National Specialty Lighting LED Mini Star II User manual

warning!
TO rEDUCE THE riSK OF FirE, ELECTriC SHOCK Or
inJUrY TO PErSOnS:
1. Turn off/unplug before mounting, interconnecting
fixtures, or replacing LED module.
2. Do not look directly into LEDs when lit.
3. Do not operate fixture(s) with missing or damaged parts.
4. Do not install fixture(s) in any unventilated compartment.
Do not recess fixtures in any material. Surface mount only.
5. Use only Listed Class 2 LED Power Supplies per these
instructions, shown below.
6. If lead wire in excess of 36” fixture leads is required,
use only listed CL2 wire (NSL Part No. LW-18G-CL2) to
join fixtures to LED Driver and to interconnect fixtures.
Parallel wire only. Do not exceed 40 total feet from power
supply to last fixture.
7. ETL listed Damp Location for under cabinet, cabinet, and
shelf mount.
8. Securely mount with included double-sided tape and/or
wood screws. Wood screws offer a more permanent tem-
perature resistant option, and are required for all wood
installations.
9. Properly dispose of all small parts and packing material. Small
parts and packing material may be hazardous to children.
10.Install in accordance to manufacturer’s instructions, current
local codes, and/or the current National Electric Code (NEC).
inSTaLLaTiOn gUiDE
1. Each LED Mini Star II ships with the fixture,
including 36” of lead wire, attached double-sided
mounting tape, two mounting wood screws, and junc-
tion box with terminal block.
2. The complete system includes an LED Power Supply,
wiring to interconnect the system, and fixture(s).
Low voltage dimmer is optional.
3. Lay out the entire system without mounting any of the
parts. With the system laid out, make sure you have all
the required parts. Do not exceed 40 total feet from
power supply to last fixture.
4. Install fixtures as per the following two options:
A. Double-Sided Tape (Glass & Metal Surfaces)
(1) Clean mounting surface.
(2) Remove paper backing on double-sided tape.
(3) Firmly apply fixture to mounting surface.
B. Wood Screws (Wood Surfaces)
(1) Clean mounting surface.
(2) Remove fixture cover (see #1 and #5 in
Relamping LED Module on reverse side).
(3) Remove paper backing on double-side tape.
(4) Firmly apply fixture to mounting surface to
temporarily hold in place.
(5) Permanently attach fixture to mounting
surface using two included wood screws.
(6) Replace fixture cover.
5. Assure power supply is unplugged.
6. LED fixtures require polarity (+ and -) to be maintained
throughout the wiring. Connect the fixtures to
lead wire and power supply the side.
A) Note the postitions and negative connections
per Power Supply instructions.
Cover
Base
Wood Screws
Double-sided Tape
SingLE FixTUrE wiring SCHEmaTiC
Driver
LMSII-001
Terminal Block
Connector
LED Mini Star II
LMSII-001
Terminal Block
Connector
LED Mini Star II
LMSII-001
Terminal Block
Connector
LED Mini Star II
• All lead wire can be cut to exact lengths
• No custom cords to buy/stock
• No excess cord to hide
B) The LED Mini Star II fixture itself has two lead
wires with the following markings:
white only = “+”, and white with black stripes = “-”.
C) Measure twice, and then cut fixture leads and/or CL2
lead wire to desired length leaving at least 3/8”
stripped of insulation for terminal block connections.
D) Interconnect fixtures to power supply and/or lead
wire as per the Terminal Block Wiring Schematic
and the Single Fixture Wiring Schematic, below.
7. Passing either fixture leads or CL2 lead wire through a
cabinet will require a 3/16” diameter hole to be drilled.
8. Lead wire from the LED Mini Star II fixtures, or the
power supplies, should never penetrate any wall. Lead
wire from the LED Mini Star II fixtures or the power
supplies may penetrate through cabinets with access
doors to all interior spaces. Only the UL listed CL2 lead
wire may penetrate walls allowing the power supply to be
mounted in an adjacent room to the fixture application.
9. After assuring wiring is correctly installed as per all
diagrams, +/- polarity is maintained throughout, and all
terminal block screws are tightened, cover all terminal
block connections with junction box covers and included
screws. Mount junction box to surface using included
double-sided tape and/or wood screws. Affix lead wires
to mounting surface with included wire screw clips.
10.Plug in power supply, and turn on power supply switch
if applicable.
TErminaL BLOCK wiring SCHEmaTiC
White wire from fixture
Red wire
White wire
CL2 Lead wire
White with black stripes
wire from fixture
LED
Driver
Leads
or
CL2
Lead
wire
warning wiring inSTrUCTiOnS
1. Parallel wire LED Mini Star II to LED Driver.
2. For all applications use only listed 18G wire labeled
“CL2”, NSL part number LW-18G-CL2.
2. First, make sure LED Driver is not receiving power in any
way. Wire LED Mini Star II per these instructions, assure
proper tightness, on all strain reliefs, and then apply
120VAC power to LED Driver.
3. Do not try to adjust, fix, rewire, LED Mini Star II. In the
unlikely event LED module does not illuminate, check
wiring first. If this does not work, send LED Mini Star II
back for warranty replacement, if applicable.
NOTE: These products may represent a possible shock or fire
hazard if improperly installed or attached in any way.
Products should be installed in accordance with the
owner’s manual, current local codes, and/or the current
National Electrical Code (NEC).
To reduce the risk of fire, electrical shock, or injury to persons:
LED DRIVER SELECTION
Dimmable Min. Max.
Non-Dimming Fixtures Fixtures
LMS-24-60W Non-Dimming 1 10
LEDDR-24-120W Non-Dimming 1 18
TR24L20DC Both 2 5
TR24L40DC Both 4 10
TR24L60DC Both 8 15
TR24L96DC Both 14 25
If you do not wish to dim the LED Mini Star II use any of
the LED Drivers listed above and be careful to abide by
the minimum and maximum load values listed above.
If you wish to dim the LED Mini Star II, use only the
TR24L20DC, TR24L40DC, TR24L60DC, or TR24L96DC
and a magnetic low voltage dimmer listed below. All
dimmable LED Drivers have no minimum load when used
with an appropriate dimmer, however, all dimmable
LED Drivers are more efficient if specified as per the
minimum and maximum load values listed above.
Run appropriate lead wire from LED Mini Star II to LED
Driver (see below). Check all connections and clearances.
1. Our 24 Volt Direct Current dimmable LED magnetic
power supplies are designed to work with most
‘stand alone’ low voltage magnetic analog dimmers.
A recommended dimmer list is as follows:
LUTRON “Ariadni” AYLV-600PH
LUTRON “Lyneo” LXLV-600PL
LUTRON “Skylark” SLV-600P
LUTRON “Diva” DVLV-600PH
LUTRON “Glyder” GLV-600
Carefully following the dimmer instructions, dimmable
LED magnetic power supply instructions, and the NEC,
wire dimmer between 120VAC power input and 24 Volt
Direct Current dimmable LED power supply.

inSTaLLaTiOn
inSTrUCTiOnS
LED
Mini Star ii
Under Cabinets
Cabinets
Shelves
Display Cases
Work Stations
aPPLiCaTiOnS
NatioNal Specialty lightiNg
SPECiFiCaTiOnS
Fixture Dimensions 3” x 3” x 1/2”
Cover Finish White, Black,
Bronze, Aluminum
Base Finish Aluminum
Wiring/Connections Each fixture has 36” leads.
Fixture leads and optional
CL2 lead wire can be custom
cut to desired length.
Fixture leads, lead wire, and
power supply connect
together with included
terminal blocks. Each terminal
block connection is covered
with a plastic junction box
(see Single Fixture Wiring
Schematic).
Cord Color White
Voltage 24 volt direct current
Wattage 3.26 watts per fixture
LED Color Temperature 3000K +/- 200K
Mounting Doubled-side tape
and/or wood screws
Agency Approval ETL listed for under cabinet
or cabinet mount,
Damp Location. Listing
requires usage of Listed
Class 2 LED Power Supply
as shown.
Damp Locations
NatioNal Specialty lightiNg
ArchitecturAl And decorAtive lighting
louisville, co 80027
www.nslusa.com
© 2012 National Specialty Lighting 9/12
Cover
Base
Slot
In the highly unlikely event of an LED module failure,
please follow the instructions listed below:
CAUTION! If unit has recently been operating, glass, LED
module, and fixture are hot! Turn off fixture and allow it
to cool for 15 minutes before relamping.
CAUTION! Always replace LED module with power supply
switch in the OFF position.
NOTE: Using a thin pair of gloves during this procedure will
eliminate fingerprints on glass lens and LED module(s).
1. With a small screw driver, use slot in cover to remove
cover from base.
2. With a pair of needle nosed pliers, remove module
connector from printed circuit board.
3. Unscrew old LED module. Replace with new LED module
(NSL Part No. LEDMOD-24-LP). Tighten screws just snug.
4. Push male connector from LED module into female
connector in printed circuit board.
5. Replace cover by aligning slot in cover with slot in base.
Press firmly together.
rELamPing LED mODULE
Romex Romex CL2 Fixture Fixture
12/14 12/14 18 Lead Lead
AWG AWG AWG Wire Wire
120VAC ------> Low Voltage -----> 24VDC -----------> LMSII-001 -------> LED ----------> LMSII-001 ----------> LED ---------->
Analog Class 2 Terminal Mini Terminal Mini
Magnetic Dimmable Block Star II Block Star II
Dimmer LED Power and and
Supply Junction Box Junction Box
DIMMING INSTALLATION FLOW CHART
NOTE: If you Do Not want LED Mini Star II to dim, the above charts are modified to remove “Low Voltage Analog Magnetic Dimmer”,
the power supply becomes “Non-Dimmable” LEDDR-24-120W. As always, check the current NEC and local building codes for
acceptance of your application design.
Romex Romex CL2 CL2 CL2
12/14 12/14 18 18 18
AWG AWG AWG AWG AWG
(If in wall) (If in wall)
120VAC ------> Low Voltage -----> 24VDC -----------> LMSII-001 -------> LED ----------> LMSII-001 ----------> LED ---------->
Analog Class 2 Terminal Mini Terminal Mini
Magnetic Dimmable Block Star II Block Star II
Dimmer LED Power and and
Supply Junction Box Junction Box
DIMMING REMOTE POWER SUPPLY INSTALLATION FLOW CHART
No Low Voltage Wire Interior to Walls or Structural Members
Low Voltage CL2 Wire Interior to Walls or Structural Members
Required
Wire:
Required
Wire:
System
Layout:
System
Layout:
Fixture stranded lead wire should never penetrate any wall. Fixture
stranded lead wire may penetrate through cabinets with access doors
to all interior spaces. Only the UL listed CL2 lead wire may penetrate
walls allowing the power supply to be mounted in an adjacent room
to the fixture application.
After assuring wiring is correctly installed as per all diagrams,
+/- polarity is maintained throughout, and all terminal block screws
are tightened, cover all terminal block connections with junction
box covers and included screws. Mount junction box to surface using
included double-sided tape and/or wood screws. Lead wires should be
neatly affixed to mounting surface with WSC-004 wire screw clips.
Popular Light Fixture manuals by other brands

Chauvet Professional
Chauvet Professional ROGUE R1 BEAM WASH user manual

Martin
Martin MAC 250 Krypton user manual

Cooper Lighting
Cooper Lighting Halo L3232E Specification sheet

Stageline
Stageline ODW-2410RGBW instruction manual

Lightolier
Lightolier Paralyte 2424 PLA2G9LS26U specification

Lightolier
Lightolier Lytespan 83ED17S specification