manuals.online logo
Brands
  1. Home
  2. •
  3. Brands
  4. •
  5. NAVIS
  6. •
  7. Monitor
  8. •
  9. NAVIS W410/BAT User manual

NAVIS W410/BAT User manual

This manual suits for next models

2

Other NAVIS Monitor manuals

NAVIS W410EX/D User manual

NAVIS

NAVIS W410EX/D User manual

NAVIS WL12/D User manual

NAVIS

NAVIS WL12/D User manual

NAVIS LW410HUB User manual

NAVIS

NAVIS LW410HUB User manual

NAVIS LW410 User manual

NAVIS

NAVIS LW410 User manual

Popular Monitor manuals by other brands

Samsung ME32C user manual

Samsung

Samsung ME32C user manual

ViewSonic VA926-LED user guide

ViewSonic

ViewSonic VA926-LED user guide

Furuno Mu 120c Operator's manual

Furuno

Furuno Mu 120c Operator's manual

Asus VB171D - 17" LCD Monitor Service manual

Asus

Asus VB171D - 17" LCD Monitor Service manual

AOC 9GLR Technical specifications

AOC

AOC 9GLR Technical specifications

DMG RAFFAELLO manual

DMG

DMG RAFFAELLO manual

AOC LM720 - 17" Technical specifications

AOC

AOC LM720 - 17" Technical specifications

Sony Trinitron GDM-F500 Service manual

Sony

Sony Trinitron GDM-F500 Service manual

Memorex MT1701 user guide

Memorex

Memorex MT1701 user guide

ViewSonic VE510s-4 Service manual

ViewSonic

ViewSonic VE510s-4 Service manual

Farenheit T-1503CM instruction manual

Farenheit

Farenheit T-1503CM instruction manual

Ditel DINOS DN129/AT Quick installation guide

Ditel

Ditel DINOS DN129/AT Quick installation guide

Sony SDM-S51 Specifications

Sony

Sony SDM-S51 Specifications

Kenwood DMX1025BT quick start guide

Kenwood

Kenwood DMX1025BT quick start guide

Dell S2409WFP user guide

Dell

Dell S2409WFP user guide

EverFocus EN-7517E instruction manual

EverFocus

EverFocus EN-7517E instruction manual

Dell P3222QE user guide

Dell

Dell P3222QE user guide

Panasonic TH152UX1 - 152" PLASMA TV Service manual

Panasonic

Panasonic TH152UX1 - 152" PLASMA TV Service manual

manuals.online logo
manuals.online logoBrands
  • About & Mission
  • Contact us
  • Privacy Policy
  • Terms and Conditions

Copyright 2025 Manuals.Online. All Rights Reserved.

W410/BAT DISPLAY UNIT
MANUAL
Models: W410/BAT/D, W410XB/BAT/D
PREFACE
Thank you for purchasing the Navis anemometer. This manual provides information for the best performance and safe application of
the anemometer display unit. This manual does not cover the anemometer sensors for which the manuals will come separately.
Read this manual carefully before starting the installation. Keep this manual after installation for future reference.
INTRODUCTION
W410/BAT models are long-range receiver/display units which receive data from NAVIS wind sensors, display various wind data, and
use alarms for warnings about excess wind speed. Smartphone compatibility (W410XB/BAT model only) allows real-time wind data
monitoring on smartphones or tablets.
1. Display
2. Red and Yellow alarm lights
3. ON/OFF switch
4. Keys
5. Buzzer
6. SMA antenna connector
Figure 1. (W410/BAT display unit –front panel)
The W410/BAT display is compatible with NAVIS sensors: WS 010-1 (wind speed sensor, standard range), WS 011-1 (wind speed
sensor, extended range), WSD 010-1 (wind speed/direction sensor, standard range), WSD 011-1 (wind speed/direction sensor, extended
range).
MOUNTING
Select the position where the signal reception is strong enough under all conditions. Use remote antenna if necessary.
Display unit can be mounted onto the ferrous surface with four mounting magnets (optional accessories) or with mounting screws (not
enclosed) to any flat surface.
Mounting the display unit with screws:
Unscrew all 4 plastic screws and remove the front panel. Note that the screws can be pulled out only at the correct angle. Place the
rear panel of the display unit to the final mounting position and mark the position for the bores. Remove the casing and drill holes for
the mounting screws. Place the rear panel of the display unit in position and tighten the mounting screws. Attach the front panel of the
display unit with 4 plastic screws.
ANTENNA CONNECTION
Connect the enclosed antenna to the SMA connector on the display unit only when the display unit is switched OFF.
OPERATION
Display unit is activated by a switch on the side of the housing.
If the display unit is delivered as a set, with the sensor included, the correct sensor address is already set.
Otherwise please set the correspondent sensor address first. Check the address settings procedure in the chapter “SETTINGS”.
Turn the sensor ON by rotating the sensor cups (see sensor user manual).
Fresh wind data are received every two seconds. If data are not received for more than 30 seconds, the “No data” notification appears
on the display.
DISPLAY
Switching between pages:
With short presses of the HIST key you can open pages 2 and 3 to see the “Wind speed”and “Max alarm”history respectively.
The display will return to the first page by holding down the HIST key for 3 seconds or automatically after 1 minutes of inactivity.
1st page:
1. Current wind speed
2. Current wind speed bar graph
(set max alarm level is always on ¾ bar height)
3. Peak wind speed in the last 2 minutes bar graph
(set max alarm level is always on ¾ bar height)
4. 10 seconds average wind direction indicator (only at WSD sensor)
5. Unit of wind speed measurement
6. Temperature at sensor
7. Max Alarm value
8. Pre alarm value
9. Received data package indicator
10. Signal strength value (in dB) Figure 4. (Display –1st page)
11. Sound alarm OFF icon
2st page:
8-hour peak wind speed history graph.
Each column represents peak wind speed during the 5-minutes interval
3st page:
8-hour “Max alarm”history graph with 5-minutes intervals Figure 5. (Display –2nd page) Figure 6. (Display –3rd page)
DISPLAY BACKLIGHT
Switched ON and OFF by short pressing the upper key.
SIGNAL RECEPTION
The reception symbol blinks when the display unit receives a signal from the sensor (every 2 seconds if the reception is good).
Signal strength is numerically shown in dB:
•-105 dB is approximately the limit where display unit stops receiving
• -100 dB and lower means very week signal
• -95 ... -90 dB is considered as still acceptable
• -85 dB and higher is a good signal
When the sensor doesn't send data (in the OFF state) or when the signal is lost for a more than 30 seconds, the “No data” notification
appears on the display, indicating that the receiver doesn’t receive data from the sensor (sensor OFF or out of range).
RANGE
Connection between the sensor and display unit works on a free 868 MHz band. The range is up to 500 meters (1300 meters with an
extended range sensor) when the sensor is mounted at a height of 10 meters and when there is no obstacle between the sensor and
the display unit. Inside buildings the range is much smaller. Normally the signal can be received through two to three walls.
ALARMS
The alarms consist of red and yellow alarm lights signalization and sound signal from buzzer.
OPERATION OF ALARMS
Pre-alarm: when set value is exceeded, the yellow light will start blinking, and the buzzer will sound with short interruptions.
Max alarm: when set value is exceeded, the red light will flash, and the buzzer will sound continuously.
SOUND ALARM
By holding-down the upper key for 2 seconds you can switch the sound alarm ON and OFF.
The sound alarm is active each time the display unit is turned ON.
In the settings menu, the sound alarm can be disabled permanently.
SMARTPHONE COMPATIBILITY (W410XB/BAT/D model only)
A data packet is transmitted over Bluetooth every second. With the free “Windy Anemometer” application you can read the data of the
current, average, and maximum wind speed, as well as wind direction and temperature, or view history graphs on your smartphone.
In the application settings menu, always set the address corresponding to the address of the W410XB/BAT sensor.
The range is up to 40 meters. Inside a building, the range is much smaller. The range also varies with the type of smartphone or tablet.
Application “WINDY ANEMOMETER” can be downloaded from Google Play or Apple Store.
Android: Applications requires device with Android 4.3 or newer with Bluetooth Low Energy (BLE).
Apple: In iOS settings for the Windy Anemometer application configure parameter "Allow Location Access" to "While Using the App".
SETTINGS: SETTINGS PROCEDURE
1. Hold down the SET key to enter the settings menu. If password protection is active, enter the correct password. The group of
settings displays on the display.
2. Select the group by using the up and down keys and press the SET key to view the selected group.
3. Using the up and down keys select the parameter you wish to adjust and press the SET key to view the selected parameter. The
adjustable parameter blinks.
4. With the up and down keys, adjust the parameter value. Press SET to enter the new value and move to the next parameter.
5. Exiting the settings menu: hold down the SET key to move back one level.
The anemometer also returns to the main screen after 2 minutes of inactivity.
SETTINGS: SETTINGS LIST
Max Alarm
select to set Max Alarm parameters
Pre Alarm
select to set Pre Alarm parameters
General
select to set general parameters
Settings: Max Alarm (RED ALARM LIGHT, continuous sound)
Factory preset:
Setting range:
Description:
Wind Speed:
72 km/h
1 - 50 m/s
Max Alarm limit
ON Delay:
0 s
0 - 600 s
Minimum time for excess wind speed to activate the Max alarm
OFF Delay:
0 min
0 - 60 min
Alarm switch OFF delay after wind speed drops below preset level
Settings: Pre Alarm (YELOW ALARM LIGHT, interrupted sound)
Factory preset:
Setting range:
Description:
Wind Speed:
52 km/h
1 - 50 m/s
Pre Alarm 2 limit
ON Delay:
0 s
0 - 600 s
Minimum time of exceed Wind speed to activate the Pre Alarm 2
OFF Delay:
0 min
0 - 60 min
Alarm switch OFF delay after wind speed drop below preset level
Settings: General
Factory preset:
Setting range:
Description:
Sensor
Address:
Enclosed
sensor
1 - 255
Set the sensor address of your wind speed or wind speed / wind
direction sensor
WS Averaging:
2 s
2, 10 or 30 s
Averaging period for displayed wind speed
WS units:
km/h
m/s, km/h, mph or
knots
Unit for displaying wind speed
Temperature
units:
0C
0C or 0F
Unit for displaying Temperature
Password:
NO
NO /
YES - 0000 to 9999
Activation of password protection and setting the password
Sound Alarm:
ON
ON/OFF
Switching sound alarm ON and OFF
Language:
English
English/French
Language selection
WS Cal.
Factor
+0,0%
Calibration factor for wind speed (-15,0 ...+15,0%
in 0,5% steps)
WD Cal.:
0°
-180°… +180°
Calibration angle for wind direction (-180°...+180°in 1°steps)
Bluetooth*
ON
ON/OFF
Power ON/OFF Bluetooth transmitter
* applicable only for W410XB model
RECEIVER BATTERY REPLACEMENT
Take off the front lid of receiver and replace the battery (3 x 1,5 V Alkaline, C type, LR14).
RESET OF DISPLAY UNIT
With upper button pressed at power ON, RESET is performed (all settings except »Sensor Address«, »WS Cal. Factor« and »WD
Cal.« go to default values).
TROUBLESHOOTING
Symptom
Action
The receiver/display is turned OFF
- check the switch position on the side of the housing
- check if a batteries of display unit are not empty
The receiver/display unit cannot read
the sensor
(“No data” appears on the display)
- check if the correct sensor address is set on the display unit
- make sure the sensor is not in sleep mode (turn the cups to wake up the sensor)
- check the sensor battery –replace the battery if needed
- check the operation at a reduced distance to the display/receiver
Interrupting and weak sensor signal
- check for obstructions between sensor and display/receiver unit
- place the sensor or display/receiver in a different position with better signal reception
- reduce distance to the display/receiver
- change or add antenna for the display/receiver unit
TECHNICAL DATA
Wind speed measurement range: 0,6 - 50,0 m/s
Wind direction measurement range: 0°- 359°
Temperature measurement range: -30....+60 °C
Wind speed units: m/s, km/h, knots, mph
Temperature units: °C, °F
Wind speed averaging period: selectable 2 s, 10 s, 30 s
Wind direction averaging period: 10 s
Wind speed resolution: 0,1 m/s
Wind direction resolution: 1 0
Temperature resolution: 1 0C
Wind speed accuracy: +/- 2,5 %
Wind direction accuracy: +/- 2,5°
Temperature accuracy: +/- 1°C
Operating range: with standard range sensor up to 500 m
with extended range sensor up to 1300 m
with connected Yagi antenna 3 - 5 x nominal range
Operating Frequency: 868 MHz
Temperature operating range: -30 ... +60 °C
Sound signal (integrated): 85 dB
Antenna input: 50 Ohm, SMA connector
Measuring rate: every 2 sec
Bluetooth data transmission rate (W410XB/BAT/D): 1 second
Bluetooth transmission frequency (W410XB/BAT/D): 2,4 GHz
Bluetooth output power (W410XB/BAT/D): + 3 dB
Application name on Google Play/Apple Store: WINDY ANEMOMETER
Battery: 3 x 1,5 V Alkaline, size C, LR14 (not included)
Battery life: up to 1 year
Material, casing: PC (Polycarbonate)
Dimensions: 130 ×80 ×36 mm
Weight: 260 g
Subject to technical modification without notice.
ACCESSORIES (optional)
1. Magnetic display mounting assembly
2. External antenna with 3 m cable
3. External Yagi antenna with 3 m cable
1. 2. 3.
WARRANTY (LIMITED)
The warranty period of NAVIS products is one year after the date of purchase. During the limited warranty period any defective
product will be repaired or replaced with a comparable product without charges. The claimed product will be repaired or replaced
only when returned to the store where it was purchased together with original invoice. Failure to follow these instructions may
invalidate the warranty. The limited warranty does not cover the battery or damage of any kind, including physical damage caused
accidentally or misuse of the product. NAVIS does not accept responsibility for any problems which may arise from applications
other than those the product was designed for. Any liability for direct or indirect damage caused by product failure is excluded.
110119
__________________________________________________________________________________________________________________________________________
NAVIS elektronika d.o.o., Poljska cesta 11, SI-1241 Kamnik, [email protected]