MPL mSERLED User manual

µSERLED User Manual
The µSERLED is a LED Panel used on various MPL network products. It converts the serial stream into signals
to control 6 dual color LEDs. Additional 2 Buttons are implemented which may be used as Reset and Default
Button.
This Manual is written for Users of an MPL Network Device as Open Frame, whereas the µSERLED is
optional.
●Features:
●Deserialization of 6 Dual color LEDs.
●Up to 8 different mappings selectable with DIP
switch
●Two push-Buttons
●Small footprint (24 x 56 x 8.6mm)
●7 Pin Connector.
2022 by MPL AG MEH- 0203-00 Rev. C
High-Tech • Made in Switzerland
µSERLED
User Manual

TABLE OF CONTENTS
1 INTRODUCTION............................................................................................................ 5
1.1 ABOUT THIS MANUAL........................................................................................................5
1.2 SAFET PRECAUTIONS AND HANDLING.........................................................................5
1.3 ELECTROSTATIC DISCHARGE (ESD) PROTECTION.......................................................5
1.4 EQUIPMENT SAFET .......................................................................................................... 5
1.5 MANUAL REVISIONS........................................................................................................... 6
.5. RELATED PRODUCTS.................................................................................................6
.5.2 REVISION HISTORY....................................................................................................6
1.6 RELATED DOCUMENTATION.............................................................................................7
1.7 STANDARDS COMPLIANCE...............................................................................................8
.7. EMC.............................................................................................................................. 8
.7.2 ENVIRONMENTAL........................................................................................................ 8
.7.3 SAFETY.........................................................................................................................8
.7.4 TYPE APPROVAL......................................................................................................... 8
1.8 ORDERING INFORMATION................................................................................................. 9
2 DIMENSIONS...............................................................................................................10
2.1 Top View............................................................................................................................. 10
2.2 Side view............................................................................................................................ 10
3 PARTS LOCATION......................................................................................................11
4 CONFIGURATIONS.....................................................................................................11
4.1 µMAGBES........................................................................................................................... 11
4. . µMAGBES-A 0OH / µMAGBES-A 0OR ( 0 Port Open Frame µMAGBES)...............
4. .2 µMAGBES-x 9OH / µMAGBES-x 9OR ( 9 Port Open Frame µMAGBES)................ 2
4. .2. Master µMAGBES-x 9OH................................................................................................... 2
4. .2.2 Slave µMAGBES-x 9OH..................................................................................................... 2
4. .3 µMAGBES-x8OH......................................................................................................... 2
4. .4 µMAGBES-x 4OH....................................................................................................... 3
4. .4. Master µMAGBES-x 4OH................................................................................................... 3
4. .4.2 Slave µMAGBES-x 4OH..................................................................................................... 3
4.2 µGUARD............................................................................................................................. 14
4.2. µGUARD-A3OH / µGUARD-A3OR (3 Port Open Frame µGUARD)............................ 4
4.2.2 µGUARD-A 2OH / µGUARD-A 2OR ( 2 Port Open Frame µGUARD)...................... 4
4.2.2. Master µGUARD.................................................................................................................. 4
4.2.2.2 Slave µMAGBES.................................................................................................................. 4
4.3 µMAXBES........................................................................................................................... 15
4.3. µMAXBES-A 0OH ( 0 Port Open Frame µMAXBES)................................................. 5
5 CONNECTORS............................................................................................................16
5.1 J1 Factory use only........................................................................................................... 16
5.2 J7 LED Panel Connector................................................................................................... 16
6 COP RIGHT................................................................................................................20
7 DISCLAIMER...............................................................................................................20
8 TRADEMARKS............................................................................................................20
9 SUPPORT....................................................................................................................20
2022 by MPL AG 2 MEH- 0203-00 Rev. C
High-Tech • Made in Switzerland
µSERLED
User Manual

TABLE OF FIGURES
Figure : µSERLED Top view Dimensions.......................................................................................................... 0
Figure 2: µSERLED Side view Dimensions......................................................................................................... 0
Figure 3: µSERLED Parts Location.....................................................................................................................
2022 by MPL AG 4 MEH- 0203-00 Rev. C
High-Tech • Made in Switzerland
µSERLED
User Manual

1 INTRODUCTION
1.1 ABOUT THIS MANUAL
This manual, and the MPL Network Product (i.e. µMAGBES, µGUARD) User Manual provides all the
information necessary to handle and configure the µSERLED.
The manual is written for technical personnel responsible for integrating the µSERLED into their systems.
It is strongly recommended to read the MPL Network Product (i.e. µMAGBES, µGUARD) User
Manual and also this manual before the µSERLED is switched on.
1.2 SAFET PRECAUTIONS AND HANDLING
For personal safety and safe operation of the µSERLED, follow all safety procedures described here and in
other sections of the miscellaneous manual.
●Remove power from the system before installing (or removing) the µSERLED, to prevent the possibility of
personal injury (electrical shock) and / or damage to the product.
●Handle the product carefully; i.e. dropping or mishandling the µSERLED can cause damage to assemblies
and components.
●Do not expose the equipment to moisture.
WARNING
There are no user-serviceable components on the µSERLED.
1.3 ELECTROSTATIC DISCHARGE (ESD) PROTECTION
Various electrical components within the product are sensitive to static and electrostatic discharge (ESD). Even
a small static discharge can be sufficient to destroy or degrade a component's operation!
With an open housing, do not touch any electronic components. Handle or touch only the unit chassis.
1.4 EQUIPMENT SAFET
Great care is taken by MPL AG that all its products are thoroughly and rigorously tested before leaving the
factory to ensure that they are fully operational and conform to specification. However, no matter how reliable a
product, there is always the remote possibility that a defect may occur. The occurrence of a defect on this
device may, under certain conditions, cause a defect to occur in adjoining and/or connected equipment. It is
your responsibility to protect such equipment when installing this device. MPL accepts no responsibility
whatsoever for such defects, however caused.
2022 by MPL AG 5 MEH- 0203-00 Rev. C
High-Tech • Made in Switzerland
µSERLED
User Manual

1.5 MANUAL REVISIONS
1.5.1 RELATED PRODUCTS
Manual
Revisions
Related To
A•µSERLED- Rev. A & Rev. B
B•µSERLED- Rev. C or Rev.B with TU MEW- 0226-00 -A
C•µSERLED- Rev. D or any Revision with TU MEW- 0226-002-A
1.5.2 REVISION HISTOR
Manual
Revisions
Date Description
A 202 -08-25 Initial release of this document. Moved from µMAGBES & µGUARD Manual
B 2022-04- 3 Added configuration for µMAGBES-A8OH
C 2022- 0-24 Added configuration for µMAGBES-A 4OH (master & slave)
2022 by MPL AG 6 MEH- 0203-00 Rev. C
High-Tech • Made in Switzerland
µSERLED
User Manual

1.6 RELATED DOCUMENTATION
The following documents are related to this manual. For detailed Information about a specific xxx feature or
setting please refer to this additional manuals.
Reference Description Available from
[ ] µMAGBES User Manual MPL AG: www.mpl.ch
[2] µGUARD User Manual MPL AG: www.mpl.ch
[3] µMAXBES User Manual MPL AG: www.mpl.ch
2022 by MPL AG 7 MEH- 0203-00 Rev. C
High-Tech • Made in Switzerland
µSERLED
User Manual

1.7 STANDARDS COMPLIANCE
The µSERLED is designed to meet or exceed the most common industry and military standards. Particular
references are:
1.7.1 EMC
•EN 55022 Class B (Information technology equipment - Radio disturbance characteristics - Limits and
methods of measurement)
•EN 55024 (Information technology equipment - Immunity characteristics - Limits and methods of
measurement)
•EN 6 000-4- (Electromagnetic compatibility (EMC) -- Part 4- : Testing and measurement techniques -
Overview of IEC 6 000-4 series)
•EN 6 000-4-2 Level 3, Criterion B (Electromagnetic compatibility (EMC) -- Part 4-2: Testing and
measurement techniques - Electrostatic discharge immunity test)
•EN 6 000-4-3 Level 3, Criterion A (Electromagnetic compatibility (EMC) -- Part 4-3: Testing and
measurement techniques - Radiated, radio-frequency, electromagnetic field immunity
test)
•EN 6 000-4-4 Class 3 (Electromagnetic compatibility (EMC) -- Part 4-4: Testing and measurement
techniques - Electrical fast transient/burst immunity test)
•EN 6 000-4-5 Class 3 (Electromagnetic compatibility (EMC) -- Part 4-5: Testing and measurement
techniques - Surge immunity test)
•EN 6 000-4-6 Class 3 (Electromagnetic compatibility (EMC) -- Part 4-6: Testing and measurement
techniques - Immunity to conducted disturbances, induced by radio-frequency fields)
•EN 6 000-6- (Electromagnetic compatibility (EMC) -- Part 6- : Generic standards - Immunity for
residential, commercial and light-industrial environments)
•EN 6 000-6-2 (Electromagnetic compatibility (EMC) -- Part 6-2: Generic standards - Immunity for industrial
environments)
•EN 6 000-6-3 (Electromagnetic compatibility (EMC) -- Part 6-3: Generic standards - Emission standard for
residential, commercial and light-industrial environments)
•EN 6 000-6-4 (Electromagnetic compatibility (EMC) -- Part 6-4: Generic standards - Emission standard for
industrial environments)
•MIL-STD-46 E (REQUIREMENTS FOR THE CONTROL OF ELECTROMAGNETIC INTERFERENCE
CHARACTERISTICS OF SUBSYSTEMS AND EQUIPMENT)
1.7.2 ENVIRONMENTAL
•EN 50 55 (Railway applications - Electronic equipment used on rolling stock)
•MIL-STD-8 0-F (ENVIRONMENTAL ENGINEERING CONSIDERATIONS AND LABORATORY TESTS)
1.7.3 SAFET
•EN 6060 - (Medical electrical equipment -- Part : General requirements for safety)
•EN 62368 (Audio/video, information and communication technology equipment)
1.7.4 T PE APPROVAL
•EN 60945 Protected Equipment (Maritime navigation and radiocommunication equipment and systems -
General requirements - Methods of testing and required test results)
•E 0 (Test Specification for Type Approval)
2022 by MPL AG 8 MEH- 0203-00 Rev. C
High-Tech • Made in Switzerland
µSERLED
User Manual

1.8 ORDERING INFORMATION
The table below gives you an overview of the different xxx variants and its features.
Product Name Product Features
µSERLED- •µSERLED with 6 dual Color LEDs and 2 Push Button. Without Lightpipes
•
2022 by MPL AG 9 MEH- 0203-00 Rev. C
High-Tech • Made in Switzerland
µSERLED
User Manual

2 Dimensions
2.1 Top View
2.2 Side view
Recommended Panel Holes for Switches Ø 2.6mm for LEDs Ø 3. mm
2022 by MPL AG 0 MEH- 0203-00 Rev. C
High-Tech • Made in Switzerland
µSERLED
User Manual
O
N
2
O
N
2
56.0
24.0
3.5
0
6.5
9.0
4.0
6.5
9.0
2 .5
24.0
26.5
29.0
3 .5
34.0
36.5
39.0
4 .5
44.0
46.5
49.0
5 .5
52.5
7.5
Ø2.7
6.0
2 .0
Figure 1: µSERLED Top view Dimensions
.6
3.5
7.0
2.7
6.4
Lightpipe, only one of
6 pcs shown
Ø2.5 Ø3.0
Figure 2: µSERLED Side view Dimensions

3 Parts Location
The LED mapping on the µSERLED is configurable via the two DIP Switches S3 and S4. Lightpipes are only
installed on the used LEDs and needs to be ordered separately. The LEDs are a copy from the on-board LEDs.
Additionally LEDs are:
•Power: Green if Power is applied (PWR).
•Reset: Red is Reset is asserted (RST).
•Status: Not yet defined (ST).
Other additionally LEDs may described in the respective Product User Manual.
4 Configurations
4.1 µMAGBES
4.1.1 µMAGBES-A10OH / µMAGBES-A10OR (10 Port Open Frame µMAGBES)
Configuration Switches:
S4- S4-2 S3- S3-2
off off off ON
Buttons:
S : Reset
S2: Default
LED Mapping:
D D2 D3 D4 D5 D6 D7 D8 D9 D 0 D D 2 D 3 D 4 D 5 D 6
PWR RST ST P0 P P2 P3 P4 P5 P6 P7 P8 P9
LED with empty fields are not used (no Lightpipe installed)
2022 by MPL AG MEH- 0203-00 Rev. C
High-Tech • Made in Switzerland
µSERLED
User Manual
Figure 3: µSERLED Parts Location
D 5
O
N
2
O
N
2
S
S2
S4
S3
J7 J
D D2 D 6

4.1.2 µMAGBES-x19OH / µMAGBES-x19OR (19 Port Open Frame µMAGBES)
4.1.2.1 Master µMAGBES-x19OH
Configuration Switches:
S4- S4-2 S3- S3-2
off off ON off
Buttons:
S : Reset
S2: Default
LED Mapping:
D D2 D3 D4 D5 D6 D7 D8 D9 D 0 D D 2 D 3 D 4 D 5 D 6
PWR RST ST P0 P P2 P3 P4 P5 P6 P7 P8
LED with empty fields are not used (no Lightpipe installed)
4.1.2.2 Slave µMAGBES-x19OH
Configuration Switches:
S4- S4-2 S3- S3-2
off off ON ON
Buttons:
S : Not used
S2: Not used
LED Mapping:
D D2 D3 D4 D5 D6 D7 D8 D9 D 0 D D 2 D 3 D 4 D 5 D 6
P9 P 0 P P 2 P 3 P 4 P 5 P 6 P 7 P 8
LED with empty fields are not used (no Lightpipe installed)
4.1.3 µMAGBES-x8OH
Configuration Switches:
S4- S4-2 S3- S3-2
ON off off off
Buttons:
S : Reset
S2: Default
LED Mapping:
D D2 D3 D4 D5 D6 D7 D8 D9 D 0 D D 2 D 3 D 4 D 5 D 6
PWR RST ST P0 P P2 P3 P4 P5 P6 P7
LED with empty fields are not used (no Lightpipe installed)
2022 by MPL AG 2 MEH- 0203-00 Rev. C
High-Tech • Made in Switzerland
µSERLED
User Manual

4.1.4 µMAGBES-x14OH
4.1.4.1 Master µMAGBES-x14OH
Configuration Switches:
S4- S4-2 S3- S3-2
ON off off ON
Buttons:
S : Reset
S2: Default
LED Mapping:
D D2 D3 D4 D5 D6 D7 D8 D9 D 0 D D 2 D 3 D 4 D 5 D 6
PWR RST ST P0 P P2 P3 P4 P5 P6
LED with empty fields are not used (no Lightpipe installed)
4.1.4.2 Slave µMAGBES-x14OH
Configuration Switches:
S4- S4-2 S3- S3-2
ON off ON off
Buttons:
S : Not used
S2: Not used
LED Mapping:
D D2 D3 D4 D5 D6 D7 D8 D9 D 0 D D 2 D 3 D 4 D 5 D 6
P7 P8 P9 P 0 P P 2 P 3
LED with empty fields are not used (no Lightpipe installed)
2022 by MPL AG 3 MEH- 0203-00 Rev. C
High-Tech • Made in Switzerland
µSERLED
User Manual

4.2 µGUARD
On µGUARD the status LED (ST) is the copy of the on-board Status LED.
4.2.1 µGUARD-A3OH / µGUARD-A3OR (3 Port Open Frame µGUARD)
Configuration Switches:
S4- S4-2 S3- S3-2
off ON ON off
Buttons:
S : Reset
S2: Not used
LED Mapping:
D D2 D3 D4 D5 D6 D7 D8 D9 D 0 D D 2 D 3 D 4 D 5 D 6
PWR RST ST ETH ETH0 ETH2 PCI0 PCI M.2
LED with empty fields are not used (no Lightpipe installed)
4.2.2 µGUARD-A12OH / µGUARD-A12OR (12 Port Open Frame µGUARD)
4.2.2.1 Master µGUARD
Configuration Switches:
S4- S4-2 S3- S3-2
off ON off off
Buttons:
S : Reset
S2: Not used
LED Mapping:
D D2 D3 D4 D5 D6 D7 D8 D9 D 0 D D 2 D 3 D 4 D 5 D 6
PWR RST ST ETH2 ETH0 PCI0 PCI M.2
LED with empty fields are not used (no Lightpipe installed)
4.2.2.2 Slave µMAGBES
Configuration Switches:
S4- S4-2 S3- S3-2
off off ON ON
Buttons:
S : Not used
S2: Not used
LED Mapping:
D D2 D3 D4 D5 D6 D7 D8 D9 D 0 D D 2 D 3 D 4 D 5 D 6
P0 P P2 P3 P4 P5 P6 P7 P8 P9
LED with empty fields are not used (no Lightpipe installed)
2022 by MPL AG 4 MEH- 0203-00 Rev. C
High-Tech • Made in Switzerland
µSERLED
User Manual

4.3 µMAXBES
4.3.1 µMAXBES-A10OH (10 Port Open Frame µMAXBES)
Configuration Switches:
S4-1 S4-2 S3-1 S3-2
off off off off
Buttons:
S : Reset
S2: Default
LED Mapping:
D D2 D3 D4 D5 D6 D7 D8 D9 D 0 D D 2 D 3 D 4 D 5 D 6
PWR RST ST P0 P P2 P3 P4 P5 P6 P7 P8 P9
LED with empty fields are not used (no Lightpipe installed)
2022 by MPL AG 5 MEH- 0203-00 Rev. C
High-Tech • Made in Switzerland
µSERLED
User Manual

5 Connectors
5.1 J1 Factory use only.
Do not connect anything to this connector.
5.2 J7 LED Panel Connector
Connect this to the external LED Panel Connector of the MPL Network Product.
The Connector J7 is a 7 pin mm shrouded with positive lock.
Pin no. Signal Description MOLEX 501331-0707
DFLTBTNn Default Button
2 RSTBTNn Reset Button
3 DATA Serial Data
4 GATE Gate
5 CLOCK Clock
6 +3.3V +3.3V System Voltage
7 GND Ground
2022 by MPL AG 6 MEH- 0203-00 Rev. C
High-Tech • Made in Switzerland
µSERLED
User Manual
7

This page intentionally left blank.
2022 by MPL AG 7 MEH- 0203-00 Rev. C
High-Tech • Made in Switzerland
µSERLED
User Manual

This page intentionally left blank.
2022 by MPL AG 8 MEH- 0203-00 Rev. C
High-Tech • Made in Switzerland
µSERLED
User Manual

This page intentionally left blank.
2022 by MPL AG 9 MEH- 0203-00 Rev. C
High-Tech • Made in Switzerland
µSERLED
User Manual

6 COP RIGHT
Copyright © 2022 by MPL AG Elektronikunternehmen. All rights are reserved. Reproduction of this document in
part or whole, by any means is prohibited, without written permission from MPL AG Elektronikunternehmen.
7 DISCLAIMER
MPL AG has fully tested the µSERLED and reviewed the documentation. However, MPL AG makes no warranty
or representation, either expressed, or implied, with respect to this product, its quality, performance,
merchantability, or fitness for a particular purpose.
In no event will MPL AG be liable for direct, indirect, special, incidental, or consequential damages resulting
from any defect in the product or its documentation, even if advised of the possibility of such damages. In
particular MPL AG shall have no liability for any parts connected to this product.
MPL AG reserves the right to make changes to any product herein to improve reliability, function or design.
8 TRADEMARKS
Brand or product names are trademarks and registered trademarks of their respective holders.
9 SUPPORT
9.1 CONTACT MPL AG
In case of general information questions please feel free to contact us at our homepage ( www.mpl.ch) or per
email ([email protected]).
In case of sales information questions please send an email to [email protected].
If you have a technical problem with a µSERLED, first please this manual carefully. If you can’t solve the
problem on your own you can contact us for technical support per email at [email protected].
Our local Distributor:
2022 by MPL AG 20 MEH- 0203-00 Rev. C
High-Tech • Made in Switzerland
µSERLED
User Manual
Table of contents
Other MPL Network Hardware manuals
Popular Network Hardware manuals by other brands

Paradyne
Paradyne Jetstream CPX-1000 reference guide

Costar Video Systems
Costar Video Systems Central Point CR08CI00 quick guide

ADC
ADC HiGain H2TU-C-319 List 4E Quick installation

Grandstream Networks
Grandstream Networks GRP262 Series Administration guide

JETWAY
JETWAY FDF13 Series Quick installation manual

Silvertel
Silvertel Ag102 user manual