PLEAS E READ T HESE INSTRU CTIONS CAREFULLY BEFORE INSTALLATION
IMPORTANT INSTA LLATION INFORMATION
2.Before commencing installaon or repairs, ensure that
power mains are switched off. Only registered or licencesed
electricians are allowed to conduct installaon or repairs.
3.Light fixture should not be installed nearby or on flammible
materials and must be installed away from heat sources.
4.Recommended installaon height above lighted area:
6-40 meters.
5.All light fixtures run hot therefore the space surrounding the
light fixture shall have adequate airflow spacing of at least 50cm
omni-direconally from the outer case. Fire hazards and local
safety ordinances shall be taken into consideraon by the
installer before commissioning.
LEAVE A COPY FOR THE USER / MAINTENANCE ENGINEER
FOR FU TURE R EFERENCE
W
L
H
1
Pole
Locking bolts
Locking nuts
Rotatable tenon
2
Mains power supply cord
3
Screws to adjust and lock rotatable
tenon
4
ST EP 1:
Loosen locking bolts, then connect the mains power supply cord.
See Figure 1.
ST EP 2:
Ensure to slide fixture to the inner end of tenon,then ghten
locking bolts with 45 n.m of force.
ST EP 3:
Loosen the screws on both sides of the rotatable tenon, rotate
the light body to a specific aiming direcon for illuminaon,
then secure the screws with 25 n.m of force. ST EP 4:
Installaon is completed. See Figure 4.
*The external flexible cable or cord of this luminaire cannot be replaced; if the cord is damaged, the luminaire shall be destroyed.
Terminal block not included, Installaon may require advice from a qualified person.
-90°
0°
+90°
0°
*0~ 90 degrees adjustable
Installaon Instrucon & Installaon Steps
Terminal Block
LIVE
GROUND
NEGATIVE
LIVE - Black
NEGATIVE - White
GROUND-Housing
LED DrivER
Mains power supply
Electrical Connecons
L
G
N
ST EP5:
Reference “Electrical Connecons” secon for compleng electrical connecons.
See Figure 5.
INSTA LLATION INSTRUCTION
MLLG-AX-LED-HM-600-5000-PM
Drawings herein for MLLG-AX-LED-HM-600-5000-PM are used as examples for all the
below listed models
5
1.Normal operang environment and temperature:
-40℃-+50℃. Fixtures is suitable for Airport, Car Dealerships,
Achitural, Municipal, Parking lot, Stadium, and Port lighng.
Main specificaons:
Common causes and solution
Encountered Problem
Possible Cause
Remedy
Module does not light up
Internal wire disconnected
Open fixture and locate loose wires, reconnect connectors or wires and close
cover. And retest.
LED driver failure
Open fixture and check for disconnected wiring. If all wires are fine, replace LED
driver with new one and test.
Module Failure
If all the above remedies are trialed then the light module has most likely failed.
Contact us for replacement and warranty information.
Model No.
No. of LEDs
System Waage
Dimensions (L x W x H)
Net Weight
EPA*
Working Environment
IP
ML LG-A X-LED-HM-450-5000-PM
216
485W
766(30.16") x 634.5(24.98") x 70 mm(2.76")
18.39Kg(40.54 Ibs)
0.678sq.
-40℃-+50℃
IP67
ML LG-A X-LED-HM-600-5000-PM
288
645W
885(34.84") x 634.5(24.98") x 70 mm(2.76")
22.0kg(48.50 Ibs)
0.735sq.
ML LG-A X-LED-HM-750-5000-PM
360
802W
1065(41.9") x 634.5(24.98") x 70 mm(2.76")
27.36kg(60.32 Ibs)
0.843sq.
ML LG-A X-LED-HM-900-5000-PM
432
964W
1185(46.7") x 634.5(24.98") x 70 mm(2.76")
29.90kg(65.92 Ibs)
0.919sq.
120-277VAC or 220-240VAC,75W/module
The ingress protecon of the fixture is IP67 if the mains supply cable's specificaon is H07R N-F 3*1.5mm²
WIRING INSTRUCTION
STEP I: Connect the LIVE wire in the mains power supply cord to the
“L” marked hole In the terminal block and tighten the connection
properly.
STEP II: Connect the NEGATIVE wire in the mains power supply cord to
the “N” marked hole in the terminal block and tighten the connection
properly.
STEP III: Connect the YELLOW/GREEN GROUNDING wire in the mains
power supply cord to the “G” marked hole in the terminal block and
tighten the connection properly.
This logo indicates that this product must not be disposed of with other waste.
Please recycle used lamps to prevent environmental hazard and threats to human
health resulting from improper disposal.

This manual suits for next models

3

Other My LED Lighting Guide Floodlight manuals

My LED Lighting Guide MLLG-AX-LED-HM450-5000-U User manual

My LED Lighting Guide

My LED Lighting Guide MLLG-AX-LED-HM450-5000-U User manual

Popular Floodlight manuals by other brands

Chamberlain Secure Home SH-9191AU Installation and operating instructions

Chamberlain

Chamberlain Secure Home SH-9191AU Installation and operating instructions

LDDE MKII SWMKII-I-118-RGB/B user manual

LDDE

LDDE MKII SWMKII-I-118-RGB/B user manual

Conrad 57 50 73 operating instructions

Conrad

Conrad 57 50 73 operating instructions

ARRI 1250 operating instructions

ARRI

ARRI 1250 operating instructions

Varytec LED Mini Matrix 5x5 2700K user manual

Varytec

Varytec LED Mini Matrix 5x5 2700K user manual

IVT PL-838B operating instructions

IVT

IVT PL-838B operating instructions

Elation STAGE SETTER-24 user manual

Elation

Elation STAGE SETTER-24 user manual

Chauvet Techno Strobe 168 Quick reference guide

Chauvet

Chauvet Techno Strobe 168 Quick reference guide

DTS Dmx Strobe 1500 user manual

DTS

DTS Dmx Strobe 1500 user manual

RAB RFL3 Installation instructions manual

RAB

RAB RFL3 Installation instructions manual

Chauvet DJ Intimidator Spot 360X Quick reference guide

Chauvet DJ

Chauvet DJ Intimidator Spot 360X Quick reference guide

MAXSA 40227 Assembly & operating instructions

MAXSA

MAXSA 40227 Assembly & operating instructions

REV Ritter HFGT120ABW Operation and maintenance manual

REV Ritter

REV Ritter HFGT120ABW Operation and maintenance manual

Corvi Flood Light 25 instruction sheet

Corvi

Corvi Flood Light 25 instruction sheet

Xtralite NiteSafe X2 quick start guide

Xtralite

Xtralite NiteSafe X2 quick start guide

ARRI M90 - Service manual

ARRI

ARRI M90 - Service manual

Scanic Quattro Scan R/G instruction manual

Scanic

Scanic Quattro Scan R/G instruction manual

Kosnic DEL80-W30 quick start guide

Kosnic

Kosnic DEL80-W30 quick start guide

manuals.online logo
manuals.online logoBrands
  • About & Mission
  • Contact us
  • Privacy Policy
  • Terms and Conditions

Copyright 2025 Manuals.Online. All Rights Reserved.