/s briefly o
>5 min.: On, 1x/2s briefly
o
New mailbox message Flash 1x every 2s
User Actions
Action Key LED LED Signal Audio Notification
Open door Press for
3s RFlashes 3x in 3s,
then twice
1 beep/s, then twice
(acknowledge)
Doorbell o/on Press 1x LShort flash 1x
every 5s 1 beep (acknowledge)
Doorbell o/on
(entire system)
Press
quickly 2x LShort flash 2x
every 5s 2 beeps (acknowledge)
Acknowledge message
indicator
Press
briefly 1x
Adjust Volume
Action Key LED LED Signal Audio Notification
Start
(stop after 5s inactivity)
Press for
2s LShort flash 1x/s 1 beep, then twice
(acknowledge)
Volume – Press 1x LO 1 beep
Volume + Press 1x RShort flash 1x/s 1 beep
Adjust Doorbell Sound
Action Key(s) LED LED Signal Audio Notification
Start
(stop after 5s inactivity)
Press for
2s LShort flash 1x/s 1 beep, then twice
(acknowledge)
Switch
+Press
briefly 1x RShort flash 2x/s 1 beep
Sound – Press 1x LO 1 beep
Sound + Press 1x RShort flash 2x/s 1 beep
Special/Error States
State LED Left LED Signal Left
Device error On
Battery is empty Flash with 3s break
Power failure: Ready Ultra-short flash with 4s break
Notes
• Please follow the notes on installing and operating the device in the
IP Video Door Station System Manual
(www.mobotix.com in the Support> Manuals section). This manual also contains wiring diagrams for the
dierent scenarios.
• This device is intended for indoor use only and must not be used outdoors.
• Make sure to properly dispose of the rechargeable battery in this device.
• Only replace the battery pack using MOBOTIX order no. MX-Door1-BAT!
• Maximum torque for the cover screw: 0.4 Nm.
Dimensions
MOBOTIX MX-DoorMaster
MX-Door2-INT
LED right (R)
(blue)
LED left (L)
(green/red)
Door opener
(press for 3s)
Speaker
Doorbell
o/on
(press briefly)
80mm/3.15in
80mm/3.15in 41.5mm/1.63in
51mm/2.01in
Wall
Backup power supply of keypad and door
opener upon power failure for up to 60 hours!
Battery pack
MX-Door1-BAT
This manual suits for next models
2
Other Mobotix Door Opening System manuals
Popular Door Opening System manuals by other brands

PDQ
PDQ 5300 manual

Assa Abloy
Assa Abloy Besam SL500 user manual

Roto
Roto E-Tec DoorDrive Installation, maintenance and operation instructions

Pujol
Pujol Receptor REV Variocode Installation and adjustment instructions

ENFORCER
ENFORCER Enforcer Access SD-962AR-36A Specifications

HAUTAU
HAUTAU ATRIUM HS Mounting