manuals.online logo
Brands
  1. Home
  2. •
  3. Brands
  4. •
  5. Monessen Hearth
  6. •
  7. Remote Control
  8. •
  9. Monessen Hearth GG18NV User manual

Monessen Hearth GG18NV User manual

This manual suits for next models

7

Popular Remote Control manuals by other brands

Bircher Reglomat RC Duo 2 user guide

Bircher Reglomat

Bircher Reglomat RC Duo 2 user guide

Emerson RCBT100 owner's manual

Emerson

Emerson RCBT100 owner's manual

BILDA Element-6 user manual

BILDA

BILDA Element-6 user manual

Absima CR7P manual

Absima

Absima CR7P manual

Mitsubishi Electric PAR-32MAAG Instruction book

Mitsubishi Electric

Mitsubishi Electric PAR-32MAAG Instruction book

RCA RCRTBL08BE1 quick start guide

RCA

RCA RCRTBL08BE1 quick start guide

US Electronics NOVARI user guide

US Electronics

US Electronics NOVARI user guide

Panasonic EUR7622KB0 Operation guide

Panasonic

Panasonic EUR7622KB0 Operation guide

Bang & Olufsen Beo4 user manual

Bang & Olufsen

Bang & Olufsen Beo4 user manual

Marantz RC101 user guide

Marantz

Marantz RC101 user guide

FUTABA 9ZAP - PART2 manual

FUTABA

FUTABA 9ZAP - PART2 manual

HR Matic HR MULTI 3 quick start guide

HR Matic

HR Matic HR MULTI 3 quick start guide

Anritsu MP1777A Operation manual

Anritsu

Anritsu MP1777A Operation manual

Niles WVC100 Installation & operating guide

Niles

Niles WVC100 Installation & operating guide

Bang & Olufsen BEO6 Getting started

Bang & Olufsen

Bang & Olufsen BEO6 Getting started

GE 94901 instruction manual

GE

GE 94901 instruction manual

FUTABA R7108SB Full manual

FUTABA

FUTABA R7108SB Full manual

Invacare G91S user manual

Invacare

Invacare G91S user manual

manuals.online logo
manuals.online logoBrands
  • About & Mission
  • Contact us
  • Privacy Policy
  • Terms and Conditions

Copyright 2025 Manuals.Online. All Rights Reserved.

1
Monessen • Hi/Lo Variable Flame Height Kit/Remote Control Instructions • 4606-901 Rev. B • 06/18
• This kit must be installed by a qualied
service agency.
Hi/Lo Variable Flame Height Kit and Remote
Control Instructions
Models: GG18NV, GG18PV, GG24NV, GG24PV, NB18NV,
NB18PV, NB24NV, NB24PV
Kit Contents:
- Hi/Lo SIT Stepper Motor (820 NG-3.5 for Natural Gas,
820 LP-10 for Liquid Propane).
- Pro-Flame Receiver Kit.
- Pro-Flame Transmitter (Remote).
- Pro-Flame Wire Harnesses.
- Installation Instruction.
Tools Required:
- Gloves.
- Torx T20 Safety Driver.
- Small Flathead Screwdriver.
Check to make sure that all parts have been received
and are correct. If not, contact your dealer before
beginning installation.
CAUTION
Before installing kit:
• Shut off gas supply
• Allow unit to cool
This Hi/Lo kit shall be installed by a qualied service
agency in accordance with manufacture’s instructions.
If all information in these instructions is not followed
exactly, a fire, explosion or production of carbon
monoxide may result causing property damage, personal
injury or loss of life.
The qualied service agency is responsible for the proper
installation of this kit. The installation is not complete
until operation of the appliance is checked as specied
in the manufacturer’s instructions supplied with the kit.
LOGS MAY BE HOT TO THE TOUCH. HANDLE
THE LOGS WITH GLOVES AND PLACE THEM ON
A NONCOMBUSIBLE SURFACE WHEN THEY HAVE
BEEN REMOVED FROM THE UNIT.
WARNING
1. Remove the logs from the unit and set aside.
2. Using a Torx T20 driver, remove and discard the
regulator and rubber gasket in the face of the valve.
Refer to regulator instructions provided with the Hi/Lo
stepper motor included in your kit .
3. Using a Torx T20 driver, Install the Hi/Lo stepper motor
with rubber gasket from Hi/Lo kit. Make sure the gasket
is sealed properly.
4. Disconnect the two (2) female connectors for the log
switch from the TP/TH and TH terminals on the control
valve.
5. Connect the 14-pin female connector from the wire
harness provided with your kit to the 14-pin male
connector on the back of the receiver that is also
provided with your kit.
Monessen • Hi/Lo Variable Flame Height Kit/Remote Control Instructions • 4606-901 Rev. B • 06/182
6. Connect the two (2) ¼” female connectors to the valve.
The white wire connects to the TP/TH terminal and the
green wire connects to the TH terminal on the valve.
See Figure 1.
Figure 1. Installing
Remote Receiver
7. Connect the four-pin connector of the wire connected
to the control valve to the four-pin connector of the
wire harness connected to the back of the receiver.
8. Set the remote receiver inside your unit in place of the
log switch removed earlier.
9. After the batteries have been installed in the remote
and the receiver, move the three position slider switch
to “Remote” position.
10. Use the end of a paper clip, or other similar object, to
push in the hole marked “PRG: on the receiver front
(you should hear three beeps for conformation).
11. On the remote, push the ON button (you will hear four
beeps to conrm the synchronization of your device).
12. For further instructions, refer to the instruction sheet
included with the SIT Pro-ame remote.
13. Turn the gas on and using a soapy water solution
check for leaks.
14. Using the small athead screwdriver and a monometer,
check the manifold pressure for conformation 3.5” for
NG and 10” for LP.
15. Reinstall the logs per your installation instruction/use
and care manual.
Monessen, a brand of Hearth & Home Technologies
7571 215th Street West, Lakeville, MN 55044
www.monessenhearth.com
TP/TH TP TH
White
Green
Remote Wire
Connectors
Motor
Wires
Valve
Remote
Receiver