Stone massage therapy is a wonderful procedure that can bring many
therapeutic benefits when properly administered. As with any therapy, proper
care must be practiced to ensure the safety of the individual receiving the
therapy. Before using the SPA PROTM , we strongly recommend instruction on
stone massage therapy from a qualified, professional therapist.
IMPORTANT SAFEGUARDS . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3
SAVE THESE INSTRUCTIONS . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3
CAUTIONS . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4
BEFORE USING YOUR SPA PROTM FOR THE FIRST TIME . . . . . . . . . . . . . . . . . . . . . . . 4
DIRECTIONS FOR USE . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 5
MAINTENANCE AND CLEANING . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 6
GET TO KNOW YOUR SPA PROTM MASSAGE STONE HEATER . . . . . . . . . . . . . . . . . 6-7
LIMITED WARRANTY . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 8
FIVE EASY STEPS TO SATISFACTION . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 9
2
Do not operate when bathing or in the shower.
Extreme caution must be used when moving an appliance containing hot liquids.
Do not fill the water reservoir to more than 1 inch below the top rim. Place appliance on a
level surface.
Always place the stones in the water reservoir first, then add water.
Do not use if you have rashes, burns, cuts or other skin irritations, or if you have sensitive or
damaged skin.
Never place an appliance in a tub or sink to fill while it is plugged into a wall outlet.
ELECTROCUTION HAZARD!
Always test the temperature of each stone by touching it with your fingers first and hold it in
your hand before placing the heated stone on another person.
Use heat resistant gloves or slotted wooden spoon to lift heated stones from the SPA PROTM
to avoid burns or scalding.
Never add boiling or steaming water to avoid scalding and/or burns.
Table of Contents
Introduction to Stone Message Therapy

1. The SPA PROTM Massage Stone Heater should not be used if the following conditions
are present: Tuberculosis, tumors, open wounds, hemorrhages, bruises, broken skin,
thrombosis or phlebitis, varicose veins, or undetermined joint pain or pain in the calf.
2. People who are pregnant, have diabetes or other illness, should have a physicians
approval prior to receiving therapy.
3. Contact your physician if you have any questions concerning the therapeutic affects of
this appliance.
4. If you experience unusual pain, contact your physician before using the SPA PROTM.
5. Discontinue use of the SPA PROTM if you experience any discomfort from the therapy
and contact your physician.
6. Do not use this appliance when you are feeling drowsy or are going to fall asleep.
7. The SPA PROTM is not a toy. USE EXTREME CAUTION when using this appliance
and PLEASE keep children away from this appliance.
Unpack your SPA PROTM Massage Stone Heater completely and REMOVE THE WATER
RESERVIOR, ALL PACKAGING MATERIAL AND INFORMATION LABELS. Place unit
in a WELL VENTILATED AREA ON A HEAT RESISTANT SURFACE.
Turn the Temperature Control full counter-clockwise and plug the SPA PROTM into a suitable
120 volt AC outlet.
Turn the Temperature Control to the “Preheat” setting and allow the SPA PROTM to operate
for approximately 60 minutes, or until any odor or smoking disappear.
Some smoke and odor are a normal part of curing the heating element and will not occur
again during normal spa use.
When curing is completed, turn the Temperature Control full counter-clockwise to turn the
appliance off, unplug SPA PROTM from wall outlet and allow unit to cool.
Wash all stones before each use.
Place a hand towel on the bottom of the SPA PROTM water reservoir. Place all stones on
top of the towel.
Before plugging appliance into outlet, add sufficient water, fill the water reservoir to just
above the stones or fill to maximum capacity, but no more that 1-inch below the top rim.
Turn the Temperature Control full counter clockwise. Place Cover on appliance.
Plug power cord into a standard 120 VAC grounded outlet. Turn the Temperature Control to
“Preheat” position for about 20 to 30 minutes to speed warm up time. When the water
reaches the desired temperature, turn the Temperature Control to the “Operating
Range” to maintain the proper temperature.
Use an accurate thermometer to measure water temperature in the Water Reservoir to
ensure that stones are at a proper therapeutic temperature. Consult a professional
therapist for correct stone temperatures if you are unsure.
Model 4418 (18 qt version) only: The Indicator Lamp cycles off and on with the heating
element. The element is heating when the lamp is on.
Carefully remove the first stone from the SPA PROTM Water Reservoir. Test the
temperature of the stone by touching it with your finger, then hold in your hand. The
temperature should feel warm to the touch, but not uncomfortable.
When the therapy session is finished, turn the Temperature Control full counter-
clockwise to turn unit off. Always unplug appliance when not in use.
Do not drop stones into the SPA PROTM heating unit. This may damage the appliance.
Use care when removing or replacing stones.
Do not apply warm stones to areas of your body that are inflamed.
5
CAUTIONS
DIRECTIONS FOR USE
Before Using Your SPA PRO
TM
For The First Time

Clean unit after each therapy session.
Turn Temperature Control to minimum and unplug SPA PROTM from wall outlet before
cleaning.
Allow appliance to cool to room temperature before cleaning or add or removing parts.
Carefully remove all stones first, then remove the water.
Clean Water Reservoir and Cover with a solution of warm soapy water, then rinse with
clean water and dry with a towel.
Wipe Main Heating Unit with a damp cloth. Special care must taken when cleaning the
Main Heating Unit. NEVER immerse Main Heating Unit in water or place in a sink to
rinse.
Rinse the stones in warm water with a small amount of mild detergent added. Rinse
stones with clean warm water and allow to dry before storing.
7
Get To Know Your SPA PROTM Massage Stone Heater
Maintenance and Cleaning

This manual suits for next models
1
Table of contents
Other Nesco Heater manuals