PRODUCT INSTRUCTIONS
LIMIT SWITCHES
WWW.NAMCOCONTROLS.COM | PH 800.390.6405
NAM1819 REV A.
WIRING AND MOUNTING
Unless specifically designed for such service, limit switches SHOULD NOT BE submerged in or
splashed with oils, coolants or other liquids. CONSULT FACTORY. In order to maintain a NEMA type 4
rating, a UL type 4 rated connector must be used. If a connector less than a type 4 rated is used, the
system enclosure rating will become the rating of the connector.
Limit switches MUST NOT BE used in locations where temperature or atmospheric conditions are
beyond those for which they have been specifically designed. Power from dierent sources MUST
NOT BE connected to the contact of one limit switch unless specifically designed for such service. The
temperature rating of the field installed conductors must be at least 90°C.
Limit switches MUST BE used within their contact ratings. Refer to switch label on cover for electrical
ratings and the appropriate limit switch bulletin for acceptable environmental conditions in which the
switch has been designed to function properly.
Limit switches SHOULD BE mounted rigidly and in readily accessible locations, with suitable
clearances to permit easy service and replacement when necessary. Cover plates SHOULD face the
maintenance access point. Refer to Figure B for terminal connections.
Limit switches SHOULD BE placed in locations where machining chips do not accumulate under
normal operating conditions to avoid chip interference with a lever operation.
Opposite polarities MUST NOT BE connected to the contacts of one limit switch unless the limit switch
is specifically designed for such service. See Figure B for terminal markings for field wire type–copper.
The terminal tightening torque shall be 20-25 in./Ibs.
ACTUATOR CONSIDERATION
Where relatively slow motions operate the limit switch, a snap-acting or snap-lock design SHOULD
BE used.
Where relatively fast motions are involved, cam arrangement SHOULD BE such that the actuator does
not receive a severe impact.
Where relatively fast motions are involved, cams MUST BE designed such that the limit switch will be
held operated long enough to operate relays, valves, etc. See Figure A.
Limit switches MUST NOT BE operated beyond the manufacturer’s recommended travel. Operating
positions and lever travel terminology are illustrated in drawing below. For specifications of a specific
switch, refer to the switch datasheet.
NOTE: When loosening or tightening the pipe plug or set screw used to clamp the actuating lever in
the desired position, care must be exercised to restrain the shaft/lever assembly so as not to transmit
the applied torque to the switch itself.
Cam or dog arrangements SHOULD BE such that the actuator is not suddenly released to snap back
freely unless specifically designed for such service.
For limit switches with lever actuators, the actuating force SHOULD BE applied asnearlyperpendicular
to the lever as practical and perpendicular to the shaft axis in which the lever rotates.
A limit switch actuator MUST BE allowed to move far enough for positive operation of the contacts.
LimitswitchesMUSTBEmountedinlocations whichwillpreventfalseoperationbynormalmovements
of operator or machine components.
Limit switches are designed for proper performance with the actuators with which they are supplied.
Supplementary actuators SHOULD NOT BE used unless the limit switches are specifically designed
for them.
Operating mechanisms for limit switches MUST BE so designed that, under any operating or
emergency conditions, the limit switch is not operated beyond its overtravel limit position. A limit
switch MUST NOT BE used as a mechanical stop.
WARNING:
A SWITCH IN A PROTECTIVE INTERLOCKING CIRCUIT SHOULD BE USED WITH AT LEAST ONE
OTHER DEVICE THAT WILL PROVIDE A REDUNDANT PROTECTIVE FUNCTION, AND THE CIRCUIT
SHOULD BE SO ARRANGED THAT EITHER DEVICE WILL INTERRUPT INTENDED OPERATION OF THE
CONTROLLED EQUIPMENT. (PROPOSED NEMA ICS 2-225.95 St’d.)
SERVICING ENERGIZED INDUSTRIAL CONTROL EQUIPMENT CAN BE HAZARDOUS. SEVERE
INJURY OR DEATH CAN RESULT FROM ELECTRICAL SHOCK, BURN OR UNINTENDED ACTUATION
OFCONTROLLED EQUIPMENT.
RECOMMENDED PRACTICE IS TO DISCONNECT AND LOCK OUT CONTROL EQUIPMENT FROM
POWER SOURCES, AND DISCHARGE STORED ENERGY IN CAPACITORS, IF PRESENT. IF IT IS
NECESSARY TO WORK IN THE VICINITY OF ENERGIZED EQUIPMENT, ONLY QUALIFIED PERSONNEL
SHOULD BE PERMITTED TO PERFORM SUCH WORK , USING ALL APPLICABLE SAFETY PRACTICES
AND PROTECTIVE EQUIPMENT.
EXPERIENCE HAS SHOWN THAT THE MECHANICAL AND ELECTRICAL OPERATING LIFE OF A LIMIT SWITCH
IS INFLUENCED TO A LARGE DEGREE BY PROPER INSTALLATION AND APPLICATION PROCEDURES. THIS
PUBLICATION IS INTENDED TO BE USED AS A GUIDE.
The user should refer to NFPA 70B, RECOMMENDED PRACTICE FOR ELECTRICAL MAINTENANCE,
published by the National Fire Protection Association, for additional information.
PRODUCT INSTRUCTIONS
LIMIT SWITCHES
WWW.NAMCOCONTROLS.COM | PH 800.390.6405
NAM1819 REV A.
FIGURE A FIGURE B
*For limit switches without ground terminal, mount switch body to metal frame for grounding.

Other NAMCO Switch manuals

NAMCO EA530 Series Instruction sheet

NAMCO

NAMCO EA530 Series Instruction sheet

Popular Switch manuals by other brands

Allmatic ARGO 1 Series manual

Allmatic

Allmatic ARGO 1 Series manual

ENFORCER MVS-AH31-01NQ manual

ENFORCER

ENFORCER MVS-AH31-01NQ manual

Key Digital Champion KD-2X1CS operating instructions

Key Digital

Key Digital Champion KD-2X1CS operating instructions

Cyclades AlterPath KVM 16 manual

Cyclades

Cyclades AlterPath KVM 16 manual

Cisco AS-2000 Configuration guide

Cisco

Cisco AS-2000 Configuration guide

VICOR DC MegaPAC user guide

VICOR

VICOR DC MegaPAC user guide

Talkswitch switch Start guide

Talkswitch

Talkswitch switch Start guide

ABB OTM_C_21D Installation and operating instructions

ABB

ABB OTM_C_21D Installation and operating instructions

Larson Electronics EPS-PB10-GRN-2XC instruction manual

Larson Electronics

Larson Electronics EPS-PB10-GRN-2XC instruction manual

INSTEON Hub quick start guide

INSTEON

INSTEON Hub quick start guide

ZyXEL Communications SHD2110 quick start guide

ZyXEL Communications

ZyXEL Communications SHD2110 quick start guide

Westermo Lynx SERIES user guide

Westermo

Westermo Lynx SERIES user guide

PINC Technology PT-WS-V0-T-1-PB0-TY manual

PINC Technology

PINC Technology PT-WS-V0-T-1-PB0-TY manual

Kontron CP6924 user guide

Kontron

Kontron CP6924 user guide

Lantech IES-3208C user manual

Lantech

Lantech IES-3208C user manual

Gianni Industries GEM CP-21-GE specification

Gianni Industries

Gianni Industries GEM CP-21-GE specification

Allied Telesis SBx8112 Command reference

Allied Telesis

Allied Telesis SBx8112 Command reference

Cypress CPCD-3A Operation manual

Cypress

Cypress CPCD-3A Operation manual

manuals.online logo
manuals.online logoBrands
  • About & Mission
  • Contact us
  • Privacy Policy
  • Terms and Conditions

Copyright 2025 Manuals.Online. All Rights Reserved.