3-IN-1 Metal ,Live Wire And Stud Detector
1. ON/OFF Button.
2. Mode selector switch.
3. LCD display.
4. AC indicator.
POWER SUPPLY
The tools require one 9 volt battery
to operate.
BATTERY INSTALLATION
1. Open battery door on back of
case.
2. Connect a 9-volt battery to battery
clip.
3. Insert battery into case and
replace battery door.
Turning the power on/off
On : Press and hold the on/off button on
left side.
Off :Release on/off button.
Stud Scan or Deep Scan modes
Stud Scan mode for depths to about 3/4
in. (18mm).
Deep Scan mode for Depths to about
11/2 in(30mm).
Position the Scanner Flat against the
Wall. Select mode. Press and hold on/off
button.
Sounds off the auto finish.
Slowly slide unit horizontally across
wall, right of left.
When full bars appears on the LCD and
steady tone sounds, you have located the
edge of the stud. Mark this spot.
Continue holding on/off button in and
scan beyond the marked spot until bars
disappears.
Model 59124
Without releasing on/off button, slide
scanner in reverse direction to locate the
other edge of stud. Mark this second
spot. Middle of stud is centered between
the two marks.
Calibrating and Scanning in metal
Scan.
Select metal mode. Press and hold
on/off button. Then calibrate scanner in
air. Away from metal objects, until the
sounds off. Place scanner flat on the
surface.
While holding in on/off button, slowly
move unit randomly to locate target
LCD screen indicates proximity to
metal, with center bar indicating closest
proximity. Mark this spot.
Continue scanning beyond the marked
spot to detect width of target. If target is
wide, reverse to locate and mark the
other edge. Avoid sawing or drilling
between the two marks. Widths will
vary from single peak for narrow rebar
to wide area for metal studs, I beams ,
junction boxes.
Scanning in AC mode
AC depths to about 2 in.
Select AC scan mode to determine
position of hot wires. Begin by placing
the scanner at some position away from
hot wiring.
While holding in the on/off button,
slowly slide unit across the wall. AC
indicator will appear on LCD if a hot
wire is nearby. LCD display indicates
proximity to hot wire all bars indicating
closest proximity. Mark this mark.
The scanner detects from 90V to 250 V
at 50 to 60 Hz AC in a HOT electrical
wire. The voltage detection feature
works continuously in all modes for
safety.

This manual suits for next models

1

Popular Security Sensor manuals by other brands

Abus FUBW50022 user manual

Abus

Abus FUBW50022 user manual

Paradox ENVY NVX80 installation guide

Paradox

Paradox ENVY NVX80 installation guide

WindowMaster WLA 331 Operation manual / technical information

WindowMaster

WindowMaster WLA 331 Operation manual / technical information

Sensor Switch WSX Series instructions

Sensor Switch

Sensor Switch WSX Series instructions

GSM Activate ALARM PRO 20 quick start guide

GSM Activate

GSM Activate ALARM PRO 20 quick start guide

C.P. Electronics MWS5-DD-SA-C installation guide

C.P. Electronics

C.P. Electronics MWS5-DD-SA-C installation guide

Multitech RBS3010NA08BN00 user guide

Multitech

Multitech RBS3010NA08BN00 user guide

Contro l4 Movement Detector 220 SM user guide

Contro l4

Contro l4 Movement Detector 220 SM user guide

ACU-RITE 592TXR instruction manual

ACU-RITE

ACU-RITE 592TXR instruction manual

C.P. Electronics MWS1A-PRM-VFC installation guide

C.P. Electronics

C.P. Electronics MWS1A-PRM-VFC installation guide

AU Tool SDT106 user manual

AU Tool

AU Tool SDT106 user manual

Green Brook Orion Series quick start guide

Green Brook

Green Brook Orion Series quick start guide

Abus FUBW35000A manual

Abus

Abus FUBW35000A manual

Optex AP-360B installation instructions

Optex

Optex AP-360B installation instructions

Bosch WEU PDO Multi Original instructions

Bosch

Bosch WEU PDO Multi Original instructions

Texecom Veritas Reflex INS156-7 installation manual

Texecom

Texecom Veritas Reflex INS156-7 installation manual

FPI RLGD-100 user manual

FPI

FPI RLGD-100 user manual

BUSCH TAPIR instruction manual

BUSCH

BUSCH TAPIR instruction manual

manuals.online logo
manuals.online logoBrands
  • About & Mission
  • Contact us
  • Privacy Policy
  • Terms and Conditions

Copyright 2025 Manuals.Online. All Rights Reserved.