1/4" Torque Range ................................30 N-m / 22.12 ft-lb
3/8" Torque Range ................................135 N-m / 99.5 ft-lb
1/2" Torque Range ...............................340 N-m / 250.7 ft-lb
Accuracy (*1) ...............................(CW°G±3%) (CCW°G±4%)
Accuracy (*2) ...................+/- 2° ( rotating 90° at speed of 30°/sec)
Data Memory Values ........................................... 50
Number of Presets ...............................................9
Operation Modes ....................................Peak Hold/Track
Unit Selection ...........................N-m, ft-lb, in-lb, kg-cm, degree
Audible Alarm ................................................. Yes
Buttons........................................................5
LED Indicator .............................................12 LED's
Batteries ...................................................2 AAA
Battery Life-Continuous Operation (*3) ...........................24 Hrs
Battery Life-Standby (*3) ......................................1 Year
Operating Temperature ..................................-10ºF ~ 60ºF
Storage Temperature ....................................-20ºF ~ 70ºF
Humidity ..................................Up to 90% non-condensing
SPECIFICATIONS
AlwAys reAd
instructions
before using
tools
AlwAys weAr
sAfety
goggles
not
wAterproof
DATA12, DATA14, DATA38
1/4", 3/8", 1/2" Dr. Digital Angle Torque Adaptor
WARNING

DATA12, DATA14, DATA38 2 Rev. 02/15/12
This insTrucTion Manual conTains iMporTanT safeTy inforMaTion.
read This insTrucTion Manual carefully and undersTand all inforMaTion Before
operaTing This Tool.
• Alwayswearimpact-resistanteyeandfaceprotectionwhenoperatingor
performingmaintenanceonthistool.
• Keepthetoolinefficientoperatingcondition.
• Keepbodyworkingstancebalancedandfirm.Donotoverreachwhen
operatingthetool.
• Donotforcetoolbeyonditsratedcapacity.
• Donotremoveanylabels.Replacedamagedlabels.
• Communicationsportisforusebyauthorizedservice
centertechniciansonly.
FAILURE TO OBSERVE THESE WARNINGS COULD RESULT IN INJURY
WARNING - FOLLOW THESE RULES FOR SAFE OPERATION!
WARRANTY
SPECIFICATIONS
Notes from Page 1:
*1: The accuracy of the readout is guaranteed from 20%
to 100% of maximum range + /- 1 increment. For
maintaining accuracy, calibrate the adaptor at regular
intervals (1 year recommended).
*2: The angle accuracy is guaranteed at ±2° when
rotating adaptor to 90° at speed of 30°/sec.
*3: Use two AAA batteries. (Test condition: Toshiba
carbon-zincbattery)
*4: Horizontalandverticaltest
*5: One cycle means turning the torque adaptor from
0 N-m to maximum torque and back to 0 N-m.
*6: Environmental test:
a.Dryheat
b. Cold
c.Dampheat
d.Changeoftemperature
e.Impact(shock)
f. Vibration
g. Drop
*7: Electromagnetic compatibility test:
a. Electrostaticdischargeimmunity(ESD)
b. Radiation susceptibility
DIGITAL TORQUE WRENCH - LIMITED 12-MONTH WARRANTY
Carlyle Professional Hand Tools warrants to the original purchaser that the company’s digital torque wrenches
are free from defects in material or workmanship during the one year warranty period. We will repair any digital
torquewrenchwhichfailstogivesatisfactoryserviceduetodefectiveworkmanshipormaterials(excludingcalibration)for
12months fromthedateoforiginalpurchase.(Calibrationisonlycoveredbythiswarrantyforeachnewunusedtorque
wrenchoutofbox.)Productsmustbereturnedwithproofofpurchase,freightprepaid,tothewarrantyservicecenterlisted
below.
This warranty excludes torque wrenches which have been subjected to abnormal use, accident, neglect, or lack of
maintenance. Any modification, disassembly of this wrench or repair by an unauthorized service center will void the
warranty.
Thiswarrantygivesyouspecificrights.Youmayalsohaveotherrightswhichvaryfromstatetostate.
TheforegoingobligationisCarlyleProfessionalHandToolssoleliabilityunderthisoranyimpliedwarrantyandunderno
circumstancesshallCarlyleProfessionalHandToolsbeliableforanyincidentalorconsequentialdamages.
Note:Somestatesdonotallowtheexclusionorlimitationofincidentalorconsequentialdamagessotheabovelimitation
orexclusionmaynotapplytoyou.
For Warranty Service and Recalibration/Certification Services, contact:
Torque Wrench Repair Facility
315HawkinsRd.
Travelers Rest, SC 29690
Phone:866.496.8423•Fax:864.834.6651

DATA12, DATA14, DATA38 3 Rev. 02/15/12
FEATURES AND FUNCTIONS
BATTERY INSTALLATION
• Loosenthescrewofthebattery cover.
• InserttwoAAAbatteriesmatchingthe-/+polaritiesofthe
batterytothebatterycompartment.
• Fastenthescrewofthebatterycover.
BEFORE USING THE DIGITAL ANGLE TORQUE ADAPTOR
1. LED Indicator
2.Buzzer
3. LCD Readout
4. Torque/Angle Value
5. Units
6. Peak/Track Mode
7. Memory Number
8.PowerOn/ClearButton
9. Unit/Setting Button
10. Per-setting Button
11.Up/DownButton
12. Communication Port
(
Authorizedservicecenteruseonly)
13. Extension Bar
14. Battery Cover
Torque zero-reset
Press
Current target torque
N-m
M T
Current target angle
N-m
M
Press
8
910
11
REPLACEMENT PARTS AVAILABLE AS:
RSDATABC Battery Cap
RSDATA14CS BlowMoldCase for DATA14
Nootherinternalpartsareavailableduetothe
sensitivityofthisprofessionalmodel.Pleaseutilizethe
repairfacilitylistedunderthewarrantystatementforall
repairsinandoutofwarranty.
3 4 5
6
7
1
2
13
12
14
+
+
_
_
RSDATA38CS BlowMoldCase for DATA38
RSDATA12CS BlowMoldCase for DATA12

DATA12, DATA14, DATA38 4 Rev. 02/15/12
AUTO POWER OFF
ZERO RESET
POWER ON AND AUTO ZERO RESET
• Attachtheadaptoronthetool.
• Gentlypresstopoweron.
• Autozero-resetwillbeprocessedfirst.
• Theadaptorwillbestartedintorqueoranglemode.
Whichmodewillbestarteddependsoninwhich
modetheadaptorispowered-offlasttime.
• Intorquemode,atargettorquescreenwillbeshown.
• Inanglemode,afterseveralsecondsofanglezero-
reset,aanglescreenwillbeshown(Seezeroreset
sectiononthismanual.)
• Ifittakestoolonginanglereset,presstoreset
again.
ATTENTION:
1. If appears, refer to “ERROR MESSAGE”.
2. IMPORTANT!
• During angle reset, keep the adaptor still
and do not shake, vibrate or even
touching the adaptor.
• Themeterwillpowerdownafter2minutes,
enteringapowersavingsmode.
• Pressforzeroreset.
• Presstozeroresetthedigitalangletorque
adaptorbeforeuse.Thiswillensurebetteraccuracy.
• Inanglemode,attachthemetertothehandratchet
thatyouplantotorquewith.Turnonandletitzeroout
before use.
• Intorquemode,ifanexternalforceisappliedtothe
torqueadaptorduringzero-resetperiod,aninitial
torqueoffseterrorwilloccur.
• Iftheadaptorismovingagainandagain,the
zeroresetwillnotstop.
Finally, willbeshown.
(Refer to “ERROR MESSAGE”)
Press

DATA12, DATA14, DATA38 5 Rev. 02/15/12
HARDWARE TEST
• Todoahardwarereset,removethebatteryand
re-install it.
• Iftheadaptordoesnotfunctionnormallyor
appears,pleasegothroughtheresetprocessto
restarttheadaptor.
LOW VOLTAGE INDICATOR
Ifthebatteryvoltageistoolow,themeterwilldisplaya
batterysymbolandthenturnoff.Replacebatteries.
Er0
When showsduringpower-onprocess,
itmeansthisadaptorhasbeenappliedtomorethan
110% of maximum torque.
Er4
Inanglemode,iftheadaptordoesnotreset
successfully for a period of time, willbe
shown.Presstodozero-resetagainandplacethe
adaptor on a flat surface to reset.
SETTING TORQUE VALUES
RESETTING PRESET VALUES
• Press topoweron.
•Do not apply force on adaptor.
• Targettorqueoranglewillbeshown.
• Press toselectthetorqueunitordegree
(anglemode)andthenpress to set
target value.
• Toselectpresetvaluespressthebutton
repeatedly until desired preset is selected.
• Press to reset adaptor.(suggested)
• Start to rotate adaptor.
• WatchoutthewarningLED,soundsandLCDto
stop rotation.
Tracking Mode
• Intrackmode,LCDdisplaysthecurrenttorque
value.
• Afterreleaseforce,theLCDvaluewillreturnto0.
Peak Mode
• Inpearkmode,LCDdisplaysthemaximumtorque
value attained.
• Afterreleaseofforce,theLCDshowsthe
maximumvaluethatcanbereached.(flashing)
N-m
M T
indicator
• Nowpress to record maximum torque value, or
press
to clear it.
Angle operation
• Inanglemode,LCDdisplaystheanglerotatedafter
thereachingover5%oftheratedmaximumtorque.
• Nowpress to record angle value, or press
to clear it.
Er5
showsthattheadaptordoesnot
workfunctionally,pleasedohardware
reset. Refer to “HARDWARE RESET”.
Er--
Inanglemode,iftheadaptorrotatestoofast,
willbeshown.Presstozeroresettheadaptor.

DATA12, DATA14, DATA38 6 Rev. 02/15/12
SETUP
• Press topowerontheadaptor.
• Press toselectthetorqueunit(torque mode)
or “ ° ” (angle mode)
• Thenpress to set target value.
• Notethatthetargetvaluewill be saved
automaticallywiththecurrentMnumber
disregarding torque or angle.
WITHOUT APPLYING
FORCE
TARGET TORQUE
OR ANGLE
N-m
M T
M
N-m
M T
In.lb.
M T
ft.lb.
M T
kg.cm
M T
M
N.m
In.lb
Ft.lb
Kg.cm
º (Angle)
N-m
M T
N-m
M T
N-m
M T
M
M
M
OR
N-m
M T
N-m
M T M T
EX. Select units
EX. Set targets
EX. Using the pre-set targets
STEP 1: INSTALL THE ADAPTOR AND POWER ON
STEP 2: DO NOT APPLY FORCES ON ADAPTOR
STEP 4: SET TARGET TORQUE OR ANGLE
STEP 3: TARGET TORQUE FOR ANGLE WILL BE
SHOWN

DATA12, DATA14, DATA38 7 Rev. 02/15/12
• Press tozero-resettheadaptor.(suggested)
• Refer to “POWER ON AND AUTO ZERO
RESET” and “ZERO RESET”.
• Refer to “P/T MODE SELECTION” to set Por
T- mode operation of torque.
Definition
T-mode torque view
1. In T-mode, if a force is applied on adaptor, LCD
displaysandtracksthecurrenttorquevalue.
2. Afterreleasingforce,theLCDvaluewillreturn
totargetsettingview.
P-mode torque view
1. InP-mode,LCDdisplaysthemaximumtorque
value.
2. Afterreleasingforce,theLCDshowsthe
catchedmaximumvalue.(flashing)
• Rotatetheadaptorclockwiseor
counter-clockwise.
Note:Theadapterworksinbothdirection
clockwiseandcounterclockwise.
STEP 5: ZERO- RESET ADAPTOR
STEP 7: START TO ROTATE ADAPTOR
STEP 6: CHECK P/T MODE OF TORQUE
(Torque Only)
Press
N-m
M T
N-m
M P
N-m
M T
N-m
M P

DATA12, DATA14, DATA38 8 Rev. 02/15/12
• Thereare12LEDstoindicatethecurrenttorque
oranglereaching80%,85%,90%,95%,97.5%
(green LED indication) and 100% (red LED
indication) of target torque/angle.
• Thereisalsoabuzzertoindicatethereaching
level of target value. Interval sound means it
reachesover80%andlongsoundmeansit
reachesover100%oftargetvalue.
Track mode Torque value
• In Track mode, if a force is applied on adaptor,
LCDdisplaysandtracksthecurrenttorque
value.
• Afterreleasingforce,theLCDvaluewillreturnto
targetsettingview.
Peak mode Torque value
• InPeakmode,LCDdisplaysthemaximum
torque value.
• Afterreleasingforce,theLCDshowsthe
maximumvalue.(flashing)
STEP 8: WHAT TO LOOK FOR
STEP 9: TORQUE/ANGLE VALUE WHEN ROTATES
100% 97.5% 95% 90% 85% 80%
((...((... ...))...)) over 80%
((((((((... ...)))))))) over 100%
N-m
T
Apply
13.5 Nm
Current torque value
Release
force
Target torque
N-m
M T
N-m
P
N-m
P
Apply
13.5 Nm
12.0 Nm
Current torque value
Release
force
N-m
P
N-m
P
24.48 Nm

DATA12, DATA14, DATA38 9 Rev. 02/15/12
Angle value
• Inanglemode,theLCDdisplaystheangle
rotated.Theangleiscountedaftertherotation
torquehasbeenreachingover5%oftherated
maximum torque.
• Afterreleasingforce,theLCDshowsthe
maximumangleandthemaximumtorque.
(alternatively)
No
force
EX. For a 30.00Nm adaptor, 5% is 1.5Nm
Target angle
M
1.5 Nm
Continuously
applying
force
Release
force
Start to count angle
N-m
Peak mode
• InP-mode,afterreleasingforce,theLCDshows
themaximumvalue.(flashing)
• Press toclearthemaximumtorqueandthat
willreturntothetargettorque.
• Press to recordthemaximumtorqueand,
thenitwillclearandgobacktoshowthetarget
torque.
Angle-mode
• Inanglemode,afterreleasingforce,theLCD
showsthemaximumangleandthemaximum
torque (alternatively).
• Press toclearthemaximumangleandgo
backtoshowthetargetangle.
• Pressing willrecordthemaximumangle,then
clearitandgobacktoshowthetargetangle.
STEP 10: SAVE TORQUE/ANGLE VALUE OR CLEAR
MAXIMUM VALUE
STEP 11: BACK TO STEP FOR NEXT OPERATION
Maximum torque Target torque
N-m
P
N-m
M P
Target torque
Show rec (record) and Its number
N-m
M P
Maximum angle and torque (alternatively)
Target angle
N-m
P
Target angle
Show rec (record) and Its number
M
M
M

DATA12, DATA14, DATA38 10 Rev. 02/15/12
VISIT SETUP MENU
• Fromthetargettorque/anglescreen,pressandhold
to go into setup menu. Continuously press to
visittheP/Tmodemenu,torque-unit-in-angle-
operation menu, record menu, record clear-all
menu, operation count menu and communication
menu. Finally press againtoskipoutthesetup
menuandgobacktothetargettorque/angle
screen.
N-m
M T
N-m
N-m
T
Long
Press
P/T mode menu
Torque-unit-in-angle-operation menu
Record menu
Record clear-all menu
Operation count menu
Communication menu
M

DATA12, DATA14, DATA38 11 Rev. 02/15/12
P/T MODE SELECTION
SELECT TORQUE UNIT IN ANGLE OPERATION
• VisittheP/T mode menu, press or to select
thePeak-holdorTrack mode of torque operation.
• Continuouslypressingwillskipsetupmenu
andgobacktothetargettorque/anglescreen.
• Visitthetorque-unit-in-angle-operation menu,
pressortoselectthetorqueunitduringangle
rotation.
• Continuouslypressingwillskipoutthesetup
menuandgobacktothetargettorque/angle
screen.
T
T
OR
OR
OR
OR
N-m
N-m
In.lb.
ft.lb.
OR
kg.cm

DATA12, DATA14, DATA38 12 Rev. 02/15/12
VIEW DATA RECORD
CLEAR A SINGLE RECORD
• Visittherecord menu,pressortoselectthe
datanumberandviewit.
• Ifnorecordexists, willbeshown.
• Continuouslypressingwillskipoutthesetup
menuandgobacktothetargettorque/angle
screen.
• Visittherecord menu.
• Pressortoselectthedatanumberyou
wanttodelete.
• Presstwicetodeletethecurrentdata.(
willbeshown)
• Ifpressonce,willbeshown.Ifyou
wanttoabandonthisaction,justpresstoskip
thismenu.
• Continuouslypressingwillskipoutthesetup
menuandgobacktothetargettorque/angle
screen.
Press or to select data
Press or to select data
Abandon

DATA12, DATA14, DATA38 13 Rev. 02/15/12
CLEAR ALL RECORDS
VIEW OPERATION COUNTS
• Visittherecord clear-all menu.
• Presstwicetodeletetheallrecorddata.(
willbeshown)
• Ifpressonce, willbeshown.Ifyou
wanttoabandon,justpresstoskipthismenu.
• Continuouslypressingwillskipthesetup
menuandgobacktothetargettorque/angle
screen.
• Visittheoperation counts,theoperationcounts
willbeshown.
• Operationcountingrecordcountseverytimethe
adaptorhasbeenusedover60%ofmaximum
torque.Thisrecordisnoterasableuntil
re-calibration.
• Thefeaturewillcountupto65,000measurements.
• Thefollowingfiguremeanstherecordedcountis
10025.
• Continuouslypressingwillskipthesetupmenu
andgobacktothetargettorque/anglescreen.
Abandon

DATA12, DATA14, DATA38 14 Rev. 02/15/12
MAINTENANCE AND STORAGE
BATTERY MAINTANCE
ATTENTION:
One-year periodic recalibration is necessary to
maintain accuracy.
Please contact your local dealer for calibration.
CAUTION
1. Over-torque (110% of Max. torque range)
could cause breakage or lose accuracy.
2. Donotshakeviolentlyordropwrench.
3. Donotusethiswrenchasahammer.
4. Donotleavethiswrenchinanyplace
exposedtoexcessiveheat,humidity,ordirect
sunlight.
5. Donotusethisapparatusinwater.(not
waterproof)
6. Ifthewrenchgetswet,wipeitwithadry
towelassoonaspossible.Thesaltin
seawatercanbeespeciallydamaging.
7. Donotuseorganicsolvents,suchasalcohol
orpaintthinnerwhencleaningthewrench.
8. Keepthiswrenchawayfrommagnets.
9. Donotexposethiswrenchtodustorsandas
thiscouldcauseseriousdamage.
10. DonotapplyexcessiveforcetotheLCD
panel.
11.Applytorqueslowlyandgraspthecenterof
thehandle.Donotapplyloadtotheendof
handle.
1.Whenthewrenchisnotusedforanextendedperiod
oftime,removethebattery.
2.Keepasparebatteryonhandwhengoingonalong
trip or to cold areas.
3. Do not mix battery types or combine used batteries
withnewones.
4.Sweat,oilandwatercanpreventabattery’sterminal
frommakingelectricalcontact.Toavoidthis,wipe
bothterminalsbeforeloadingabattery.
Dispose of batteries in a designated disposal area. Do
notthrowbatteriesintoafire.

DATA12, DATA14, DATA38 15 Rev. 02/15/12
TROUBLESHOOTING
Error Codes for Angle Feature Torque Wrenches
Error Code Cause Corrective Action Comments
1. Pressthebuttonto restart
thetorquewrench-Ifthisdoesnot
work,then
2. Remove battery cap - then
reinstall.Pressthebuttonto
restartthetorquewrench.
1. Pressthebuttonto restart
thetorquewrench-Ifthisdoesnot
work,then
2. Remove battery cap - then
reinstall.Pressthebuttonto
restartthetorquewrench.
1. Pressthebuttonto restart
thetorquewrench-Ifthisdoesnot
work,then
2. Remove battery cap - then
reinstall.Pressthebuttonto
restartthetorquewrench.
Applied torque exceeded 110% of
themaximumratedcapacityofthe
torquewrench.
Returntorquewrenchtorepaircenter
for calibration.
Thetorquewrenchshutdown
duringanglemode.When
restarted,thetorquewrenchwas
notlayinghorizontally.
Angle module communication
failure.
Rotationalspeedofthetorque
wrenchwasexceeded.
Note 1.
Ifthetorquewrenchisshutdownwhileinanglemode,thenrestartedwhilenothorizontal,fourflashingzeros
mayappearinthedisplay.FollowthesamestepslistedaboveforER4errorcode.
Seealso"AngleModeWarning"onpage4ofthemanualtoreviewcorrectproceduresfor
changingtheanglevalues.
Ifthetorquewrenchis
in angle mode, it must
belayinginthe
horizontalposition
whenturnedon.
Ifthetorquewrench
does not restart or
continuestoshowthe
ER5 error code, it
shouldsenttothe
repair center.
Rotational speed of
thetorquewrench
shouldnotexceed30º
per second.
(See note 1.)

DATA12, DATA14, DATA38 16 Rev. 02/15/12
NOTES
Memory Prest
Location #
Newton meters
(N-m)
inch/pounds
(in - lb)
foot/pounds
(ft - lb)
kilogram/centimeters
(kg -cm)
angle
(degree º)
1
2
3
4
5
6
7
8
9

DATA12, DATA14, DATA38 17 Rev. 02/15/12
DATA12, DATA14, DATA38
Rango de torsión 1/4" .........................30 N-m / 22.12 libras-pie
Rango de torsión 3/8" ..........................135 N-m/99.5 libras-pie
Rango de torsión 1/2" .........................340 N-m/250.7 libras-pie
Precisión (*1)................................(CW°G±3%) (CCW°G±4%)
Precisión (*2)...............+/- 2° (girando 90° a una velocidad de 30°/seg.)
Valores de la memoria de los datos................................ 50
Númerodepre-ajuste ............................................9
Modos de operación ........................Retención de picos/Rastreo
Unit Selection ...........................N-m, ft-lb, in-lb, kg-cm, degree
Alarma audible ..................................................Sí
Botones .......................................................5
Indicador DEL ..................................... 12 lámparas DEL
Baterías ...................................................2 AAA
Operación de vida continua de la batería (*2) ....................24horas
Vida de la batería - de reserva (*3)................................1 año
Temperatura de operación ................................-10ºF ~ 60ºF
Temperatura de almacenamiento...........................-20ºF ~ 70ºF
Humedad .......................... Dehastaun90%sincondensación
ESPECIFICACIONES
DATA12, DATA14, DATA38
Adaptador digital de torsión de ángulo Encaje 1/4", 3/8", 1/2"
sieMpre
leA lAs
instrucciones
Antes de
usAr lAs
HerrAMientAs
sieMpre lleVe
puesto gogles
de seguridAd
no
iMperMeAble
ADVERTENCIA

DATA12, DATA14, DATA38 18 Rev. 02/15/12
esTe Manual insTrucTiVo conTiene inforMacÓn iMporTanTe de seguridad.
lea esTe Manual insTrucTiVo cuidadosaMenTe y coMprenda Toda la inforMaciÓn anTes
de operar esTa herraMienTa.
• Siemprellevepuestoproteccióndeojosydelacararesistentealimpacto
durantelaoperaciónomantenimientodeestaherramienta.
• Mantengalaherramientaencondicioneseficientesdeoperación.
• Mantengasuposturadetrabajobalanceadayfirme.Noseextra-limiteal
momentodeoperarlaherramienta.
• Nofuercelaherramientamásalládesucapacidadnominal.
• Noquiteningunaherramienta.Repongalasetiquetasdañadas.
• Elpuertodecomunicacionesessóloparausoportécnicosdecentrosde
servicioautorizados
HACER CASO OMISO A ESTAS ADVERTENCIAS PODRÍA OCASIONAR LESIONES
ADVERTENCIA - ¡SIGA LAS REGLAS PARA UNA OPERACIÓN SEGURA!
GARANTÍA
ESPECIFICACIONES
TORQUÍMETRO DIGITAL - GARANTÍA LIMITADA DE 12 MESES
CarlyleProfessionalHandToolslegarantizaalcompradororiginalquelostorquímetrosdigitalesdelacompañíasonlibres
de defectos en cuanto al material y mano de obra durante el periodo de garantía de un año. Repararemos cualquier
torquímetro digital el cual falla en brindar un servicio satisfactorio debido a mano de obra o materiales defectuosos por 12
mesesapartirdelafechadecompraoriginal.(Elcalibradosóloestácubiertobajoestagarantíaparacadatorquímetro
nuevonousadofueradecaja).Losproductosdebenserdevueltosconlacomprobacióndecompra,fleteprepagado,al
centro de servicio de garantía alistado a continuación.
Estagarantíaexcluyelostorquímetrosloscualeshayansidosujetadosalusoanormal,accidentes,lanegligencia,olafalta
de mantenimiento. Se anulará la garantía por cualquier modificación, el desensamble de este torquímetro o reparaciones
porpartedeuncentrodeservicionoautorizado.
Estagarantíalebrindaderechosespecíficos.Ustedpuedecontarconderechosadicionalesloscualesvaríandeestadoa
estado.
LaobligaciónanterioreslaúnicaresponsabilidadporpartedeCarlyleProfessionalHandToolsbajoéstaocualquierotra
garantía implicada y bajo ninguna circunstancia será responsable Carlyle Professional Hand Tools por ningún daño
incidental ni consecuencial.
Nota: Algunos estados no permiten la exclusión ni limitación de daños incidentales ni consecuenciales por lo que la
limitación o exclusión anterior puede no ser aplicable para usted.
Para servicio de garantía y servicios de recalibrado/certificación, comuníquese con:
Torque Wrench Repair Facility
315HawkinsRd.
Travelers Rest, SC 29690
Phone:866.496.8423•Fax:864.834.6651
Notas de las página 1:
*1:Laprecisióndelalecturaestágarantizadadesde20%
al 100% de rango máximo + /- un (1) incremento. Para
mantener la precisión, calibre el adaptador a intervalos
regulares (1 año recomendado).
*2: Laprecisióndelánguloestágarantizadaa±2°cuando
segiraeladaptadorhastalos90°aunavelocidadde
30°/seg.
*3: Use dos baterías AAA. (Condición de prueba: Batería
decarbono-cincdeToshiba)
*4: Pruebahorizontalyvertical
*5: Un ciclo implica girar el adaptador de torsión desde
0N-mhastalamáximatorsiónydenuevoa0N-m.
*6: Prueba medioambiental:
a. Calor seco
b. Frío
c.Calorhúmedo
d. Cambio de temperatura
e.Impacto(choque)
f. Vibraciones
g. Caída
*7:Pruebadecompatibilidadelectromagnética:
a. Inmunidad de descarga electrostática (ESD)
b. Susceptibilidad a la radiación
c. Emisión de radiación

DATA12, DATA14, DATA38 19 Rev. 02/15/12
CARACTERÍSTICAS Y FUNCIONES
INSTALACIÓN DE LA BATERÍA
• Aflojeeltornillodelatapadelabatería.
• InsertedosbateríasAAAemparejandolaspolaridades-/+dela
batería al compartimiento de la batería.
• Sujeteeltornillodelatapadebatería.
ANTES DE USAR EL ADAPTADOR DIGITAL DE TORSIÓN DE ÁNGULO
1. Lámparas indicadoras DEL
2. Alarma/timbre
3. Lectura de salida DCL
4. Torsión/Valor de ángulo
5. Unidades
6.Modo de pico/rastreo
7. Número de memoria
8.Botón de encendido/borrado
9.Botóndeunidad/ajuste
10.Botóndepre-ajustado
11. Botónhaciaarriba/Botón
haciaabajo
12. Puerto de comunicación
(Uso porcentrosdeservicioautorizados
solamente)
13. Barra de extensión
14. Tapa de batería
Cero-reajuste del
esfuerzo de torsión
Presione
Torsión meta actual
N-m
M T
Torsión meta actual
N-m
M
Presione
LAS PARTES DE REPUESTO DISPONIBLES COMO:
RSDATABC Tapa de batería
RSDATA14CS Estuchemoldeadp
por soplado para DATA14
Ninguna otra parte está disponible debido a la sensibilidad de
este modelo profesional. Utilice por favor el centro de
reparaciónalistadobajoladeclaracióndegarantíaparatodas
las reparaciones dentro y fuera de garantía.
8
910
11
3 4 5
6
7
1
2
13
12
14
+
+
_
_
RSDATA38CS Estuchemoldeadp
por soplado para DATA38
RSDATA12CS Estuchemoldeadp
por soplado para DATA12

DATA12, DATA14, DATA38 20 Rev. 02/15/12
APAGADO AUTOMÁTICO
REAJUSTE A CERO
CERO-REAJUSTE DEL ESFUERZO DE TORSIÓN
• Sujeteeladaptadorenlaherramienta.
• Presionesuavementeparaencender.
• Autoreajusteaceroseráprocesadoprimero.
• Eladaptadoriniciaráenelmododetorsióno
de ángulo. El modo el cual se iniciará depende
del modo en cual el adaptador fue apagado la
últimavez.
• Enelmododetorsión,semostraráunapantalla
de torsión meta.
• Enelmododeángulo,despuésdevarios
segundosdereajustedelánguloencero,se
mostrará una pantalla de ángulo (Ver la sección
dereajusteaceroenestemanual.)
• Sisetardademasiadoenelreajustedel
ángulo,presioneparareajustardenuevo.
ATENCIÓN:
1. Si aparece, consulte el “MENSAJE
DE ERROR”.
2. IMPORTANTE!
• Durante el reajuste del ángulo, mantenga
el adaptador sin moverse y no agite, vibre
ni toque el adaptador.
• Elcalibradorseapagarádespuésde2minutos,
asíentrandoalmododeahorrodepotencia.
• Presioneparareajusteacero.
• Presioneparareajustaraceroeladaptadordigital
de torsión de ángulo antes del uso. Esto asegurará una
mejorprecisión.
• Enelmododeángulo,sujeteelcalibradoraltrinquete
demanoconelcualsepretenderealizareltrabajode
torsión.Préndaloydejequesereajusteaceroantes
del uso.
• Enelmododetorsión,siunafuerzaexternaseaplica
aladaptadordetorsiónduranteelperiododereajuste
a cero, se ocurrirá un error de descompensación inicial
de torsión.
• Sieladaptadorestámoviéndoseunayotravez,el
reajusteaceronoparará.
Finalmente, se mostrará.
(Consulte el “MENSAJE DE ERROR”)
Presione
This manual suits for next models