Motorola Air Conditioners User manual


11
17
18
27
28
1
4
5
6
7

1

2

3

NAMES OF PARTS
No. Description
1
2
Front panel
Air filter
Optional filter (if installed)
3
Terminal block cover
4
Emergency button
5
6
LED Display
Signal receiver
7
Airflow direction louver
8Deflectors
9
Remote controller
10
Note: the above figures are only intended to be a
simple diagram of the appliance and may not
correspond to the appearance of the units that
have been purchased.
No. Description
13 Air outlet grill
Terminal block cover
14
gas valve
15
liquid valve
16
11
Indoor unit rating label ( )Stick position optional
17
Outdoor unit rating label
12
Ionizer (if installed)generator
13
15
16
17
INDOOR UNIT
4
OUTDOOR UNIT
12-3
6
4-5
9
11 8
10 7
14
12
INDOOR UNIT
OUTDOOR UNIT
10

INDOOR UNIT DISPLAY
The shape and position of switches and indicators may be different according to the model, but their
function is the same.
According to the model, it may only show 2 numbers on the indoor display though there are 3 numbers
on display of the remote controller .(Example: it is on the display of the remote controller but
on the indoor display )
4
2
5
/O
1
2
5
3
4
1 2 345
3
12
3
54
No.
Led Function
POWER This symbol appears when the unit is power on
1
2
3
4
5
Temperature display (if present)
/Error code
(1) Lights up during Timer operation when
the air conditioner is operational
(2)Displays the malfunction code when fault
occurs.
SLEEP mode
Lights up during Timer operation.
The symbol appears when the unit is turned
on, and disappear when the unit is turned off.
SLEEP
TIMER
RUN
3
4
2
1245
3

Emergency
button
The emergency button in some models could be on
the right part of the unit under the front panel.
front panel
front panel
6

REMOTE CONTROLLER
To select the mode of operation(AUTO COOL DRY FAN HEAT)
To activate/deactivate the GEN function which enables the unit run in the
set current level,cycle as below OFF L3 L2 L1
Press this button to activate/deactivate the Super function which enables the
unit to reach the preset temperature in the shortest time.
To decrease temperature, time setting or choose the function.
To increase temperature , time setting or choose the function.
To turn on or off the air conditioner .
To select the fan speed of auto/mute/low/mid-low/mid/mid-high/high/
turbo , cycle as below.
8
10
6
7
9
MODE
TURBO
1
2
3
4
FAN
5
No.
Button Function
7
OPTION To activate or deactivate optional function(Check below table).
ON/OFF
Mode OPTIONS
AUTO
COOL
DRY
FAN
HEAT
AUTO
COOL
DRY
FAN
HEAT
ON
OFF
To activate the swing of horizontal flap(up/down) or deactivate it.
Youwill hear abeep when youpress the following buttons orselect the following optional functions,
though the actualmodel haven't this function, we express our apologies:
(Optional Function: COMFORTABLE COOLING airflow)
(Optional Function: COMFORTABLE HEATING airflow)
HEALTH (Optional Function: generate the ionizer)
(button: SWING LEFT/RIGHT)
To activate the swing of vertical flap(left/right) or deactivate it.
Flashing
Press this button to activate/deactivate the ECO function .
ECO
(Optional Function: 8 Heating)
8 CH (Optional Function: Wide-angle air supply)
O
TIMER DISPLAY HEALTH I FEEL 8 C H
O
TIMER DISPLAY HEALTH SLEEP MILDEW I FEEL 8 C H
O
TIMER DISPLAY HEALTH MILDEW I FEEL 8 C H
O
TIMER DISPLAY HEALTH I FEEL 8 C H
O
TIMER DISPLAY HEALTH SLEEP I FEEL 8 C H
O
CLEAN TIMER DISPLAY HEALTH I FEEL 8 C H
O
CLEAN TIMER DISPLAY HEALTH SLEEP MILDEW I FEEL 8 C H
O
CLEAN TIMER DISPLAY HEALTH MILDEW I FEEL 8 C H
O
CLEAN TIMER DISPLAY HEALTH I FEEL 8 C H
O
CLEAN TIMER DISPLAY HEALTH SLEEP I FEEL 8 C H

8
AUTO COOL DRY
FAN HEAT ECO
SLEEP TIMER I FEEL
HEALTH MILDEW
CLEAN DISPLAY 8 CH
WIND FREE
GEN MODE
7
3
1
9
5
8
4
2
10
6
Youwill hear abeep when youpress the following buttons orselect the following optional functions,
though the actualmodel haven't this function, we express our apologies:
(Optional Function: COMFORTABLE COOLING airflow)
(Optional Function: COMFORTABLE HEATING airflow)
HEALTH (Optional Function: generate the ionizer)
(button: SWING LEFT/RIGHT)
(Optional Function: 8 Heating)
8 CH (Optional Function: Wide-angle air supply)

REMOTE CONTROLLER
Remote controller DISPLAY
Meaning of symbols on the liquid crystal display
9
1
2
3
4
5
6
7
8
9
10
11
12
13
14
Mode Cooling indicator
Mode Dry indicator
Mode Fan indicator
Mode Heating indicator
Fan speed indicator:
Auto/low/mid-low/mid/mid-high/high
15
SUPER indicator
16
17
Mute indicator
18
Flap swing angle indicator
19
Temperature indicator
Meaning
No. Symbols
Deflector swing angle indicator
Comfortable cooling airflow indicator
I FEEL
SLEEP
HEALTH
DISPLAY
MILDEW
8 CH
CLEAN
WIND FREE
GEN MODE
Flashing
Timer indicator
Single indicator
Child Lock function indicator
Battery indicator
Mode Auto function indicator
TIMER
Comfortable heating airflow indicator
Optional functions indicator
flashing
Youwill hear abeep when youpress the following buttons orselect the following optional functions,
though the actualmodel haven't this function, we express our apologies:
(Optional Function: COMFORTABLE COOLING airflow)
(Optional Function: COMFORTABLE HEATING airflow)
HEALTH (Optional Function: generate the ionizer)
(button: SWING LEFT/RIGHT)
(Optional Function: 8 Heating)
8 CH (Optional Function: Wide-angle air supply)
TIMER

10
Replacement of Batteries
Remove the battery cover plate from the rear of the remote controller,
by sliding it in the direction of the arrow.
Install the batteries according the direction (+and -)shown on the Remote
Controller.
Reinstall the battery cover by sliding it into place.
Use 2 LRO 3 AAA (1.5V) batteries . Do not use rechargeable
batteries . Replace the old batteries with new ones of the same
type when the display is no longer legible.
Do not dispose batteries as unsorted municipal waste. Collection
of such waste separately for special treatment is necessary.
1. Direct the remote controller toward the Air conditioner.
2. Check that there are no objects between the remote control
and the Signal receptor in the indoor unit.
3. Never leave the remote controller exposed to the rays of the sun.
4. Keep the remote controller at a distance of at least 1m from the
television or other electrical appliances.
Note
Child-lock:
Press and
Togetherto active
DisplayON/OFF:
Longpress ECO b-
utton.
Pleaseremove ba-
Tteriesto avoid le-
akagedamage w-
Hennot using for
Along time.
Note
Child-lock:Press and
together to active.
Display ON/OFF:
Long press ECObutton.
Please remove batteries
to avoid leakagedamage
when not usingfor a long
time.
Signal
receptor
When you insert the batteries for the first time in the remote
controller or if you change them, you can program the remote
controller of only cooling or cooling and heating.
1. Long press MODE button over 5s to get into the change mode
within 3minutes;
2. Press MODE button to change COOL or HEAT.
NOTE: If you adjust the remote controller in cooling mode,
it will not be possible to activate the heating function in units with
heating pump . you need to take out the batteries and repeat the
procedure described above.
When you insert the batteries for the first time in the remote
controller or if you change them, you can program the temperature
OO
display switchover function between C and F.
1. Long press TURBO button over 5s to get into the change mode
within 3minutes;
OO
2. Press TURBO button to change C and F.

11
flaps
flap
movement Deflectors
“SWING”CONTROL OF THE AIR FLOW
The deflectors are positioned manually and placed un-
der the flaps .They allow to direct the air flow rightw-
ard or leftward.
Flaps manually, the delicate mech-
anism might seriously damaged!
Never poke fingers, sticks or other objects in the air
inlet or outlet vents. Such accidental contact with live
pants might cause unforeseeable damage or hurt.
This adjustment must be done while the appliance
is switched off.
1.Press the button to activate the FLAP ,
(1) If press time interval is in 2 seconds, the swing will cycle as
below:
(2) If long press the button,the swing angle range of horizontal
flap will cycle as below:
(3) If press time interval is over 2 seconds, it will be deactivate
the air flow is directed alternatively from up to down .In
order to guarantee an even diffusion of the air in the room.
2.Press the button to activates the motorized deflectors ,
(1) If press time interval is in 2 seconds, the swing will cycle as
below:
(2) If long press the button,the swing will cycle as below:
(3) If press time interval is over 2 seconds, it will be deactivate
the air flow is directed alternatively from left to right.
(Optional function, depends on the models)
OPERATING INSTRUCTIONS
Filter
Heat
Fan
Exchanger
The direction of the air outlet is motorized up and down
by flaps, and manually moved right and left by the vertical
deflectors, for some models, the vertical deflectors could be
controlled by motor as well.
The air sucked by the fan enters from the grill and
passes through the filter, then it is cooled/dehumidified
or heated through the heat exchanger.
deactivate
deactivate

12
OPERATING INSTRUCTIONS
COOLING MODE
The cooling function allows the air condit-
ioner to cool the room and at the same time
reduces Air humidity.
COOL
To activate the cooling function ( COOL ) , press the
MODE button until the symbol COOL
appears on the display.
HEATING MODE (Optional)
The cooling function is activated by setting the button
or at a temperature lower than that of the room.
To optimize the function of the Air conditioner, adjust
the temperature (1) , the speed (2) and the direction
of the air flow (3) by pressing the button indicated.
HEAT
The heating function allows the air conditi-
oner to heat the room.
To activate the heating function ( HEAT ) , press the
MODE button until the symbol HEAT
appears on the display.
With the button or set a temperature higher than
that of the room..
To optimize the function of the Air conditioner adjust
the temperature ( 1 ), the speed ( 2 ) and the direction
of the air flow ( 3 ) by pressing the button indicated
In HEATING operation, the appliance can automatically
activate a defrost cycle, which is essential to clean the
frost on the condenser so as to recover its heat exchange
function.This procedure usually lasts for 2-10 minutes
during defrosting,indoor unit fan stop operation.
After defrosting ,it resumes to HEATING mode
automatically.
OPERATING INSTRUCTIONS
This function reduces the humidity of the
air to make the room more comfortable.
To set the DRY mode , Press MODE until
DRY appears in the display . An automatic
function of alternating cooling cycles and air
fan is activated.
DRY
DRY MODE

13
OPERATING INSTRUCTIONS
FAN
The air conditioner works in only
ventilation.
To set the FAN mode , Press MODE until
FAN appears on the display.
FAN MODE(Not FAN button)
To optimize the function of the air conditioner, adjust
the temperature(1), the speed (2) and the direction of the
air flow (3) by pressing the buttons indicated.
AUTO MODE
Automatic mode.
To activate the AUTO mode of operation,
press the MODE button on the remote controller until
the symbol AUTO appears on the display.
In AUTO mode the run mode will be set automatically
according to the room temperature.
To optimize the function of the air conditioner, adjust
the temperature(1), the speed (2) and the direction of the
air flow (3) by pressing the buttons indicated.
AUTO
DISPLAY
DISPLAY function (Indoor display)
Switch on/off the LED display on panel
SLEEP
SLEEP function
Press OPTION at the fist time , select the DISPLAY by
pressing the button or until symbol DISPLAY is flashing;
Press OPTION again to switch off the LED display on the
panel, and appears on the remote controller display.
Do it again to switch on the LED display.
DISPLAY
After 10 hours running in sleep mode the air conditioner
is swicthed off automatically.
Press OPTION at the first time , select the SLEEP by
pressing the button or until symbol SLEEP is flashing;
Press OPTION again to activate the SLEEP function,
and appears on the display.
Do it again to deactivate this function.
SLEEP

14
OPERATING INSTRUCTIONS
The air conditioner works in GEN mode
To activate GEN function,pressing the button GEN and
the unit current level will cycle as below
OFF L3 L2 L1
To cancel this function,press the GEN until code OFF
appers on the display.
Turbo function
To activate turbo function,pressing the button TURBO
or pressing the button FAN until symbol appears
on the display.
In AUTO/HEAT/COOL/FANmode,
When you selectTURBO feature, it will use
the highest fansetting to blowstrong airflow.
To cancel this function, pressing the FAN to switch
other fan speed or pressing the TURBO button again.
Through GEN mode,you can choose the current level of
the unit.There are three levels (L1,L2,L3) in this mode,
and the current increases in turn.
(Optional)
ECO
In this mode the appliance automatically sets the operation to
achieve energy savings.
1. Press the "ON / OFF" button to turn on appliance and select
a COOLING / HEATING mode.
2. Press the "ECO" button, the appliance will run in ECO mode.
3. Pressing the "ECO" button again will cancel the mode, "ECO"
will no longer be shown on the LCD screen.
NOTE:
The ECO function is available in COOLING and HEATING modes.
ECO function

15
OPERATING INSTRUCTIONS
TIMER
TIMER function
To set the automatic switch-on /off
of the air conditioner
Note:
All processing should be operated in 5 seconds,
otherwise the processing will be cancelled.
1. Press OPTION at the first time , select the Timer by
pressing the button or until symbol TIMER
is flashing;
TIMER
SLEEP TIMER I FEEL
DISPLAY 8 CH
HEAT
SLEEP TIMER I FEEL
DISPLAY 8 CH
TIMER
CLEAN DISPLAY
HEAT
TIMER
CLEAN DISPLAY
Timer setting/change/cancel:
3. To set the timer or change the timer:
(1)Press the button or to set the expected timer
(Increase or decrease at half-hour intervals)
the symbols hand TIMER both are flashing.
(2) Press OPTION or waiting for 5 seconds without any
operation to confirm the timer , the pre-setting
timer like and symbol will be on the display.
4. To cancel the timer(if TIMER is on)
Repeat step 1, step 2, then press OPTION or waiting for 5
seconds without any operation to cancel the timer .
A sample for the Timer-on as Figure1, Timer-off as Figure2
Figure1,Timer-on
when switch off
Figure2,Timer-off
when switch on
I FEEL function (Optional)
I FEEL
Press OPTION at the first time , select the I FEEL by
pressing the button or until symbol I FEEL
is flashing; Press OPTION again to activate the
I FEEL function, and appears on the display.
Do it again to deactivate this function.
I FEEL
This function enablethe remote controlto measure
the temperature atits current locationand send this
signal 7 timesin 2 hoursto the airconditioner to
enable the airconditioner to optimizethe temperature
around you andensure maximum comfort.
It will automaticallydeactivate 2 hourslater.
2. Press OPTION again, the data symbol like
and TIMER willbe flashing;

1. This function help carry away the accumulated
dirt, bacteria, etc from the evaporator.
2. This function will run about 30 minutes, and it will return to the
pre-setting mode .You can press to cancel this function during
the process. You will hear 2 beeps when it's finished or cancelled.
3. It's normal if there are some noise during this function process,
as plastic materials expand with heat and contract with cold.
4. We suggest operate this function as the following ambient
condition to avoid certain safety protection features.
5. We suggest operate this function per 3 months.
OPERATING INSTRUCTIONS
SELF-CLEAN function (Optional)
Indoor unit
Outdoor unit
Temp<30
5 <Temp<30
16
MILDEW function (Optional)
MILDEW
Press OPTION at the first time , select the MILDEW by
pressing the button or until symbol MILDEW
is flashing; Press OPTION again to activate the
MILDEW function, and appears on the display.
Do it again to deactivate this function.
MILDEW
This function enablethe air conditionerstill blow
airflow about 15minutes to drythe indoor innerparts
to avoid mildew, when theair conditioner isoff.
Note: MILDEW functiononly available inDRY/COOLING mode
Press OPTION at the first time , select the CLEAN by pressing the
button or until symbol CLEAN is flashing; Press OPTION again
to activate the CLEAN function, and appears on the display.
Do it again to deactivate this function.
CLEAN
CLEAN
8heating function (Optional)
8 H
1.Press OPTION at the first time , select the 8 H by
pressing the button or until symbol 8 H
is flashing; Press OPTION again to choose the
8 heating function, and appears on the display.
Do it again or change the mode to deactivate this function.
2.If the airconditioner is standby, this functionenable the
air conditioner automaticallystart heating whenthe
indoor temperature isequal or lowerthan 8 , it will return
standby if thetemperature is equalor higher than18 .
8 H
It can beset in Cool/Heat/Dry/Fan/Automode,
but you needto turn off the unit toactivate it.
Switch off the air conditionerby pressing

17
The air conditioner is programmed for comfortable and suitable living conditions as below
if used outside the conditions, certain safety protection features might come into effect.,
Table of contents
Popular Air Conditioner manuals by other brands

Daikin
Daikin R-410A Technical manual

Retro Aire
Retro Aire R30C Installation, operation & maintenance manual

GE
GE AEC14 Owner's manual and installation instructions

Mitsubishi Electric
Mitsubishi Electric MSZ-GE25VA operating instructions

Frigidaire
Frigidaire FFRE0533S1E0 Use & care guide

Mitsubishi Electric
Mitsubishi Electric PUZ-ZM200YKA2-ET Service manual