MYPV AC-THOR i User manual

AC•THOR®i Assembly Instructions, Version 210326
1
Assembly Instructions
AC•THOR®i
Photovoltaic Power Manager
In addition to these assembly instructions, the
current version of the Operating instructions
for the device is available at www.my-pv.com.
Wiring diagrams at the end of the document.
The following device key is required for online
registration of the unit. Keep it safe!
Device key:
Required for cloud service
registration
at www.my-pv.live

AC•THOR®i Assembly Instructions, Version 210326
2
Manufacturer
my-PV GmbH
A: Teichstraße 43, 4523 Neuzeug, Austria
W: www.my-pv.com.au | E: info@my-pv.com
Australian & New Zealand Distributor
Energy Smart Water Pty Ltd ABN 65 161 756 690
A: 2/11 Dalkeith Drive, Dromana Vic 3936, Australia

AC•THOR®i Assembly Instructions, Version 210326
3
Contents
Manufacturer ................................................................................... 2
Australian & New Zealand Distributor............................................... 2
1. Operation manual................................................................... 5
2. Intended use........................................................................... 5
3. Scope of supply....................................................................... 6
4. Safety instructions .................................................................. 7
5. Connections overview............................................................. 9
6. Mounting................................................................................ 9
7. Electrical connection............................................................. 11
7.1. Connecting temperature probes ..................................12
7.2. Electrical connection for multiple units ........................13
8. Operation displays................................................................ 13
9. Maintenance ........................................................................ 14
10. Troubleshooting ................................................................... 14
11. Disposal................................................................................ 15
12. Warranty .............................................................................. 15
12.1. Warranty –General......................................................15
12.2. Terms of Warranty.......................................................15
12.3. Warranty Exclusions.....................................................16
12.4. How to make a warranty claim.....................................17
12.5. Purchaser’s Statutory Rights ........................................17
13. EU declaration of conformity ................................................ 18
14. Technical specifications ........................................................ 19

AC•THOR®i Assembly Instructions, Version 210326
4
15. Wiring diagrams.................................................................... 20
15.1. AC•THOR®i - Wiring the control side............................20
Power Meter –connection via router...........................20
Power Meter –connection without router...................21
Power Meter –connection without router via
powerline ....................................................................22
Control by inverter or battery management.................23
Control by the energy management system.................24
15.2. AC•THOR®i Wiring applications....................................25
Operating mode M1: Hot water 3 kW ..........................25
Operating mode M2: Hot water stratification charge ...26
Operating mode M3: Hot water 6 kW ..........................27
Operating mode M4: Hot water + heat pump...............28
Operating mode M5: Hot water + space heating ..........29
Operating mode M6: space heating .............................30
Connecting three-phase heating elements...................31

AC•THOR®i Assembly Instructions, Version 210326
5
1. Operation manual
In addition to these assembly instructions, the current version of the
Operating instructions for the device is available at www.my-pv.com.
Wiring diagrams at the end of the document.
2. Intended use
The electronic AC•THOR®i Photovoltaic-Power-Manager (in the following,
AC•THOR®i for short) is designed for operating resistive loads such as
electric immersion heater elements, electric boilers, electric convectors,
electric heating mats or infrared panels. The unit controls the output voltage
according to external signals (temperatures, Ethernet- and other control
signals) linearly and thus the power output of the connected load.
The AC•THOR®i is controlled by the my-PV Power Meter or can be
combined with products such as inverters of different manufacturers (the
current list of manufacturers can be seen at https://www.my-
pv.com/en/info/compatible-manufacturers .
The AC•THOR®i is designed for fixed installations indoors.

AC•THOR®i Assembly Instructions, Version 210326
6
Installation in rooms with high levels of humidity must comply with the
relevant regulations.
The ACTHOR has an ambient temperature rating of 0°C -40°C. If installed
outdoors it must be able to function within this temperature range and be
located in a shaded position inside an IP55 rated waterproof cabinet which
allows airflow around the unit. Forced ventilation may need to be
considered. Contact tech support for further advice regarding installing the
unit in an outdoor enclosure.
Any application other than those described above may cause damage.
Furthermore, this may lead to hazards such as a short circuit, fire, electric
shock, etc. The safety instructions and the information on handling in this
manual and in the Operating Instructions must be followed!
The product complies with the statutory, national, and European
requirements. The names of the company and products are trademarks of
my-PV GmbH. All rights reserved.
You will find a comprehensive description of the device’s functions and
settings using the display or via web interface in the Operating Instructions.
3. Scope of supply
AC•THOR®i Electronic Photovoltaic Power Manager
Wall bracket (on the rear of the unit)
Assembly set (3 screws 4.2 x 32 mm, 3 wall-plugs 6 mm)
my-PV digital temperature sensor (cable length 5 m) with 8-pin
plug
Power supply 3 poles for 16 A switch output 2.8m (attached to the
unit)
European plug contact for resistive load
Operator stylus for the display with holder
Assembly Instructions
Key-fob AC•THOR

AC•THOR®i Assembly Instructions, Version 210326
7
Optional Accessories Available (not included)
my-PV Power Meter
my-PV digital temperature sensor (cable length 5 m) with 8-pin plug
4. Safety instructions
Installation must be carried out by a licensed electrician in
accordance with AS/NZS 3000.
For water heating applications compliance with AS/NZS 3500 is
required.
Do not open the AC•THOR®i. The device does not contain any parts
that may be repaired by the user.
Only pure resistive electric loads (230VAC 3000W max., 240VAC
3600W max.) such as immersion heater elements, boilers,
convectors, heating mats or infrared panels can be connected to
the AC•THOR®i.
The loads connected must be suitable for variable supply voltages
between 0-230/240 VAC (in no circumstances units with electronic
power supply!).

AC•THOR®i Assembly Instructions, Version 210326
8
All connected devices must be operated with phase and neutral
conductor.
Never connect three phase loads without neutral conductor!
Otherwise this may cause damage to the AC•THOR®i or to the
other loads connected to it.
Only the supplied plugs must be used for connection to the
AC•THOR®i.
Operation of heating systems incorporating electronic thermostats
is not possible.
For heating water, only heaters with an integral safety temperature
limiter may be connected.
The AC•THOR®i is designed for fixed installations indoors.
Comply with the relevant standards when mounting and
connecting the device.
The AC•THOR®i housing may heat up during operation. Only mount
the unit on non-combustible surfaces.
The AC•THOR®i is only intended for use in dry rooms indoors.
Otherwise there is a risk of fatal electric shock!
Installation in rooms with a high level of humidity must comply
with relevant regulations.
Do not install the device in an environment contaminated with
ammonia.
Do not install the device in a dusty environment.
The ventilation holes of the housing must not be covered.
Avoid exposure to high temperatures (> 40 °C), low temperatures
(< 0 °C) or direct sunlight during storage and operation.
The AC•THOR®i must be connected to a nominal voltage of
230/240 V AC, 50/60 Hz. The neutral conductor is necessary!
Protection of the mains connection for the AC•THOR®i may not
exceed 16 A per phase (tripping characteristic B or C).

AC•THOR®i Assembly Instructions, Version 210326
9
5. Connections overview
6. Mounting
1. Remove the wall bracket from the rear of the AC•THOR®i unit. To
do this, slide the lock underneath to the right.
Sensors
230VAC 3.000 W max.
240VAC 3.600 W max.

AC•THOR®i Assembly Instructions, Version 210326
10
2. Then fix the wall bracket to the wall with three screws. Three
screws and three wall-plugs are supplied. If the screws supplied are
not suitable for the substrate, suitable screw must be obtained.
3. To fix it to the wall bracket, the AC•THOR®i is suspended in the wall
bracket by the two long slots on top and then fixed in place by
locking it underneath (slide to the left).
4. Check the AC•THOR®i is securely fixed!
5. When installing in an electrical cabinet, ensure sufficient cooling,
for example through ventilation slots in the switch cabinet door.
6. A minimum lateral distance of 7cm must be observed.
7. When installing several devices side by side, a minimum distance of
10cm must be maintained
8. Then the electrical connections can be made.

AC•THOR®i Assembly Instructions, Version 210326
11
Do not immerse my-PV temperature sensor(s) directly in Water. Use a
thermowell!
7. Electrical connection
The AC•THOR®i is controlled by external signal sources by way of IP protocol
using a standard Ethernet RJ45 cable.
Protection of the mains connection for the AC•THOR®i may not exceed 16 A
per phase (tripping characteristic B or C).
Pay attention to other loads on the line circuit, this may trip the circuit
breaker!
For mains leads, use a cable duct of 60 mm depth. The cut-out
measures 130 x 60 mm.
The PE conductor and the neutral conductor must be connected!
!

AC•THOR®i Assembly Instructions, Version 210326
12
The solar diverter (AC•THOR®i) circuit shall be protected by a 30 mA Type
AC RCD installed in accordance with AS/NZS 3000.
An isolating switch in accordance with clause 4.8.2.3 AS/NZS 3000:2018 shall
be installed for the water heater.
Where more than one circuit can supply the water heater, a warning sign
shall be installed within the installation switchboard that the solar diverter
circuit originates, and on the water heater.
NOTE: The installation of a solar diverter can introduce an unforeseen
hazard, where if the grid supply to the water heater is isolated at the
switchboard, the diverter may still be able to supply power to the water
heater. The warning sign shall state the following:
WARNING solar diverter
installed.
Isolate all supplies before
working on water heater.
Refer to the wiring diagrams provided in section 14 for further detail.
7.1. Connecting temperature probes
Up to four digital temperature probes (three-core, bus system) can be
connected to the AC•THOR®i. The terminal positions for the three cores are
shown in the following illustration.
Do not immerse my-PV temperature sensor(s) directly in water.
Use a thermowell!
!

AC•THOR®i Assembly Instructions, Version 210326
13
7.2. Electrical connection for multiple units
All devices should be connected to appropriate AC circuits. Note that each
AC•THOR®i takes up to 3.6 kW power (with relay output up to 7.2 kW). It
makes sense to divide this between the phases on the grid.
8. Operation displays
The unit has a touch screen to show operating conditions and for ease of
operation.
Never touch the screen with pointed objects or those having sharp edges!
Use the supplied stylus for programming. The holder for the stylus can be
stuck on to a surface on or close to the unit with the adhesive patch. A
detailed description of the graphic user interface, the operating modes, the
If more than one probe is used,
the cores can also be connected
externally in parallel.

AC•THOR®i Assembly Instructions, Version 210326
14
menu guide, and settings are located in the Operating Instructions for the
unit. The current version is available at www.esw.net.au
9. Maintenance
Do not attempt to open the AC•THOR®i. The device does not contain any
parts that may be repaired by the user. In the event of a fault, please
contact Energy Smart Water on 1800 433 254 or email
techsupport@esw.net.au .
Never splash water on or in the unit!
When switched off, the surface of the device can be cleaned either with a
damp cloth, using mild glass cleaner or cleaning tissue for glasses.
In a polluted environment, the air inlets and outlets should be checked
regularly for cleanliness. If necessary, the device can be cleaned through the
air slots with a vacuum cleaner.
The AC•THOR®i cannot work at maximum efficiency if the air supply is
inadequate!
10.Troubleshooting
The device does not contain any parts that may be repaired by the user. In
the event of a fault, please contact Energy Smart Water T 1800 433 254 or
email techsupport@esw.net.au.

AC•THOR®i Assembly Instructions, Version 210326
15
11.Disposal
Packaging material must be either stored or disposed of as appropriate.
Dispose of the AC•THOR®i at the end of its service life according to the
statutory regulations.
12.Warranty
12.1. Warranty –General
This warranty is given by Energy Smart Water Pty. Ltd., 2/11 Dalkeith Drive,
Dromana Vic 3936, Australia, ABN 65 161 756 690 for installations in
Australia and New Zealand only.
For details about this warranty contact Energy Smart Water on 1800 433
254 or email techsupport@esw.net.au.
This warranty covers any defects in materials for a period of 2 years from
date of purchase when the product is installed and operated according to
the written installation instructions. Energy Smart Water will repair or
replace the covered product or any part or component that is defective in
materials or workmanship subject to the terms within this document.
A call out fee is chargeable where it is found there is no fault with the
product.
If a subsequent version of this warranty is published, the terms of that
warranty will apply after the date specified in the subsequent version.
12.2. Terms of Warranty
Supplied product must only be installed, commissioned, or serviced by a
licensed electrician in accordance with all electrical standards, municipal

AC•THOR®i Assembly Instructions, Version 210326
16
building codes, occupational health, safety & welfare regulations, and other
State or Federal statutory regulations.
Where a failed product is replaced under this warranty, the balance of the
original warranty period will remain effective. The replacement does not
carry a new warranty.
This warranty extends to the original purchaser and subsequent owners, but
only while the product remains at the site of the original installation. The
warranty only extends through the first installation of the product and
terminates if the product is moved or reinstalled.
Replacement of the product may be authorised by Energy Smart Water only.
Energy Smart Water does not authorise any person or company to assume
for it any obligation or liability in connection with the replacement of the
product.
If the product is found to be free of defects in material or workmanship, or
damaged by improper installation, or damaged during return shipping, the
warranty claim for product, parts and labour may be denied.
Where the product is installed outside the boundaries of a metropolitan
area, the cost of travelling to the installed site shall be the owner’s
responsibility.
12.3. Warranty Exclusions
Where the product has not been installed and operated in
accordance with the instructions in this manual.
Where the product is misused, damaged, neglected, abused,
operated outside of instructions in this manual.
Where the defect is caused by improper installation of a third party
product or defective third party product.
Where damage is caused by an act of God, fire, lightning, flood,
earthquake, landslide, storm, hail, frost, wind, or other severe
adverse weather conditions.

AC•THOR®i Assembly Instructions, Version 210326
17
Where the product is located in a position that does not comply
with the installation instructions or relevant statutory
requirements.
Where the product is moved or reinstalled at a new location.
Where the connection, attachment, integration or general
association of other equipment or parts not instructed by this
manual which either directly or indirectly affect the performance or
operation of this equipment.
Altering, disassembling, attempt to repair or otherwise intervening
in the device or making changes to the device without
authorisation.
Any damage or injury caused by improper handling or failure to
observe the assembly and operating instructions.
12.4. How to make a warranty claim
To be entitled to make a claim under this warranty you need to be the
owner of the product or have consent from the owner to act on their behalf
and provide proof of purchase. Provide owner’s details, address of the
device, a contact number and date of installation.
As soon as reasonably practicable you must contact Energy Smart Water on
issue. Energy Smart Water will arrange for the product tested and assessed
on-site.
If Energy Smart Water determines that you have a valid warranty claim, the
unit will be repaired or replaced in accordance with this warranty.
12.5. Purchaser’s Statutory Rights
Our goods come with guarantees that cannot be excluded under the
Australian Consumer Law. You are entitled to a replacement or refund for a
major failure and compensation for any other reasonably foreseeable loss or
damage. You are also entitled to have the goods repaired or replaced if the
goods fail to be of acceptable quality and the failure does not amount to a
major failure.

AC•THOR®i Assembly Instructions, Version 210326
18
The Energy Smart Water warranty is in addition to any rights and remedies
that you may have under the Australian Consumer Law.
13.EU declaration of conformity
my-PV GmbH, Teichstraße 43, 4523 Neuzeug, Austria
hereby declares that the products of the product AC•THOR®i
comply with the following Directives and standards:
EN 55014-1, EN 55014-2, EN 60730-1, EN 62233, EN 61000-3-2,
EN 61000-3-3
The company named above holds available for inspection documentation as
proof of fulfilment of the safety objectives and the principal safety
requirements.
Neuzeug, 09.05.2018 Dr. Gerhard Rimpler, Managing Director

AC•THOR®i Assembly Instructions, Version 210326
19
14.Technical specifications
Mains voltage
230/240 V, 45-65 Hz
Outputs
0 to 230 VAC 3000 W max.
0 to 240 VAC 3600 W max.
pure sine wave
Relay output
1 x NC/NO
20 V AC 100 mA min.
230/240 V AC 16 A max.
Mains connection
3-phase with neutral conductor
Safeguarding
16 A tripping characteristic B, C
Load connection
Plug contacts for resistive loads
Standby consumption
< 1.5 W
Efficiency
> 98 % at rated power
Operating temperature
range
0°C to 40 °C
Permissible RH
0-99 % (non-condensing)
Storage temperature
-20°C to 70 °C
Protection
IP20
Protection class
I
Temperature sensor
my-PV digital temperature sensor (5 m)
Display
Colour graphic, touch screen 2.83“
Warranty
2 Years (extended warranty upon request)
Weight (without wall
bracket)
1.5 kg including lead (without wall bracket)
Dimension (W x H x D)
135 x 195 x 65 mm without mains cable
Interfaces
Ethernet RJ45, RS485, potential-free input,
PWM out, PWM in
Compatible systems
see www.my-pv.com

AC•THOR®i Assembly Instructions, Version 210326
20
15.Wiring diagrams
NOTE: For installations in 240 V grids instead of 3kW loads 3.6kW
loads are allowed!
15.1. AC•THOR®i - Wiring the control side
Power Meter –connection via router
Establishing the automatic connection via router may take as much as a
minute!
Table of contents
Other MYPV Industrial Equipment manuals
Popular Industrial Equipment manuals by other brands

General
General EPIC 262H Operator's manual

Harris
Harris 220 Series Installation and operation manual

Nitta
Nitta PolySprint FP70-10-50 Operation manual

YASKAWA
YASKAWA SI-EN3 installation manual

R.V.R. Elettronica
R.V.R. Elettronica TEX150-LCD/S user manual

Workhorse Products
Workhorse Products Lumitron LED Small owner's manual