Mottura 99.746 Quick start guide

12 V
RELAY MODULE - Battery or mains power version
99.746
INSTALLATION/USE INSTRUCTIONS
All connections MUST
be made with the electri-
cal supply switched o
and the batteries discon-
nected.
GENERAL WARNINGS
This manual is intended for technically qualied and trained installers.
Mottura Serrature di Sicurezza S.p.A. thanks you for choosing this product and reminds you:
- Read the instructions very carefully before installing or doing any maintenance on the device.
- All assembly and connection procedures must be done according to Rules of Good Engineering as well as in conformity to law.
- DO NOT install this device in explosive environments or atmospheres or in the presence of ammable fumes/gases.
- DO NOT install this device on a door with risk of contact with water or atmospheric agents unless the door is adequately protected.
- Always disconnect the power supply and isolate all live parts before installing or doing any maintenance on the device. Take all possible precautions
to eliminate the risk of electrical shock when doing the installation and/or maintenance procedures described in this manual.
- The installer must give these instructions and all maintenance instructions to the user.
- Keep these instructions for future use and attach the sales receipt to validate the warranty.
- In case of problems, contact your authorized dealer only.
Mottura Serrature di Sicurezza S.p.A. may change the characteristics of the products described in these instructions at any time and without notice.
WARRANTY TERMS
This device has been inspected by Mottura Serrature di Sicurezza S.p.A. and is guaranteed against all manufacturing defects for the period
dened by Italian law; the period begins on the date of purchase as demonstrated by the sales receipt. The warranty is eective if the sales
receipt, bearing information identifying the device, is shown to the dealer or service personnel. The warranty covers the replacement or repair of
parts found defective due to faulty manufacture; shipping costs to and from service centers are charged to the customer.
In case of a repeated malfunction of the same origin or a malfunction that cannot be repaired, Mottura Serrature di Sicurezza S.p.A. may decide,
in its nal judgment, to replace the entire device. The warranty on the replacement device will continue to the expiration of the original device.
If the device must be serviced at the customer’s home, the customer is required to pay (if requested) a minimum charge to cover the transfer
costs of authorized service personnel.
Transport is at the customer’s risk if the customer ships the device, and at the service personnel’s risk if the device is picked up and transported
by service personnel.
LIMITS OF LIABILITY
The warranty does not cover damage deriving from:
- negligence, carelessness, or use other than as described below
- failure to protect the device before doing any procedure that may generate scrap or waste (welding, drilling of panels, drilling of structure, etc.) that prevents
its correct functioning
- maintenance work not conforming to these instructions or done by unauthorized personnel
- use of accessories/components that are not original Mottura products
- shipping of the device without the necessary precautions
- any circumstances not attributable to manufacturing defects.
Operating temperature: -10°C to +55°C. In addition, Mottura Serrature di Sicurezza S.p.A. declines all liability for any harm to persons or damage to property
deriving from failure to comply with all of the instructions and warnings contained in this manual.

2
99.729
99.730
99.686
99.736
99.748
99.776
99.749
99.775
99.699
(+)
(
-
)
12 V
1 - INTRODUCTION
Relay MODULE (99.746) to start up to an actuator previously stored access credentials. Access credentials can
be a numeric code, a TAG RFID, or a ngerprint that can be inserted by means of a dedicated external device
connected to the control unit. Relay module permits the use of a Mottura electronic device (ngerprint reader
art. 99.729/730/748/776 or numeric keypad art. 99.686/736/749/775) on any electric, electronic or motorized
locks, via cable art. 99.699 (not included).
The system can operate with a keypad, with a TAG RFID reader or with a ngerprint, for security reasons it is
mandatory to store at least one master TAG to enable relay operation. The consensus given by the relay lasts
for 1 second. Battery power or main power 12Vdc with mains adaptor cod. 99.683 or similar.
ATTENTION: before powering and using this product, it is mandatory to read these notes, the instructions for use and any other
document supplied, both in paper and electronic format, including by means of links of any kind. This product is intended for the
exclusive use for which it was designed, built and sold; any other use other than that indicated as "compliant use" is not compliant
and therefore not admissible. The intended use for this product is:
INTERFACE WITH RELAY FOR ELECTRONIC LOCK OPENING
Any other use not expressly provided for or described here and in the ocial documentation is to be con-
sidered non-compliant and potentially dangerous for people, animals, things and the environment.
The user assumes all risks in case of use that does not comply with the description contained herein.
Mottura S.p.A. is in no way responsible for any non-compliant and unforeseen uses for this product, which may cause problems or
damage of any kind to people, animals, things and the environment.

3
10 sec.
R1
VAL
(+)
(
-
)
12 V
2 - SET-UP BUTTON FUNCTIONS
Relay MODULE is factory set up end does not require any changes. The fol-
lowing steps should only be performed only if needed to change the original
setting. For example : replacing the keypad escutcheon with other device.
WARNING : Replacing the keypad escutcheon does not require authentication be-
cause the codes are stored in the control unit.
The set-up button allows following functions:
- ngerprint authentication
- reset of the control unit.
2.1 FINGERPRINT ESCUTCHEON AUTHENTICATION
Fingerprint escutcheon must be authenticated with the control unit. For this operation, refer to the specic
instructions.
2.2 COMPLETE RESET OF THE CONTROL UNIT
Attention : This operation dele-
tes all TAGs, pin codes (keypad
escutcheon) or authentication
ngerprint escutcheon
NOTE: it does not erase the
ngerprints stored in it), and
enables the service TAGs.
CONNECTION WITH MOTORIZED LOCKING
3 - ELECTRICAL WIRING
BATTERY HOLDER
POWER SUPPLY
MOTORIZED LOCKING
With a clean contact control input
6÷9.6 Vdc
9÷12 Vdc
OR
230 Vac
CONNECTOR
SECTIONABLE
Press SET-UP button for 10 seconds Exit

4
4 - TECHNICAL DATA
We recommend using the MOTTURA battery holder cod. 99 703/704 or the mains adaptor cod. 99.683. The contact
of the relay provides a xed-duration impulse of 1 sec. See the wiring diagram supplied before connecting the
devices.
INPUT POWER
SUPPLY
VOLTAGE / FREQUENCY 6 ÷ 12 VDC
MAX POWER 2 W
MAX ELECTRICAL ABSORBITION 200 mA
WORKING TEMPERATURE Min -10 °C ÷ Max.+55 °C
MECHANICAL WEIGHT < 0,1 Kg
DIMENSIONS 55 x 33 x 21 mm
RELAY OUTPUTS VOLTAGE MAX 60 VDC - 500 mA
ATTENTION: the relay output can switch loads with a maximum absorption of 500 mA;
in the presence of higher absorption it is mandatory to interpose a power relay between
the interface and the lock, whose excitation coil does not absorb more than 500 mA.
Failure to comply with this indication can irreversibly damage the interface, with immediate
forfeiture of any form of guarantee.

5
1 2 3
4 4 4
13
2 4
5 5 5
Press P Present
MASTER TAG (1)
Present
TAG (2)
Memorization
MASTER TAG
TAG already
memorized
as MASTER
TAG already
memorized
as SERVICE
WARNING : If there are no stored TAGs in the control unit (brand new or after a reset), any free TAG
Mottura allows you to programming enter! It is therefore necessary immediately to store their own
MASTER TAGs, then the service ones, if provided, to ensure maximum security. After this operation
only memorized TAGs will be accepted by the control unit.
5 - KEYPAD PROGRAMMING - TAG MANAGEMENT
5.1 MEMORIZING MASTER TAG KEYS
(1) If the lock is new or
reset, any free Mottura
TAG can be used to enter
programming mode!
(2) Becomes MASTER TAG
To exit, press "E" or wait 30 sec. (timeout).
To exit, press "E" or wait 30 sec. (timeout).
5.2 MEMORIZING SERVICE TAG KEYS
WARNING : if no TAGS are memorized on the control unit (brand new or after a reset), any free Mot-
tura TAG can be used to enter programming mode! You should immediately memorize rst your
MASTER TAGs, then any service TAGs, to guarantee maximum security.
Press P Present
MASTER TAG
Present
TAG
Memorization
SERVICE TAG
TAG already
memorized
as MASTER
TAG already
memorized
as SERVICE
ONLY for escutcheons 99775/99776 before each operation,
press any key to activate the escutcheon

6
13 4
( )
X4
2 5
666
13 4 5
2
6
7
8
1 3 4 5 6
2
5.3 DELETING INDIVIDUAL TAG
WARNING
: You CANNOT delete the master TAG used to enter programming mode.
TAG
deleted Unknown TAG
ERROR !
MASTER
TAG
Press P Present
MASTER TAG
Present
TAG
To exit, press "E" or wait 30 sec. (timeout).
To exit, press "E" or wait 30 sec. (timeout).
5.4 DELETING ALL TAG KEYS
Press P Present
MASTER TAG
Type
1-2-3
and press E
TAGS being
deleted
5.5 DISABLING/ENABLING SERVICE TAG KEYS
To exit press P or E
Press P Present
MASTER TAG
To enable,
type
1-2-3
and press E
To disable, type 3-2-1
and press E
7-ENABLE
7-DISABILITY
SERVICE TAGS, if inserted,
are disabled
SERVICE TAGS, if inserted,
are disabled

7
1 3
24
5 5
5
1 3 4
2
6 6
Enter the code
and press E
6 - KEYPAD PROGRAMMING - CODE MANAGEMENT
6.1 MEMORIZING PERSONAL ACCESS CODES
CODE
stored
CODE
already
memorized
Press P Present
MASTER TAG
To exit, press "E" or wait 30 sec. (timeout).
To exit, press "E" or wait 30 sec. (timeout).
WARNING
:
Enter a code
composed of a
minimum of 3
to a maximum
of 8 digits
Enter the code
and press E
CODE
deleted
ERROR !
Unknown CODE
6.2 DELETING A PERSONAL ACCESS CODE
Press P Present
MASTER TAG
ONLY for escutcheons 99775/99776 before each operation,
press any key to activate the escutcheon

www.mottura.it
6
1 3 4
25
7
99336GB-REV.05-12/21 - a_025227
Pursuant to article 26 of Italian Legislative Decree no. 49 of 14 March 2014 “Implementation of EU Directive 2012/19 concerning
waste electrical and electronic equipment (WEEE)” and article 9 of Italian Legislative Decree no. 188 of 20 November 2008 “Imple-
mentation of EC Directive 2006/66 on batteries and accumulators and waste batteries and accumulators” adequate waste sorting for
subsequent sending of disposed equipment to recycling, treatment and environmentally compatible disposal contributes to avoiding
possible negative eects on the environment and human health and promotes reuse and/or recycling of the materials composing
the equipment. Unlawful disposal of the product by the user may result in the application of penalties pursuant to current laws and
regulations on the matter. We remind that batteries and power adapters, if present, must be removed before the device is disposed.
Batteries and adapters must be collected and separately disposed.
To exit, press "E" or wait 30 sec.
(timeout).
Type
9-8-7
and press E
Press P Present
MASTER TAG
6.3 DELETING ALL PERSONAL ACCESS
Deleting CODES in
progress
WARNING : If you push the "P" button, you will get the output from the programming.
Table of contents
Popular Control Unit manuals by other brands

Paradox
Paradox DGP-LSN4 V1.1 Programming guide

Astral Pool
Astral Pool CONTROL BASIC installation manual

Data Video
Data Video RMC-190 quick start guide

Redline
Redline RDL-3000 Series product manual

Flow Safe
Flow Safe F8000 Series Installation operation & maintenance

KEBCO
KEBCO COMBIVERT G6 Programming manual

M-TI
M-TI M200-RS Hardware user's guide

Control Technologies
Control Technologies CTI 2554-A Installation and operation guide

IOLINK
IOLINK S4A Series user guide

AutomationDirect
AutomationDirect CLICK C0-08SIM manual

flakt woods
flakt woods STRA-07 R Installation and maintenance manual

UseTECH
UseTECH FlowTimer+ Protect Set operating manual