v3.1 REV. 10/2023
NO
987654321
INHI
NC
8K2
0_SIG
+ OSE
- GND
+ PV
OPERATION/PROGRAMMING MANUAL EN
MX14
The MX14 is a emitter that communicates wirelessly with the MR14 receiver, up to 50m in the
open, powered by batteries or rechargeable batteries by solar panel.
Allows the connection of an 8k2 safety edge, optical sensor and dry contact safety device,
or the use of an accelerometer.
TECHNICAL CHARACTERISTICS
• Power supply
.V AA batteries or .V AA rechargeable batteries
•
Solar panel V mA monocrystalline
• Working frequency .MHz to .MHz
• Reach in open field m
• Dimension
x x (mm)
• Protection degree
IP
INPUTS / OUTPUTS
ATTENTION: ALWAYS CHECK THE CORRECT ORIENTATION WHEN APPLYING THE BATTERY TO THE DEVICE.
Place the jumper in the position
indicated for the used battery
(BATT or SOLAR).
Battery Mode (BATT)
3.6V lithium-ion batteries
with category AA.
Solar Mode (SOLAR)
Rechargeable lithium-ion
batteries, powered by the solar
panel, with a rating of 3.7V with
category AA.
ENERGY
BATTERY DURATION:
years in ECO mode;
In NORMAL mode the
use of a solar panel is
recommended.
1 2
ON
NO
987654321
INHI
NC
8K2
GND
ANT
J1 J2
J1 J2
B AT T
SOLAR
0_SIG
+ OSE
- GND
+ PV
The accelerometer is not included in the kit.
The accelerometer (tilt sensor) allows you to measure the level of tilt and speed of your vibrations,
allowing you to detect obstacles during door or gate maneuvers.
To use this sensor, you must put Dipper2 to ON.
AUTOMATIC SENSOR PROGRAMMING:
1 • Press the PROG button for 5 seconds to enter the programming mode.
2 • Carry out opening and closing maneuvers.
3 • After closing, you can change the FORCE and/or TILT values by pressing the respective button as
many times as necessary until reaching the desired value (the level is identified by the number of
times the respective LED flashes).
4 • Press the PROG button again to exit the programming mode.
CHANGE THE SENSOR'S FORCE AND TILT VALUES:
1 • Press the PROG button once.
2 • Pressing the FORCE and/or TILT button as many times as necessary until reaching the desired value
(the level is identified by the number of times the respective LED flashes)
3 • Press the PROG button again to exit programming mode.
INSERT IN THIS
POSITION
ACCELEROMETER - Inclination Sensor
9
•
8
•
7
•
NO
COM
INHI
Input for dry contact safety devices
Common
NO input for inhibit signal
6
•
5
•
8K2/NC
8K2
Input for 8k2 resistive safety rubber.
NOTE
• To use 8k2 Dipper 1 and 2 must be OFF. To use NC, Dipper 1 must be ON and Dipper 2
must be OFF.
4
•
3
•
O_SIG
+ OSE
Optical sensor signal
Optical sensor power supply
2
•
1
•
GND
+ PV Solar panel and optical sensor common
Photovoltaic solar panel positive (max. 4V)
It is possible to invert the polarity of the auto test channel inputs through the MR14 pin headers.