YELLOWRIVER YR-IP1024Q User manual


OUTDOOR LED PAR LIGHT
Model: YR-IP1024Q

Contents
Section 1.Getting Started
Unpacking
Safety Instruction
Section 2. Set Up
Installation
Controlling Board
Machine Connection
Section 3. troubleshooting
Troubleshooting
Section 4. Reference
Control Menu
DMX Protocol
Specification
DMX protocol
DMX512 Channel Chart:(8CH)
Chan
nel
Function
Description
CH1
Dimmer
R、G、B、W dimmer,linear dimmer from
dark to bright
CH2
Strobe
R、G、B、W Strobe from slow to fast
CH3
Function
0—50: Control DMX channel ;51 - - 100:
jump change ;101—150 :fade change ;
151—200:pulse change;201—255:sound
active
CH4
Speed
Speed from slow to fast

CH5
R Dimmer
Red linear dimmer from dark to bright
CH6
G Dimmer
Green linear dimmer from dark to bright
CH7
B Dimmer
Blue linear dimmer form dark to bright
CH8
W Dimmer
White linear dimmer from dark to bright
Specification
Voltage:AC110V-240V
Frequency:50/60Hz
Machine Power:240W
LED power:10W X24PCS(RGBW 4IN1)
Beam Angle:25°
Control Mode:DMX512/Auto/Manual/Sound Active
Channel:8CH
Outdoor: IP65
4
DE00
Seven color Combination of change (01—99),
press button B, C for change the speed
5
BEBE
Seven color sound change
6
R255
Red color (000—255), press B, C for
change the color
7
G255
Green color (000—255), press B, C for
change the color
8
B255
Blue color(000—255),
press B, C for change the color
9
W255
White color (000—255),press B, C for
change the color

Section 1.Getting Started
Unpacking
Safety Instruction
Unpacking
1pc Fixture
1/6pc AC Power Cable with Plug
1/6pc Signal Convertor Cable
1pc User Manual
Thanks for choosing our product. Carefully unpack the box and check the
contents to ensure that all parts are present and in good conditions. If anything
damaged in transit, notify the shipper immediately and keep the packing material
for inspection. Again, please save the carton and all packing materials. If a fixture
must be returned to manufacturer, it is important that the fixture be returned in the
original manufacturer box and packing.

Safety Instruction
Please conserve this manual as operation guidance. If you sell this product to
other user, please make sure that they also receive this user manual.
Always make sure that you are connecting to the proper voltage and that the
line voltage you are connecting to is not higher than that stated on the decal or
rear panel of the fixture.
If the fixture is intended to indoor use only. To prevent risk of fire or shock, do
not expose fixture to rain or moisture. Make sure there are no flammable,
explosive or corrosive materials surrounded in 10meters while operating.
The unit must be installed in a location with adequate ventilation, at least 5m
away from adjacent surfaces. Be sure that no ventilation slots are blocked.
Some fixture may carry high heat, do not aim at objective more than 2minutes.
Safe rope should be used to install machine. Bearing of safe rope should be
more than 3times of the machine weight.
Always disconnect from the power source before servicing or replacing
fuse/lamp and be sure to replace with same fuse/lamp size and type. Cut off
power before moving, repairing and cleaning the machine.
To avoid electric shock, all fixtures must be connected to circuits with a suitable
earth connection.
Always secure fixture using a safety chain and carrying handles.
Do not operate at ambient temperatures higher than 104℉(40℃).
In case of failure or mis-function occurred, stop using immediately. Never try to
repair the fixture by yourself. Repairs carried out by unskilled people can lead to
damage or malfunction. Please contact the nearest authorized technical
assistance center. Buy the same spare parts/components from manufacturer
directly.
Make sure the power cable is never crimped or damaged.
Colors cannot be
mixed
Random color
mixing is on
Turn off random color mixing
Fixture does not
reset correctly
Electronic or
mechanical failure
Contact service technician
Lamp missing or
blown
Disconnect fixture and replace lamp
No light, lamp cuts
out intermittently, or
burns out too
quickly
Fixture or lamp is
too hot
Allow fixture to cool. If problem persists,
contact service technician
Section 4. Reference
Control Menu
For your safe,please read this user manual carefully before turn on
the fixture. This machine should be operated by qualified engineer!

DMX Protocol
Specification
Control Menu
No
.:
Display
Function
1
D001
CH8 address code(001-512), press button
B,C to change for change the code number.
2
CC00
Seven color Jump(01—99), press button B, C
for change the speed
3
CP00
Seven color pulse change, shade (01—99),
press button B, C for change the speed
ATTENTION:
Section 3. Troubleshooting
Problem
Probable Cause(s)
Remedy
No power to fixture
Check power cables
Primary fuse blown
Replace fuse
No response from
fixture when power
is applies
Secondary fuse
blown
Replace fuse
Controller not
connected
Connect controller
Incorrect
addressing of the
fixtures
Check address setting on fixture and controller
Bad data link
connection
Inspect cables and correct poor connections
and/or broken cables.
Conflict between
tracking and vector
control
Eliminate scene cross-fade on controller
Data link not
terminated
Insert termination plug in output of last fixture
Fixture resets but
does not respond
correctly to
controller(DMX
mode operation)
Defective fixture or
2 devices
transmitting on link
Bypass fixtures one at a time until normal
operation is regained: unplug both connectors
and connect them directly together
Maximum 8 PCS fixtures connected by Daisy chain connection.

Avoid direct eye exposure to the light source while it is on.
Do not power on and power off the fixture frequently
When use DMX controller, please make sure that there is no interference
sources(e.g. intercom, high frequency radio waves and radiation source)
There are no user serviceable parts inside the unit. Do not open the housing or
attempt any repairs yourself. In case of your unit may require service, please
Any damage that cased by violating this manual is out of warranty, our company
will not take the responsibility.
Section 2. Set Up
Installation
Controlling Board
Machine connection
Installation
This machine should be mounted through the screw holes of truss. Safety
rope is a must to fix fixture well. Make sure truss and safety rope have strong
load capacity to bear more than 3 times of machine weight .
This machine should be installed by qualified technician.
Controlling Board

1. LED Display Panel
2. Button
MENU
Switch menu function
UP
Scroll upwards
DOWN
Scroll downwards
ENTER
Confirm by pressing ENTER
3. DMX Signal Input
3 PIN XRL cable with IP 65 male connector for DMX512 signal input;
4. DMX signal output
3 PIN XRL cable with IP 65 female connector for DMX512 signal output;
5. Power Input
AC power cable with male connector for power input;
6. Power Output
AC power cable with female connector for power output;
Machine Connection
Master and slave: select one machine as master, press the menu to choose the
function you want. Press other machines’ address to be DMX state. Use signal
cable to connect machines one by one. Then slave machines will run the same as

master machine.
Use controller to control lot of machines: if all machines are set the same menu
data, or different manual data, after use signal cable to connect to controller, all
machines will be controlled by controller. (before connect to controller, all
machines should be in the same channel mode 8CH).
Other YELLOWRIVER Light Fixture manuals
Popular Light Fixture manuals by other brands

QTX Light
QTX Light Blue Weapon Laser user manual

Altman
Altman CHALICE Installation and instruction manual

Badabulle
Badabulle B015007 instruction manual

Lightolier
Lightolier AGH specification

Hubbell
Hubbell Kim Lighting Wall Director WD18 installation instructions

Triarch
Triarch 31062 Assembly instructions

Triarch
Triarch Indoor Lighting 29643 Assembly instructions

Commercial Electric
Commercial Electric FP2X2/4WY/WH/HDT Use and care guide

Raytec
Raytec VARIO2 i16 Quick start up guide

Lightolier
Lightolier Calculite ProSpec PA1H3870 specification

POLUX
POLUX FUNNY DEL78-Y-RGB operating manual

Cameo
Cameo ROOT PAR 4 user manual