manuals.online logo
Brands
  1. Home
  2. •
  3. Brands
  4. •
  5. NAPCO
  6. •
  7. Recording Equipment
  8. •
  9. NAPCO CA3000 - BROCHURE 1 User manual

NAPCO CA3000 - BROCHURE 1 User manual

This manual suits for next models

1

Other NAPCO Recording Equipment manuals

NAPCO ISEE-IVR-250 - User manual

NAPCO

NAPCO ISEE-IVR-250 - User manual

NAPCO PCI2000 User manual

NAPCO

NAPCO PCI2000 User manual

NAPCO ISEE-IVR-250 - User manual

NAPCO

NAPCO ISEE-IVR-250 - User manual

Popular Recording Equipment manuals by other brands

ThermoFisher Scientific Dionex DRS 600 Installation checklist

ThermoFisher Scientific

ThermoFisher Scientific Dionex DRS 600 Installation checklist

Shure ANIUSB-Matrix user guide

Shure

Shure ANIUSB-Matrix user guide

Nady Audio HE-1 user guide

Nady Audio

Nady Audio HE-1 user guide

AUDAC APM 01 User manual & installation guide

AUDAC

AUDAC APM 01 User manual & installation guide

Teac GF-350 owner's manual

Teac

Teac GF-350 owner's manual

Fractal Audio MFC-101 MARK III owner's manual

Fractal Audio

Fractal Audio MFC-101 MARK III owner's manual

bmcm USB-OI16 manual

bmcm

bmcm USB-OI16 manual

HHB BurnIT CDR-830 Service manual

HHB

HHB BurnIT CDR-830 Service manual

GE VersaMax IC200CPUE05 manual

GE

GE VersaMax IC200CPUE05 manual

IntesisBox MH-RC-MBS-1 user manual

IntesisBox

IntesisBox MH-RC-MBS-1 user manual

Attero Tech unD4l user manual

Attero Tech

Attero Tech unD4l user manual

Sennheiser UI 765 instruction manual

Sennheiser

Sennheiser UI 765 instruction manual

Sony RCD-W1 Operating Instructions  (primary... Service manual

Sony

Sony RCD-W1 Operating Instructions (primary... Service manual

Roland Planet-P  MKS-10 owner's manual

Roland

Roland Planet-P MKS-10 owner's manual

Roland BOSS GT-PRO Turbostart

Roland

Roland BOSS GT-PRO Turbostart

8x8 Inc Valcom V-2001A manual

8x8 Inc

8x8 Inc Valcom V-2001A manual

Waves SUB Align user guide

Waves

Waves SUB Align user guide

Mitsubishi Electric MAC-334IF-E installation manual

Mitsubishi Electric

Mitsubishi Electric MAC-334IF-E installation manual

manuals.online logo
manuals.online logoBrands
  • About & Mission
  • Contact us
  • Privacy Policy
  • Terms and Conditions

Copyright 2025 Manuals.Online. All Rights Reserved.

NAPCO Integration
CA3NAPX Gemini Alarm Panel Interface
The Continental Access/NAPCO Integration
solution provides seamless integration with
the CardAccess® CA3000 V2.0 & higher
software and the NAPCO Gemini Series
of alarm panels. By combining the power of the
Continental’s CA3000 Access Control System and
the NAPCO 32 to 255 zone Gemini GEM-P3200,
GEM-P9600 or GEM-X255 Alarm Panels, the user
can combine all of their alarm events into one,
easy-to-use, CardAccess Graphical User Interface
(GUI).
Events
With this interface, NAPCO alarms are routed,
by priority, directly to the CA3000 Event/Pending
Alert screen in real time. This gives onsite security
offices more direct, immediate alarm reporting on
one centralized user interface. This capability can
allow faster dispatch on alarm, to pinpointed loca-
tions, by internal or external security patrols/staff.
The CA3000 can also send email or pager notifica-
tion of the alert.**
Arming & Disarming
The Continental/NAPCO Integration provides the
user the ability to program a CA3000 cardholder,
or cardholders, to arm or disarm a Napco alarm
area/areas. Any of the access control reader tech-
nologies (biometric, proximity, magstripe, etc..)
available to the CA3000 system can be utilized to
perform this function. There is also a built-in man-
ual control interface for arming or disarming with a
click of the mouse. The CA3000 can notify the user
at the reader level whether a Napco area is ready
for arming, armed or disarmed.**
Communication
By replacing the Napco Panel firmware (CA3NAPX),
you have several choices of communications pro-
tocol between the Napco panels and the Conti-
nental CA3000 software. For distances up to 50’
using an RS232 cable, or 100’, using CAT5 cable,
the GEM-RS232KIT is available. This kit provides
a direct-connect from the PC to the Napco Alarm
Panel. For longer distance communications, or for
installations with multiple Napco panels, a Napco
NetLinkTM TCP/IP Module (NL-MOD) is available.
The Napco NetLink option provides added flex-
ibility since the panel(s) can be installed anywhere
there is a network connection—in the next room or
the next town over.
Feature Description
Gemini Alarm Panels The CA3000 communicates with the Gemini P3200,
P9600 & X255. (Firmware specific)
Alarm Panel
Communications Options
The CA3000 communicates with the NAPCO
panels over R232 or TCP/IP. (Additional hardware
may be required)
Central Station
Capability
Alarms come directly into the CA3000 GUI for
central station-like monitoring capability.
Cardholder Control Cardholders can be setup to arm or disarm the
NAPCO panel or area at any CA3000 access reader.
Bi-directional Control CA3000 can trigger relays in the NAPCO panel and
vice-versa.
Advanced Scripting Wizard-driven interface that allows programming of
more powerful Links
NAPCO Event-to-DVR
Integration
Trigger DVR recording upon any NAPCO alarm.
Watch video for any NAPCO panel event.
Emergency Override CA3000 has complete manual override capability to
arm or disarm NAPCO panels.
Unlimited Panels There is no preset limit to the amount of NAPCO
panels the CA3000 can communicate with.
Audit Trail** Track alarm panel arm & disarm activity by user/
cardholder.
Panel Status** The CA3000 can give visual control for panel ready/
arm-disarm status at the reader level
*The NAPCO alarm panel interface is available as an add-on option for CA3000 V2.0 or
higher. **Some advanced features require CA3000 V2.5.



Additional Functionality*
Linking
All NAPCO alarm panel events can be used as triggers for
advanced functionality built into the CA3000 program. The
user has the power to create a link within the CardAccess
program to use an event from the NAPCO panel to trig-
ger one, or many, outputs on any Continental panel on the
system.
Scripting
The user also has the ability to create an advanced script
within the CardAccess Scripting service to trigger addition-
al functionality within CardAccess program using a NAPCO
alarm event.
Feedback
The CA3000 can be setup to give a visual indication, by way
of relay control, of the status of the NAPCO panel is at a
reader level.
DVR Integration:
Continental Access has taken integration to the next level
by combining two separate interfaces into one. The CA3000
has direct integration between the DVR and NAPCO panel
interfaces. This allows the user to trigger DVR recording on
any NAPCO panel event. It also allows video association
and retrieval for any NAPCO panel event.
*Please contact CI for detailed information. Some features
require advanced training & programming.
NAPCO Gemini Panel NAPCO
Keypad
Model
Min. Keypad
Version
Min Panel
Firmware
Version
Gem-X255 RP1CAe2 V 8C 4A
Gem-X255 K1CA V 8C 4A
Gem-P9600/3200 RP1CAe2 V 8C 50B
Gem-P9600/3200 K1CA V 8C 50B
The CA3000/Napco Interface requires the latest panel firmware be
installed. Please use the chart above as a reference to determine panel
compatibility.
For more information, please contact your local sales representative or contact Continental Access at (631) 842-9400.
Continental Instruments, A Napco Security Group Company • 355 Bayview Ave., Amityville, NY 11701
Phone (631) 842-9400 • Fax (631) 842-9135 • www.cicaccess.com GSA GS-07F-00039H
CardAccess® and CI SQL 3000TM are trademarks of Continental/NAPCO, 2006 A501
NAPCO Integration
CA3NAPX Gemini Alarm Panel Interface


