Murphy Lube Level Regulator LR857 User manual

Model LR857
■
Eliminates Under/OverFill Due to
“Human Error”
■
Simple Installation
■
Automatically Maintains Lube Level
■
Low Level Switch
■
Models to Fit Varied Applications
■
Positive Sealing Thumb-Valve™
LR857
Description
Murphy LR857 Lube Level Regulator maintains
the crankcase oil level of an engine, pump or
compressor. Adjusted to the correct running-oil-
level, the LR857 will replenish oil as it is used. An
integral, low-level switch will alarm and/or shut-
down the equipment if supply oil is lost and the
equipment continues to use oil.
Application
The LR857 maintains oil level on any size engine,
but is recommended for small to medium volume
applications and installations that require a 3-wire,
snap-action switch.
How the LR857
Maintains Levels
As crankcase oil level drops, the LR857 float also
drops and opens the Thumb-Valve.™ This allows
oil to flow from the supply tank, through the
LR857, and into the crankcase. When proper
level is attained in the crankcase, the LR857 float
rises, causing the Thumb-Valve to close off fur-
ther oil flow.
The simple and unique Thumb-Valve is non-
clogging and provides a positive, leak-free seal.
Flow rate through the 1/8inch (3 mm) orifice is
significant to allow crankcase refill through
the LR857.
Specifications
Inlet Connection: 5/8 in. (16 mm) I.D. hose
Outlet Connection: 3/8 NPT
Snap-switch: SPDT rating 10 A @ 125 VAC;
0.5 A @ 125 VDC; 10 A @ 30 VDC.
Conduit Connection: 1/2 NPT
Case: Die cast aluminum
Lens: Polycarbonate
Float: Brass
Flow Rates (see chart below):
Oil with 0.9 specific gravity @ 70°F (21°C)
Thumb-Valve Operation
As the equipment uses oil, the float falls, provid-
ing immediate level compensation. At FULL
position, the float holds the valve closed. If the
clean oil supply is depleted and oil level contin-
ues to fall, the low level switch will operate an
alarm or equipment shutdown.
Fittings Kit: 15000420
The 15000420 kit is sold separately. It includes
the following items.
Quantity Description
1 1/4 in. (6 mm) O.D copper cane
tube (vent connection)
1 1/4 in. (6 mm) tube x 1/4 male
pipe fitting
1 1/2 in. (13 mm) I.D. hose fitting
(outlet connection)
Warranty
A limited warranty on materials and workmanship is
given with this FW Murphy product. A copy of the
warranty may be viewed or printed by going to
www.fwmurphy.com/support/warranty.htm
0
05
10
15
20
25
0
Flow:
USGPM
Head Pressure–Feet of Oil
Head Pressure–psi
0 psi
9.73 psi
0.2500 0.5000
COM.
N.O.
Low Level
Switch
LR857
Case
Float
Action
Oil Inlet
Thumb-Valve™
FULL
LOW
N.C.
Simplified Drawing of
Thumb-Valve Operation
** Products covered by this bulletin comply with EMC Council directive 89/336/EEC regarding electromagnetic compatibility except as noted.
**
LR-7225B
Revised 03-05
Catalog Section 15
(00-02-0063)
Maintain Lube Level
For vented crankcase use the
cane vent. For sealed
systems, vent must be
piped back to crankcase,
above oil level.
Shutoff
Valve
CLEAN Oil Supply Tank.
Height above LR recommended
2 ft. (0.6 m) minimum and
25 ft. (7.7 m) maximum
Wire to
switch
circuits
LR857
Oil Outlet
Electrical
Conduit
Crankcase
Oil
Inlet
NOTE: LR857 shown mounted
using a pipe bracket.
LR857 Typical
Installation
4.50 in.
(114 mm
)
5.20 in.
(132 mm)
2.
50
in
.
(
64 mm
)
H
o
l
e
.
88
in.
(
22 mm
)
dia
.
1/4-20 NC
2 places
.
3
7
6
in
.
(
10 mm
)
minim
u
m
bottom surface
2 places
1.75 in.
(44 mm)
7.50 in.
(191 mm)
Slot, .390 in. (10 mm)
x 4.71 in. (120 mm)
3 places
6.69 in.
(170 mm)
Slot, .390 in. (10 mm)
x 2 in. (51 mm)
4 places
4.50 in.
(114 mm)
5.19 in.
(132 mm)
4-13/16 in.
(122 mm)
4-15/16 in.
(125 mm)
4-1/2 in.
(114 mm)
Mounting Holes
Plug
1/2 NPT
1/4 NPT
2-25/32 in.
(71 mm)
9/32 in. (7 mm)
Diameter Holes
2 places
5/8in. (16 mm)
I.D. Inlet Hose
Connection
1/4 NPT Internal
Threads
Test
Knob
Plug
3/8NPT
1/2 NPT
Electrical
Conduit
Connection
3/8NPT
Outlet
Connection

How to Order
Specify model LR857
Accessories (Specify part number)
Description Part Number
Fittings Kit 15000420
Pipe Bracket Kit 15000238
Universal Flange Kit 15010224
Replacement Parts (Specify part number)
Inlet Valve Assembly 15000159
Glass and Switch Ass'y 15000100
Lid Assembly 15000161
Float Assembly (Brass-std) 15000941
LR857 Shipping Dimensions: 9 x 5-1/2 x 6 in. (229 x 140 x 152 mm).
LR857 Shipping Weight: 3 lbs. 6 oz. (1.5 kg).
Mounting Brackets with Hardware
Murphy offers two mounting brackets for the LR857. The 15000238 Pipe
Bracket Kit fits a 7/8 in. (22 mm) diameter pipe (see typical installation
below). The 15010224 universal Flange Kit allows various mounting methods.
Dimensions
15000238
Pipe Bracket Kit
15010224
Universal Flange Kit
Additional Hardware Supplied
(2) 1/4-20 x 7/8 inch
(22 mm) screws
(2) 1/4-20 x 1 inch
(25 mm) screws
(4) 1/4-20 hex nuts
(4) 1/4 inch (6 mm)
dia. split washer
Additional Hardware Supplied
(2) 1/4-20 x 1-1/4 inch
(32 mm) bolts
(4) 1/4 dia. flat washer
(2) 1/4-20 hex nuts
(2) 5/16-18 x 1-1/4 inch
(32 mm) bolts
(4) 5/16 dia. flat washer
(2) 5/16-18 hex nuts
LR-7225B page 2 of 2
CONTROL SYSTEMS & SERVICES DIVISION
P.O. Box 1819; Rosenberg, Texas 77471; USA
+1 281 633 4500 fax +1 281 633 4588
e-mail [email protected]
MURPHY DE MEXICO, S.A. DE C.V.
Blvd. Antonio Rocha Cordero 300, Fracción del Aguaje
San Luis Potosí, S.L.P.; México 78384
+52 444 8206264 fax +52 444 8206336
Villahermosa Office +52 993 3162117
e-mail [email protected]
www.murphymex.com.mx
FRANK W. MURPHY, LTD.
Church Rd.; Laverstock, Salisbury SP1 1QZ; U.K.
+44 1722 410055 fax +44 1722 410088
e-mail [email protected]
www.fwmurphy.co.uk
In order to consistently bring you the highest quality, full featured products, we reserve the right to change our specifications and designs at any time.
FW Murphy
P.O. Box 470248
Tulsa, Oklahoma 74147 USA
+1 918 317 4100 fax +1 918 317 4266
e-mail [email protected]
www.fwmurphy.com Printed in U.S.A. 850740B

Other Murphy Plumbing Product manuals

Murphy SM1 User manual

Murphy

Murphy SM1 User manual

Murphy Pulsation Dampener PD8100 Series User manual

Murphy

Murphy Pulsation Dampener PD8100 Series User manual

Murphy Pneumatic Valves M2582-P User manual

Murphy

Murphy Pneumatic Valves M2582-P User manual

Popular Plumbing Product manuals by other brands

Anzzi MONTAIGNE V-MRCT1030 Install & Operation Manual

Anzzi

Anzzi MONTAIGNE V-MRCT1030 Install & Operation Manual

Aqualisa Visage installation guide

Aqualisa

Aqualisa Visage installation guide

Nemo GO AVA01 manual

Nemo

Nemo GO AVA01 manual

KADANT ELSJ Repair instructions

KADANT

KADANT ELSJ Repair instructions

Axor Starck  10801000 Instructions for use/assembly instructions

Axor

Axor Starck 10801000 Instructions for use/assembly instructions

Luxart Lumino LUM341-PS Installation

Luxart

Luxart Lumino LUM341-PS Installation

OLI NO-TOUCH user manual

OLI

OLI NO-TOUCH user manual

Kebo F-5121-3 manual

Kebo

Kebo F-5121-3 manual

Bristan Java J BF C Fitting instructions

Bristan

Bristan Java J BF C Fitting instructions

Svedbergs Nice 96956 quick start guide

Svedbergs

Svedbergs Nice 96956 quick start guide

saunalife Garden Series manual

saunalife

saunalife Garden Series manual

STROMBERG CELSIUS OVAL Assembly & Operating Instruction

STROMBERG

STROMBERG CELSIUS OVAL Assembly & Operating Instruction

Hornbach 47608-2008 Building instructions

Hornbach

Hornbach 47608-2008 Building instructions

Reece Mizu quick guide

Reece

Reece Mizu quick guide

American Standard 8340.235.002 installation instructions

American Standard

American Standard 8340.235.002 installation instructions

Aqualisa HiQu HQD1005 installation guide

Aqualisa

Aqualisa HiQu HQD1005 installation guide

BELLOSTA 4640/E Installation instruction

BELLOSTA

BELLOSTA 4640/E Installation instruction

Gerber G0040500 Installation

Gerber

Gerber G0040500 Installation

manuals.online logo
manuals.online logoBrands
  • About & Mission
  • Contact us
  • Privacy Policy
  • Terms and Conditions

Copyright 2025 Manuals.Online. All Rights Reserved.