MSS Professional SmokeCloak VALI Series User guide

VALI Range Manual
INSTALLATION AND OPERATING INSTRUCTION

2 VALI Range user manual
Every effort has been made to ensure that the contents of this
manual are correct. MSS Professional A/S does not accept any
liability for loss or damage caused or alleged to be caused directly or
indirectly by this manual. The contents of the manual may be subject
to change without notice. MSS Professional A/S makes no warranty
of any kind with regards to this material.
© 2009 MSS Professional
Reproduction in any matter whatsoever without the written permission
of MSS Professional A/S is strictly forbidden.
READ AND SAVE THESE
INSTRUCTIONS
MSS Professional A/S
Agerhatten 25
DK - 5220 Odense SØ
Danmark
Telefon: +45 7217 0011
www.smokecloak.com

3
VALI Range user manual
Manual
VALI Range
Please read this manual carefully before attempting to install an VALI.

4 VALI Range user manual
Conventions
The following symbols are used in this manual to help you install the
SmokeCloak system correctly and safely.
Note
Gives useful advice or suggestions to enhance the
performance of the SmokeCloak system.
Important
Indicates important information that is critical for
the correct use of your products and must always be
read carefully.
It is essential that only genuine SmokeCloak uid is
used. Damage to the equipment and possible health
hazard is likely if incorrect uid is used. The warranty
on all of the equipment will also be void.
Under no circumstances should the on board power
supplies of the SmokeCloak (terminals 1, 6, 19, and
20) be linked to any other 3rd party equipment e.g.
alarm panels, additional power supplies, etc. as this
could cause unexpected faults within the machines

5
Contents
Contents
PRODUCT OVERVIEW........ 6
1. IN THE BOX ...................... 7
2. QUICK START GUIDE.......... 8
3. SPECIFICATIONS ............ 10
4. MACHINE LAYOUT.......... 12
5. INSTALLATION ................ 13
Requirements........................ 13
Torque setting ....................... 14
Horizontal Installation............. 14
Mounting the machine............ 15
Wall Installation..................... 16
6. CHANGING THE NOZZLE.. 17
7. INSTALLING THE NOZZLE
FOR THE FIRST TIME....... 18
8. FLUID ............................. 19
Installing the Fluid Bottle ........ 19
9. PRIMING THE MACHINE.. 22
10. BATTERIES ..................... 23
Installing the Batteries............ 23
11. WIRING UP THE MACHINE 27
Wiring the mains feed ............ 27
Wiring the batteries................ 27
12. INTERFACE BOARD ......... 28
Layout.................................. 28
13. CONNECTION DETAILS .... 29
Status LEDS ......................... 29
Interface board Connections .... 30
Outputs ................................ 42
Test button wiring .................. 44
14. CLOAKSENSOR ............... 46
Installation............................ 46
Locations to avoid .................. 47
15. SETTING THE TIMER........ 48
16. PREPARATION FOR
FINAL TEST..................... 50
17. MAINTENANCE .............. 51
18. PC-Tool ........................... 52
Updating the registry.............. 52
Installing the VALI drivers ....... 53
Conguration software............ 54
19. USING THE SOFTWARE ... 55
Connecting to the VALI ........... 55
20. ACCESSORIES................. 62
Fluid FL600-V....................... 62
Cloaksensor CS07A ............... 63
Strobe IPL3000 .................... 64
Sounder IPA 117 ................... 65
Voice Module ........................ 66
Batteries............................... 67

6 VALI Range user manual
Product Overview
Strong Background
The VALI range is build on more than 20 years of experience in the fog
security industry.
Powerful
The addition of the V10 and V20 to the SmokeCloak range offers a new
level of raw power in terms of the amount of output these units are able
to produce. Whilst also being the slimmest and sleekest machines to be
produced to date, this makes them perfect for any application, be that an
ofce requiring a professional yet discreet look, or a retail outlet requiring
lightning quick response time and maximum protection.
Simplicity
From the new ‘engineer friendly’ mounting system to the onboard USB
interface – the design of the VALI range is focused on ease of installation,
ease of use, monitoring for the customer and greater serviceability.
Versatility
As well as the mix of explosive output and sleek looks, the VALI range
can also be customized to suit any installation. The inclusion of a new
interchangeable nozzle system means the machine is far more versatile
in terms of where it can be positioned within a room and also the type of
coverage it can provide within that space.

7
VALI Range user manual
1. In The Box
Before attempting to install the machine it is advisable to ensure that
you have all the required components. Upon opening your VALI box you
should nd:
x1 off VALI unit (V10/V20)
Check serial labels to ensure the correct voltage
x1 off Grille Plate Assembly
x1 off Installation Bracket
x1 off Manual pack
Warning stickers
CD Rom containing manuals in multible languages
x1 off Accessory Pack
Straight nozzle insert
30 degree nozzle insert
Circlip (x2 off)
M4x10 black taptite screws (x4 off)
M6x12 black pozi screws (x4 off)
Suppressors
x1 off Cloaksensor (CS07A)
In addition to the above items you will also need 2x 1.2 Ah 12 V
batteries.
MSS Professional A/S recommends FIAMM or similar quality.
In addition, the following specialist tools will also be required: Internal
Circlip Pliers (20 mm)

8 VALI Range user manual
2. Quick Start Guide
To quickly prepare and re your unit, the following
steps should be taken. For more detail on anything
below, see the full guide provided.
3
6
5
4
7
1
Max
2,5 m
Max 3 m
2

9
VALI Range user manual
9
12
16
8
14
11 13
15
Test
10

10 VALI Range user manual
3. Specication
V10 V20
Dimensions (mm) 438 x 340 x 176 488 x 340 x 176
Weight (install) 11.65 kg 14.1 kg
Weight (shipped) 21.2 kg + box 24.3 kg + box
Weight (hanging) 20.15 kg 23.15 kg
Performance 405 m3 in 30 s 600 m3 in 30 s
Reaction Time 0.5 s 0.5 s
Fluid Consumption 175 ml in 30 s 260 ml in 30 s
Standard Colour RAL 9016 RAL 9016
Mounting Vertical or Horizontal Vertical or Horizontal
Fluid Reservoir 1.7 L 1.7 L
Heat up Time (Rdy)
9 minutes (110 V)
10 minutes, 45 s (208)
9 minutes (230 V)
10 minutes (110 V)
9 minutes (230 V)
15 minutes (110 V)
Heat up Time (Full)
16 minutes 110 V)
19 minutes, 20 s (208 V)
16 minutes (230 V)
11 minutes (208)
15minutes 45 s (208 V)
13 minutes (230 V)
Timer Adjustable Adjustable
Voltage 230 V, 208 V, 110 V Avail-
able
230 V, 208 V, 110 V Avail-
able
Heat Power 110 V 2 x 700 W 2 x 850 W
Heat Power 208/230
V2 x 700 W 2 x 950 W
Power Consumption at
230 V (max) 1.45 KW 2.0 KW
Power Consumption at
208 V (max) 1.2 KW 1.65 KW
Power Consumption at
110 V (max) 1.45 KW 1.8 KW
Standby Power Con-
sumption 85 W 105 W
Current Draw at 230
V (max) 6.4 A 8.85 A
Current Draw at 208
V (max) 5.8 A 7.8 A
Current Draw at
110 V (max) 12.1 A 15 A
Pumps x1 24 V solidstate, variable
output,
x2 24 V solidstate, variable
output,

11
VALI Range user manual
Weight (Install)
Represents the weight of the machine, without the covers on, and without
the batteries or any uid installed.
Weight (Shipped)
Represents the weight of the machine packed within its box
Weight (Hanging)
Represents the weight of the machine, in its armed state hanging on a
wall. That includes covers, Batteries and a full container of uid.
Heat-up time (rdy)
The gure given is a time to ‘ready’ state at an ambient temperature of 20°C
Heat-up time (full)
The gure given is a time to full temperature at an ambient temperature
of 20°C

12 VALI Range user manual
4. Machine Layout
1. Tamper switch
2. Cooling fan
3. Autoreset
4. Heat exchanger
5. Output nozzle
5. Electronics module
(containing main
power board)
6. Batteries
7. Interface PCB
8. Fluid container
9. Grille plate
10. Pump (s)
11. Changeover valve

13
VALI Range user manual
5. Installation
5.1 Prior to Installation
Requirements - UK installations
In the UK the installation must be carried out to conform with British Standard
BS7939:1999 for the installation and maintenance of Smoke Security Devices.
BS7939 installation requirements summary
The installer should, prior to the installation liaise with the local re
authority to ensure that there are no local restrictions in force.
The installation should only be conducted by trained personnel who have
passed a written test.
The SmokeCloak should be congured so that it can only activate when
the burglar alarm is set. The SmokeCloak must not be congured to form
a “man-trap” i.e. activate to cut off a means of escape.
The SmokeCloak should not be installed to cover escape routes and
staircases of areas that are still occupied. Care should be given not to
fog joint access areas of adjoining premises. In multi-occupancy buildings
or in large sites with internally SmokeCloak protected areas, the vapour
must be conned to those areas and must not be allowed to infringe into
public or open areas.
Care must be given to automatic re alarm systems so as not to cause
unwanted or false activations.
Consideration should be given to audible and visual indication of
SmokeCloak activation.
The installer should inform the re brigade, police and monitoring station
of the installation prior to commissioning.
A full test activation should be performed as part of the installation.
For installations outside the UK, please adhere to local standards
* All VALI units are tested according to the EN 50131-8

14 VALI Range user manual
5.2 Position
The VALI can be installed vertically for wall mounting, or alternatively
mounted horizontally for ceiling installations. The VALI’s uid container
design means that no modications are required when changing between
horizontal and vertical mountings.
This equipment should only be installed and connected
to the supply by a suitably skilled and competent
person.
This apparatus must be earthed. Connections are
made to a plug-in terminal block. The SmokeCloak
should be connected to a standard 13 amp fused
spur.
Flexible mains cables must have a minimum cross-
section area of 1.25 mm2 (and must be BASEC
approved in the UK). Ensure that the protective
earth conductor is made longer than the live and
neutral conductors, and that the cable clamp grips
both the sheath and insulation.
5.3 Torque Settings
In order to avoid damaging some of the internal xings and components it
is important that the specied torque settings are not exceeded.
Unless otherwise stated within this manual, the maximum torque to be
used for all xings within the VALI machine should be 1.2 Nm

15
VALI Range user manual
5.4 Mounting the machine
1. Screw the installation bracket to the wall/ceiling Horizontal: 6 mm
threaded hanging bars should be used. These should be located on
the slots at the ends of the hanging bracket and tightly fastened into
position.
2. Ensure that the cables are routed through the bracket and fed through
the grommet bushes. The access hole in the installation bracket
should allow the cables to be easily fed into position.
3. Offer the machine into place and push back until you feel it slide into
position.
4. Use the 4 xing points to secure the machine in position.
5. Follow the instructions for wiring and connecting the machine.

16 VALI Range user manual
Wall mounting: It is not recommended to install
the machine in excess of 2.5 m high, otherwise the
smoke coverage near the oor may be compromised.
Horizontal mounting: Ensure the machine is no
more than 3 m above the oor, otherwise smoke
dispersal may be compromised.

17
VALI Range user manual
6. Choosing and
changing the nozzle
VALI will come as standard with no nozzle installed. It is the
job of the installer to assess, install and test which of the
nozzles supplied should be used in order to ensure that the
machine is best suited to the particular installation.
Straight Nozzle Provides a single powerful burst directed
perpendicular to the front of the
machine.
30-Degree Nozzle Provides a single powerful burst
directed at 30° to the front plane of the
machine.
Note: by changing the orientation of
the nozzle the effect can be projected
in varying directions.

18 VALI Range user manual
7. Installing the correct nozzle
for the rst time:
1. By making a quick assessment of the area to be protected by the
SmokeCloak, decide which of the two available standard nozzles
should be used. You can see examples on the previous page.
2. Remove the warning label
3. Take the required nozzle and install it within the nozzle body.
4. Take the circlip provided and using a pair of internal circlip pliers,
engage the circlip into the ridge running around the inside of the
nozzle body. It is crucial this is installed correctly in order to retain the
nozzle safely.
5. Once the nozzle is correctly engaged, install the grille plate using the
4x black taptite screws found in the accessory pack. It is important
that the suggested torque settings are adhered to.
6. Follow the test procedure.
Take great caution when changing the nozzle, it
becomes extremely hot as the machine heats up.
Do not attempt to handle the nozzle once the
machine has heated up to temperature.
Following any installation or changing of the nozzle
– Ensure that a test ring is carried out to ensure
that the new nozzle has been correctly and safely
installed. When performing this rst test ring
insure that the grille plate is installed correctly and
everybody is standing back from the front of the
machine.

19
VALI Range user manual
8. Fluid
FL600-V uid is used to generate the vapour cloud. This glycol based
uid is made to a special formula, which is designed to produce 40%
obscuration of light at 40 cm with minimum condensation.
8.1 Installing the Fluid Bottle
Your VALI product will be supplied with a full uid container installed. It
will arrive with a sealed travel cap installed. The following steps should
be taken in order to correctly install the uid bottle and the uid sensing unit.
1. Remove the uid bottle from the machine,
2. Slide the uid sensor assembly inside the bottle – screw down the cap
tightly to create a seal.
3. The bottle can then be slid back into position within the machine.
4. Connect both the uid sensor wire and the quick release uid line
coupler ensuring that it ‘snaps’ rmly back into its engaged position.
5. It is recommended that following any installation of the bottle a short
test re is carried out to ensure the uid line has been correctly re-
installed and to re-prime the uid feed lines.

20 VALI Range user manual
Click
This manual suits for next models
2
Table of contents