CLEANING SOLENOID VALVE
1. Unscrew the screws like the picture
2. Extract the rubber membrane.
3. Check if there are impurities and clean.
4. Clean the holes on the rubber membrane.
SOLENOID VALVE TECHNICAL DRAWING
G1/2
97,5
G1/2
SW23
ELECTRONIC MIXER TAP
POWER SUPPLY : 4x1,5V batteries AA
TECHNICAL DATA –INSTRUCTION FOR THE ASSEMBLAGE –PRECAUTIONS FOR USE
ZEUS003
Serie R
INFORMATIONS FOR THE USER
SPECIFICATIONS:
POWER SUPPLY
Alkaline batteries (4x1,5V AA)
MINIMUM WORKING PRESSURE
0,5 bar
MAXIMUM WORKING PRESSURE
4 bar
MAXIMUM WORKING TEMPERATURE
70°C
MINIMUM SENSING DISTANCE
0,5cm
MAXIMUM SENSING DISTANCE
15 cm
FLOW RANGE
5 l/min with 3 bar pressure
FLEXIBLES CONNECTION
G 1/2" F
FLEXIBLES LENGHT
35 cm
WARNING LOW BATTERY
yes
VANDAL PROOF SYSTEM
yes
ANTI-LEGIONELLA SYSTEM
yes
ASSEMBLY INSTRUCTIONS:
In case of new plumbing , always proceed to drain the pipes before
installation.
1. Turn off the water supplies.
2. Screw the stay bolt (H) to the mixer tap (G). Insert the base (I), the O-Ring (J)
and screw the flexibles (B) to the mixer tap (G).
3. Place the tap on the sink by passing the flexibles (B) and the sensor cables
(C1,C2) in the sink hole, staring it with the fixing kit.
4. Screw the swinging spout (F) to the tap (G).
5. Connect the solenoid valves (D) to the flexibles (B) according to the input of the
water (see pic. 1).
6. Connect the connectors (K) to the solenoid valves (D), paying attention to the
polarity of the cables (see pic. 1).
7. Secure the battery holder (E) on the wall under the sink, using the velcro and
making sure that the cable outlet is facing downward. (see pic. 2)
8. Insert the 4 alkaline batteries in the battery holder (E). Pay attention to the poles
+ and -.
9. Conect the cable (C1)to the battery holder (E).
FUNCTIONING:
The infrared sensor (A) identifies the presence of the hands and the valve begins to
provide the water till the sensor will no more detect the hands in front of the sensor
or until the expiration of the maximum time of closing (VANDAL PROOF SYSTEM).
If the infrared system detects an object for 5 minutes, the system cut off the water
supply until the object will not be removed. Once the foreign object has been
removed, the tap will resume regular operation.
The low battery is indicated by flashing red LED light with increasing speed.
The solenoid valve closes and the system hangs waiting for the battery replacements.
After 24 hours of non-use, the tap is automatically activated to prevent the
LEGIONELLA bacterium (ANTI-LEGIONELLA SYSTEM).
Failure to supply water, check that the batteries are charged and/or correctly
positioned.
The operation of the tap is guaranteed only with water free of impurities, therefore it
is important install the faucet filters.
FAILURE IN FOLLOW THE INFORMATIONS CONTAINED IN THIS LEAFLET
WILL INVALIDATE THE WARRANTY
Battery holder
D
A
B
C1
E
F
G
H
C2
I
J
pic. 2
K
Serie R
Serie R
Solenoid valve
pic. 1
A
B
C
D
E
F
1 2 3 4 5 6 7 8
1 2 3 4 5 6 7 8
A
B
C
D
E
F
Rev. 00
55
O
45
O
92,5
236
160
265
20
28
O
G1/2
40
O
76
G1/2
97,5
G1/2
SW23
6
SW23
ALIMENTAZIONE : BATTERIE ALCALINE (4x1,5v AA)
POWER SUPPLY : Alkaline batteries (4x1,5V AA)
ZEUS003

Popular Control Unit manuals by other brands

auto maskin DCU 205 user manual

auto maskin

auto maskin DCU 205 user manual

Siemens CP 443-5 Extended manual

Siemens

Siemens CP 443-5 Extended manual

Siemens EVG4U10E Series Mounting instructions

Siemens

Siemens EVG4U10E Series Mounting instructions

KIESELMANN 5629 Series operating instructions

KIESELMANN

KIESELMANN 5629 Series operating instructions

IOtech Personal Daq/3000 user manual

IOtech

IOtech Personal Daq/3000 user manual

salmson SC-L Installation and starting instructions

salmson

salmson SC-L Installation and starting instructions

Nibe SMO 20 user guide

Nibe

Nibe SMO 20 user guide

IBA ibaMS4xUCO manual

IBA

IBA ibaMS4xUCO manual

schmersal SRB 301AN operating instructions

schmersal

schmersal SRB 301AN operating instructions

DSC ESCORT558OTC installation manual

DSC

DSC ESCORT558OTC installation manual

Balluff BNI EIP-50 105-Z015 Series Connection guide

Balluff

Balluff BNI EIP-50 105-Z015 Series Connection guide

Asutec ASUEL-30 operating manual

Asutec

Asutec ASUEL-30 operating manual

Avalue Technology ESM-TGH user manual

Avalue Technology

Avalue Technology ESM-TGH user manual

Moen 3371 Service manual

Moen

Moen 3371 Service manual

Kemo Electronic M206 manual

Kemo Electronic

Kemo Electronic M206 manual

ADTRAN Quad T1 user manual

ADTRAN

ADTRAN Quad T1 user manual

Huawei ME936 Application guide

Huawei

Huawei ME936 Application guide

Keyvalve KP-28 operating & maintenance manual

Keyvalve

Keyvalve KP-28 operating & maintenance manual

manuals.online logo
manuals.online logoBrands
  • About & Mission
  • Contact us
  • Privacy Policy
  • Terms and Conditions

Copyright 2025 Manuals.Online. All Rights Reserved.