Nabco 1175 User manual

Automatic
Entrance
Systems
ELECTRICAL INSTALLATION MANUAL
**SLIDERS**
1510596 Revision 5-18-04
NABCO ENTRANCES INC.
Phone: 877-622-2694 Fax: 888-679-3319
Technical Assistance: 1-866-622-8325
http://www.nabcoentrances.com
Email: [email protected]
WARNING
Do not install, operate or service this product unless you have read and understand the
Safety Practices, Warnings, Installation and Operating Instructions contained in this man-
ual. Failure to do so may result in property damage, or bodily injury.
BLUE
BLUE RED
YELLOW
GREEN
RED
BROWN
PLUG WITHBLUE
JUMPER MUST BE
IN PLACE
NOT USED
RED
YELLOWRED
BROWN
RED
GREEN
ORANGE
BROWN
PLUG WITH BLUE
JUMPERMUST
BEIN PLACE
ACUSENSOR
HARNESS
PT.NO. 229184
BROWN
WIRE NUT
BLUE
BLACK
BLACK
BLACK
"REDUCE"
LEAVE OPEN
EMITTERDETECTOR
BROWN
LIGHT BLUEBROWN
BROWN
INTERIOR ACUSENSOR
PT. NO. 148902
BLACK
BLUE
EXTERIOR ACUSENSOR
PT.NO. 148902
ACUSENSOR
HARNESS
PT.NO. 229184
Teleco Brand Safety Beams
BLUE
WHITE
RED
GREEN
BLACK
BLUE
RED
WHITE
GREEN
BLACK
BLACK 120 VAC "HOT"
120 VAC "COMMON"
SERVICE GROUND
BLACK
BLACK
WHITE
WHITE
BLUE
BLACK
BROWN
RED
GREEN
ORANGE
ORANGE
SWITCH BOX
WIRE NUT
WIRE NUT
CAUTION Forcontinuedprotection
againstfire,replaceonly
withafuseofthesame
typeandrating.
WARNING
NotUsed
115VACCommon
115VACHot
NotUsed
White
Black
1
2
3
4
NO. COLOR USE
MotorVPhase
Encoder12VDC
EncoderAPhase
MotorUPhase
EncoderGround
EncoderBPhase
USE
RedOrange
Brown
BlueBlack
Yellow
1
2
3
4
5
6
NO. COLOR 12VDC+
12VDC-(Common)
InteriorActivationSensor
HoldingBeam
ReducedOpening
ModeSwitch1
ModeSwitch2
ExteriorActivationSensor
AlternatingActivation
BreakoutOutputSwitchHI(Elec.Lock,Airlock,etc.)
OutputSwitchLO(Elec.Lock,Airlock,etc.)
BrownRedBlack
WhiteGreen
Orange
Orange
Orange
Yellow
BlueVioletGray
9DC12V
7
61
6B
H
M0
M1
62
SQ
BA
OUT+
OUT-
1
2
3
4
5
6
7
8
9
10
11
12(SeeModeSwitchTable)
NO. SYMBOLCOLORUSE[SLIDEMODESELECTED]USE[SWINGMODESELECTED]
(SeeModeSwitchTable)
MODESWITCHTABLE
MO
OpenGndGndOpenM1
OpenOpenGndGndModeAuto
ExitHoldOpen
Night
No.
FuseInside
Rating:125V,5A
Size:5.2x 20mm
1. Adjustmentsto the door can only be made with aHandy Terminal.
Noadjustments areavailable insidethe control box.
2. Replaceablefuse located inside the control box.
3. Turnthe power off prior to removing the cover.
4. Thisunitcan notberepaired in the field. Any attempted repairs
byan unauthorized NABCO facility will voidthe warranty.
NABCO248901 Microprocessor Controller 12VDC+
12VDC-(Common)
ApproachActivationSensor
HoldingBeamorSwingSensor
ThresholdSafetyMat
ModeSwitch1
ModeSwitch2
ExteriorActivationSensor
AlternatingActivation
BreakoutOutputSwitchHI(Elec.Lock,Airlock,etc.)
OutputSwitchLO(Elec.Lock,Airlock,etc.)
Power Connector(4pin)
MotorConnector (6pin)
HandyTerminalConnector (6 pin)MainHarness Connector(12 pin)
VIOLET
GRAY
YELLOW NOT USED
ORANGE
NOT USED
NOT USED
WIRE NUT
WIRE NUTWHITE
MOTOR
OPERATOR
MINIMUM 5AMPERE SERVICE
PER OPERATOR
GREEN
BLACK
BLUE
BLUE
ON
ONEWAY
REDUCEDOPEN
HOLD OPEN
FULLOPEN
O N L Y A U T O
D O O R O PE RA T IO N
RED
BLACK
RED
RED
O F F
NIGHT
BLUE
BACK SIDE OF
SWITCHSHOWN.
BLACK
WHITE
WHITE
RED ROCKER SWITCH
EXTENSIONHARNESS
PT. 229186
MOTORHARNESS AND PLUGS
PLUG FOR HANDY TERMINAL

Sliders Electrical Manual
NABCO
ENTRANCES INC www.nabcoentrances.com - 2 -
Table of Contents
Electrical Information Page 3
Typical Slider Wiring Page 4
Microprocessor Controller Page 5-6
Dual Operator Wiring Diagrams Page 7
Acusensor/Acumotion Page 8
How Door Function Modes are Achieved via the Rocker Switches Page 9
Holding Beams (Activation—Hold Open) Page 10
Holding Beam (Breakout—Power Interrupt) Page 11
Diagram for connecting push plates and or card readers for Night mode. Page 12
Electric Locks—Fail Safe Page 13
Electric Locks—Fail Secure Page 14
Troubleshooting Page 15-17

Sliders Electrical Manual
NABCO
ENTRANCES INC www.nabcoentrances.com - 3 -
Electrical Information
Note: Since the Model 1175 Slider is predominantly wired at the factory the site installer/electrician has a
relatively simple task.
1. Convenient electric service access
holes have been provided in the slide
header end caps and jamb tubes. An
installer/electrician should route 120
VAC, single phase, 5 AMP
(MINIMUM) power to the factory sup-
plied and mounted junction box in the
header.
2. The installer/electrician should connect one power
hot lead (Black) to the power cut off switch
mounted inside the junction box. Utilizing an ap-
propriate wire nut, the installer/electrician should
connect the common lead (White) to the loose
common lead (White) found inside the junction
box. The ground wire should be connected to the
ground screw located in the back of the switch
junction box.
3. Replace the junction box cover. The
unit’s power should now be activated
through the building’s electrical circuit
breaker box. Proceed with performance
set-up procedures outlined in the Mi-
croprocessor and Handy Terminal
Manual p/n 159000
WARNING
Disconnect all power to the junction box prior to making any electrical connections.
Wiring must meet all local, state, federal or other governing agency codes. Failure to
do so may result in serious personal or fatal injury.
Factory Wiring
Ground
Hot
Common
DN 0006

Sliders Electrical Manual
NABCO
ENTRANCES INC www.nabcoentrances.com - 4 -
Typical Slider Wiring
Wiring diagrams are included in the back of this manual, which reflect the typical primary and secondary
circuits installed at the factory. The low voltage (12 VDC) Reed switch (panic break away) and Acusensor
are easily connected on site using factory installed connector housings. The factory uses Underwriters
Laboratories’ (UL) recognized component wire, terminals and connector housings to manufacture the
slider. Contact the Customer Service Department for assistance with special applications.
WARNING
Microprocessor controller contains HIGH VOLTAGE! Installation should be performed by
qualified personnel only. Wiring must meet all local, state, federal or other governing agency
codes. Failure to do so may result in serious personal or fatal injury.
General Wiring Diagram
BACK SIDE OF
SWITCH SHOWN.
SW. EXT.
HARNESS
PT. NO.
22-9220
SW. EXT.
HARNESS
PT. NO.
22-9220
WHITE
WHITE
PLUG WITH
BLUE JUMPER
MUST BE IN
PLACE
PN 120324
HOLDING BEAM
CONNECTOR. USE
ONLY WITH
HOLDING BEAMS!
ACUSENSOR
EXTENSION
HARNESS
PT. NO.
22-9267
RED
Yel
Gray Gray
Yel
RED
ACUSENSOR
EXTENSION
HARNESS
PT. NO.
22-9267
RED
ACUSENSOR HARNESS
PT. NO. 229184
BLACK
GREEN WHITE
EXTERIOR ACUSENSOR
PT. NO. 148902
MAGNETIC POWER
DOWN SWITCH PT.
NO. 229222
MAGNETIC POWER
DOWN SWITCH PT.
NO. 229222
HANDING HARNESS
PT. NO. 11-9208
RIGHT HAND UNITS ONLY
MTR.
HARNESS
& PLUG
Microprocessor Controller
PT. NO. 24-8901
PN 219821-01
2110097 Telescopic Operator
219528 1175 Slider Operator
Telescopic units only.
Second pulley for
PLUG FOR HANDY TERMINAL
U16 and later models.
New Switch
BROWN
ORANGE
RED
GREEN
BROWN +12 VDC
PT. 229186
EXTENSION HARNESS
ROCKER SWITCH
BLACK
GREEN
RED
WHITE
BLUE
WHITE
PT. NO. 148902
INTERIOR ACUSENSOR
WHITE
GREEN
BLACK
PT. NO. 229184
ACUSENSOR HARNESS
GREEN
RED
WHITE
BLUE
RED
RED
BLUE
BLUE
Red
White
White
Black
Red
Blue
Red
Green
Red
OPEN
FULL
HOLD OPEN
ONE WAY
TWO WAY
NIGHT
OFF
REDUCED OPEN
ON
Green
Black
White
Black
Blue
Red
BLACK
GREEN
WHITE
RED
BLUE
WIRE NUT
WIRE NUT
PER OPERATOR
MINIMUM 5 AMPERE SERVICE
USED FOR ELECTRIC LOCK
USED FOR ELECTRIC LOCK
USED FOR SEQUENTIAL OPERATION
WHITE
OPERATOR
MOTOR
ORANGE 62
YELLOW
GRAY
VIOLET
Handy Terminal Connector (6 pin)
Motor Connector (6 pin)
PowerConnector (4 pin)
Size: 5.2 x20mm
Rating:125V, 5A
Fuse Inside
No.
COLORSYMBOLNO.
12
11
10
9
8
7
6
5
4
3
2
1
OUT -
OUT +
BA
SQ
62
M1
M0
H
6B
61
7
9DC12V
Gray
Violet
Blue
Yellow
Orange
Orange
Orange
Green
White
Black
Red
Brown
COLORNO.
6
5
4
3
2
1
Yellow
Black
Blue
Brown
Orange
Red USE
EncoderB Phase
EncoderGround
Motor UPhase
EncoderA Phase
Encoder12 VDC
Motor VPhase
USECOLORNO.
4
3
2
1
Black
White
Not Used
115VAC Hot
115VAC Common
Not Used
WARNING
type andrating.
with afuse of the same
againstfire, replace only
For continued protection
CAUTION
WIRE NUT
WIRE NUT
SWITCH BOX
ORANGE M1
ORANGE M0
GREEN
RED
BROWN
BLACK
BLUE
WHITE
GREEN
WHITE
BLACK
BLACK
SERVICE GROUND
120 VAC "COMMON"
120 VAC "HOT"
BLACK
DN 0001
WHITE
WHITE
OFF
NIGHT
RED
RED
BLUE
BLACK
RED
RED
BLACK
DOOR OPERATION AUTO
ONLY
FULL OPEN
HOLD OPEN
REDUCED OPEN
BLACK
GREEN
WHITE
RED
ONE WAY
ON
BLUE
SWITCH SHOWN.
BACK SIDE OF
U16 and earlier models.
Old Switch

Sliders Electrical Manual
NABCO
ENTRANCES INC www.nabcoentrances.com - 5 -
By alternately switching the two MO & M1 (orange wires) on the microprocessor harness to RED (common) the various door modes such as
HOLD OPEN mode, EXIT mode, NIGHT mode etc. are achieved. (Off = not switched to commonOn = switched to common)
Blue (BA) wire must remain tied to Red (Common) for door to function.
Refer to Page 9 for more information
Internal
1 Amp
Relay
DN0010
All voltages
shown measured
with respect to
Red (Common)
Auxiliary
Output
(this switch
acts like a
door
sequencer)
Sequential
Wall Switch
Holding Beams
N.O. contacts
Exterior Sensor
N.O. contacts Interior Sensor
N.O. contacts
12 VDC @ no Activation
0 VDC @ Activation
12 VDC @ no Activation
0 VDC @ Activation
12 VDC @ no Activation
0 VDC @ Activation
Red
(Common)
ON/OFF
Rocker Switch
Panic
Breakout / Stop
Circuit
Logic
Circuit
Logic
Circuit
Reduced
Opening
Panic Breakout Switch
(normally closed contacts)
0 VDC if Panic Circuit Closed and Rocker Switch Turned "ON"
12 VDC if Panic Circuit Open or Rocker Switch Turned "OFF"
+12 VDC
Slider Schematic Wiring Diagram - U04 and Higher Microprocessor
Blue
Nabco "U" Series Microprocessor
Rocker Switch Bank
Orange (M0)
Orange (M1)
Red (7)
Violet (out+)
Yellow(SQ)
Gray(out-)
Green (H)
Blue (BA)
Black (61)
Brown (9DC12V)
White (6B)
Orange (62)
Panic Breakout Switch
(normally closed contacts)
Panic Breakout Switch
(normally closed contacts)
PN 249801
Microprocessor Controller

Sliders Electrical Manual
NABCO
ENTRANCES INC www.nabcoentrances.com - 6 -
Microprocessor Controller
The Microprocessor controller has been designed to control the numerous operating characteristics of the
slide door system including speed, recycling and door opening width. It will need to be programmed after
the installation is complete. (See the Microprocessor Manual p/n 159000 for more details).
CAUTION:
Read and understand the Microprocessor Manual p/n 159000 before attempting to
power-up the door. Failure to do so may result in damage to the door and/or injury to
the installer and will nullify all warranties.
Microprocessor Main
Harness Diagram
Black
Yellow
Blue
Purple
Grey
Orange M1
Brown
Red
Black
Orange MO
Green
White White
Black
Blue
Green
Orange MO
Orange M1
Red
Brown
CN4
Red
Red
Green
Brown
Red
Rocker
Switch
Connector
Blue
Blue
Black
Green
Blue
White
Red
Motor Plug
CN2
M.C.
CN1
Red
Green
Red
Blue
Red
ON
REDUCED OPE N
OFF
NIGHT
TWO WAY
ONE WAY
HOLDOPEN
Red
Black
White
WhiteBlack
FULL
OPEN
Red
Blue
Green
Black
White
Holding Beam Connector
Red
Blue
Breakaway
Connectors
Blue
Red
Blue
Interior Accusensor
Connector
White
White
White
White
White
White
White
Black
Ground
White
120 VAC
HOLD OPEN
FULL
Black
Black
Red
Green
Red
White
Blue
Red Red
AUTO
NIGHT
ON Blue
DOOR OPERATION
ONLY
OFF
RE DUCED OPEN
White
ONE WAY
Main Breaker
Switch
in Header
DN 0002
CN3
Handy
Terminal
Connector
Red
Brown
Orange
Orange
Yellow
Green Blue
White
Red
Yellow
Black
Blue
Orange 62
Rocker Switch Extension Harness
PN 229186
Rocker Switches (Old)
U16 and earliermodels.
Backside of both
switches shown. Rocker Switches (New)
U16 and latermodels.
PN 219821-01
NOTE: In some cases the interior
and exterior Accusensors are reversed
Exterior
Accusensor
Connector
Blue
Red
White
Green
Black

Sliders Electrical Manual
NABCO
ENTRANCES INC www.nabcoentrances.com - 7 -
NOT USED
NOT USED
HARNESS FOR SLIDER
SIMULTANEOUS PAIR
P/N: 215901
ROCKER SWITCHES
P/N: 219821-01
CAUTI O N
USE [ SLI DER/ SWI NG ER]
For cont inued pr ot ect ion
against f ire, r eplace only
wit h sam e t ype and r at ing
of f us e.
W ARNI NG
1
2
3
4
CO LO R
WHI TE
BLACK
NO . USE
EM PTY
115VAC HO T
EM PTY
1
2
3
4
5
6
O RANG E
RED
BRO W N
YELLO W
CO LO RNO . USE
115VAC CO M M O N
M O TO R V PHASE
ENCO DER A PHASE
M O TO R U PHASE
ENCO DER G ND
ENCO DER B PHASE
1
2
3
4
7
61
6B
NO .
9DC12V CO LO RSYM BO L
BRO W N
RED
BLACK
WHI TE
12VDC +
12VDC - , CO M M O N
APPRO ACH
5 H G REEN
6
7
8
9
10
11
12
M 0
M 1
62
BA
O UT +
O UT -
O RANG E
O RANG E
O RANG E
YELLO W
BLUE
VI O LET
G RAY
SQ
O UTPUT -
O UTPUT +
SEQ UENTI AL
APPRO ACH(THRO UG H)
REDUCED O PENI NG
/ SAFETY M AT
THRESHO LD SENSI NG
/ PRESENCE SENSO R
M O DE SW 1
M O DE SW 2
BREAK O UT
BLUE
BLACK
GYROTECH- 248901.10
PO WER SO URCE ( 4 P)
O PERATO R ( 6P) FUSE I NSI DE
RATI NG : 125V, 4A
SI ZE:5. 2 x 20m m
HANDY TERM I NAL ( 6P)
SENSO R ( 12 P)
1. Please adjust t his oper at or as per inst r uct ion m anual.
2. Tur n t he power of f , bef or e opening t he box.
3. Don't open t his box ex cept f or r eplacing f use.
O t her wise , t he war r ant y will b e t er m inat ed .
4. Repair of t his unit except by Nabco Ent r anc es, I nc.
m ay caus e so f t war e and ha r dwar e m alf unct ion.
CAUTI O N
USE [ SLI DER/ SWI NG ER]
For cont inued pr ot ect ion
against f ire, r eplace only
wit h sam e t ype and r at ing
of f us e.
W ARNI NG
1
2
3
4
CO LO R
WHI TE
BLACK
NO . USE
EM PTY
115VAC HO T
EM PTY
1
2
3
4
5
6
O RANG E
RED
BRO W N
YELLO W
CO LO RNO . USE
115VAC CO M M O N
M O TO R V PHASE
ENCO DER 12VDC
ENCO DER A PHASE
M O TO R U PHASE
ENCO DER G ND
ENCO DER B PHASE
1
2
3
4
7
61
6B
NO .
9DC12V CO LO RSYM BO L
BRO W N
RED
BLACK
WHI TE
12VDC +
12VDC - , CO M M O N
APPRO ACH
5 H G REEN
6
7
8
9
10
11
12
M 0
M 1
62
BA
O UT +
O UT -
O RANG E
O RANG E
O RANG E
YELLO W
BLUE
VI O LET
G RAY
SQ
O UTPUT -
O UTPUT +
SEQ UENTI AL
APPRO ACH(THRO UG H)
REDUCED O PENI NG
/ SAFETY M AT
THRESHO LD SENSI NG
/ PRESENCE SENSO R
M O DE SW 1
M O DE SW 2
BREAK O UT
BLUE
BLACK
GYROTECH- 248901.10
PO WER SO URCE ( 4 P)
O PERATO R ( 6P) FUSE I NSI DE
RATI NG : 125V, 4A
SI ZE:5. 2 x 20m m
HANDY TERM I NAL ( 6P)
SENSO R ( 12 P)
1. Please adjust t his oper at or as per inst r uct ion m anual.
2. Tur n t he power of f , bef or e opening t he box.
3. Don't open t his box ex cept f or r eplacing f use.
O t her wise , t he war r ant y will b e t er m inat ed .
4. Repair of t his unit except by Nabco Ent r anc es, I nc.
m ay caus e so f t war e and ha r dwar e m alf unct ion.
A
B
Black(61)
White(6B)
Green(H)
Orange(M0)
Orange(M1)
Orange(62)
Blue(BA)
Red(7)
Violet(OUT+)
Brown(9DC12V)
Gray(OUT-)
Yellow(SQ)
Black(61)
White(6B)
Green(H)
Orange(M0)
Orange(M1)
Orange(62)
Blue(BA)
Red(7)
Violet(OUT+)
Brown(9DC12V)
Gray(OUT-)
Yellow(SQ)
RED
BROWN
BROWN
RED
GREEN
ORANGE(62)
RED
WHITE
RED
RED
WHITE
RED
RED
RED
BROWN
BROWN
BLACK
RED
BROWN
BROWN
RED
GREEN
ORANGE(62)
LABEL B
LABEL B
LABEL A
C
1 2 43
21 21
1 2 4
1 2 43
21
21
D
2
2
BLUE
BLUE
BLUE
BLUE
BLUE
RED
RED
1
1
24 135
24 135
21
21
21
21
GREEN
GREEN
ORANGE(M1)
ORANGE(M0)
BLUE
BLUE
Breakout Switch
B side door
4/1/2004
RED
RED
BROWN
BROWN
BLACK
BLUE
BLUE
BLUE
BLUE
LABEL A
24 135
2 1
2 1
24135
1 2 4
21
21
21
21
BLUE
BLUE
GREEN
GREEN
ORANGE(M1)
O N
REDUCED O PEN
O FF
NIG HT
TWO WA Y
O NE WAY
HO LD O PEN
FULL
OPEN
DUAL OPERATORWIRINGDIAGRAM
DN0071
Breakout Switch
A side door
MICROPROCESSOR CONTROLLER (MC)
(with special harness) P/N: 248901
Plug both Breakout Switches
#229222into MCHarness
#218901 at DReceptacle
of Harness #215901.
Ifthis is not followed,
Breakout will not function
properly.
ORANGE(M0)
BLUE
RED
RED
ACUSENSOR
(INTERIORSIDE)
ACUSENSOR
(EXTERIORSIDE)
ACUSENSOR
(INTERIORSIDE)
ACUSENSOR
(EXTERIOR SIDE)
A doorstop is neededat the
center of the headerto stop
thedoors independently.
ENCO DER 12VDC
PlugRockerSwitch#219821-01
into MCHarness #218901
at CReceptacle of #215901
harness.
Ifthis is not followed ,
Breakout will not function
and the Breakout Switches
#229183mayweld shut
and needtobereplaced.
Breakout Switch
Harness Extension
229220-00
MICROPROCESSOR CONTROLLER (MC)
(with special harness) P/N: 248901
JUMPER PLUG FOR
SIMULTANEOUS PAIR
P/N: 119826
Dual Operator Wiring Diagram

Sliders Electrical Manual
NABCO
ENTRANCES INC www.nabcoentrances.com - 8 -
ACUSENSOR/ACUMOTION
The header is wired from the factory so that the activation circuitry on the exterior sensor is turned off in
One Way Traffic Mode (the safety circuitry remains active and can not be turned off). The exterior sensor
is located on the side of the header in the direction of panic or panel breakout. This can easily be reversed
in the field by swapping the connectors where each sensor plugs into the main harness.
1
2
3
4
Red
Yellow
Red
Red
Black
White
Green
Black
White
Green
1
2
3
4
1
2
3
4
Acusensor Harness (#229184)
1
2
3
4
1
2
3
4
Acusensor Harness (#229184)
Red
Black
White
Green
Green
White
Black
Red
Brown
Gray
Gray
1
2
3
4
Yellow
Yellow
4
3
2
11
2
3
4
Red
Yellow
Gray
Acusensor Extension Harness
(#229267-01 48" Long)
(#229267-02 24" Long)
4
3
2
11
2
3
4
Red
Yellow
Gray
Acusensor Extension Harness
(#229267-01 48" Long)
(#229267-02 24" Long)
4
3
2
1
4
3
2
1
Brown
Orange
Green
Red
Brown
Red
Black
or
Main Harness
4
3
2
1
4
3
2
1
Main Harness
Brown
Orange
Green
Red
Brown
Red
Black
or
DN 0003
Exterior
Sensor
Interior
Sensor
Exterior
Sensor
Interior
Sensor
Acusensor
PN 148902
Acumotion
1410364

Sliders Electrical Manual
NABCO
ENTRANCES INC www.nabcoentrances.com - 9 -
OFF OFF Auto Mode. Both sensor signals are available Electric Lock is always unlocked.
OFF ON Night Mode. None of the sensor signals will be accepted. Sensors will provide threshold safety and electric
lock is always locked. Activation must occur by means of an exterior activation device such as a card reader or
key switch.
ON ON Hold Open Mode. The door keeps the full open point, not affected by sensors. Electric Lock is always
unlocked.
ON OFF One Way Traffic. The interior sensor activates the door; the exterior sensor provides threshold safety. Electric
Lock is locked until an interior activation is received
MODE SWITCH TABLE
MO M1 Mode
OFF OFF Automatic Mode
OFF ON Night Mode
ON ON Hold Open Mode
ON OFF One Way Mode
The table at right summarizes
the functions as outlined above:
MO M1 Results
How Door Function Modes are Achieved via the Rocker Switches
By alternately switching the two MO & M1 (orange wires) on the microprocessor harness to RED (common) the various door
modes such as HOLD OPEN mode, EXIT mode, NIGHT mode etc. are achieved. Refer to the tables below.
(Off = not switched to common On = switched to common)

Sliders Electrical Manual
NABCO
ENTRANCES INC www.nabcoentrances.com - 10
Holding Beams (Activation—Hold Open)
The Holding Beam is a factory-installed unit consisting of an emitter, detector and control box. They are
flush mounted in door frames and/or jamb tubes, facing each other along the threshold. A pulsed, infrared
light beam is continuously transmitted across the door opening. Interruption of the beam will switch the
White holding beam input wire to Red (Common). This will cause the system to re-activate and hold open
until the interruption is cleared.
13 Yellow
12 Gray
11 Yellow
10 Gray
9 Yellow
8 Blue
7 Yellow
6 Blue
Brown
Green
Blue
Red
Blue
Brown
Black
Blue
Green
Red
White
Red
Orange
Yellow
Jacket color
Connect
Each Terminal
the Same
Braided
Shield
Plastic Conductor
Optex Controller and One
RCVR & One TRANS
PT. NO. 149710-01
EMTR 1
Gray
Blue
RCVR 2
RCVR 1
Blue
EMTR 2
Gray
Brown
Red
Optex OS-10C
Controller
Red
Term # & Color
Not
used
Exterior
Motion
Sensor
Interior
Motion
Sensor
Panic
Breakout
Switch or
Plug with
Blue Jumper
connects
here.
Panic
Breakout
Switch or
Plug with
Blue Jumper
connects
here.
Panic
Breakout
Switch or
Plug with
Blue Jumper
connects
here.
PN 15-10288
DN 0004
Terminal #6
Terminal #1
Terminal #13
Terminal #5
Optex OA-10C Beams on a GT-1175
Wiring Diagram for Holding Beams
(U04 and Higher)

Sliders Electrical Manual
NABCO
ENTRANCES INC www.nabcoentrances.com - 11
Holding Beam (Breakout—Power Interrupt)
The Holding Beam is a factory-installed unit consisting of an emitter, detector and control box. They are
flush mounted in door frames and/or jamb tubes, facing each other. A pulsed, infrared light beam is
continuously transmitted across the door opening. Interruption of the beam by breaking out a door panel
will interrupt the blue wire power down loop. This will cause the system to stop operating until the door
panel is repositioned and latched.
Term # & Color
Panic
Breakout
Switch or
Plug with
Blue Jumper
connects
here.
Holding
Beams Panic
Breakout
Switch or
Plug with
Blue Jumper
connects
here.
Interior
Motion
Sensor
Exterior
Motion
Sensor
Optex Controller and One
RCVR & One TRANS
PT. NO. 149710-01
PN 15-10287
DN 0005
Terminal #5Terminal #1
Terminal #13Terminal #6
Optex OA-10C Beams on a GT-1175
Wiring Diagram for Breakout Beams
(U04 and Higher)
Plastic Conductor Shield
Braided
the Same
Each Terminal
Connect
Jacket color Yellow
13 Yellow
12 Gray
11 Yellow
10 Gray
9 Yellow
8 Blue
7 Yellow
6 Blue
Gray
EMTR 1
Optex OS-10C
Controller
Blue
RCVR 1
Red Jumper
Orange
Red
Red Brown
White
Red
Green
Blue
Black
Black
Blue
Brown
PT. NO. 1110187
Hold Beam Pigtail
Blue Red
Blue
Green
Brown

Sliders Electrical Manual
NABCO
ENTRANCES INC www.nabcoentrances.com - 12
Diagram for connecting push plates and or card readers for Night mode.
Attach the normally open contacts across the red and black wire on either the rocker or key
switches.
HOLDOPEN
FULL
Black
Black
Red
Green
Red
White
Blue
Red Red
AUTO
NIGHT
ON
DO OR OPERATION
ONLY
O FF
REDUCEDOPEN
White
ONE WAY
Blue
Blue
Green
OrangeMO
OrangeM1
Red
Blue
White
Green
White
Green
White
Green
Rocker
Switch
Connector
Blue
Blue
Blue
Red
Blue
Black
Black
Red
Green
White
Blue
Red
Green
Red
Blue
Red
ON
REDUCED OPEN
OFF
NIGHT
TWO WAY
ONE WAY
HOLDOPEN
Red
Black
White
WhiteBlack
FULL
OPEN
Red
Blue
Green
Black
White
RE DUCED
Red
White
Black
Green
Blue
Push buttomswitch
duringnightmode.
Red(#1)
White(#6)
Black(#2)
Red(#8)
Green(#1)
Blue(#4)
Pushbuttomswitch
duringnightmode.
Push buttomswitch
duringnightmode.
DN0007
OLDROCKERSWITCH
U16andearliermodels. NEWROCKERSWITCH
U16andlatermodels.
PN219821-01
KEYSWITCH
PN219820
H.O.NIGHT
FULL STOP
AUTOEXIT
Closing
contacts
with door
in NIGHT
mode
opens
door.
Breakaway
Connectors
Backsideofswitch.
1175Microprocessor WireDiagram
Activationwith Nightmode.
Connectcardreader andwall plate
normallyopendrycontactsasshown.
Accessintheheader.
Backsideofswitch.

Sliders Electrical Manual
NABCO
ENTRANCES INC www.nabcoentrances.com - 13
MOV
101576
RELAY(DC12V)
229240
RECTIFIER
119929-01
AC24V
TRANSFORMER
(GRN)
AC115V (YEL) (BLK/WHT)
ELECTRIC LOCK/ STRIKE
Fail
Safe
Type
(BLK/WHT)
ON
OPEN>>> CLOSE
CLOSED
LOCKED UNLOCKED(ON)
ACTIVATE
SIGNAL
DOOR
OUTPUT
SIGNAL
timedelay(0.25~1sec)timedelay(0.25~1sec)
CLOSED
LOCKED
Handy Terminal : Aux. Output [0] , time delay [0]~[3]
Mode Input : One Way Traffic Mode or Night Mode
(OR)
(OR)
OUT+
(VIOLET)
OUT-
(GRAY)
7(RED)
Wire Nut
103125
No.
MICROPROCESSOR CONTROLLER
GYRO TECH - 248901
HANDYTERMINAL(6P)
SENSOR(12P)
1.Pleaseadjustthis operatoras per instructionmanual.
2.Turnthepoweroff, beforeopeningthebox.
3.Don'topenthis boxexcept forreplacingfuse.
Otherwise, thewarrantywill be terminated.
4.RepairofthisunitexceptbyLansonIndustries,Inc.
maycausesoftwareandhardwaremalfunction.
USE
USE
C A U T I O N
USE [SLIDER/SWINGER]
For continued protection
against fire, replace only
with same type and rating
of fuse.
WARNING
FUSE INSIDE
RATING:125V,4A
SIZE:5.2x20mm
GYRO TECH
LANSON INDUSTRIES INC.
E N T R A N C E S
COLOR
BROWN
RED
BLACK
WHITE
GREEN
ORANGE
ORANGE
ORANGE
YELLOW
BLUE
VIOLET
GRAY
7
61
6B
9DC12V
SYMBOL
H
M0
M1
62
BA
OUT +
OUT -
SQ
1
2
3
4
NO.
5
6
7
8
9
10
11
12
POWERSOURCE(4P)
OPERATOR(6P)
EMPTY
115VAC HOT
EMPTY
115VAC COMMONWHITE
BLACK
1
2
3
4
COLORNO.
MOTOR V PHASE
ENCODER 12VDC
ENCODER A PHASE
MOTOR U PHASE
ENCODER GND
ENCODER B PHASE
ORANGE
RED
BROWN
YELLOW
COLOR
BLUE
BLACK
1
2
3
4
5
6
NO.
DN 0008
KITPN2110471-02
NOTE: LOCK WORKS
ONLY INNIGHT
& EXITMODES
BROWN
143197-05
VIOLET
101649
9DC12V
(BROWN)
1 2 3 4 5 6 7 8 9
Electric Locks—Fail Safe

Sliders Electrical Manual
NABCO
ENTRANCES INC www.nabcoentrances.com - 14
WireNut
103125 RELAY(DC12V)
229240
MOV
101576
BROWN
143197-05
VIOLET 101649
(GRN)
(OR)
(OR)
AC24V
TRANSFORMER
AC115V
RECTIFIER
119929-01
KIT PN 2110471-01
NOTE: LOCK WORKS
ONLY IN NIGHT
& EXIT MODES
No.
MICROPROCESSOR CONTROLLER
GYRO TECH - 248901
HANDYTERMINAL(6P)
SENSOR(12P)
1.Pleaseadjust this operator as per instruction manual.
2.Turnthepower off,beforeopeningthebox.
3.Don't open this box except for replacingfuse.
Otherwise, the warranty will beterminated.
4.Repair of this unit exceptby LansonIndustries,Inc.
maycausesoftwareandhardwaremalfunction.
USE
USE
C A U T IO N
USE [SLIDER/SWINGER]
For continued protection
against fire, replace only
with same type and rating
of fuse.
WARNING
FUSE INSIDE
RATING:125V,4A
SIZE:5.2x20mm
GYROTECH
LANSON INDUSTRIES INC.
E N T R A N C E S
COLOR
BROWN
RED
BLACK
WHITE
GREEN
ORANGE
ORANGE
ORANGE
YELLOW
BLUE
VIOLET
GRAY
7
61
6B
9DC12V
SYMBOL
H
M0
M1
62
BA
OUT +
OUT -
SQ
1
2
3
4
NO.
5
6
7
8
9
10
11
12
POWERSOURCE(4P)
OPERATOR(6P)
EMPTY
115VAC HOT
EMPTY
115VAC COMMONWHITE
BLACK
1
2
3
4
COLORNO.
MOTOR V PHASE
ENCODER 12VDC
ENCODER A PHASE
MOTOR U PHASE
ENCODER GND
ENCODER B PHASE
ORANGE
RED
BROWN
YELLOW
COLOR
BLUE
BLACK
1
2
3
4
5
6
NO. OUT+
(VIOLET)
OUT-
(GRAY)
7(RED)
DN 0009
9DC12V
(BROWN)
(YEL)
WireNut
103125
Fail
Secure
Type
(BLK/
WHT)
(BLK/
WHT)
ELECTRIC LOCK/STRIKE
ON
OPEN>>>CLOSE
CLOSED
LOCKED UNLOCKED(ON)
ACTIVATE
SIGNAL
DOOR
OUTPUT
SIGNAL
timedelay(0.25~1sec)timedelay(0.25~1sec)
CLOSED
LOCKED
Handy Terminal : Aux. Output [0] , time delay [0]~[3]
Mode Input : One Way Traffic Mode or Night Mode
123456789
Electric Locks—Fail Secure

Sliders Electrical Manual
NABCO
ENTRANCES INC www.nabcoentrances.com - 15
Part No.
1110431
BDrawing No.
PART NAME:
MATERIAL:
SPECIFICATIONS:
SHEET #:
1 OF 1
DATE:
SCALE:
DRAWN BY:
APP. BY:
4-21-03
Jc
MB
None
TOLERANCES
(UNLESSNOTED)
FRACTIONAL______± 1
64
X _____________± .030
XX ____________± .015
XXX ___________± .005
ANGLE ___________± 1
2°
Distributor Test Harness Kit
ITEM QTY PART NO. DESCRIPTION
11104261 1 Door Position Harness for Magnum Control
11104282 1 Test Harness for GT 1100
3 1 1110427 Test Harness for GT 300/400/500 Analog Control
ERN 894 REVISIONS DATE
6-11-03
ANALOG CONTROL
TEST HARNESS FOR GT 300/400/500
LABEL:
TEST HARNESS FOR GT 1100
LABEL:
CONTROL
GT 300/400/500/710 MAGNUM
DOOR POSTION TEST HARNESS FOR
LABEL:
1234
8
7
6
5
Panic Switch Bypass Plug
121032426 Microprocessor Switch Jumper Plug
1
5 119826 Microprocessor Test Plug
14 1110429
Instruction Set for Distributor Test Harness Kit18 1510430 Microprocessor Jumper Plug
17 115941
DN0070
May 2003
Part # 15-10430
Test Kit Manual
Harness Kit
Distributor Test
Instruction Set for
Techn ical Assista nce: 866- 622-832 5
Fax: 8 88-6 79-3 319
Ph one : 877- 622-2 694
Mus keg o, W I 531 50
P.O. Bo x 90 6
S8 2 W187 17 Ge mini Drive
NAB CO EN TRAN C ES INC.
TEST PLUG
MICROPROCESSOR
LABEL:
JUMPER PLUG
MICROPROCESSOR
LABEL:
BYPASS PLUG
PANIC SWITCH
LABEL:
SWITCH JUMPER PLUG
MICROPROCESSOR
LABEL:
Trouble Shooting

Sliders Electrical Manual
NABCO
ENTRANCES INC www.nabcoentrances.com - 16
Troubleshooting
1. Acusensor does not seem to reach out far enough
a) Move the area lever on the side of the Acusensor to a higher number.
b) Increase the opening speed on the door with the Handy Terminal.
c) If desired, replace Acusensor with Acumotion for greater detection range.
2. Acusensor is not seeing people accessing the door from the side.
a) Turn on more of the area switches on the front of the Acusensor.
b) Door is set to One Way Traffic mode and sensor is switched out. Set door to Auto mode.
3. When the doors are panicked open, the system does not shut down.
a) Check the wiring of the power down switch in the fixed panel or bottom of header. (Full Open
Units.) Blue (BA) circuit must go open for system to shut down.
b) Check the wiring of the breakout beam circuit. (Surface Applied Units.) Blue (BA) circuit must go
open for system to shut down.
4. Doors do not move when power is applied or Handy Terminal connected.
a) Confirm the swing panel is closed completely.
b) Confirm Blue (BA) circuit is not open. Zero VDC between Red and Blue on microprocessor har-
ness for correct operation. If 12VDC circuit is open.
b) Check the power down magnet in the top rail of the swing panel is installed and aligned with the
magnetic power down switch in the bottom of the header.
c) Confirm rocker is switch is set to ON not OFF.
5. The cover on the Acusensor will not snap on.
a) Install thin washers to space the Acusensor off from the header and provide clearance for the cover.
6. Doors move very slowly when the Handy Terminal is connected. (Only happens after “Stroke Cycle”
initiated.)
a) This is normal. It is “learning” the door stroke.
b) After learning the stroke, the Handy Terminal will prompt you with options
7. The doors do not open completely.
a) Look for obstructions in the track as well as inside the header. Check to make sure that the belt
clips are not hitting something.
b) On Full Open units be sure that the interlock clips are adjusted properly.
c) Check for any racking in the door.
b) Check that the mode switch on the panel is not in “Reduced Opening” mode.
c) Use the Handy Terminal and reinitialize the system.
8. I want to eliminate all outside switches and sensors and test the system with the Handy Terminal.
a) Disconnect the 12-pin connector from inside the microprocessor and install the special connector
jumper tool p/n 115941 into its place.
b) The system will consist of only the motor, operator and control box (Microprocessor). The Handy
Terminal will be the only means of operating the door.

Sliders Electrical Manual
NABCO
ENTRANCES INC www.nabcoentrances.com - 17
Troubleshooting
9. I want to reset the system back to the factory settings.
a) Plug in Hand Terminal and wait for the door to close.
b) At “Swing/Slide/Stroke?” enter YES.
c) At “Swing Door Y or N?” enter YES (even though you have a slide door).
d) Door will try to initialize as a swing door and reset the settings.
e) At “Swing/Slide/Stroke?” enter YES.
f) At “Swing Door Y or N?” enter NO.
g) The system will now initialize as a slide door to the factory settings.
h) You must set the door stroke from the Handy Terminal from the prompts at this point.
10. Door does not run unless holding beam is interrupted.
a) The holding beam connector (it has a red and white wire in it) in the main harness may be inadver-
tently plugged into one of the “Power Down” (blue wires) plugs. Any vacant “Power Down” plugs
should have a blue jumper installed.
For technical assistance call: 866-622-8325
or engineering at: 877-622-2694
Table of contents
Popular Intercom System manuals by other brands

Vimar
Vimar ELVOX 6200 instruction sheet

Cardo Systems
Cardo Systems G9 Powerset Pairing Guides

urmet domus
urmet domus 1060/601 installer and user manual

Longix
Longix LE-VIM44 Operation and installation manual

CyberData
CyberData 011530 Installation quick reference

LAON TECHNOLOGY
LAON TECHNOLOGY LT550 EXPERT quick reference