motorol MBP66N User manual

Quick Start Guide
For a full explanation of all features and instructions, please refer to the User’s Guide
(available for download from www.motorolastore.com).
1. Setting up the 3-in-1 non-contact baby Thermometer
1. The key to obtaining accurate readings is a clean sensor. To
clean the sensor, use a cotton swab slightly moistened with
alcohol to gently wipe its surface, and then immediately
wipe dry using a clean cotton swab. Wait at least 20
minutes to make sure that the sensor is completely dry
before taking temperature.
2. Skin surface lipids on the forehead may cause an inaccurate
measurement, so make sure the forehead is clean. If you
clean the forehead, please keep waiting a further 5 to 10
minutes before measuring.
3. If the temperature of the storage area diers greatly from that of the measuring
area, please wait until the thermometer temperature has equalized to the room
temperature, about 30 minutes, prior to use.
4. Gently slide the battery cover back and install 2 x 1.5V
AAA size alkaline batteries (which can be found inside
the packaging) according to the proper polarity, slide
the battery cover back, press the button to turn the
thermometer on.
2. How to measure forehead temperature
Make sure the probe is clean before measuring.
1. Press the button to power on the thermometer. When
the device is ready, ‘ - - ’ will appear on the screen.
2. Press once the button to select the Forehead
Mode.
3. Position the thermometer about 3cm (around 1 inch) from
the center of the forehead with the sensor aimed between
the eyebrows.
4. Press once the button, when the measurement is
completed, it will end with a confirmation tone.
5. If the temperature measurement is below 380C/100.40F, a symbol
will be appeared on display and the Green LED will be on. If the
reading is 380C/100.40F or above, symbol will be appeared on
display and the Red LED will be on.
6. About 30 seconds after use, the thermometer will automatically beep
and shut o.
Note:
• High Temperature Alarm appears in both Forehead Mode and Forehead/Silent
Mode. When taking a patient’s temperature, ensure that the thermometer is in Forehead
Mode; the symbol appear on the display.
• If the skin is covered with hair, sweat, or dirt, clean the area and wait 10 minutes before
taking a measurement.
• Ensure that the thermometer is held firmly during measurement and that the patient does
not move until the measurement is completed, movement may impact the measurement.
3. General Information
If your product is not working properly, read this Quick Start Guide or the User’s Guide.
Contact Customer Service:
Live Chat: motorolastore.support/en
E-mail: support@motorolastore.com
Consumer Products and Accessories Limited Warranty (“Warranty”)
Thank you for purchasing this Motorola branded product manufactured under license by
Binatone Electronics International Ltd. (“BINATONE”).
What Does This Warranty Cover?
Subject to the exclusions contained below, BINATONE warrants that this Motorola
branded product (“Product”) or certified accessory (“Accessory”) sold for use with this
product is manufactured to be free from defects in materials and workmanship under
normal consumer usage for the period outlined below. This Warranty is your exclusive
warranty and is not transferable.
Who Is covered?
This Warranty extends only to the first consumer purchaser, and is not transferable.
What Will BINATONE Do?
BINATONE or its authorized distributor, at its option and within a commercially
reasonable time, will at no charge repair or replace any Products or Accessories that
does not conform to this Warranty.
We may use functionally equivalent reconditioned/refurbished/pre-owned or new
Products, Accessories or parts.
What Other Limitations Are There?
ANY IMPLIED WARRANTIES, INCLUDING WITHOUT LIMITATION THE IMPLIED
WARRANTIES OF MERCHANTABILITY AND FITNESS FOR A PARTICULAR PURPOSE,
SHALL BE LIMITED TO THE DURATION OF THIS LIMITED WARRANTY, OTHERWISE THE
REPAIR OR REPLACEMENTPROVIDED UNDER THIS EXPRESS LIMITED WARRANTY
IS THE EXCLUSIVE REMEDY OF THE CONSUMER, AND IS PROVIDED IN LIEU OF ALL
OTHER WARRANTIES, EXPRESS OR IMPLIED.
IN NO EVENT SHALL MOTOROLA OR BINATONE BE LIABLE, WHETHER IN CONTRACT
OR TORT (INCLUDING NEGLIGENCE) FOR DAMAGES IN EXCESS OF THE PURCHASE
PRICE OF THE PRODUCT OR ACCESSORY, OR FOR ANY INDIRECT, INCIDENTAL,
SPECIAL OR CONSEQUENTIAL DAMAGES OF ANY KIND, OR LOSS OF REVENUE OR
PROFITS, LOSS OF BUSINESS, LOSS OF INFORMATION OR OTHER FINANCIAL LOSS
ARISING OUT OF OR IN CONNECTION WITH THE ABILITY OR INABILITY TO USE
THE PRODUCTS OR ACCESSORIES TO THE FULL EXTENT THESE DAMAGES MAY BE
DISCLAIMED BY LAW.
Some jurisdictions do not allow the limitation or exclusion of incidental or consequential
damages, or limitation on the length of an implied warranty, so the above limitations or
exclusions may not apply to you. This Warranty gives you specific legal rights, and you
may also have other rights that vary from one jurisdiction to another.
Products Covered Length of Coverage
Consumer Products One (1) year from the date of the products, original
purchase by the first consumer purchaser of the product.
Consumer Accessories Ninety (90) days from the date of the Accessories, original
purchase by the first consumer purchaser of the product.
Consumer Products and
Accessories that are
Repaired or Replaced
The balance of the original warranty or for Ninety (90)
days from the date returned to the consumer, whichever is
longer.
US_EN
CARE
3-in-1 non-contact
baby thermometer
Model: MBP66N
1inch/3cm
F
1inch/3cm
F

Manufactured, distributed or sold by Binatone Electronics International LTD.,
ocial licensee for this product. MOTOROLA and the Stylized M logo are
trademarks or registered trademarks of Motorola Trademark Holdings, LLC.
and are used under license. All other trademarks are the property of their
respective owners. © 2020 Motorola Mobility LLC. All rights reserved.
Printed in China
Version 1.0
Exclusions
Normal Wear and Tear. Periodic maintenance, repair and replacement of parts due to
normal wear and tear are excluded from coverage.
Batteries. Only batteries whose fully charged capacity falls below 80% of their rated
capacity and batteries that leak are covered by this Warranty.
Abuse & Misuse. Defects or damage that result from: (a) improper operation, storage,
misuse or abuse, accident or neglect, such as physical damage (cracks, scratches, etc.)
to the surface of the product resulting from misuse; (b) contact with liquid, water, rain,
extreme humidity or heavy perspiration, sand, dirt or the like, extreme heat, or food; (c)
use of the Products or Accessories for commercial purposes or subjecting the Product or
Accessory to abnormal usage or conditions; or (d) other acts which are not the fault of
MOTOROLA or BINATONE, are excluded from coverage.
Use of Non-Motorola branded Products and Accessories. Defects or damage that result
from the use of Non-Motorola branded or certified Products or Accessories or other
peripheral equipment are excluded from coverage.
Unauthorized Service or Modification. Defects or damages resulting from service,
testing, adjustment, installation, maintenance, alteration, or modification in any way
by someone other than MOTOROLA, BINATONE or its authorized service centers, are
excluded from coverage.
Altered Products. Products or Accessories with (a) serial numbers or date tags that
have been removed, altered or obliterated; (b) broken seals or that show evidence
of tampering; (c) mismatched board serial numbers; or (d) non-conforming or non-
Motorola branded housings, or parts, are excluded from coverage.
Communication Services. Defects, damages, or the failure of Products or Accessories
due to any communication service or signal you may subscribe to or use with the
Products or Accessories is excluded from coverage.
How to Obtain Warranty Service or Other Information ?
To obtain service or information, please call:
ULive Chat: motorolastore.support/en
E-mail: support@motorolastore.com
You will receive instructions on how to ship the Products or Accessories at your expense
and risk, to a BINATONE Authorised Repair Center. To obtain service, you must include:
(a) the Product or Accessory; (b) the original proof of purchase (receipt) which includes
the date, place and seller of the Product; (c) if a warranty card was included in your
box, a completed warranty card showing the serial number of the Product; (d) a written
description of the problem; and, most importantly; (e) your address and telephone
number.
These terms and conditions constitute the complete warranty agreement between you
and BINATONE regarding the Products or Accessories purchased by you, and supersede
any prior agreement or representations, including representations made in any literature
publications or promotional materials issued by BINATONE or representations made by
any agent, employee or sta of BINATONE, that may have been made in connection with
the said purchase.
Disposal of the Device (Environment)
At the end of the product life cycle, you should not dispose of this product
with normal household waste. Take this product to a collection point for the
recycling of electrical and electronic equipment. The symbol on the product,
user’s guide and/or box indicates this obligation.
By taking end-of-life products to a recycling point, you are ensuring that some of the
product materials can be re-used. By reusing some parts or raw materials from used
products, you make an important contribution to the protection of the environment.
Please contact your local authorities should you require additional information on the
collection points in your area.
IMPORTANT INFORMATION REGARDING ELECTROMAGNETIC
COMPATIBILITY(EMC)
With the increased number of electronic devices such as PC’s and mobile (cellular)
telephones, medical devices in use may be susceptible to electromagnetic interference
from other devices. Electromagnetic interference may result in incorrect operation of
the medical device and create a potentially unsafe situation.
Medical devices should also not interfere with other devices.
In order to regulate the requirements for EMC (Electro Magnetic Compatibility) with
the aim to prevent unsafe product situations, the IEC 60601-1-2:2014 standard has
been implemented. This standard defines the levels of immunity to electromagnetic
interferences as well as maximum levels of electromagnetic emissions for medical
devices. Medical devices manufactured by AViTA Corporation. conform to this IEC
60601-1-2:2014 standard for both immunity and emissions.
Nevertheless, special precautions need to be observed:
The use of accessories and cables other than those specified by manufacturer, with
the exception of cables sold by manufacturer as replacement parts for internal
components, may result in increased emission or decreased immunity of the device.
• The medical devices should not be used adjacent to or stacked with other
equipment. In case adjacent or stacked use is necessary, the medical device
should be observed to verify normal operation in the configuration in which it
will be used.
• Refer to further guidance below regarding the EMC environment in which the
device should be used.
Model name: NT17
Ref. no. MBP66N
Standard Specification for Infrared Thermometer: ASTM E 1965-98 : 2016
China Manufacturing License(s) : SSYJXSCX20040018
Registration Certificate(s) : SXZZ20182200808
Manufacturer : AViTA (WuJiang) Co.LTD.
Add.: No. 858, Jiao Tong Rd., Wujiang Economic Development Zone, Suzhou City ,
Jiangsu Province, P.R.C.
Tel: +86-512-8207-8288
Made in China
Download User Guide from website: www.motorolastore.com/support
ȭ
ȭ
%
N6G
N6G
Table of contents
Popular Baby Accessories manuals by other brands

Graco
Graco FastAction Fold owner's manual

GOGO KIDZ
GOGO KIDZ Travelmate QRKID2 Instructions for use

Philips AVENT
Philips AVENT AVENT SCF125/12 Specification sheet

Emmaljunga
Emmaljunga Sento MAX Instructions/service manual

Fisher-Price
Fisher-Price CBV48 quick start guide

Project Nursery
Project Nursery Sleepy Sloth quick start guide