Unpacking
Nemesis UV-C Tower comes either attached or wrapped on a pallet of in a ATA flight case, if
you purchased one. Your Nemesis Tower has been sent out in perfect working order. Inspect
your unit for any damages that may have been incurred during shipping. If the packaging
appears damaged, carefully inspect your unit. If you find any damage, contact customer
support before notifying your distributor.
Contents:
Nemesis Tower
Bag
12 UVC Radiators
Cable
Manual
Customer Support
The customer support line is available for any inquiries on your
product. Visit https://www.nemesisuvc.com/
For servicing or repairs, contact: NEMESIS – 24/7 – (972) 423-0075

Nemesis UV-C Tower User Manual_V1
_________________________________________________________________________________________
_________________________________________________________________________________________
3
Benefits of UVC Technology
• UVC radiation has been proven to be effective against waterborne and airborne pathogenic
micro-organisms including those responsible for cholera, hepatitis, polio, typhoid, giardia,
cryptosporidium and many other bacterial, viral and parasitic diseases
• UVC installations have low capital and operation cost
• UVC technology is environmentally friendly
• UVC installations are easy to operate and to maintain
• UVC radiation has no harmful effect when overdosed on surfaces, water or air
• UVC radiation works instantly and the effectiveness does not depend on the temperature
• UVC disinfection is a physical process: no substances are added
• The UVC disinfection effect is directly related to the UV dose (which is the product of
intensity and exposure time of the micro-organisms) so it’s effectiveness can be simply
measured once the system design is validated
UV-C RENTAL DISCLAIMER
The products being sold pursuant to this Agreement must be installed correctly and used properly
to be effective. If Nemesis or Crossfade Design are not responsible for the installation, then
Nemesis nor Crossfade Design will not be responsible for any damages caused by improper
installation or usage. Nemesis nor Crossfade Design make no representations, guarantees or
assurances as to the effectiveness of using a UV lighting system for sanitization. Although much
scientific evidence exists proving the effectiveness of UV-C sanitation, Nemesis nor Crossfade
Design does not warrant that 100% of the viruses, bacteria and germs shall be eliminated. UV-C
sanitation times are calculated by information provided by the lamp manufacturer. Times vary
according to distance and type of viruses, bacteria and germs to be eliminated. Customer
understands and accepts that the use of UV lighting can cause fading and discoloration of some
materials and that the Nemesis nor Crossfade Design are not responsible for any damages
whatsoever to any materials or equipment due to the use of the products.

Nemesis UV-C Tower User Manual_V1
_________________________________________________________________________________________
_________________________________________________________________________________________
4
Safety
HIGH INTENSITY ULTRAVIOLET LIGHT
RISK OF EXPOSURE TO ULTRAVIOLET RADIATION
AVOID DIRECT EYE AND SKIN EXPOSURE
Never allow humans to be in direct radiation of UV-C light. Since UV-C is not visible light, the
fixtures have safety protocols built-in (occupancy sensors, red LEDs to indicate they are
luminated, audible beep and beacon) to avoid exposure. Many studies have been done on the
effects of UV-C and the results show minimal effect in the short term. Studies have shown
damage to the eye can be an effect of exposure to UV-C light. It is required that humans and
animals not be exposed. Long term exposure may produce fading or degradation of some
materials. Amounts of degradation are completely dependent on types and quality of materials
and if they have UV-C protection built-in. The FDA approved a waiver on UV-A, UV-B and UV-C
in the 1950’s. More information is available from the FDA at:
https://www.fda.gov/media/136533/download
For the proper, safe and effective use of your device it is ESSENTIAL that the user follows all
guidelines and instructions in this manual. Proper installation is essential for the effectiveness of
this product.
There can be no persons in the room while the Nemesis Tower is running. UV-C can cause
damage to skin and eyes if exposed. If the LED beacon is on, the room should be clear. DO NOT
look at the device during operation.
Nemesis is equipped with motion sensors that will shut the unit down completely. While these
measures are in place, ensure the room is clear before turning on the device, and ensure the
device is off before re-entering.
The fan, and other vents must remain unobstructed to allow for the best possible operating
conditions, and to ensure the longevity pf your device.
Disconnect the device from power source before cleaning the device or replacing the radiators.
There are no serviceable parts inside the unit. DO NOT attempt to do any repairs beyond basic
cleaning and lamp replacement. Any attempts to repair the unit will void the warranty. Nemesis
is not responsible for any damages or harm caused by your repairs.

Nemesis UV-C Tower User Manual_V1
_________________________________________________________________________________________
_________________________________________________________________________________________
5
General Guidelines
DO NOT attempt any repairs on the Nemesis Tower. Anything beyond replacing the radiator and
basic cleaning must be done by a trained technician. Attempts to repair the device will void the
warranty.
DO NOT operate the device while people are in the area.
Avoid touching the tubes. Oils and moisture from the skin can cause the coating on the radiator
to deteriorate.
Trademarks & Patents
Nemesis, the Nemesis logo and Nemesis UV_C Tower are registered trademarks Crossfade
Design, LLC (d/b/a Nemesis UV-C) in the United States. US Patent Pending.
Copyright Notice
The works of authorship contained in this manual, including, but not limited to, all design, text
and images are owned by Crossfade Design, LLC.
Limited Warranty
1. Terms and Conditions: This limited warranty is subject to the terms listed below.
2. For warranty service: M-F 9-5
3. Warrant is void if
4. This is not a service contract.
5. Nemesis reserves the right to change the product and doesn’t have to change it for you
6. This is the only written warranty applicable to this product and supersedes all prior
warranties and written descriptions of warranty terms and conditions heretofore
published

Nemesis UV-C Tower User Manual_V1
_________________________________________________________________________________________
_________________________________________________________________________________________
6
Technical Specifications:
Features:
• 360 degree disinfection
• Designed in USA. Ships From USA.
• Safe and environmental- No harsh chemicals, No landfill.
• Convenient Key Fob Remote or Web Application for setting timers and schedules
• Emits germicidal wavelength of 254nm
• Kills 99% of all viruses and bacteria
• Motion activated temporary shutdown
• Audible alerts during use
• Visual alerts during use
• Optional flight case
• Heavy duty slip-cover protection
• Custom branded labeling
• All aluminum construction
Lamp Source: Philips TUV 55 W HO lamp technology. UV-C 254nm
Dimensions:
Tower Height with casters: 70.5” x Width (diameter): 29.5”
Tower Height in case: 75.5” x Width: 32” x 32”
Weight:
Tower with casters: 307.5 lbs
Tower mounted in case tray with casters: 345.5 lbs
Tower mounted in case: 487.5 lbs
Empty case: 206.5 lbs
Input voltage: AC110-120V 50Hz
7 amps @ 120v
Rating: Indoor use only

Nemesis UV-C Tower User Manual_V1
_________________________________________________________________________________________
_________________________________________________________________________________________
7
Fixture Overview

Nemesis UV-C Tower User Manual_V1
_________________________________________________________________________________________
_________________________________________________________________________________________
8
Using the Nemesis UV-C Tower
Step 1: Unpack your unit and remove the slipcover.
Step 2: Determine the size of your space and place the unit as close to the center of that space
as possible and make note of time needed for proper disinfection by referring to the
disinfection chart on the following page.
Step 3: Plug in the included power cable and switch on the power switch on top of the base.
Step 4: Place included placards on entry doors or around space to warn of UVC disinfection in
progress.
Step 5: Once you are clear of the unit use either your key fob or web-based application to start
the system.
Step 6: You will hear an alert running as soon as the system starts. The disinfection time starts 1
minute from activation. Then run appropriate amount time for your space. If you are using the
web app you can set a timer or schedule for disinfection duration.
Step 7: Deactivate the unit at the completion of pre-determined disinfection time before
entering the space to remove the tower.

Nemesis UV-C Tower User Manual_V1
_________________________________________________________________________________________
_________________________________________________________________________________________
9
CONNECTING YOUR Wi-Fi DEVICE
WARNING: Pressing the button on your Wi-Fi unit for less than 5 seconds will turn the Tower on.
1. Turn the Wi-Fi unit to Hot Spot Mode
a. Hold the button for 5 seconds, the blue indicator light should blink two short,
one long
b. Press button again, and hold for 5 seconds until the blue indicator flashes
continuously
2. Then connect to the device’s Wi-Fi through your phone
i. ITEAD-##########
ii. Password:12345678
3. Go to the UV Inc Application
4. Hit the + button in the bottom center
5. Press ‘Compatible Mode’ at the bottom of the screen
6. Press “Next”
7. Set the network you would like to control your Tower from by entering it here
a. NOTE: 2.4 GHZ Wi-Fi is required for these devices
8. Press “Next”, then press “Connect”
9. In your device settings to connect to the ITEAD-########## device
10. Once connected, the “Connect” button should read “Next”
11. The device will begin to configure, then when asked to connect the device to the Wi-Fi
network, press “Accept”
12. The device will take a few minutes to fully configure into the network, leave your Tower
connected to power for a few minutes after this step.
APP USE
1. After setup, you will be prompted to name your Tower
2. On the Home Screen, your newly connected Tower should appear.
3. Tapping on that Tower will open a second menu, from here you can
a. Power on your Tower
b. Set a schedule
c. Set a Timer
d. Set a Loop Timer
e. If needed, you can update your device from here as well:
i. Press the “…” button in the top right of your screen
ii. From here you will open the settings, and an option to update to the
current software version will be available.

Nemesis UV-C Tower User Manual_V1
_________________________________________________________________________________________
_________________________________________________________________________________________
10
Photometrics and Disinfectant Times*
Contaminated surfaces are everywhere. Whether you need a second line of defense, or an
alternative to chemicals or liquids- Nemesis™ is an essential tool in protecting yourself against
the invisible germs lurking on all the objects you touch. With a press of a button, a high-output
array of 360º UVC (ultraviolet C) light at a 254nm germicidal wavelength is emitted from
multiple Philips radiator’s, effectively sanitizing surfaces in a very effective fast method. The
Nemesis™ UVC light damages DNA of bacteria and viruses, rendering up to 99% unable to
replicate, thus unable to cause infection. Read our FAQ section for more detailed information on
how UVC works
Our high quality durable and robust designs are built to withstand the most rugged
conditions. You can now use this technology anywhere to sanitize small and large spaces up to
40’ x 40’ with a single unit.
*Note: Times are calculated but may not be wholly accurate for specific rooms. A specialized
design for your space is necessary for complete efficacy and efficiency

Nemesis UV-C Tower User Manual_V1
_________________________________________________________________________________________
_________________________________________________________________________________________
11
Cleaning
• Unplug fixture from AC power before starting
• Never use alcohol or solvents
• Use vacuum or air compressor (on low PSI setting) and soft brush to remove dust on
fixture & vents
• Clean fixture with a moist, lint-free cloth

Nemesis UV-C Tower User Manual_V1
_________________________________________________________________________________________
_________________________________________________________________________________________
12
User Manual - Version 1
Updated: 6-1-2020
www.nemesisuvc.com
(972) 423-0075