Motorline professional MR14 User manual

1 2 3
ON
LED1 LED2 LED3 LED4 LED5 LED6 LED7 LED8
JOIN SEL
v2.3 REV. 02/203
1
3
2
ON
ON
ON
ON
ON
ONOFF
OFF
OFF
OFF
ON ON
OFFOFF
OFF
ON
1 2 3 4 5 6 7 8 9 10 11 12
MR14
OPERATION / PROGRAMMING MANUAL EN
The MR14 receiver is a wireless receiver for managing multiple MX14 emitters.
When receiving information from the emitter, it communicates with the automation
control board via cable, so that the automation can be stopped or reversed.
TECHNICAL CHARACTERISTICS
• Power Supply -Vdc / -Vac
• ECO Inputs
/V
• Relay Vdc A/Vac .A
• Working frequency Self-adjusting MHz
• Memory for emitters
• Range in open field m
• Dimension
x x (mm)
• Protection degree
IP
AES encryption
Basic operation:
Dipper 1 → ON;
Dipper 2 → OFF;
Dipper 3 → OFF.
ACTIVED
BUZZER DEACTIVATED
BUZZER
1
•
2
•
3
•
NC
COM
8k2
Relay output NO channel
>the output is active when any channel 1 emitter is in error
(ex: Door hit an obstacle, communication failed or the battery ran out).
The NC or NO output must be connected to the control board.
4
•
5
•
6
•
NC
COM
8k2
Relay output NO channel
>the output is active when any channel 2 emitter is in error
(ex: Door hit an obstacle, communication failed or the battery ran out). The
NO or NC output must be connected to the control board.
7
•
8
•
9
•
10 •
CH1
COM
CH2
COM
/V mode input
>used to activate channel 1 or 2 in ECO mode (Dipper 1 OFF). The control
board must activate this input when the door starts to move.
11
•
12
•
+
-
/Vdc/ac power supply
LEDs
LED, LED, LED e LED - memory position indicators to be programmed for channel
LED, LED, LED e LED - memory position indicators to be programmed for channel
INPUTS / OUTPUTS AND LEDS
DIPPER
WORKING
MODE ALWAYS
ON
30 SECONDS 7 SECONDS
The Auto test is an external signal that checks the relay
(there is one for each channel).
Dipper 1 allows you to select the desired type of operation.
• OFF – Working mode - R
ecommended for the optical
sensor
> The working mode allows you to activate/
deactivate the optical sensor. When the optical
sensor is active, a communication test takes place.
Communication is also tested every 7 or 30 seconds.
This mode allows energy saving.
•ON – "Always ON" mode - Recommended with 8k2,
NC, NO or tilt sensor
>
The communication is tested every 7 or 30 seconds,
according to the position of dipper 2.
In dipper 2 can set the self check period.
> It makes automatic recognition every 30 seconds or
every 7 seconds.
• OFF – 30 seconds
•ON – 7 seconds
Dipper 3 • Buzzer (beep)
• OFF – Active buzzer
•ON – Deactivated buzzer
Graphic representation of the Auto Test:
WORKING MODE
"ALWAYS ON" MODE
Power supply
Auto test
Relay output
Power supply
Auto test
Relay output
DELAY DELAY
DELAY DELAY

1
2 3
ON
LED1 LED2 LED3 LED4 LED5 LED6 LED7 LED8
JOIN SEL
81mm
66mm
20mm
BUTTONS AND LEDS
SEL → BUTTON TO SELECT THE EMITTER POSITION TO ADD/CHANGE:
>The selected LED is flashing;
>Each click increases a position, if you pass the last position it returns to LED ;
>If you do not press any button for seconds, the selected LED turns off and is no longer in
"selection mode".
JOIN → BUTTON TO ENTER OR EXIT THE "ADD EMITTER" MODE:
>Press this button after selecting the position to add/change;
>To exit without adding a new emitter, press this button again.
• LED 1 to 8 → MEMORY POSITION INDICATORS TO PROGRAM:
ON – Emitter programmed in this position;
OFF – Free position;
Blink – Emitter programmed, but with error.
• LED JOIN → MEMORY POSITION INDICATORS TO PROGRAM:
ON – Programming mode active;
OFF – Programming mode inactive.
• PIN HEADERS →
CHANGE CHANNEL:
PROGRAMMING EMITTER:
1
• Press SEL button to select the position where you want to program the emitter.
2
• Press the JOIN button to open the selected position (the position LED will flash quickly)
3
• Press the JOIN button of the desired emitter.
4
• The position LED stops flashing and stays on, signaling the success of the operation.
NOTE • If a emitter is already stored in that position, the new emitter will replace the previously programmed emitter.
DELETE EMITTER:
1
• Press the emitter's JOIN button until the transmitter's JOIN LED flashes once.
OR
1
•
Press SEL button to select the position you want to delete.
2
•
Press the JOIN button to open the selected position (the position LED will flash quickly).
3
•
Press the JOIN button again to delete the emitter from that position.
4
•
The position LED stops flashing and goes off, signaling the success of the operation.
APPLICATION INSIDE THE MOTOR:
>
Insert the device into the motor cover, to facilitate
connections to the control board and to avoid infiltration
of moisture.
INSTALLATION:
>
The device can be applied in other locations. Secure
with screws.
NOTE
•
It is not advisable to install inside an iron box as it
can create noise in the communication.
PRODUCT INSTALLATION
If the jumpers are changed, the system will reset all previously memorized devices.
NOTE • Whenever more than one MR14 is used in
the same place, the selected channels must be
different from each other. Otherwise interference
may occur.
CH CH
Channel 1
CH CH
Channel 2
CH CH
Channel 3
CH CH
Channel 4

1 2 3
ON
LED1 LED2 LED3 LED4 LED5 LED6 LED7 LED8
JOIN SEL
1 2
ON
NO
987654321
INHI
NC
8K2
GND
ANT
B AT T
SOLAR
0_SIG
+ OSE
- GND
+ PV
RY24V G B
V+
R
G
B
RG
ENLELA +V24V
1 2
24V
1 32 4 5
ENLELA +V
1 32 4 5
24V YRGB
Check the manual for your control board to identify the entries corresponding to the one indicated in the diagram.
1 • LA → Security band input
2 • LE → Photocells input
3 • (not used)
4 • (not used)
5 • COM
1 •24V output (minimum → 100mA)
2 •COM
1 • 24V → 24V output
2 • (not used)
3 • R → 0V output - activated
during closing maneuvers
4 • G → 0V output - activated
during opening maneuvers
5 • B → 0V output - activated
during pause time
CONNECTION SCHEME
RGB LIGHT
MR1
CONTROL BOARD
MX1
Dry contact safety devices NO
Optical sensor
Signal inhibitor
• When closed (NC), the emitter will
ignore signals from inputs k NO/
NC and optical sensor.
k or NC resistive safety rubber
• To use, remove the resistance that comes
from the factory at inputs and . Solar panel
Table of contents
Other Motorline professional Receiver manuals