National Instruments NI SCXI-1336 User manual

SCXI™
SCXI-1129 User Manual
256 Crosspoint High-Density Matrix
SCXI-1129 User Manual
February 2001 Edition
Part Number 322740A-01

Support
Worldwide Technical Support and Product Information
ni.com
National Instruments Corporate Headquarters
11500 North Mopac Expressway Austin, Texas 78759-3504 USA Tel: 512 794 0100
Worldwide Offices
Australia 03 9879 5166, Austria 0662 45 79 90 0, Belgium 02 757 00 20, Brazil 011 284 5011,
Canada (Calgary) 403 274 9391, Canada (Ottawa) 613 233 5949, Canada (Québec) 514 694 8521,
China (Shanghai) 021 6555 7838, China (ShenZhen) 0755 3904939, Denmark 45 76 26 00,
Finland 09 725 725 11, France 01 48 14 24 24, Germany 089 741 31 30, Greece 30 1 42 96 427,
Hong Kong 2645 3186, India 91805275406, Israel 03 6120092, Italy 02 413091, Japan 03 5472 2970,
Korea 02 596 7456, Mexico 5 280 7625, Netherlands 0348 433466, New Zealand 09 914 0488,
Norway 32 27 73 00, Poland 0 22 528 94 06, Portugal 351 1 726 9011, Singapore 2265886, Spain 91 640 0085,
Sweden 08 587 895 00, Switzerland 056 200 51 51, Taiwan 02 2528 7227, United Kingdom 01635 523545
For further support information, see the Technical Support Resources appendix. To comment on the
©Copyright 2001 National Instruments Corporation. All rights reserved.

Important Information
Warranty
The SCXI-1129 is warranted against defects in materials and workmanship for a period of one year from the date of shipment, as evidenced
by receipts or other documentation. National Instruments will, at its option, repair or replace equipment that proves to be defective during the
warranty period. This warranty includes parts and labor.
The media on which you receive National Instruments software are warranted not to fail to execute programming instructions, due to defects
in materials and workmanship, for a period of 90 days from date of shipment, as evidenced by receipts or other documentation. National
Instruments will, at its option, repair or replace software media that do not execute programming instructions if National Instruments receives
notice of such defects during the warranty period. National Instruments does not warrant that the operation of the software shall be
uninterrupted or error free.
A Return Material Authorization (RMA) number must be obtained from the factory and clearly marked on the outside of the package before
any equipment will be accepted for warranty work. National Instruments will pay the shipping costs of returning to the owner parts which are
covered by warranty.
National Instruments believes that the information in this document is accurate. The document has been carefully reviewed for technical
accuracy. In the event that technical or typographical errors exist, National Instruments reserves the right to make changes to subsequent
editions of this document without prior notice to holders of this edition. The reader should consult National Instruments if errors are suspected.
In no event shall National Instruments be liable for any damages arising out of or related to this document or the information contained in it.
EXCEPT AS SPECIFIED HEREIN,NATIONAL INSTRUMENTS MAKES NO WARRANTIES,EXPRESS OR IMPLIED,AND SPECIFICALLY DISCLAIMS ANY WARRANTY OF
MERCHANTABILITY OR FITNESS FOR A PARTICULAR PURPOSE.CUSTOMER’S RIGHT TO RECOVER DAMAGES CAUSED BY FAULT OR NEGLIGENCE ON THE PART OF
NATIONAL INSTRUMENTS SHALL BE LIMITED TO THE AMOUNT THERETOFORE PAID BY THE CUSTOMER.NATIONAL INSTRUMENTS WILL NOT BE LIABLE FOR
DAMAGES RESULTING FROM LOSS OF DATA,PROFITS,USE OF PRODUCTS,OR INCIDENTAL OR CONSEQUENTIAL DAMAGES,EVEN IF ADVISED OF THE POSSIBILITY
THEREOF. This limitation of the liability of National Instruments will apply regardless of the form of action, whether in contract or tort, including
negligence. Any action against National Instruments must be brought within one year after the cause of action accrues. National Instruments
shall not be liable for any delay in performance due to causes beyond its reasonable control. The warranty provided herein does not cover
damages, defects, malfunctions, or service failures caused by owner’s failure to follow the National Instruments installation, operation, or
maintenance instructions; owner’s modification of the product; owner’s abuse, misuse, or negligent acts; and power failure or surges, fire,
flood, accident, actions of third parties, or other events outside reasonable control.
Copyright
Under the copyright laws, this publication may not be reproduced or transmitted in any form, electronic or mechanical, including photocopying,
recording, storing in an information retrieval system, or translating, in whole or in part, without the prior written consent of National
Instruments Corporation.
Trademarks
LabVIEW™, Measurement Studio™, National Instruments™,ni.com
™, NI-DAQ™,PXI
™,andSCXI
™are trademarks of National Instruments
Corporation.
Product and company names mentioned herein are trademarks or trade names of their respective companies.
WARNING REGARDING USE OF NATIONAL INSTRUMENTS PRODUCTS
(1) NATIONAL INSTRUMENTS PRODUCTS ARE NOT DESIGNED WITH COMPONENTS AND TESTING FOR A LEVEL OF
RELIABILITY SUITABLE FOR USE IN OR IN CONNECTION WITH SURGICAL IMPLANTS OR AS CRITICAL COMPONENTS IN
ANY LIFE SUPPORT SYSTEMS WHOSE FAILURE TO PERFORM CAN REASONABLY BE EXPECTED TO CAUSE SIGNIFICANT
INJURY TO A HUMAN.
(2) IN ANY APPLICATION, INCLUDING THE ABOVE, RELIABILITY OF OPERATION OF THE SOFTWARE PRODUCTS CAN BE
IMPAIRED BY ADVERSE FACTORS, INCLUDING BUT NOT LIMITED TO FLUCTUATIONS IN ELECTRICAL POWER SUPPLY,
COMPUTER HARDWARE MALFUNCTIONS, COMPUTER OPERATING SYSTEM SOFTWARE FITNESS, FITNESS OF COMPILERS
AND DEVELOPMENT SOFTWARE USED TO DEVELOP AN APPLICATION, INSTALLATION ERRORS, SOFTWARE AND
HARDWARE COMPATIBILITY PROBLEMS, MALFUNCTIONS OR FAILURES OF ELECTRONIC MONITORING OR CONTROL
DEVICES, TRANSIENT FAILURES OF ELECTRONIC SYSTEMS (HARDWARE AND/OR SOFTWARE), UNANTICIPATED USES OR
MISUSES, OR ERRORS ON THE PART OF THE USER OR APPLICATIONS DESIGNER (ADVERSE FACTORS SUCH AS THESE ARE
HEREAFTER COLLECTIVELY TERMED “SYSTEM FAILURES”). ANY APPLICATION WHERE A SYSTEM FAILURE WOULD
CREATE A RISK OF HARM TO PROPERTY OR PERSONS (INCLUDING THE RISK OF BODILY INJURY AND DEATH) SHOULD
NOT BE RELIANT SOLELY UPON ONE FORM OF ELECTRONIC SYSTEM DUE TO THE RISK OF SYSTEM FAILURE. TO AVOID
DAMAGE, INJURY, OR DEATH, THE USER OR APPLICATION DESIGNER MUST TAKE REASONABLY PRUDENT STEPS TO
PROTECT AGAINST SYSTEM FAILURES, INCLUDING BUT NOT LIMITED TO BACK-UP OR SHUT DOWN MECHANISMS.
BECAUSE EACH END-USER SYSTEM IS CUSTOMIZED AND DIFFERS FROM NATIONAL INSTRUMENTS' TESTING
PLATFORMS AND BECAUSE A USER OR APPLICATION DESIGNER MAY USE NATIONAL INSTRUMENTS PRODUCTS IN
COMBINATION WITH OTHER PRODUCTS IN A MANNER NOT EVALUATED OR CONTEMPLATED BY NATIONAL
INSTRUMENTS, THE USER OR APPLICATION DESIGNER IS ULTIMATELY RESPONSIBLE FOR VERIFYING AND VALIDATING
THE SUITABILITY OF NATIONAL INSTRUMENTS PRODUCTS WHENEVER NATIONAL INSTRUMENTS PRODUCTS ARE
INCORPORATED IN A SYSTEM OR APPLICATION, INCLUDING, WITHOUT LIMITATION, THE APPROPRIATE DESIGN,
PROCESS AND SAFETY LEVEL OF SUCH SYSTEM OR APPLICATION.

Compliance
FCC/Canada Radio Frequency Interference Compliance*
Determining FCC Class
The Federal Communications Commission (FCC) has rules to protect wireless communications from interference. The FCC
places digital electronics into two classes. These classes are known as Class A (for use in industrial-commercial locations only)
or Class B (for use in residential or commercial locations). Depending on where it is operated, this product could be subject to
restrictions in the FCC rules. (In Canada, the Department of Communications (DOC), of Industry Canada, regulates wireless
interference in much the same way.)
Digital electronics emit weak signals during normal operation that can affect radio, television, or other wireless products. By
examining the product you purchased, you can determine the FCC Class and therefore which of the two FCC/DOC Warnings
apply in the following sections. (Some products may not be labeled at all for FCC; if so, the reader should then assume these are
Class A devices.)
FCC Class A products only display a simple warning statement of one paragraph in length regarding interference and undesired
operation. Most of our products are FCC Class A. The FCC rules have restrictions regarding the locations where FCC Class A
products can be operated.
FCC Class B products display either a FCC ID code, starting with the letters EXN,
or the FCC Class B compliance mark that appears as shown here on the right.
Consult the FCC web site http://www.fcc.gov for more information.
FCC/DOC Warnings
This equipment generates and uses radio frequency energy and, if not installed and used in strict accordance with the instructions
in this manual and the CE Mark Declaration of Conformity**, may cause interference to radio and television reception.
Classification requirements are the same for the Federal Communications Commission (FCC) and the Canadian Department
of Communications (DOC).
Changes or modifications not expressly approved by National Instruments could void the user’s authority to operate the
equipment under the FCC Rules.
Class A
Federal Communications Commission
This equipment has been tested and found to comply with the limits for a Class A digital device, pursuant to part 15 of the FCC
Rules. These limits are designed to provide reasonable protection against harmful interference when the equipment is operated
in a commercial environment. This equipment generates, uses, and can radiate radio frequency energy and, if not installed and
used in accordance with the instruction manual, may cause harmful interference to radio communications. Operation of this
equipment in a residential area is likely to cause harmful interference in which case the user will be required to correct
the interference at his own expense.
Canadian Department of Communications
This Class A digital apparatus meets all requirements of the Canadian Interference-Causing Equipment Regulations.
Cet appareil numérique de la classe A respecte toutes les exigences du Règlement sur le matériel brouilleur du Canada.
Class B
Federal Communications Commission
This equipment has been tested and found to comply with the limits for a Class B digital device, pursuant to part 15 of the
FCC Rules. These limits are designed to provide reasonable protection against harmful interference in a residential installation.
This equipment generates, uses and can radiate radio frequency energy and, if not installed and used in accordance with the
instructions, may cause harmful interference to radio communications. However, there is no guarantee that interference will not
occur in a particular installation. If this equipment does cause harmful interference to radio or television reception, which can
be determined by turning the equipment off and on, the user is encouraged to try to correct the interference by one or more of
the following measures:
•Reorient or relocate the receiving antenna.
•Increase the separation between the equipment and receiver.
•Connect the equipment into an outlet on a circuit different from that to which the receiver is connected.
•Consult the dealer or an experienced radio/TV technician for help.

Canadian Department of Communications
This Class B digital apparatus meets all requirements of the Canadian Interference-Causing Equipment Regulations.
Cet appareil numérique de la classe B respecte toutes les exigences du Règlement sur le matériel brouilleur du Canada.
European Union - Compliance to EEC Directives
Readers in the EU/EEC/EEA must refer to the Manufacturer's Declaration of Conformity (DoC) for information** pertaining
to the CE Mark compliance scheme. The Manufacturer includes a DoC for most every hardware product except for those bought
for OEMs, if also available from an original manufacturer that also markets in the EU, or where compliance is not required as
for electrically benign apparatus or cables.
* Certain exemptions may apply in the USA, see FCC Rules §15.103 Exempted devices,and§15.105(c). Also available in
sections of CFR 47.
** The CE Mark Declaration of Conformity will contain important supplementary information and instructions for the user or
installer.

Conventions
The following conventions are used in this manual:
»The »symbol leads you through nested menu items and dialog box options
to a final action. The sequence File»Page Setup»Options directs you to
pull down the File menu, select the Page Setup item, and select Options
from the last dialog box.
This icon denotes a note, which alerts you to important information.
This icon denotes a caution, which advises you of precautions to take to
avoid injury, data loss, or a system crash.
bold Bold text denotes items that you must select or click on in the software,
such as menu items and dialog box options. Bold text also denotes
parameter names.
italic Italic text denotes variables, emphasis, a cross reference, or an introduction
to a key concept. This font also denotes text that is a placeholder for a word
or value that you must supply.
monospace Text in this font denotes text or characters that you should enter from the
keyboard, sections of code, programming examples, and syntax examples.
This font is also used for the proper names of disk drives, paths, directories,
programs, subprograms, subroutines, device names, functions, operations,
variables, filenames and extensions, and code excerpts.

©National Instruments Corporation vii SCXI-1129 User Manual
Contents
Chapter 1
Installing and Configuring the SCXI-1129
Installing the Software ...................................................................................................1-2
Safety Information .........................................................................................................1-3
Unpacking......................................................................................................................1-5
Installing the Hardware..................................................................................................1-5
Installing the SCXI-1129 Module into the SCXI Chassis...............................1-5
Connecting the SCXI-1129 to the DMM in a Single Chassis System ............1-7
Single 4-Slot Chassis Configuration .................................................1-8
Single 12-Slot Chassis Configuration ...............................................1-9
Connecting the SCXI-1129 to the DMM in a Multichassis System ...............1-10
4-Slot and 4-Slot Multichassis Configuration...................................1-10
4-Slot and 12-Slot Multichassis Configuration.................................1-12
12-Slot and 12-Slot Multichassis Configuration...............................1-14
Connecting the SCXI-1129 to the DMM in a PXI-1010 Chassis ...................1-16
DMM in PXI Slots 1 through 7 Configuration .................................1-16
DMM in PXI Slot 8 Configuration ...................................................1-17
Connecting the SCXI-1129 to the DMM in the PXI-1011 Chassis ................1-17
DMM in PXI Slots 1 through 3 Configuration .................................1-18
DMM in PXI Slot 4 Configuration ...................................................1-18
Accessing the SCXI-1129 through Other SCXI Modules Using
a DAQ Device ..............................................................................................1-19
Using a DAQ Device on a PXI-1010 Chassis .................................................1-21
Using a DAQ Device on a PXI-1011 Chassis .................................................1-21
Connecting the SCXI-1129 to an External DMM...........................................1-21
Configuring and Self-Test .............................................................................................1-22
Auto-Detecting Modules .................................................................................1-23
Manually Adding Modules..............................................................................1-24
Chapter 2
Using the SCXI-1129
Operating as a Matrix ....................................................................................................2-1
Configurations .................................................................................................2-2
4 × 16 Matrix Configuration............................................................................2-4
4 × 32 Matrix Configuration............................................................................2-6
8 × 16 Matrix Configuration............................................................................2-8
4 × 64 Matrix Configuration............................................................................2-10
8 × 32 Matrix Configuration............................................................................2-12

Contents
SCXI-1129 User Manual viii ni.com
16 × 16 Matrix Configuration ......................................................................... 2-14
Matrix Expansion............................................................................................ 2-16
Hardware and Software Scanning ................................................................................. 2-20
Hardware-Timed Scanning ............................................................................. 2-21
Hardware-Timed Scanning Using a DMM....................................... 2-21
Hardware-Timed Scanning Using External Instruments.................. 2-22
Synchronous Scanning ....................................................... 2-23
Handshaking Scanning....................................................... 2-23
Multimodule Scanning.................................................................................... 2-24
Chain Triggering............................................................................... 2-24
Example ............................................................................................ 2-24
Wire ORed ........................................................................................ 2-25
Dummy Entries................................................................................. 2-25
Software Scanning .......................................................................................... 2-26
Independent Switch Control............................................................................ 2-26
Appendix A
Specifications
Appendix B
Accessories
Appendix C
SCXI-1129 Block Diagram
Appendix D
SCXI-1129 Front Connector
Appendix E
Common Questions
Appendix F
Technical Support Resources
Glossary
Index

©National Instruments Corporation 1-1 SCXI-1129 User Manual
1
Installing and Configuring
the SCXI-1129
The SCXI-1129 is a 256 crosspoint high-density matrix module. It provides
up to a 4 × 64, 2-wire switch matrix configuration on an SCXI platform.
The SCXI-1129 can also operate as four 4 ×16, 2-wire matrixes;
two 4 ×32, 2-wire matrixes; or two 8 × 16, 2-wire matrixes.
Note Common matrix terminology describes matrixes by the number of rows by the
number of columns they contain. For example, four rows by 16 columns would be written
as 4 × 16.
Through the use of special terminal blocks (refer to Table 2-1, Terminal
Block Matrix Configuration), the SCXI-1129 can become many different
matrix types. Refer to Table 1-1 for a complete list of matrix
configurations.
To accommodate even larger testing needs, you can expand the matrix size
by combining additional modules. With the use of terminal blocks, you can
expand rows on the 4 × 16 and 16 × 16 matrixes, and you can expand rows
and columns on the 4 × 64 and the 8 × 32 matrixes. These modules support
the analog bus through a special adapter, the high-voltage analog bus
(HVAB) backplane adapter in the SCXI-1357/1358 kit, at the rear of the
module. This adapter allows you to expand the HVAB without complicated
Table 1-1. Possible Configurations of the SCXI-1129
Matrix Configuration Quantity
4× 16 4 each
8× 16 2 each
4× 32 2 each
4× 64 1 each
8× 32 1 each
16 × 16 1 each

Chapter 1 Installing and Configuring the SCXI-1129
SCXI-1129 User Manual 1-2 ni.com
wiring. By connecting multiple modules to the HVAB adapter, it is possible
to expand the matrix size without external row or column connectors. For
more information on matrix expansion, refer to the Matrix Expansion
section in Chapter 2, Using the SCXI-1129.
The SCXI-1129 is designed to work well at both low and high voltages.
For low-voltage measurements, the SCXI-1129 uses relays with < 9 µV
thermal offset to ensure accurate measurements. For details, refer to
Appendix A, Specifications.
Installing the Software
You can control the SCXI-1129 programmatically in an application
development environment (ADE) using NI-SWITCH. The supported
ADEs include LabVIEW, Measurement Studio, Visual Basic, and C or
C++ environments. To install software for the SCXI-1129, complete the
following:
1. Install your ADE if you have not done so already.
2. Insert your NI-SWITCH software CD into your CD drive.
The installation window appears automatically.
Note If the installation window does not appear, double-click the My Computer icon on
your PC desktop. Find the CD drive, and double-click it. In the CD directory, double-click
install.exe.
The NI-SWITCH and NI-DMM installation window offers three
choices:
•Install NI-DMM—Choose this selection if you want to install
only the software for the DMM.
•Install NI-SWITCH—Choose this selection if you want to install
only the software for the switches.
•Install NI-SWITCH and NI-DMM—Choose this selection if
you want to install the software for both the DMM and the
switches.
3. Click the Install NI-SWITCH option.
4. To install the instrument driver, Soft Front Panel(s), and ADE
examples, choose Programmatic and Interactive Support. To install
only the Soft Front Panel(s), choose Interactive Support Only.

Chapter 1 Installing and Configuring the SCXI-1129
©National Instruments Corporation 1-3 SCXI-1129 User Manual
Note The Interactive Support Only choice does not allow you to program the instrument
with any programming languages.
5. For advanced users only—when installing NI-SWITCH, the
Development Environments panel provides you with the following
choices:
•If you click the Advanced button on this panel, you can custom
install National Instruments drivers such as NI-DAQ, NI-IVI, and
NI-VISA.
•If you do not want to install certain drivers, click Advanced and
uncheck the driver(s) you do not want installed.
If a driver is already unchecked, your computer has the same driver or
a newer version of the driver already installed.
Note If a newer version of a driver is present on your PC, the installer will not overwrite
the driver.
6. After completing the installation, power off your computer.
Safety Information
The following cautions contain important safety information concerning
hazardous voltages.
Cautions Do not operate the device in an explosive atmosphere or where there may be
flammable gases or fumes.
Keep away from live circuits. Do not remove equipment covers or shields unless you are
trained to do so. If signal wires are connected to the device, hazardous voltages can exist
even when the equipment is powered off. To avoid a shock hazard, do not perform
procedures involving cover or shield removal unless you are qualified to do so and
disconnect all field power prior to removing covers or shields.
Equipment described in this document must be used in an Installation Category I1
environment per IEC 60664-1. This category requires local level supply mains-connected
installation.
Do not operate damaged equipment. The safety protection features built into this device
can become impaired if the device becomes damaged in any way. If the device is damaged,
1Category I refers to a signal level such as voltages of an isolation transformer secondary on a PWB.

Chapter 1 Installing and Configuring the SCXI-1129
SCXI-1129 User Manual 1-4 ni.com
power the device off and do not use it until service-trained personnel can check its safety.
If necessary, return the device to National Instruments for service and repair to ensure that
its safety is not compromised.
Do not operate this equipment in a manner that contradicts the information specified in this
document. Misuse of this equipment could result in a shock hazard.
Do not substitute parts or modify equipment. Because of the danger of introducing
additional hazards, do not install unauthorized parts or modify the device. Return the
device to National Instruments for service and repair to ensure that its safety features are
not compromised.
Yo u must insulate all of your signal connections to the highest voltage with which the
SCXI-1129 can come in contact.
When using the device with high common-mode voltages, you must insulate your signal
wires for the highest input voltage. National Instruments is not liable for any damages or
injuries resulting from inadequate signal wire insulation. Use only 26-20 AWG wire with
a minimum voltage rating of 150 V and a temperature value of 60 °C for measuring up
to 150 V.
When connecting or disconnecting signal lines to the SCXI terminal block screw terminals,
make sure the lines are powered off. Potential differences between the lines and the SCXI
ground can create a shock hazard while you connect the lines.
Connections, including power signals to ground and vice versa, that exceed any of the
maximum signal ratings on the SCXI device can create a shock or fire hazard, or can
damage any or all of the boards connected to the SCXI chassis, the host computer, and the
SCXI device. National Instruments is not liable for any damages or injuries resulting from
incorrect signal connections.
If hazardous voltages (≥30 Vrms and42.4V
peak or 60 VDC) are present, you must connect
a safety earth-ground wire to the terminal block safety-ground lug, shown in Figure 1-1.
This complies with safety agency requirements and protects against electric shock when
the terminal block is not connected to the chassis. To connect the safety earth-ground to the
safety-ground lug, run an earth-ground wire from the signal source to the terminal block.
National Instruments is not liable for any damages or injuries resulting from inadequate
safety earth-ground connections.
Do not loosen or re-orient the safety-ground lug hardware when connecting the
safety-ground wire; to do so reduces the safety isolation between the high voltage and
safety ground.

Chapter 1 Installing and Configuring the SCXI-1129
©National Instruments Corporation 1-5 SCXI-1129 User Manual
Clean the module and accessories by brushing off light dust with a soft non-metallic brush.
Remove other contaminants with a stiff non-metallic brush. The unit must be completely
dry and free from contaminants before returning it to service. The terminal block must be
used with a UL-listed SCXI chassis.
Unpacking
Your SCXI-1129 module is shipped in an antistatic package to prevent
electrostatic damage to the module. Electrostatic discharge can damage
several components on the module. To avoid such damage in handling the
module, take the following precautions:
•Ground yourself using a grounding strap or by holding a grounded
object.
•Touch the antistatic package to a metal part of your computer chassis
before removing the module from the package.
Caution Never touch the exposed pins of connectors.
Remove the module from the package and inspect the module for loose
components or any sign of damage. Notify National Instruments if the
module appears damaged in any way. Do not install a damaged module into
your computer.
Store your SCXI-1129 module in the antistatic envelope when not in use.
Installing the Hardware
The following section describes how to install your SCXI-1129 for use
with SCXI chassis, National Instruments data acquisition (DAQ) devices,
and National Instruments digital multimeters (DMMs).
Installing the SCXI-1129 Module into the SCXI Chassis
You need the following items to complete the installation:
•SCXI-1129
•SCXI chassis
•1/8 in. flathead screwdriver

Chapter 1 Installing and Configuring the SCXI-1129
SCXI-1129 User Manual 1-6 ni.com
To install your SCXI-1129 module into the SCXI chassis, refer to
Figure 1-1 while completing the following steps:
Figure 1-1. Installing the SCXI-1129 into an SCXI Chassis
1. Power off the computer that contains the DAQ/DMM device or
disconnect it from your SCXI chassis.
2. Power off the SCXI chassis. Do not insert the SCXI-1129 module into
a chassis that is powered on.
3. Insert the SCXI-1129 module into the rightmost slot. Gently guide the
module into the module guides and push it to the back of the slot until
the connectors make good contact. The module must be firmly
engaged; however, do not force the module into place.
Note When installing the SCXI-1129 module in an SCXI chassis, the rightmost slot
(when the chassis is viewed from the front) must be filled first, then fill the slot to the left
with the next SCXI-1129. You can load other SCXI modules from left to right.
1 AB0+
2 AB0–
3NI4060forPCI
4 AB2+
5AB2–
6 HV8-BAN4
7SH9MD-9MD
8 2-Slot HVAB-Backplane Adapter
9SCXIChassis
10 SCXI-1129 Module
2
3
4
5
6
7
8
9
10
1

Chapter 1 Installing and Configuring the SCXI-1129
©National Instruments Corporation 1-7 SCXI-1129 User Manual
4. Insert any other SCXI modules into the remaining slots in the same
manner as described in step 3.
5. Secure all the SCXI-1129 modules to the SCXI chassis using both
thumbscrews.
To configure your SCXI-1129, follow the procedures for your system in the
sections that follow.
Connecting the SCXI-1129 to the DMM in a Single Chassis System
You need the following items for this installation:
•SCXI-1000/1000DC/1001 chassis with the SCXI-1129 modules
installed
•SCXI-1357 (4-slot)/1358 (12-slot) kit
–1-, 2-, and/or 8-slot HVAB-backplane adapter
–HV8-to-BAN4 cable
–SH9MD-9MD cable
–Two or three 8-position high-voltage plugs
•DMM
•1/8 in. flathead screwdriver
Consult your SCXI chassis documentation and DMM documentation for
additional instructions and warnings. Your SCXI-1129 modules and any
other SCXI modules should already be installed in the chassis according
to their installation instructions.
Caution Before you proceed with your connections, make sure you power off your
SCXI chassis.

Chapter 1 Installing and Configuring the SCXI-1129
SCXI-1129 User Manual 1-8 ni.com
Single 4-Slot Chassis Configuration
To make connections in the single 4-slot chassis configuration, refer to
Figure 1-2 while completing the following steps:
Figure 1-2. 4-Slot Single Chassis Installation
1. Install the 2-slot HVAB-backplane adapter behind slots 3 and 4.
2. Install additional 1-slot HVAB-backplane adapters behind slots 1
and 2 if needed.
3. Install the 8-position HVAB plugs to connect the HVAB-backplane
adapters as needed.
4. Connect the HV8-BAN4 cable from the DMM to the HVAB connector
behind slot 4.
5. Connect the SH9MD-9MD cable from the DMM to the AUX IN
connector.
6. You can install any additional SCXI-1129 modules in any slot that has
an HVAB-backplane adapter behind it.
1 SCXI-1129 Module
2 4-Slot SCXI Chassis
3 2-Slot HVAB-Backplane Adapter
4 1-Slot HVAB-Backplane Adapter
5 8-Position HVAB Plug
6 NI 4060 for PCI
7SH9MD-9MDCable
8 HV8-BAN4 Cable
7
8
1
345
26

Chapter 1 Installing and Configuring the SCXI-1129
©National Instruments Corporation 1-9 SCXI-1129 User Manual
Note In this configuration, a SCXI-1129 is required in slot 4 to establish communication
with the chassis. If slot 4 is empty, the system will not operate. It is this module that you
must specify in Measurement & Automation Explorer (MAX) as the cabled module to
the DMM.
Single 12-Slot Chassis Configuration
To make connections in the single 12-slot chassis configuration, refer to
Figure 1-3 while completing the following steps:
Figure 1-3. 12-Slot Single Chassis Installation
1. Install the 8-slot HVAB-backplane adapter behind slots 5 through 12.
2. Install additional 2-slot and 1-slot HVAB-backplane adapters behind
slots 1 through 4 if needed.
3. Install the 8-position HVAB plugs to connect the HVAB-backplane
adapters as needed.
1 SCXI-1129 Module
2 12-Slot SCXI Chassis
3 2-Slot HVAB-Backplane Adapter
4 1-Slot HVAB-Backplane Adapter
5 8-Position HVAB Plug
6NI4060forPCI
7 SH9MD-9MD Cable
8 HV8-BAN4 Cable
9 8-Slot HVAB-Backplane Adapter
9
7
8
1
34
5
2
6

Chapter 1 Installing and Configuring the SCXI-1129
SCXI-1129 User Manual 1-10 ni.com
4. Connect the HV8-BAN4 cable from the DMM to the HVAB connector
behind slot 12.
5. Connect the SH9MD-9MD cable from the DMM to the AUX IN
connector behind slot 5.
6. You can install any additional SCXI-1129 modules in any slot that has
an HVAB-backplane adapter behind it.
Notes Do not connect the SH9MD-9MD cable to the AUX IN connector behind slot 4 on
the 2-slot HVAB-backplane adapter.
An SCXI-1129 is required in slot 12 to establish communications with the chassis. If slot
12 is empty, the system will not operate. It is this module that you must specify in MAX as
the cabled module to the DMM.
Connecting the SCXI-1129 to the DMM in a Multichassis System
The following sections describe how to configure the following
multichassis configurations:
•4-slot and 4-slot multichassis configuration
•4-slot and 12-slot multichassis configuration
•12-slot and 12-slot multichassis configuration
You can also create larger configurations.
4-Slot and 4-Slot Multichassis Configuration
In addition to the items needed for a single chassis system, you need the
following to install this configuration:
•SCXI-1357 multichassis expansion kit
–HV8-HV8 cable
–SH9MD-9MD cable
–Two8-positionHVABplugs
–One 2-slot HVAB-backplane adapter
–Two 1-slot HVAB-backplane adapters

Chapter 1 Installing and Configuring the SCXI-1129
©National Instruments Corporation 1-11 SCXI-1129 User Manual
To make connections in the 4-slot and 4-slot multichassis configuration,
refer to Figure 1-4 while completing the following steps:
Figure 1-4. 4-Slot to 4-Slot Multichassis Configuration Parts Locator Diagram
1 2-Slot HVAB Backplane Adapter
2 8-Position HVAB Plug
3 1-Slot HVAB Backplane Adapter
4 HV8-BAN4 Cable
5NI4060forPCI
6 SH9MD-9MD Cable
7 4-Slot SCXI Chassis
8 SH9MD-9MD Cable
9 HV8-HV8 Cable
10 4-Slot SCXI Chassis
AB0+
AB0–
AB2+
AB2–
5
6
10
8
9
7
4
1 2 3
Other manuals for NI SCXI-1336
1
This manual suits for next models
1