manuals.online logo
Brands
  1. Home
  2. •
  3. Brands
  4. •
  5. MrCool
  6. •
  7. Air Conditioner
  8. •
  9. MrCool Advantage Series User manual

MrCool Advantage Series User manual

Other manuals for Advantage Series

8

Other MrCool Air Conditioner manuals

MrCool Signature MCVP Series User manual

MrCool

MrCool Signature MCVP Series User manual

MrCool Olympus Hyper Heat Series User manual

MrCool

MrCool Olympus Hyper Heat Series User manual

MrCool DIY Series User manual

MrCool

MrCool DIY Series User manual

MrCool Olympus Series User manual

MrCool

MrCool Olympus Series User manual

MrCool Signature Series User manual

MrCool

MrCool Signature Series User manual

MrCool DIY Series User manual

MrCool

MrCool DIY Series User manual

MrCool DIY Series User manual

MrCool

MrCool DIY Series User manual

MrCool Oasis Series User manual

MrCool

MrCool Oasis Series User manual

MrCool DIY E Star Series User manual

MrCool

MrCool DIY E Star Series User manual

MrCool PTAC 5 Series Operating instructions

MrCool

MrCool PTAC 5 Series Operating instructions

MrCool Advantage Series User manual

MrCool

MrCool Advantage Series User manual

MrCool DIY E Star Series Quick start guide

MrCool

MrCool DIY E Star Series Quick start guide

MrCool Advantage Series User manual

MrCool

MrCool Advantage Series User manual

MrCool Advantage Series User manual

MrCool

MrCool Advantage Series User manual

MrCool DIY E Star Series Operating instructions

MrCool

MrCool DIY E Star Series Operating instructions

MrCool Advantage Series User manual

MrCool

MrCool Advantage Series User manual

MrCool DIY Series User manual

MrCool

MrCool DIY Series User manual

MrCool DIYCASSETTE HP-230C25 Series Operating instructions

MrCool

MrCool DIYCASSETTE HP-230C25 Series Operating instructions

MrCool Advantage Series User manual

MrCool

MrCool Advantage Series User manual

MrCool Advantage Series User manual

MrCool

MrCool Advantage Series User manual

MrCool MAC17 A Series User manual

MrCool

MrCool MAC17 A Series User manual

MrCool MWUC 5 Series Operating instructions

MrCool

MrCool MWUC 5 Series Operating instructions

MrCool Signature MAC16 A Series User manual

MrCool

MrCool Signature MAC16 A Series User manual

MrCool Signature Series Quick start guide

MrCool

MrCool Signature Series Quick start guide

Popular Air Conditioner manuals by other brands

Fujitsu ASYG 09 LLCA installation manual

Fujitsu

Fujitsu ASYG 09 LLCA installation manual

York HVHC 07-12DS Installation & owner's manual

York

York HVHC 07-12DS Installation & owner's manual

Carrier Fan Coil 42B Installation, operation and maintenance manual

Carrier

Carrier Fan Coil 42B Installation, operation and maintenance manual

intensity IDUFCI60KC-3 installation manual

intensity

intensity IDUFCI60KC-3 installation manual

Frigidaire FAC064K7A2 Factory parts catalog

Frigidaire

Frigidaire FAC064K7A2 Factory parts catalog

Sanyo KS2432 instruction manual

Sanyo

Sanyo KS2432 instruction manual

LG MultiV Series installation manual

LG

LG MultiV Series installation manual

CLIMAVENETA a-CHD U-2T 606+2209 OPERATING AND INSTALLATION Manual

CLIMAVENETA

CLIMAVENETA a-CHD U-2T 606+2209 OPERATING AND INSTALLATION Manual

Midea EWK06CW5 user manual

Midea

Midea EWK06CW5 user manual

Pioneer FAB Series installation manual

Pioneer

Pioneer FAB Series installation manual

SPT WA-1511S user manual

SPT

SPT WA-1511S user manual

Mitsubishi Electric Mr.Slim MSZ-A24NA operating instructions

Mitsubishi Electric

Mitsubishi Electric Mr.Slim MSZ-A24NA operating instructions

Mitsubishi Electric PUHZ-RP50VHA4 Service manual

Mitsubishi Electric

Mitsubishi Electric PUHZ-RP50VHA4 Service manual

Panasonic CS-S18HKQ Service manual

Panasonic

Panasonic CS-S18HKQ Service manual

Panasonic CS-E15NKE3 operating instructions

Panasonic

Panasonic CS-E15NKE3 operating instructions

Gree GWH18TC-K3DNA1B/I Service manual

Gree

Gree GWH18TC-K3DNA1B/I Service manual

Friedrich ZoneAire Compact P08SA owner's manual

Friedrich

Friedrich ZoneAire Compact P08SA owner's manual

Daikin R32 Split Series installation manual

Daikin

Daikin R32 Split Series installation manual

manuals.online logo
manuals.online logoBrands
  • About & Mission
  • Contact us
  • Privacy Policy
  • Terms and Conditions

Copyright 2025 Manuals.Online. All Rights Reserved.

Please keep this manual where the operator can easily find it.
Inside you will find helpful hints on how to use and maintain your
unit properly. Just a little preventative care on your part can save
you a great deal of time and money over the life of your unit.
You’ll find answers to many common problems within this manual.
Advantage Series
User Manual
Please read this manual carefully before installation and keep it for future reference.
For more information visit www.mrcool.com.
1
When using this air conditioner in the European countries, please read the following
information:
•This appliance can be used by children aged from 8 years and above and persons with
reduced physical, sensory or mental capabilities, or lack of experience and knowledge if
they have been given supervision or instruction concerning use of the appliance in a safe
way and understand the hazards involved. Children shall not play with the appliance.
Cleaning and user maintenance shall not be made by children without supervision.
DISPOSAL: Do not dispose of this product as unsorted municipal waste. Collection of such
waste separately for special treatment is necessary.
It is prohibited to dispose of this appliance in domestic household waste. For disposal,
there are several possibilities:
A) The municipality has established collection systems, where electronic waste can be
disposed of at least free of charge to the user.
B) When buying a new product, the retailer will take back the old product at least free of
charge.
C) The manufacturer will take back the old appliance for disposal at least free of charge to
the user.
D) As old products contain valuable resources, they can be sold to scrap metal dealers.
Wild disposal of waste in forests and landscapes endangers your health when hazardous
substances leak into the ground-water and find their way into the food chain.
NOTICE
For more information visit www.mrcool.com.
2
WARNING This symbol indicates the possibility of death or serious injury.
CAUTION This symbol indicates the possibility of injury or damage to property.
To prevent injury to the user or other people and property damage, the following instructions must be
followed. Incorrect operation due to ignoring of instructions may cause harm or damage. The seriousness
is classified by the following indications.
•Meanings of the symbols used in this manual are as shown below
Strictly prohibited.
Be sure to follow the instructions.
WARNING
•Do not extend the cable and never use multiple
plugs. A poor electrical connection, poor insulation
or voltage which is higher than permitted can
cause fire.
•Do not expose your body directly to the cool air for
prolonged period.
•Never poke fingers, sticks or other objects in the air
inlet and outlet vents.
•Never attempt to repair, relocate, modify the air
conditioner yourself. Always contact your service
partner if it requires.
•Never pull the plug out by pulling on the cable. Hold
the plug firmly and pull it out of the plug socket,
otherwise there is a risk of damaging the cable.
•Do not operate your air conditioner in a wet room
such as a bathroom or laundry room.
•Remove all dirt from the power plug and plug it
firmly. Soiled plugs can cause fire or an electric
shock.
•In the event of any abnormalities such as smell of
burning, immediately switch off the device and pull
the plug. Contact your service partner.
•Always switch off the device and pull the plug before
you start to clean it.
•Use specified power cord.
•Contact the authorized installer for installation of
this unit.
•Contact an authorized service technician for repair
or maintenance of this unit.
•This appliance is not intended for use by persons
(including children) with reduced physical, sensory
or mental capabilities, or lack of experience and
knowledge, unless they have been given supervision
or instruction concerning use of the appliance by a
person responsible for their safety.
•Children should be supervised to ensure that they
do not play with the air conditioner.
SAFETY PRECAUTIONS
For more information visit www.mrcool.com.
3
CAUTION
•If the air conditioner is to be used in conjunction
with other heaters, the air should be refreshed
periodically, otherwise there is a risk of lack of
oxygen.
•Always pull out the power plug if the unit is not
going to be used for any lengthy period of time.
Collections of dust can cause fire.
•Always switch off the air conditioner and pull out
the power plug during a storm. Electrical parts may
get damaged.
•Check that the drainage line is correctly connected.
If not, water will escape.
•Check that the condensation water can run off
unhindered. It may cause water damage if the
condensation water cannot run off properly.
•The air conditoner must be earthed in accordance
with the local codes.
•For electrical safety purposes we recommend that
you install an earthleakage circuit-breaker.
•If the power cord is damaged, it must be replaced
by the manufacturer, its service agent or similary
qualified persons in order to avoid a hazard.
•Never actuate any switches with a wet hand. It may
cause an electric shock.
•Never use the device for any other purpose than the
intended use.
•Never place food, precision instruments, plants,
animals, paint, etc. on the unit.
•Do not expose plants or animals directly to the air
flow.
•Never clean the air conditioner with water.
•Never use combustible cleaning agents as these
could cause a fire or deformation.
•Never place any burning objects close to the device
if they could be directly affected by the emitted air.
•Never step onto the outdoor device and never place
anything on it.
•Never use an unsteady or rusty base.
•Never install the air conditioner in places where
combustible gas can be emitted. Emmitted gas may
collect and cause an explosion.
•Never allow the air conditioner to run for too long
with the doors or windows open, or if the humidity
is very high.
SAFETY PRECAUTIONS
For more information visit www.mrcool.com.
4
Airinlet(
rear)
Airinlet
(side)
Airoutlet
4
3
5
2
6
1
9
10
8
7
Signal receiver
A
B
Signal receiver
Indoor unit
1. Front panel
2. Air inlet
3. Air filter
4. Air outlet
5. Horizontal air flow grill
6. Vertical air flow louver(inside)
7. Display panel
Outdoor unit
8. Connecting pipe
9. Connecting cable
10. Stop valve
NOTE: All the pictures in this manual are for explanation
purposes only. The actual shape of the indoor unit you
purchased may be slight different on front panel and
display window.The actual shape shall prevail.
Indication lamp
OPERATION indication lamp
This lamp illuminates when the air conditioner
is in operation.
TIMER indication lamp
Lights up during Timer operation.
DEFROST indication lamp
(Enabled on cooling & heating models only):
Lights up when the air conditioner starts
defrosting automatically or when the warm
air control feature is activated in heating
operation.
Temperature indicator
•Displays the temperature settings when the
air conditioner is operational.
•Displays the malfunction code.
NAMES OF PARTS
For more information visit www.mrcool.com.
5
Special functions
Refrigerant Leakage Detection
With this new technology, the dipsplay area will appear EC and the indication lamps continue flashing
when the outdoor unit detects refrigerant leakage.
Louver Angle Memory Function (optional)
Within the scope of safety angle, it will memorize the open angle of horizontal louver. If it exceeds, it will
memorize the boundry of safety angle. In the following circumstances, it will return to standard angle:
1) pressing the manual control button, 2) unplug and then plug in the machine. So we strongly suggest that
the open angle of the horizontal louver should not be set too small, in case the condensed water forms
and drops from the horizontal louver.
SELF CLEAN function (optional)
•Function used after the Shut Down of cooling operation to clean the Evaporator and keep it as fresh for
the next operation.
•The unit will operate as following sequence : FAN ONLY mode at Low fan speed, Heating operation with
LOW fan speed(applicable to cooling & heating modles only), FAN ONLY operation, Stop Operation, Turn
off.
Note:
•This function is only available under COOL(AUTO COOL, FORCED COOL) and DRY mode.
•Before select the function, it is recommended to run the air conditioner under Cooling operation for about half
an hour. Once the Self Clean function is activated, all TIMER setting will be cancelled.
•During Self Clean operation, when press the SELF CLEAN button on the remote controller again will stop the
operation and turn off the unit automatically.
CLEAN AIR function (on some models)
Improving the quality of indoor air is one of the purposes of an air conditioner. This air conditioner is
equipped with ionizer or Plasma Dust Collector(Depending on specific configuration of the model). With
the anions generated by Ionizer, the air circulation of the air conditioner fills the room with refreshing,
natural and healthy air. The Plasma Dust Collector generates a high voltage ionization zone, through which
the air is converted to plasma. Inside the air most of the dust, smoke, and pollen particles are captured by
the electrostatic filter.
Anti-mildew function (optional)
When turns off the unit on COOL, DRY, AUTO (Cool) mode, the air conditioner will continue operating for
about 7-10 minutes (depending on models) at LOW fan speed. If turns off on HEAT mode, the unit will
continue operating for about 30 seconds at LOW fan speed. This will help to dry up the condensed water
inside the evaporator, and prevent the breeding of mildew. Under Anti-mildew operation, do not restart
the air conditioner until the unit is completely off.
NOTE: This manual does not include Remote Controller Operations, see the Remote Controller Manual packed
with the unit for details.
OPERATING INSTRUCTIONS
For more information visit www.mrcool.com.
6
Manual switch
Manual switch
AUTO/COOL
Suspension bars
AUTO/COOL
1
2
Mode
Temperature
Room temperature
Outdoor
temperature
NOTE:
1. Optimum performance will be achieved within these operating temperatures. If air
conditioner is used outside of the above conditions, certain safety protection features might
come into operation and cause the unit to function abnormally.
2. If the air conditioner runs for a long time in cooling mode and the humidity is high(over 80%),
condensed water may drip out of the unit. Please sets the vertical air flow louver to its
maximum angle (vertically to the floor), and set HIGH fan mode.
Suggestion: For the unit adopts an Electric Heater, when the outside ambient temperature is
below 32°F(0°C), we strongly recommend you to keep the machine plugged in order to
guarantee it running smoothly.
Cooling operationHeating operationDrying operation
62°F~90°F
(17°C~32°C)
32°F~122°F
(0°C~50°C)
(5°F~122°F / -15°C~50°C
For the models with low
temperature cooling system)
32°F~86°F
(0°C~30°C)
5°F~86°F
(-15°C~30°C)
50°F~90°F
(10°C~32°C)
32°F~122°F
(0°C~50°C)
Operating temperature
Manual operation
Units are equipped with a switch to run emergency operation mode. It can be accessed by opening the
front panel. This switch is used for manual operation in case the remote controller fails to work or
maintenance necessary.
NOTE: The unit must be turned off before operating the manual
control button. If the unit is operational, continue pressing the
manual control button until the unit is off.
1. Open and lift the front panel up to an angle until it remains
fixed with a clicking sound. For some models, please use suspension
bars to prop up the panel.
2. One press of the manual control switch will lead to the forced
AUTO operation. If press the switch twice within five seconds, the
unit will operate under forced COOL operation.
3. Close the panel firmly to its original position.
CAUTION
•This switch is used for testing purposes only. You had better
not choose it.
•To restore the remote controller operation, use the remote
controller directly.
OPERATING INSTRUCTIONS
For more information visit www.mrcool.com.
7
Range
Range
Deector rod
Airflow direction control
Adjust the air flow direction properly, otherwise it
might cause discomfort or cause uneven room
temperatures.
Adjust the horizontal louver using the remote controller.
Adjust the vertical louver manually.
To set the vertical air flow (Up - Down) direction
Perform this function while the unit is in operation.
Use the remote controller to adjust the air flow
direction. The horizontal louver can be moved at
a range of 6O for each press, or swing up and down
automatically. Please refer to the REMOTE CONTROL
MANUAL for details.
To set the horizontal air flow direction (Left - Right)
•Move the deflector rod manually to adjust the air flow
in the direction you prefer.
IMPORTANT: Do not put your fingers into the panel of
blower and suction side. The high-speed fan inside may
cause danger.
CAUTION
•Do not operate the air conditioner for long periods with
the air flow direction set downward in cooling or
dehumidifying mode. Otherwise, condensation may
occur on the surface of the horizontal louver causing
moisture to drop on to the floor or on furnishings.
•When the air conditioner is started immediately after it
was stopped, the horizontal louver might not move for
approximately 10 seconds.
•Open angle of the horizontal louver should not be set
too small, as COOLING or HEATING performance may
be impaired due to too restricted air flow area.
•Do not move the horizontal louver manually, otherwise
the horizontal louver will be out of sync. Please cease
operating, unplug power for a few seconds, then restart
the air conditioner.
OPERATING INSTRUCTIONS
For more information visit www.mrcool.com.
8
1 hour
1 hour
Set
Temperature
Set
Temperature
Cooling
Heating
SLEEP operation
1 hour1 hour
SLEEP operation
7 hours timer o
7 hours timer o
How the air conditioner works
AUTO operation
•When you set the air conditioner in AUTO mode, it will
automatically select cooling, heating(cooling/heating
models only), or fan only operation depending on set
temperature and the room temperature.
•The air conditioner will control room temperature
automatically to the temperature point you set.
•If you feel uncomfortable in the AUTO mode, you can set
your desired temperature.
SLEEP operation
When you push SLEEP button on remote controller
during cooling, heating(cooling & heating models only),
or AUTO operation , the air conditioner will
automatically increase (cooling) or decrease (heating)
2°F / 1°C per hour for the first 2 hours, then hold
steadily for the next 5 hours, after that it will switch off.
This mode saves you energy and brings you comfort
at night.
DRYING operation
•The fan speed will be automatically controlled under dry operation.
•During the dry operation, if the room temperature is lower than 50°F (10°C), the compressor stops
operation and restarts until the room temperature is above 54°F (12°C).
Optimal operation
To achieve optimal performance, please note the following:
•Adjust the air flow direction correctly so that it is not forwards people.
•Adjust the temperature to achieve the highest comfort level. Do not adjust the unit to excessive
temperature levels.
•Close doors and windows on COOL or HEAT modes, or performance may be reduced.
•Use TIMER ON button on the remote controller to select a time you want to start your air conditioner.
•Do not put any object near air inlet or air outlet, as the efficiency of the air conditioner may be reduced
and the air conditioner may stop running.
•Clean the air filter periodically, otherwise cooling or heating performance may be reduced.
•Do not operate unit with horizontal louvre in closed position.
OPERATING INSTRUCTIONS
For more information visit www.mrcool.com.
9
Filter Handle
Air freshening lter
Before mainatenance
•Turn the system off before cleaning. To clean, wipe with
a soft, dry cloth. Do not use bleach or abrasives.
NOTE: Power supply must be disconnectd before cleaning the
indoor unit.
CAUTION
•A cloth dampened with cold water may be used
on the indoor unit if it is very dirty. Then wipe it
with a dry cloth.
•Do not use a chemically treated cloth or duster to
clean the unit.
•Do not use benzine, thinner, polishing powder, or
similar solvents for cleaning. These may cause
the plastic surface to crack or deform.
•Never use water hotter than 40 C/104 F to clean
the front panel, it could cause deformation of
discoloration.
Cleaning the unit
Wipe the unit with a soft dry cloth only. If the unit is
very dirty, wipe it with a cloth soaked in warm water.
Cleaning the air filter and air freshening filter
A clogged air filter reduces the cooling efficiency of
this unit. Please clean the filter once every 2 weeks.
1. Lift the indoor unit panel up to an angle until it
stops with a clicking sound.For some models,
please use suspension bars to prop up the panel.
2. Take hold of the handle of the air filter and lift it
up slightly to take it out from the filter holder,
then pull it downwards.
3. Remove the AIR FILTER from the indoor unit.
Clean the AIR FILTER once two weeks.
Clean the AIR FILTER with a vacuum cleaner
or water, then dry it up in cool place.
4. Remove the Air Freshening Filter from its supporting
frame (on some models).
•Clean the air freshening filter at least once a
month, and replace it every 4-5 months.
•Clean it with vacuum cleaner, then dry it in cool
place.
CARE & MAINTENANCE
For more information visit www.mrcool.com.