Current as of 2016-11-03
Instruction Manual for Vacuum Valve II
(with Pushbutton Release)
PN# 25624, 25625, 25626, 25627
Thank you for your purchase of a NAUTICAM product
At NAUTICAM, we pride ourselves in the ability to recognise the requirements
of professional as well as amateur underwater photographers and fulfill them
through the innovative designs of our products We strive to achieve a high
level of user-friendliness by allowing stress-free installation and easy
operation of all important functions of the camera
Each product is individually inspected and water pressure tested to ensure
optimum quality
Please read this manual carefully before using the product, this will maximise
its performance as well as its lifetime
All NAUTICAM Products are warranted against any material and
manufacturing defects for two years from the date of purchase for consumer
use
This warranty only applies to products purchased from authorised
NAUTICAM dealers and does not extend beyond the original retail purchaser
To return your product for service, please contact your regional authorized
service centre(s) Please note that this warranty only applies when the product
is purchased in the territory where the service centre is located
NAUTICAM does not hold responsibility for damage, of any nature, to any
equipment used with and/or placed within our products
NAUTICAM accepts no liability for any loss of captured images or the inability
to capture images even if it is due to the malfunctioning of our products
Unauthorised modifications and/or repairs of our products will automatically
invalidate the warranty
ARTS
Extra for 25626, 25627 with offset connector:
OUSI G
For 25624, 25625:
Remove the plug of the M14 accessory port from the housing Remove the cap
from the vacuum valve Tighten the vacuum valve to the housing with the tool
provided
For 25626, 25627:
Remove the M14 bulkhead from the housing Tighten the offset connector
with vacuum valve to the housing with the spanner provided Then tighten the
M14 bulkhead onto the offset connector
Note: Slightly lubricate the O-ring with Nauticam lubricant.
ACUUM
Remove the cap of the vacuum valve Connect the hand pump to the valve and
pump several times until it reaches the target vacuum level The LED light will
turn flashing yellow while vacuum is building up, then steady green when the
target vacuum level is reached
ttention: fter the target vacuum is reached, i.e. steady green light, attach
the cap back to the vacuum valve
It is recommended to leave the housing for at least 20mins to ensure it is
sealed If the LED light changes from steady green light to rapidly flashing
yellow light, that means there is a leakage and please check every O-ring and
conduct the vacuum test again
Please ensure that the cap is attached back to the vacuum valve before going
underwater
Vacuum can be released by pushing the red release button
ttention: Please DO NOT attempt to go over the designated vacuum level, i.e.
stop pumping when the LED turn green. Excessive vacuum level may lead to
the malfunction of the camera and lens.
Note: lthough the vacuum indicator is designated to compensate for a certain
amount of temperature variation, it is recommended to conduct the vacuum
test in an environment where the temperature is stable.
FFSET
C
O ECTOR
(
FOR
25626,25627
O LY
)
Remove the cap of the vacuum valve Insert the fastening tool onto the
vacuum valve Unscrew the vacuum valve from the offset connector with the
fastening tool provided
All manuals and user guides at all-guides.com