manuals.online logo
Brands
  1. Home
  2. •
  3. Brands
  4. •
  5. Moxa Technologies
  6. •
  7. Cell Phone
  8. •
  9. Moxa Technologies UC-7408-CE User manual

Moxa Technologies UC-7408-CE User manual

Other Moxa Technologies Cell Phone manuals

Moxa Technologies nport 5400 series User manual

Moxa Technologies

Moxa Technologies nport 5400 series User manual

Moxa Technologies NPort Express DE-211 User manual

Moxa Technologies

Moxa Technologies NPort Express DE-211 User manual

Moxa Technologies nport 5400 series User manual

Moxa Technologies

Moxa Technologies nport 5400 series User manual

Popular Cell Phone manuals by other brands

Nokia 6700 classic user guide

Nokia

Nokia 6700 classic user guide

LG L34C user guide

LG

LG L34C user guide

Ericsson T60d manual

Ericsson

Ericsson T60d manual

Zte Score M user manual

Zte

Zte Score M user manual

Sony Xperia Z1 Compact Startup guide

Sony

Sony Xperia Z1 Compact Startup guide

AT AT-Q5 user manual

AT

AT AT-Q5 user manual

Vingtor ACM-M-A-V2 Installation/configuration

Vingtor

Vingtor ACM-M-A-V2 Installation/configuration

Olitech EasyFlip 2 Quick setup guide

Olitech

Olitech EasyFlip 2 Quick setup guide

Zte Atrium Z793C user manual

Zte

Zte Atrium Z793C user manual

Alcatel IDEAL manual

Alcatel

Alcatel IDEAL manual

Zte BLADE A520 quick start guide

Zte

Zte BLADE A520 quick start guide

switel M222 user manual

switel

switel M222 user manual

LG LG-P503 user guide

LG

LG LG-P503 user guide

LG F2410 user guide

LG

LG F2410 user guide

Argom E500 manual

Argom

Argom E500 manual

Hisense U30 user manual

Hisense

Hisense U30 user manual

Argom Tech E401 user manual

Argom Tech

Argom Tech E401 user manual

Nokia 3595 - Cell Phone - GSM Manual Del Usuario

Nokia

Nokia 3595 - Cell Phone - GSM Manual Del Usuario

manuals.online logo
manuals.online logoBrands
  • About & Mission
  • Contact us
  • Privacy Policy
  • Terms and Conditions

Copyright 2025 Manuals.Online. All Rights Reserved.

— 1 — — 2 — — 3 —
UC-7408-CE
Quick Installation Guide
Second Edition, June 2008
1. Overview
MOXA UC-7408 features eight RS-232/422/485 serial ports, an 8-ch
digital input, an 8-ch digital output, dual 10/100 Mbps Ethernet ports,
PCMCIA, and a CompactFlash interface for wireless LAN
communication and flash disk expansion, making UC-7408 ideal for
embedded applications.
2. Package Checklist
Before installing UC-7408, verify that the package contains the
following items:
y1 UC-7408
yWall-Mounting Kit
yDIN-Rail Mounting Kit
yUC-7408 Quick Installation Guide (this guide)
yUC-7408 Documentation & Software CD
yCross-over Ethernet cable
yCBL-RJ45M9-150: 150 cm, 8-pin RJ45 to Male DB9 serial port cable
yCBL-RJ45F9-150: 150 cm, 8-pin RJ45 to Female DB9 console port
cable
yUniversal Power Adaptor
yProduct Warranty Statement
Please notify your sales representative if any of the above items are
missing or damaged.
3. UC-7408 Panel Layout
NOTE: UC-7420 (shown in the figures) has a CF slot, PCMCIA slot,
and two USB 2.0 Host ports (circled below). UC-7410 does NOT have
these three features.
Rear View
DC 12-48V LAN1 LAN2 Console
V+ V-
PCMCIA
CF
12-48 VDC
Power Input
CF x 1
PCMCIA x 1
10/100 Mbps Ethernet x 2
USB 1.1 Client x 1,
miniB Connector
RS-232
PPP/Console
Top View
Front View
Reset
P1
RS-232/422/485
P2 P3 P4 P5 P6 P7 P8
Reset to
Default
D/O D/I
RJ45 RS-232/422/485
Connectors x 8
1 2 3 5 64 7 8 1 2 3 5 64 7 8
Reset to Default
8-ch Digital Output 8-ch Digital Input
Hardware Reset
4. Installing UC-7408
Wall or Cabinet
The two metal brackets included with UC-7408 can be used to attach it
to a wall, or the inside of a cabinet. Using two screws per bracket, first
attach the brackets to the bottom of the UC-7408. Next, use two screws
per bracket to attach the UC-7408 to a wall or cabinet.
DIN-Rail Mounting
The aluminum DIN-Rail attachment plate is included in the package.
To attach the plate to UC-7408, situate the stiff metal spring towards
the top.
STEP 1: Insert the top of the
DIN-rail into the slot just below the
stiff metal spring.
STEP 2: The DIN-Rail attachment
unit will snap into place as shown
below.
metal
spring
DIN-Rail
metal
spring
DIN-Rail
To remove UC-7408 from the DIN-Rail, simply reverse Steps 1 and 2
above.
5. Connector Description
Power Connector
Connect the 12-48 VDC power line to UC-7408’s terminal block. If the
power is properly supplied, the Ready LED will will show a solid green
color when the OS is ready.
Grounding UC-7408
Grounding and wire routing help limit the effects of noise due to
electromagnetic interference (EMI). Run the ground connection from the
ground screw to the grounding surface prior to connecting the power.
ATTENTION
This product is intended to be mounted to a well-grounded mounting
surface such as a metal panel.
SG
SG: The Shielded Ground (sometimes called Protected
Ground) contact is the left most contact of the
3-pin power terminal block connector when
viewed from the angle shown here. Connect the
SG wire to an appropriate grounded metal surface.
Ethernet Ports
The 10/100 Mbps Ethernet ports (LAN 1 and LAN 2) use RJ45
connectors.
Pin Signal
1 ETx+
2 ETx-
3 ERx+
6 ERx-
81
Serial Ports
The eight serial ports (P1 to P8) use RJ45 connectors. Each port can be
configured by software for RS-232, RS-422, or RS-485. The pin
assignments are shown in the following table:
Pin RS-232 RS-422 RS-485
1 DSR --- ---
2 RTS TXD+ ---
3 GND GND GND
4 TXD TXD- ---
5 RXD RXD+ Data+
6 DCD RXD- Data-
7 CTS --- ---
8 DTR --- ---
81
D/I, D/O
The eight Digital Input channels and
eight Digital Output channels use
separate terminal blocks.
1 2 3 5 64 7 8
PCMCIA
The PCMCIA slot supports the CardBus (Card-32) Card standard and
16-bit (PCMCIA2.1/JEIDA 4.2) Card standard. It supports +3.3V, +5V,
and +12V at a working voltage of 120 mA.
CompactFlash
UC-7408 provides one CompactFlash slot that supports CompactFlash
type I/II card expansion. Currently, MOXA provides a CompactFlash
disk for plug & play expansion. You may also use flash disks available
from most computer supply outlets. The CompactFlash will be
mounted at
\> CFFolder
P/N: 1802074081011
— 4 — — 5 — — 6 —
Console Port
The console port is an RJ45 RS-232 port. It is designed for serial
console, and can be connected to a V90 or GPRS modem via PPP. The
pin definitions are the same as for the eight serial ports (P1 to P8).
Reset to Default Button
Press the “Reset to Default” button continuously for at least 5 seconds
to load the factory default configuration. After the factory default
configuration has been loaded, the system will reboot automatically.
The Ready LED will blink on and off for the first 5 seconds, and then
maintain a steady glow once the system has rebooted.
Reset Button
Press the “Reset” button to activate the hardware reset function. You
should only use this function if the software does not function properly.
To reset a system, you should reboot the operating system to avoid
deleting important data.
USB
The USB 1.1 Client port is reserved for future enhancement.
Real Time Clock
UC-7408’s real time clock is powered by a lithium battery. We strongly
recommend that you do not replace the lithium battery without help
from a qualified MOXA support engineer. If you need to change the
battery, contact the Moxa RMA service team.
ATTENTION
There is a risk of explosion if the battery is replaced by an incorrect type.
6. Powering on UC-7408
To power on UC-7408, connect the “terminal block to power jack
converter” to the UC-7408’s DC terminal block (located on the left
back panel), and then connect the power adaptor. Note that the Shielded
Ground wire should be connected to the right most pin of the terminal
block. It takes about 30 seconds for the system to boot up. Once the
system is ready, the Ready LED will light up, and UC-7408’s network
settings will appear on the LCM display.
7. Connecting UC-7408 to a PC
There are two ways to connect UC-7408 to a PC, through the serial
console port or by Telnet over the network. The COM settings for the
serial console port are: Baudrate = 115200 bps, Parity = None, Data
bits = 8, Stop bits = 1, Flow Control = None.
ATTENTION
Remember to choose the “VT100” terminal type. Use the
CBL-RJ45F9-150 cable included with the product to connect a PC to
UC-7408’s serial console.
To use Telnet you will need to know UC-7408’s IP address and
netmask. The default LAN settings are shown below. For first-time
configuration, you may find it convenient to use a cross-over Ethernet
cable to connect the PC directly to the UC-7408.
Default IPAddress Netmask
LAN 1 192.168.3.127 255.255.255.0
LAN 2 192.168.4.127 255.255.255.0
Once the UC-7408 is powered on, the Ready LED will light up, and a
login page will open. Use the following default Login name and
Password to proceed.
Login: admin
Password: admin
8. Configuring the Network Setting
Normally, you are required to change the IP address of UC-7400-CE
because it is located in a different local network from that of your
development workstation. Use the netconfig utility to complete the task.
Before using this utility, type netconfig -h to examine the usage of the
command.
\> netconfig –h
Usage: netconfig –n <“LAN1” or “LAN2”> [-m <netmask>] [-d
<DNS server>] [-g <gateway>] [-i <IP address>]
For example, your development workstation has a LAN port at
192.168.1.x and the Domain Name Server (DNS) is at 192.168.2.6.
Execute the following command.
\> netconfig –n LAN1 –i 192.168.1.5 –m 255.255.255.0 –g
192.168.1.254 –d 192.168.2.6
Type netconfig to view the new settings.
\> netconfig
LAN1 Interface Configuration:
IP Address: 192.168.1.5
SubNet Mask: 255.255.255.0
Gateway: 192.168.1.254
DNS: 192.168.2.6
LAN2 Interface Configuration:
IP Address: 192.168.4.127
SubNet Mask: 255.255.255.0
Gateway:
DNS:
9. Developing YourApplication
Application development on the UC-7400-CE computer takes
advantage of a number of well-known tools that are provided by the
Windows environment in programmers’ workstations. These tools are
trouble-free to use for Windows programmers. Check the following
development tools for Windows Embedded Application Development.
yVB.NET/C# Applications: Use Visual Studio 2005
yVB.NET/C# Applications: Use Visual Studio .NET 2003
yC/C++ Applications: Use eMbedded Visual C++ (eVC) 4.0
Visual Studio 2005
You do not need to install additional packages.
Visual Studio .NET 2003
1. Install Visual Studio .NET 2003
2. Install Windows® CE Utilities for Visual Studio .NET 2003Add-on
Pack (550KB) for VB .NET
3. Import Compact .NET Framework SDK
eMbedded Visual C++ (eVC) 4.0
1. Install eMbedded Visual C++ 4.0 (230 MB)
2. Install Service Pack 4 for eVC 4.0 (68 MB)
3. Install MOXAWindows® CE 5.0 C/C++ SDKs
Developing applications with eVC 4.0 and MOXA SDKs
1. Open Microsoft® eMbedded Visual C++ 4.0.
2. From the File menu, choose New.
3. Choose the Projects tab and then select the type of application.
4. In the Project name box, type project name, then click OK.
5. Choose the application type you want to create and click Finish.
6. On the Build toolbar, choose the MOXA UC-7400-CE SDK, the
type of run-time image (Release or Debug), and the UC-7400-CE
device.
7. Write your application code.
8. From the Build menu, choose Rebuild All to build the application.
9. When you complete your application, use the web-based
management system to upload it to the target computer.
Developing a VB.NET / C# application with .NET Compact
Framework
1. Open Microsoft® Visual Studio .NET 2003.
2. From the File menu, choose New ÆProject.
3. Choose the Project Type and then select the Smart Device
Application type of application.
4. In the Project name box, type a name for the project, and then click
OK.
5. Choose the Windows CE target platform.
6. Select the project type and click OK.
7. Write your application code.
8. From the Device toolbar, choose Windows CE.NET Device.
9. From the Build menu, choose Build Project or Rebuild Project.
10.When you complete your application, use the web-based
management system to upload it to the target computer.
Click here for online support:
www.moxa.com/support
The Americas: +1-714-528-6777 (toll-free: 1-888-669-2872)
Europe: +49-89-3 70 03 99-0
Asia-Pacific: +886-2-8919-1230
China: +86-21-5258-9955 (toll-free: 800-820-5036)
©2008 Moxa Inc., all rights reserved.