myBeat WHS-2 User manual

Heart rate sensor
Operation Manual
Warranty
Please be sure to read this manual before
using the product.
This product is
not a medical equipment. It is not an instrument for the
prevention of disease.
Please prepare an electrode pad when using this product.
Please do not duplicate, reprint, or reform this product, including accessories without permissio
For the purpose of product improvement specifications of this product including accessories may change without prior
notice.
The life expectancy of this product is
six years
Never detach the seal that is attached to sensor body. Inability to confirm the contents of the seal can lead to punishment
following the Radio Law
, or you may be refused product r
Safety Precautions
Please read carefully to use the product correctly and safely.
Before Using The Product
Battery will drain even when power is OFF.
It is necessary to ensure that a
device
communicates with the product
corresponds
the Bluetooth ®v4.0.
Prepare either of the electrode pads on
the right.
LED Lamp Display
●Green Light ON*1Cardiac
waveform mode start up or measurement in progress.
Starting
RR interval
●Green Light Blink*1*2RR interval
mode measurement in progress
(Biological Signal present
●Yellow Light ON
Starting Setting mode
●OFF Power Off
*1
Displays only for 60 seconds after the power button is pressed, and intermittent lighting every 5 seconds thereafter.
intermittent lighting, and displays for 60 seconds
operating state
※When disconnecting micro-
USB cable from the sensor, the LED Lamp
WARNING
NEVER attach this product to the body during charging. There is a
Please do not use (including health appliances) medical equipment that could be sensitive to electromagnetic wave, such as
implantable cardioverter defibrillators and implantable cardiac pacemakers. That may cause malfunctioning o
instruments.
This product has a built-in lithium-
ion battery
fire, or subject it to violent impact. That may cause of overheating, rupture or ignition of the battery.
If
you feel heating or abnormal odor when using, charging or storage of this product, please disconnect it from the
surrounding and stop using it.
CAUTION
Please do not use for any purpose other than the originally intended as that may cause damage to the product.
Please store in a place out of the reach of children.
micro-
USB Please connect or disconnect the cable holding the sleeve portion with a dry han
The set includes:
Heart rate sensor WHS-2 1unit, micro-USB cable
Thank you for purchasing our products.
This product is a Bluetooth®
Smart heart rate sensor of the type used by pasting directly unto the chest of a person using the
electrode pad.
It can detect heart rate (RR interval or cardiac waveform), body surface temperature and three
By utilizing re
levant applications installed on smart phones and tablets, it is possible to observe daily biological information.
― Electrode Specification ―
1
Heart rate sensor
WHS-2
Warranty
using the product.
not a medical equipment. It is not an instrument for the
purpose of diagnosis, treatment, or
Please prepare an electrode pad when using this product.
[Recommended :
myBeat Disposable electrode
Please do not duplicate, reprint, or reform this product, including accessories without permissio
For the purpose of product improvement specifications of this product including accessories may change without prior
six years
.
Never detach the seal that is attached to sensor body. Inability to confirm the contents of the seal can lead to punishment
, or you may be refused product r
epair or warranty.
Please read carefully to use the product correctly and safely.
Battery will drain even when power is OFF.
After unwrapping the product, please
charge the battery immediately.
device
that
corresponds
to
the right.
waveform mode start up or measurement in progress.
RR interval
mode (No Biological Signal)
mode measurement in progress
(Biological Signal present
)●Green Fast Blink*1*3
Biological Signal Saturation
Starting Setting mode
●Blue Light ON
Charging Battery
●
Red Light Blink or Red Light ON
Displays only for 60 seconds after the power button is pressed, and intermittent lighting every 5 seconds thereafter.
operating state
again. *2Lighting once every 2seconds. *3
Lighting
USB cable from the sensor, the LED Lamp
may blink for a moment.
NEVER attach this product to the body during charging. There is a
risk of electric shock.
Please do not use (including health appliances) medical equipment that could be sensitive to electromagnetic wave, such as
implantable cardioverter defibrillators and implantable cardiac pacemakers. That may cause malfunctioning o
ion battery
.
Please do not wet the product with water and other liquids, bring it close to
fire, or subject it to violent impact. That may cause of overheating, rupture or ignition of the battery.
you feel heating or abnormal odor when using, charging or storage of this product, please disconnect it from the
Please do not use for any purpose other than the originally intended as that may cause damage to the product.
Please store in a place out of the reach of children.
USB Please connect or disconnect the cable holding the sleeve portion with a dry han
d.
(for charging)
1pc, Storage bag 1pc, myBeat Disposable electrode 1pc, Operation Manual 1pc
Smart heart rate sensor of the type used by pasting directly unto the chest of a person using the
It can detect heart rate (RR interval or cardiac waveform), body surface temperature and three
-
axis acceleration of a person.
levant applications installed on smart phones and tablets, it is possible to observe daily biological information.
a.
b. 電池
が
型式
S/
N
MADE IN JAPAN
― Electrode Specification ―
15~30mm
Single Type
20mm
Hook
Electrode Part
purpose of diagnosis, treatment, or
myBeat Disposable electrode
]
Please do not duplicate, reprint, or reform this product, including accessories without permissio
n.
For the purpose of product improvement specifications of this product including accessories may change without prior
Never detach the seal that is attached to sensor body. Inability to confirm the contents of the seal can lead to punishment
charge the battery immediately.
Biological Signal Saturation
Charging Battery
Red Light Blink or Red Light ON
Battery is Low
Displays only for 60 seconds after the power button is pressed, and intermittent lighting every 5 seconds thereafter.
When you press the power switch to
Lighting
5 times every 2seconds.
Please do not use (including health appliances) medical equipment that could be sensitive to electromagnetic wave, such as
implantable cardioverter defibrillators and implantable cardiac pacemakers. That may cause malfunctioning o
f such
Please do not wet the product with water and other liquids, bring it close to
fire, or subject it to violent impact. That may cause of overheating, rupture or ignition of the battery.
you feel heating or abnormal odor when using, charging or storage of this product, please disconnect it from the
Please do not use for any purpose other than the originally intended as that may cause damage to the product.
Sleeve
1pc, Storage bag 1pc, myBeat Disposable electrode 1pc, Operation Manual 1pc
Smart heart rate sensor of the type used by pasting directly unto the chest of a person using the
axis acceleration of a person.
levant applications installed on smart phones and tablets, it is possible to observe daily biological information.
a. LED Lamp
b. Power Button
c. Electrode pad
Mounting hook
R123-XX4567
が
切れたら早めに充電してください
型式
WHS-2
N
0040000001
MADE IN JAPAN
c.
Pair Type
Do not Overlap 15~30mm
Electrode Part

How to Use
If you notice any skin trouble after attaching the product, stop using immediately and consult a doctor.
Power
Operation
Power ON
Press Power button
Power OFF
Power button for more than 3 seconds
Attaching
The Product
Before wearing the product,
confirm how to use.
When the LED lamp does not blink green, please change the mounting position by referring to the
following.
Measurement
Download the right application for your terminal, Please operate according to the method of operation of
the application.
Download from App Store or
Measurement data can be saved to CSV and exported
*4O
peration confirmed models of Android
Cannot guarantee
the operation of models other than the confirmed models.
Battery
Charging
Please charge through
one
Blue Light ON:
Charging Battery
Ⅰ. C
harge from Computer
Application
Development
Depending on the intended use of this sensor, you can create a dedicated application on your own. If you
wish to develop the application, please refer to the dedicated
※
Knowledge of application development is required.
LED lamp
w
hen the Green Fast Blink
Please move up
the mounting position.
Ⅰ. >>>
Attach the Electrode pad
to the sensor.
Standard App
「myBeat」
2
If you notice any skin trouble after attaching the product, stop using immediately and consult a doctor.
Press Power button
(less than 3 seconds), LED Lamp turns on
Power button for more than 3 seconds
, LED Lamp turns off
Before wearing the product,
see the Operation Manual
of the electrode pads you are using, please use it to
When the LED lamp does not blink green, please change the mounting position by referring to the
Download the right application for your terminal, Please operate according to the method of operation of
Download from App Store or
Google play®free of charge.
Measurement data can be saved to CSV and exported
.
peration confirmed models of Android
:Nexus7 2013、Nexus5、GALAXY SⅢα SC-
03E
the operation of models other than the confirmed models.
one
of the following.
Charging Battery
Light OFF:Complete
harge from Computer
Using a micro-USB
cable, connect the
micro-USB
connector to the
sensor, insert the
USB connector
unto the computer.
Ⅱ.
Charge with USB AC Adapter (Sold Separately)
It is recommended to use a double insulated AC adapter.
Depending on the intended use of this sensor, you can create a dedicated application on your own. If you
wish to develop the application, please refer to the dedicated
information site:
Knowledge of application development is required.
hen the Green Fast Blink
the mounting position.
LED lamp
when the Green Light ON
with RR interval mode
Please move down or move to the left
and right to the extent that the central
portion of the electrode on the right side
does not protrude past the body cente
r
line.
Still LED lamp when the Green Light ON
Please move to the height of pit of the
stomach
extent that the central portion of the
electrode on the right side does not
protrude
Ⅱ.>>>
Turn Power On and
confirm that the LED
lamp lights up in green
color.
From the app or LED
lamp, confirm that
there is enough battery
power left.
Attach the Electrode pad
Ⅲ. >>>
Peel off the protective sheet of electrode pads, and
paste the
adhesive surface of the electrode pad
directly un
to the left chest.
make sure that the LED lamp is blinking green.
As a measure of the
height
portion of the
electrode
middle of the co
llarbone
following values.
Height less than
170cm:80mm
central portion
of collar bone
Pit of the
stomach
Reference height
80~100mm
100V
USB AC
Adapter
Double insulation
If you notice any skin trouble after attaching the product, stop using immediately and consult a doctor.
of the electrode pads you are using, please use it to
When the LED lamp does not blink green, please change the mounting position by referring to the
Download the right application for your terminal, Please operate according to the method of operation of
03E
、GALAXY J SC-02F
Charge with USB AC Adapter (Sold Separately)
Use a micro-USB cable to
connect the micro-USB
connector to the sensor.
insert the USB connector
unto the AC adapter.
It is recommended to use a double insulated AC adapter.
Depending on the intended use of this sensor, you can create a dedicated application on your own. If you
information site:
【https://github.com/myBeat 】
Still LED lamp when the Green Light ON
Please move to the height of pit of the
stomach
,
and to the left and right to the
extent that the central portion of the
electrode on the right side does not
protrude
past the body center line.
Peel off the protective sheet of electrode pads, and
adhesive surface of the electrode pad
to the left chest.
At this time, please
make sure that the LED lamp is blinking green.
height
, distance to the
central
electrode
on the right side from
the
llarbone
, please refer to
the
170cm:80mm
more than 170cm:100mm
Effective
Mounting
Range
Pit of the
stomach
central portion of
right side electrode

3
Maintenance and Storage
Wipe it with dry cloth on a regular basis, and always use it in clean condition.
Storage Environment:Temperature -10℃~+50℃, Humidity 30%~80%RH (Non-condensing)
For long-term storage, please keep it in a well-ventilated place and avoid direct sun rays.
Even when not using for a long-term, to avoid battery over discharge, Charge the battery fully once a month.
Please dispose of in accordance with the provisions of local regulations.
Specifications
Measurement Item Cardiac waveform or RR interval(Heart rate), Body surface Temperature, 3-axis acceleration (±4G)
Dimensions, weight H 41×W 37.5×Thickness 10 (mm), 13.7g
Communication Bluetooth®Smart
Internal Battery Rechargeable lithium-ion battery charging time: 3 hours
Battery Life Cardiac waveform measurement 20 hours, RR interval measurement 40 hours
Use Environment Temperature+5℃~+45℃, Humidity 30%~80%RH (Non-condensing), Splash-proof construction
Cardiac waveform RR interval
Heart rate Sampling frequency 40Hz 1000Hz
Data update rate 25ms On each Heart rate
Acceleration Sampling frequency 40Hz 31.25Hz
Data update rate 25ms On each Heart rate
Body surface Temperature Sampling frequency 1Hz 1Hz
Data update rate 1sec On each Heart rate
Data transmission rate 50ms On each Heart rate
Regulations
FCC FCCID:2ACS48600043
This device complies with part 15 of the FCC Rules. Operation is subject to the following two conditions: (1) This device may not cause
harmful interference, and (2) this device must accept any interference received, including interference that may cause undesired operation.
FCC CAUTION:Changes or modifications not expressly approved by the party responsible for compliance could void the user’s authority
to operate the equipment.
This equipment has been tested and found to comply with the limits for a Class B digital device, pursuant to part 15 of the FCC Rules.
These limits are designed to provide reasonable protection against harmful interference in a residential installation. This equipment
generates, uses and can radiate radio frequency energy and, if not installed and used in accordance with the instructions, may cause harmful
interference to radio communications. However, there is no guarantee that interference will not occur in a particular installation. If this
equipment does cause harmful interference to radio or television reception, which can be determined by turning the equipment off and on,
the user is encouraged to try to correct the interference by one or more of the following measures:
—Reorient or relocate the receiving antenna.
—Increase the separation between the equipment and receiver.
—Connect the equipment into an outlet on a circuit different from that to which the receiver is connected.
—Consult the dealer or an experienced radio/TV technician for help.
This transmitter must not be co-located or operated in conjunction with any other antenna or transmitter.
This equipment complies with FCC radiation exposure limits set forth for an uncontrolled environment and meets the FCC radio frequency
(RF) Exposure Guidelines. This equipment has very low levels of RF energy that are deemed to comply without testing of specific
absorption ratio (SAR).
EU
UNION TOOL declares that this Heart rate Sensor is in compliance with the mandatory requirements and other relevant provisions of the
R&TTE Directive.

4 20014/9(1)
Limited Warranty
In case of damage, please check the contents of the warranty certificate and contact the place you bought the product from, or
the contact address stated below.
Warranty Certificate
Warranty Period On year from date of purchase
Date of Purchase Y / M / D
Object of Warranty Heart rate sensor WHS-2 main instrument
Terms of Warranty
■If within the warranty period, the product has been used correctly as stated in this manual or
as described in the application of purpose, but the product gets damaged, we will repair or
exchange the product free of charge.
■The product repair may entail the use of alternate parts, or in some cases where the repair is
difficult, it can be replaced with equivalent products.
■The holding period of (parts required to maintain the function of the product) repair parts, is
at least six years from when the sale of this product is discontinued. The product will only be
repaired within this holding period.
■Even if within the warranty period, the warranty will be void in the following cases:
○Damage resulting from inappropriate handling at the time of movement or transportation after the
product is purchased. ○Damage resulting from unlawful remodeling or repair of the product. ○Damage
resulting from battery leakage. ○Damage due to fire, earthquake, flood, and other natural disasters or
due to abnormal voltage. ○The warranty certificate is not presented, or the necessary information is not
specified in the certificate warranty, or if the text has been rewritten.
Dealer
Point of Purchase
Shop Name :
Address :
TEL :
FAX :
Buyer Information
Name :
Address :
Contact :
FOR PRODUCT INQUIRIES
MAIL http://www.uniontool.co.jp >Contact us >For Products Information
FAX 81-3-5493-1014
6-17-1 Minami-Ohi, Shinagawa-ku, Tokyo 140-0013 JAPAN
TEL 81-3-5493-1023
URL http://www.uniontool.co.jp
The Bluetooth®word mark and logos are registered trademarks owned by Bluetooth SIG, Inc.
App Store is service marks owned by Apple Inc.
Google Play and Android are trademarks or registered trademarks or service marks owned by Google Inc.
GitHub is trademarks owned by GitHub Inc.
iOS is used under license owned by Cisco in the United States and other countries.
Facebook is registered trademarks owned by Facebook, Inc.
myBeat is registered trademarks owned by UNION TOOL CO. in the Japan.
Table of contents
Popular Heart Rate Monitor manuals by other brands

iHealth
iHealth AM3 quick start guide

Sportline
Sportline DUO 1025 user manual

Crivit
Crivit 1-LD3945 Usage and safety instructions

Sportline
Sportline S7 instruction manual

Preventice Solutions
Preventice Solutions BodyGuardian MINI Patient Instruction Manual

Oregon Scientific
Oregon Scientific HR102 user manual