Netberg Demos R130 M2 User manual

Netberg Demos R130 M2 server

Netberg Demos R130 M2 server

iii
Table of Contents
1. Netberg Demos R130 M2 server ........................................................................................ 1
1.1. Conventions ............................................................................................................ 2
1.2. Acronyms ................................................................................................................ 3
1.3. Safety Information ................................................................................................... 6
1.3.1. Important Safety Instructions ......................................................................... 6
1.4. Disclaimer ............................................................................................................... 7
1.5. About the Server ..................................................................................................... 8
1.5.1. Introduction .................................................................................................. 8
1.5.2. A Tour of the System ................................................................................. 11
1.5.3. System Overview ........................................................................................ 11
1.5.4. System Front View ..................................................................................... 13
1.5.5. Front Control Panel .................................................................................... 13
1.5.6. System Rear View ...................................................................................... 14
1.5.7. System Rear I/O ......................................................................................... 15
1.5.8. Power Sub-System ..................................................................................... 15
1.5.9. LED Status Definitions ................................................................................ 16
2. Installing hardware ........................................................................................................... 19
2.1. Safety measures ................................................................................................... 20
2.2. Top Cover ............................................................................................................. 21
2.2.1. Closing the Top Cover ................................................................................ 21
2.3. Hard drives ........................................................................................................... 23
2.3.1. Removing a 2.5” Hard Drive ........................................................................ 23
2.3.2. Installing a 2.5” Hard Drive into a Hard Drive Tray ........................................ 24
2.3.3. Installing a 2.5” Hard Drive ......................................................................... 24
2.3.4. Removing a 3.5” Hard Drive ........................................................................ 25
2.3.5. Installing a 3.5” and 2.5” Hard Drive into a Hard Drive Tray ........................... 26
2.3.6. Installing a 3.5” Hard Drive ......................................................................... 27
2.4. Power Supply Unit ................................................................................................. 28
2.4.1. Removing a Power Supply Unit ................................................................... 28
2.4.2. Installing a Power Supply Unit ..................................................................... 28
2.5. Processor Heat Sinks ............................................................................................ 30
2.5.1. Removing a Heat Sink ................................................................................ 30
2.5.2. Installing a Heat Sink .................................................................................. 31
2.6. Processors ............................................................................................................ 32
2.6.1. Removing a Processor ................................................................................ 32
2.6.2. Installing a Processor ................................................................................. 35
2.7. Memory Modules ................................................................................................... 37
2.7.1. Removing a Memory Module ....................................................................... 37
2.7.2. Installing a Memory Module ........................................................................ 37
2.8. Expansion Cards (Optional) ................................................................................... 39
2.8.1. Installing a Riser Assembly ......................................................................... 39
2.8.2. Installing the PCI-E Riser Assembly ............................................................. 40
2.8.3. PCI-E Expansion Card ................................................................................ 41
2.9. Air Duct ................................................................................................................ 43
2.9.1. Removing the Air Duct ................................................................................ 43
2.9.2. Installing the Air Duct .................................................................................. 43
2.10. Fan Modules ....................................................................................................... 45
2.10.1. Removing a Fan Module ........................................................................... 45
2.10.2. Installing Fan Assembly ............................................................................ 46

Netberg Demos R130 M2 server
iv
2.11. Expander Backplane ............................................................................................ 48
2.11.1. Removing the 2.5" Expander Backplane .................................................... 48
2.11.2. Installing the 2.5" Expander Backplane ...................................................... 50
2.11.3. Removing the HDD Backplane .................................................................. 51
2.12. Point to point backplane ...................................................................................... 55
2.12.1. Removing the HDD Backplane (3.5” HDD SKU) ......................................... 55
2.12.2. Installing the HDD Backplane (3.5” HDD SKU) ........................................... 56
3. BIOS Setup Utility ............................................................................................................ 58
3.1. Operation .............................................................................................................. 59
3.2. Setup Page ........................................................................................................... 60
3.3. Entering BIOS Setup ............................................................................................. 61
3.4. Keyboard Commands ............................................................................................ 62
3.5. Menu Selection Bar ............................................................................................... 64
3.6. Server Platform Setup Utility Screens ..................................................................... 65
3.7. Main Screen .......................................................................................................... 66
3.8. Advanced Screen .................................................................................................. 68
3.8.1. PCI Screen ................................................................................................ 69
3.8.2. PCI Express Settings Screen ...................................................................... 70
3.8.3. Trusted Computing Screen .......................................................................... 71
3.8.4. WHEA Screen ............................................................................................ 72
3.8.5. Processor Configuration Screen .................................................................. 72
3.8.6. Socket 0 CPU Information Screen ............................................................... 75
3.8.7. CPU Power Management Configuration Screen ........................................... 76
3.8.8. Runtime Error Logging Screen .................................................................... 78
3.8.9. SATA Controller Screen .............................................................................. 79
3.8.10. SAS Configuration Screen ......................................................................... 79
3.8.11. Intel TXT(LT-SX) Screen ........................................................................... 81
3.8.12. USB Configuration Screen ........................................................................ 82
3.8.13. Super I/O Configuration Screen ................................................................. 83
3.8.14. Serial Port 0 Configuration Screen ............................................................. 85
3.8.15. Onboard Device Configuration Screen ....................................................... 86
3.8.16. Console Redirection Screen ...................................................................... 87
3.8.17. Console Redirection Settings ..................................................................... 88
3.9. Chipset Screen ..................................................................................................... 90
3.9.1. North Bridge Screen ................................................................................... 91
3.9.2. Intel® VT-d Screen ..................................................................................... 92
3.9.3. South Bridge Configuration Screen .............................................................. 93
3.9.4. USB Configuration ...................................................................................... 94
3.9.5. ME Subsystem screen ................................................................................ 95
3.10. Server Management Screen ................................................................................. 97
3.10.1. System Event Log Screen ......................................................................... 99
3.10.2. FRU Information ..................................................................................... 100
3.10.3. BMC Network Configuration .................................................................... 101
3.11. Boot Option Screen ........................................................................................... 103
3.12. Security Screen ................................................................................................. 106
3.13. Exit Screen ........................................................................................................ 107
3.14. Loading BIOS Defaults ...................................................................................... 109
4. BIOS Update Utility ........................................................................................................ 110
4.1. BIOS Update Utility ............................................................................................. 111
4.2. Recovery Mode ................................................................................................... 112
4.3. Recovery Flow .................................................................................................... 113

Netberg Demos R130 M2 server
v
5. Server Management ....................................................................................................... 115
5.1. Console Redirection ............................................................................................ 116
5.2. Serial Configuration Settings ................................................................................ 117
5.3. Keystroke Mapping .............................................................................................. 118
5.4. Interface to Server Management .......................................................................... 119
5.5. PXE BIOS Support .............................................................................................. 120
5.6. Checkpoints ........................................................................................................ 121
5.7. Checkpoint Ranges ............................................................................................. 122
5.8. Standard Checkpoints .......................................................................................... 123
5.8.1. SEC Phase .............................................................................................. 123
5.8.2. PEI Phase ................................................................................................ 123
5.8.3. DXE Phase .............................................................................................. 125
5.8.4. PEI Beep Codes ....................................................................................... 128
5.8.5. DXE Beep Codes ..................................................................................... 128
5.8.6. ACPI/ASL Checkpoints .............................................................................. 129
5.8.7. OEM-Reserved Checkpoint Ranges ........................................................... 129
6. Server Management Software ......................................................................................... 130
6.1. Server System Overview ...................................................................................... 131
6.2. BMC Key Features and Functions ........................................................................ 132
6.3. Power System ..................................................................................................... 133
6.4. Front Panel User Interface ................................................................................... 134
6.4.1. Power Button ............................................................................................ 134
6.4.2. ID Button .................................................................................................. 134
6.4.3. LEDs ........................................................................................................ 134
6.5. LAN Interface ...................................................................................................... 136
6.5.1. Session and User ..................................................................................... 136
6.6. Serial Over LAN .................................................................................................. 137
6.7. Time Sync ........................................................................................................... 138
6.8. SEL .................................................................................................................... 139
6.9. Platform Event ..................................................................................................... 140
6.9.1. Platform Event Filter ................................................................................. 140
6.10. BMC Firmware Update ...................................................................................... 141
6.10.1. DOS Recovery Utility .............................................................................. 141
6.10.2. WebUI Update ........................................................................................ 141
6.11. Processor Error Detection .................................................................................. 142
6.11.1. Thermal Trip / Processor Hot ................................................................... 142
6.12. Watchdog .......................................................................................................... 143
6.12.1. Pre-Timeout Interrupt Support .................................................................. 143
6.13. IPMI 1.5 / 2.0 Command Support List ................................................................. 144
6.13.1. BMC Device and Messaging Commands .................................................. 144
6.13.2. BMC Watchdog Timer Commands ........................................................... 146
6.13.3. Chassis Commands ................................................................................ 146
6.13.4. Event Commands ................................................................................... 147
6.13.5. SEL Commands ...................................................................................... 147
6.13.6. SDR Repository Commands .................................................................... 148
6.13.7. FRU Inventory Device Commands ........................................................... 149
6.13.8. Sensor Device Commands ...................................................................... 149
6.13.9. LAN Command ....................................................................................... 150
6.13.10. SOL Command ..................................................................................... 150
6.13.11. PEF/PET Alerting Commands ................................................................ 150
6.13.12. OEM Command .................................................................................... 151

Netberg Demos R130 M2 server
vi
7. BMC Recovery ............................................................................................................... 153
7.1. Recovery Process in DOS System ....................................................................... 154
7.2. Recovery Process in Linux System ...................................................................... 155
8. Web Graphical User Interface (GUI) for ESMS ................................................................ 156
8.1. Using the Web GUI ............................................................................................. 157
8.2. Login ................................................................................................................... 158
8.3. Dashboard .......................................................................................................... 160
8.3.1. Device Information .................................................................................... 160
8.3.2. Network Information .................................................................................. 161
8.3.3. Sensor Monitoring ..................................................................................... 161
8.3.4. Event Logs ............................................................................................... 161
8.4. Server Information ............................................................................................... 162
8.5. FRU Information .................................................................................................. 163
8.5.1. Basic Information ...................................................................................... 163
8.5.2. Chassis Information .................................................................................. 163
8.5.3. Board Information ..................................................................................... 164
8.5.4. Product Information ................................................................................... 164
8.5.5. Server Component .................................................................................... 164
8.5.6. Server identify .......................................................................................... 165
8.5.7. Server Health Group ................................................................................. 166
8.5.8. Sensor Readings ...................................................................................... 167
8.5.9. Event Log ................................................................................................. 169
8.6. Configuration Group ............................................................................................ 170
8.6.1. Active Directory ........................................................................................ 170
8.6.2. DNS ......................................................................................................... 173
8.6.3. LDAP/E-Directory ...................................................................................... 175
8.6.4. Mouse Mode ............................................................................................ 178
8.6.5. Network .................................................................................................... 179
8.6.6. PEF ......................................................................................................... 181
8.6.7. RADIUS ................................................................................................... 187
8.6.8. Remote Session ....................................................................................... 189
8.6.9. SMTP ....................................................................................................... 190
8.6.10. SOL ....................................................................................................... 192
8.6.11. SSL ........................................................................................................ 193
8.6.12. User Management .................................................................................. 198
8.6.13. Virtual Media .......................................................................................... 201
8.7. Remote Control ................................................................................................... 203
8.7.1. Console Redirection .................................................................................. 203
8.7.2. Server Power Control ................................................................................ 210
8.8. Maintenance Group ............................................................................................. 212
8.8.1. Firmware Update ...................................................................................... 212
8.8.2. Preserve Configuration .............................................................................. 213
8.8.3. Restore Factory Defaults ........................................................................... 213
8.8.4. BIOS update ............................................................................................. 214
8.9. Log Out .............................................................................................................. 215
8.10. User Privilege .................................................................................................... 216
9. Rail Kit Assembly ........................................................................................................... 217
9.1. Installing the Rack Brackets ................................................................................. 218
9.2. Installing the Inner Rail ........................................................................................ 219
9.3. Installing the Outer Rail ....................................................................................... 221
10. Troubleshooting ............................................................................................................ 223

Netberg Demos R130 M2 server
vii
10.1. Server Boot Issue Topics ................................................................................... 224
10.2. System does not Boot after Initial Installation ...................................................... 225
10.2.1. Power Cord Not Plugged In ..................................................................... 225
10.2.2. Processor Issues .................................................................................... 225
10.2.3. Memory Issues ....................................................................................... 225
10.2.4. Monitor Issues ........................................................................................ 225
10.2.5. Power Supply, Chassis and Fan Issues ................................................... 226
10.2.6. Cable Issues ........................................................................................... 226
10.2.7. Electrical Short or Overload ..................................................................... 226
10.2.8. Defective Components ............................................................................ 226
10.3. System does not boot after Configuration Changes ............................................. 227
10.3.1. Hardware Changes ................................................................................. 227
10.3.2. Software Changes .................................................................................. 227
10.3.3. BIOS Changes ........................................................................................ 227
10.3.4. Installation Problems ............................................................................... 227
10.3.5. Troubleshooting External Connections ..................................................... 228
11. Installation and Assembly Safety Instructions ................................................................. 229
12. Server Safety Information ............................................................................................. 232
12.1. Safety Warnings and Cautions ........................................................................... 233
12.2. Intended Application Uses .................................................................................. 235
12.3. Site Selection .................................................................................................... 236
12.4. Equipment Handling Practices ............................................................................ 237
12.5. Power and Electrical Warnings ........................................................................... 238
12.6. Power Cord Warnings ........................................................................................ 239
12.7. System Access Warnings ................................................................................... 240
12.8. Rack Mount Warnings ........................................................................................ 241
12.9. Electrostatic Discharge (ESD) ............................................................................ 242
12.10. Other Hazards ................................................................................................. 243
12.11. Cooling and Airflow .......................................................................................... 244
12.12. Laser Peripherals or Devices ............................................................................ 245
13. Regulatory and Compliance Information ........................................................................ 246
13.1. Electromagnetic Compatibility Notices ................................................................. 248
13.1.1. FCC Verification Statement (USA) ........................................................... 248
13.1.2. Europe (CE Declaration of Conformity) ..................................................... 248
13.1.3. VCCI (Japan) .......................................................................................... 249
13.1.4. BSMI (Taiwan) ........................................................................................ 249
13.1.5. Regulated Specified Components ............................................................ 249
13.1.6. Restriction of Hazardous Substances (RoHS) Compliance ......................... 250
13.1.7. End of Life / Product Recycling ................................................................ 250

viii
List of Figures
1.1. 2.5” HDD System Component Overview ......................................................................... 11
1.2. 3.5” HDD System Component Overview ......................................................................... 12
1.3. 2.5” HDD System Front View ......................................................................................... 13
1.4. 3.5” HDD System Front View ......................................................................................... 13
1.5. 3.5” HDD Front Control Panel ........................................................................................ 13
1.6. 2.5” HDD Front Control Panel ........................................................................................ 14
1.7. System Rear View ......................................................................................................... 14
1.8. System Rear I/O ........................................................................................................... 15
1.9. PSU to Mainboard Module Description ........................................................................... 15
1.10. 2.5” System Front Control Panel LEDs ......................................................................... 16
1.11. 3.5” System Front Control Panel LEDs ......................................................................... 16
1.12. RJ45 LAN Connector ................................................................................................... 17
2.1. Opening the Top Cover ................................................................................................. 21
2.2. Closing the Top Cover ................................................................................................... 22
2.3. Opening the 2.5” Hard Drive Tray Handle ....................................................................... 23
2.4. Removing a 2.5” Hard Drive Tray .................................................................................. 23
2.5. Removing a 2.5” HDD from the Tray .............................................................................. 24
2.6. Installing a 2.5” HDD into a Tray .................................................................................... 24
2.7. Installing a 2.5” HDD in the System ............................................................................... 24
2.8. Opening the Hard Drive Tray Handle ............................................................................. 25
2.9. Removing the 3.5” Hard Drive Tray ................................................................................ 25
2.10. Removing a 3.5” HDD from the Tray ............................................................................ 26
2.11. Installing an HDD into a Tray ....................................................................................... 26
2.12. Installing a 3.5” HDD on the Tray ................................................................................. 27
2.13. Installing a 3.5” HDD on the Tray ................................................................................. 27
2.14. Opening the PSU Handle ............................................................................................ 28
2.15. Removing the PSU ...................................................................................................... 28
2.16. Installing a Power Supply Unit ..................................................................................... 29
2.17. Removing the Heat Sink .............................................................................................. 30
2.18. Installing the Heat Sink ................................................................................................ 31
2.19. Releasing the Right Processor Locking Lever ............................................................... 32
2.20. Releasing the Left Processor Locking Lever ................................................................. 33
2.21. Opening the Processor Cover ...................................................................................... 34
2.22. Removing the Processor .............................................................................................. 35
2.23. Installing the Processor ................................................................................................ 35
2.24. Closing the Processor Cover ........................................................................................ 36
2.25. Removing Memory Modules ......................................................................................... 37
2.26. Installing Memory Modules ........................................................................................... 38
2.27. Removing the PCI-E Riser Assembly (1 of 2) ................................................................ 39
2.28. Removing the PCI-E Riser Assembly (2 of 2) ................................................................ 39
2.29. Installing the PCI-E Riser Assembly (1 of 2) ................................................................. 40
2.30. Installing the PCI-E Riser Assembly (2 of 2) ................................................................. 40
2.31. Removing the PCI-E Card (1 of 2) ............................................................................... 41
2.32. Removing the PCI-E Card (2 of 2) ............................................................................... 41
2.33. Installing the PCI-E Expansion Card (1 of 2) ................................................................. 42
2.34. Installing the PCI-E Expansion Card (2 of 2) ................................................................. 42
2.35. Removing the Air Duct ................................................................................................. 43
2.36. Installing the Air Duct .................................................................................................. 44
2.37. Disconnecting Fan Cables from Expander Board ........................................................... 45

Netberg Demos R130 M2 server
ix
2.38. Removing the Fan Module Assembly Screws ................................................................ 45
2.39. Installing Fan Module Assembly Screws ....................................................................... 46
2.40. Connecting the Fan Assembly Cables .......................................................................... 47
2.41. Expander BP Connectors ............................................................................................. 48
2.42. Removing the Expander Backplane Screws .................................................................. 49
2.43. Removing the Expander Backplane .............................................................................. 49
2.44. Installing the Expander Backplane ................................................................................ 50
2.45. Installing the Expander Backplane Screws .................................................................... 51
2.46. HDD Backplane Connectors ......................................................................................... 52
2.47. Removing the 2.5” HDD Backplane Screws .................................................................. 52
2.48. Installing the 2.5” HDD Backplane ................................................................................ 53
2.49. Installing the 2.5” HDD Backplane Screws .................................................................... 54
2.50. Power Connector ......................................................................................................... 54
2.51. HDD BP Connectors .................................................................................................... 55
2.52. Removing the 3.5” HDD Backplane Screws .................................................................. 55
2.53. Removing the 3.5” HDD Backplane .............................................................................. 56
2.54. Aligning the 3.5” HDD Backplane ................................................................................. 56
2.55. Installing the 3.5” HDD Backplane Screws .................................................................... 57
2.56. HDD BP Connectors .................................................................................................... 57
3.1. Main Screen .................................................................................................................. 66
3.2. Advanced Screen .......................................................................................................... 68
3.3. PCI Subsystem Settings Screen .................................................................................... 69
3.4. PCI Express Settings Screen ......................................................................................... 70
3.5. Trusted Computing Screen ............................................................................................ 71
3.6. WHEA Configuration Screen .......................................................................................... 72
3.7. Processor Configuration Screen ..................................................................................... 73
3.8. Socket 0 CPU Information Screen .................................................................................. 75
3.9. CPU Power Management Configuration Screen .............................................................. 76
3.10. Runtime Error Logging Screen ..................................................................................... 78
3.11. ATA Controller Configuration Screen ............................................................................ 79
3.12. SAS Controller Configuration Screen ............................................................................ 80
3.13. Intel TXT(LT-SX) Configuration Screen ......................................................................... 81
3.14. USB Configuration Screen ........................................................................................... 82
3.15. Super I/O Configuration Screen .................................................................................... 84
3.16. Serial Port 0 Configuration Screen ............................................................................... 85
3.17. Onboard Device Configuration Screen .......................................................................... 86
3.18. Console Redirection Screen ......................................................................................... 87
3.19. Console Redirection Settings Screen ............................................................................ 88
3.20. Chipset Screen ............................................................................................................ 90
3.21. North Bridge Configuration Screen ............................................................................... 91
3.22. Intel(R) VT-d Configuration Screen ............................................................................... 92
3.23. South Bridge Configuration Screen ............................................................................... 93
3.24. USB Configuration Screen ........................................................................................... 94
3.25. ME Subsystem Screen ................................................................................................ 95
3.26. Server Management Configuration Screen .................................................................... 97
3.27. System Event Log Screen ........................................................................................... 99
3.28. FRU Information Screen ............................................................................................ 100
3.29. BMC Network Configuration Screen ............................................................................ 101
3.30. Boot Option Screen ................................................................................................... 103
3.31. Security Configuration Screen .................................................................................... 106
3.32. Exit Screen ............................................................................................................... 107

Netberg Demos R130 M2 server
x
4.1. Recovery Page ............................................................................................................ 113
4.2. BIOS Recovery Completed .......................................................................................... 114
8.1. Login Web Page ......................................................................................................... 158
8.2. Main Web Page .......................................................................................................... 159
8.3. Dashboard .................................................................................................................. 160
8.4. Server Information – Menu .......................................................................................... 162
8.5. FRU Information Page ................................................................................................. 163
8.6. Component Information Page ....................................................................................... 164
8.7. Server Identify Page .................................................................................................... 166
8.8. Server Health – Menu ................................................................................................. 167
8.9. Sensor Readings Page ................................................................................................ 167
8.10. Widget Window ......................................................................................................... 168
8.11. Event Log Page ......................................................................................................... 169
8.12. Configuration Group Menu ......................................................................................... 170
8.13. Active Directory Settings Page ................................................................................... 170
8.14. Add Role group Page ................................................................................................ 172
8.15. DNS Server Settings Page ......................................................................................... 173
8.16. LDAP Settings Page .................................................................................................. 176
8.17. Advanced LDAP Settings ........................................................................................... 176
8.18. Add Role group Page ................................................................................................ 177
8.19. Mouse Mode Settings Page ....................................................................................... 178
8.20. Network Settings Page .............................................................................................. 179
8.21. PEF Management – Event Filter ................................................................................. 182
8.22. Modify Event Filter Entry Page ................................................................................... 183
8.23. PEF Management – Alert Policy ................................................................................. 184
8.24. Add Alert Policy Entry Page ....................................................................................... 185
8.25. PEF Management LAN Destination ............................................................................ 186
8.26. Add LAN Destination entry Page ................................................................................ 187
8.27. RADIUS Settings Page .............................................................................................. 188
8.28. Remote Session ........................................................................................................ 189
8.29. SMTP Settings Page ................................................................................................. 190
8.30. SOL Settings Page .................................................................................................... 193
8.31. SSL Certificate Configuration – Upload SSL ................................................................ 194
8.32. SSL Certificate Configuration – Generate SSL ............................................................ 194
8.33. SSL Certificate Configuration – View SSL ................................................................... 196
8.34. User Management ..................................................................................................... 198
8.35. Add User Page .......................................................................................................... 199
8.36. Modify User Page ...................................................................................................... 201
8.37. Configure Virtual Media Devices ................................................................................. 201
8.38. Configure Virtual Media Devices ................................................................................. 203
8.39. Virtual Media ............................................................................................................. 207
8.40. Video Record Settings Page ...................................................................................... 209
8.41. Power Control and Status Page ................................................................................. 210
8.42. Maintenance Menu .................................................................................................... 212
8.43. Firmware Update Page .............................................................................................. 213
8.44. Restore Factory Defaults Page ................................................................................... 214
8.45. BIOS update ............................................................................................................. 214
9.1. Disassembling the Rails ............................................................................................... 219
9.2. Installing the Inner Rail ................................................................................................ 219
9.3. Securing the Inner Rail ................................................................................................ 220
9.4. Installing the Outer Rail ............................................................................................... 221

xii
List of Tables
1.1. System specifications ...................................................................................................... 8
1.2. Component Overview .................................................................................................... 12
1.3. Front Panel View ........................................................................................................... 13
1.4. Front Control Panel Definition ........................................................................................ 14
1.5. System Rear View ......................................................................................................... 14
1.6. System Rear I/O Definition ............................................................................................ 15
1.7. Front Control Panel LED Behavior ................................................................................. 16
1.8. RJ45 LED Description ................................................................................................... 17
1.9. BMC Management Port LED Behaviour .......................................................................... 17
1.10. HDD LED Status Behavior ........................................................................................... 17
3.1. BIOS Setup Page Layout ............................................................................................... 60
3.2. BIOS Setup: Keyboard Command .................................................................................. 62
3.3. Main Screen Fields ....................................................................................................... 66
3.4. Advanced Screen Fields ................................................................................................ 68
3.5. PCI Subsystem Settings Screen Fields ........................................................................... 69
3.6. PCI Express Settings Fields ........................................................................................... 70
3.7. Trusted Computing Screen Fields .................................................................................. 71
3.8. WHEA Configuration Fields ............................................................................................ 72
3.9. Processor Configuration Fields ....................................................................................... 73
3.10. Socket 0 CPU Information Fields ................................................................................. 75
3.11. CPU Power Mgmt Configuration Fields ......................................................................... 76
3.12. Runtime Error Logging Fields ....................................................................................... 78
3.13. SAS Configuration Fields ............................................................................................. 80
3.14. Intel TXT (LT-SX) Configuration Fields ......................................................................... 81
3.15. USB Configuration Fields ............................................................................................. 83
3.16. Super I/O Configuration Fields ..................................................................................... 84
3.17. Serial Port 0 Configuration Fields ................................................................................. 85
3.18. Onboard Device Configuration Fields ............................................................................ 86
3.19. Console Redirection Fields .......................................................................................... 87
3.20. Console Redirection Settings Fields ............................................................................. 88
3.21. Chipset Fields ............................................................................................................. 90
3.22. North Bridge Configuration Fields ................................................................................. 91
3.23. Intel® VT-d Fields. ...................................................................................................... 92
3.24. South Bridge Configuration Fields ................................................................................ 93
3.25. USB Configuration Fields ............................................................................................. 94
3.26. ME Subsystem Fields .................................................................................................. 95
3.27. Server Management Configuration Fields ..................................................................... 97
3.28. System Event Log Fields ............................................................................................. 99
3.29. FRU Information Fields .............................................................................................. 100
3.30. BMC Network Configuration Fields ............................................................................. 101
3.31. Boot Option Fields ..................................................................................................... 103
3.32. Security Configuration Fields ...................................................................................... 106
3.33. Exit Fields ................................................................................................................. 107
5.1. Keystroke mappings .................................................................................................... 118
5.2. Checkpoint Ranges ..................................................................................................... 122
5.3. SEC Phase ................................................................................................................. 123
5.4. PEI Phase ................................................................................................................... 123
5.5. DXE Phase ................................................................................................................. 125
5.6. PEI Beep Codes ......................................................................................................... 128

Netberg Demos R130 M2 server
xiii
5.7. DXE Beep Codes ........................................................................................................ 128
5.8. ACPI/ASL Checkpoints ................................................................................................ 129
5.9. OEM Reserved Checkpoint Ranges ............................................................................. 129
6.1. Status LED, ID LED, and Heartbeat LED ...................................................................... 134
6.2. Status LED Activity ...................................................................................................... 134
6.3. IPMI Device Global Commands .................................................................................... 144
6.4. Device and Messaging Commands .............................................................................. 144
6.5. Watchdog Timer Commands ........................................................................................ 146
6.6. Chassis Commands ..................................................................................................... 146
6.7. Event Commands ........................................................................................................ 147
6.8. SEL Commands .......................................................................................................... 147
6.9. SDR Repository Commands ........................................................................................ 148
6.10. FRU Inventory Device Commands .............................................................................. 149
6.11. Sensor Device Commands ......................................................................................... 149
6.12. LAN Commands ........................................................................................................ 150
6.13. SOL Command .......................................................................................................... 150
6.14. PEF/PET Alerting Commands .................................................................................... 150
6.15. OEM Command ......................................................................................................... 151
8.1. Default Username and Password ................................................................................. 158
8.2. Main Web Page .......................................................................................................... 159
8.3. Device Information Page .............................................................................................. 160
8.4. Network Information ..................................................................................................... 161
8.5. Basic Information ......................................................................................................... 163
8.6. Component Information Page ....................................................................................... 165
8.7. Server Identify Page .................................................................................................... 166
8.8. Event Log Category ..................................................................................................... 169
8.9. DNS Server Settings Page .......................................................................................... 174
8.10. Mouse Mode Settings Page ....................................................................................... 178
8.11. Network Settings Page .............................................................................................. 180
8.12. PET Management - Event Filter ................................................................................. 182
8.13. PEF Management - Alert Policy ................................................................................. 184
8.14. RADIUS Settings Page .............................................................................................. 188
8.15. Remote Session Settings Page .................................................................................. 189
8.16. SMTP Settings Page ................................................................................................. 191
8.17. SOL Settings Page .................................................................................................... 193
8.18. SSL Certificate Configuration - Upload SSL ................................................................ 194
8.19. SSL Certificate Configuration - Generate SSL ............................................................. 195
8.20. SSL Certificate Configuration – View SSL ................................................................... 196
8.21. User Management Page ............................................................................................ 198
8.22. Configure Virtual Media Devices ................................................................................. 201
8.23. Video ........................................................................................................................ 206
8.24. Keyboard ................................................................................................................... 206
8.25. Virtual Media ............................................................................................................. 207
8.26. Keyboard Layout ....................................................................................................... 208
8.27. Video Record ............................................................................................................ 208
8.28. Power ....................................................................................................................... 209
8.29. Server Power Control ................................................................................................ 210
8.30. User Privilege ............................................................................................................ 216
13.1. Product Regulatory Compliance Markings ................................................................... 246

1
Chapter 1. Netberg Demos R130 M2
server

Netberg Demos R130 M2 server
2
1.1. Conventions
Several different typographic conventions are used throughout this manual. Refer to the following
examples for common usage.
Bold type face denotes menu items, buttons and application names.
Italic type face denotes references to other sections, and the names of the folders, menus, pro-
grams, and files.
<Enter> type face denotes keyboard keys.
Warning information appears before the text it references and should not be ignored
as the content may prevent damage to the device.
CAUTIONS APPEAR BEFORE THE TEXT IT REFERENCES, SIMILAR TO NOTES
AND WARNINGS. CAUTIONS, HOWEVER, APPEAR IN CAPITAL LETTERS AND
CONTAIN VITAL HEALTH AND SAFETY INFORMATION.
Indicates information that is important to know for the proper completion of a proce-
dure, choice of an option, or completing a task.
Highlights general or useful information and tips.

Netberg Demos R130 M2 server
3
1.2. Acronyms
A/D Analog to Digital
ACPI Advanced Configuration and Power Interface
ASF Alerting Standard Forum
Asserted Active-high (positive true) signals are asserted when in the high electrical
state (near power potential). Active-low (negative true) signals are asserted
when in the low electrical state (near ground potential).
BIOS Basic Input/Output System
BIST Built-In Self Test
BMC At the heart of the IPMI architecture is a microcontroller called the Baseboard
management controller (BMC)
Bridge Circuitry connecting one computer bus to another, allowing an agent on one
to access the other
BSP Bootstrap processor
Byte 8-bit quantity
CLI Command Line Interface
CMOS In terms of this specification, this describes the PC-AT compatible region of
battery-backed 128 bytes of memory, which normally resides on the base-
board
CPU Central Processing Unit
Deasserted A signal is deasserted when in the inactive state. Active-low signal names
have “_L” appended to the end of the signal mnemonic. Active-high signal
names have no “_L” suffix. To reduce confusion when referring to active-high
and active-low signals, the terms one/zero, high/low, and true/false are not
used when describing signal states.
DTC Data Transfer Controller
EEPROM Electrically Erasable Programmable Read-Only Memory
EMP Emergency Management Port
FRU Field Replaceable Unit
GB 1024 MB.
GPIO General Purpose Input/Out
HSC Hot-Swap Controller
Hz Hertz (1 cycle/second)
I2C Inter-Integrated Circuit bus
IANA Internet Assigned Numbers Authority
IBF Input buffer
ICH I/O Controller Hub
ICMB Intelligent Chassis Management Bus

Netberg Demos R130 M2 server
4
IERR Internal Error
IP Internet Protocol
IPMB Intelligent Platform Management Bus
IPMI Intelligent Platform Management Interface
ITP In-Target Probe
KB 1024 bytes.
KCS Keyboard Controller Style
KVM Keyboard, Video, Mouse
LAN Local Area Network
LCD Liquid Crystal Display
LCT Lower Critical Threshold
LED Light Emitting Diode
LNCT Lower Non-Critical Threshold
LNRT Lower Non-Recoverable Threshold
LPC Low Pin Count
LSI Large Scale Integration
LUN Logical Unit Number
MAC Media Access Control
MB 1024 KB
MD2 Message Digest 2 – Hashing Algorithm
MD5 Message Digest 5 – Hashing Algorithm – Higher Security
Ms Milliseconds
Mux Multiplexer
NIC Network Interface Card
NMI Nonmaskable Interrupt
NM Node Management
OBF Output buffer
OEM Original Equipment Manufacturer
Ohm Unit of electrical resistance
PDB Power Distribution Board
PEF Platform Event Filtering
PEP Platform Event Paging
PERR Parity Error
POH Power-On Hours
POST Power-On Self Test
PWM Pulse Width Modulation

Netberg Demos R130 M2 server
5
RAC Remote Access Card
RAM Random Access Memory
RMCP Remote Management Control Protocol
ROM Read Only Memory
RTC Real-Time Clock. Component of the chipset on the baseboard.
RTOS Real Time Operation System
SCI Serial Communication Interface
SDC SCSI Daughter Card
SDR Sensor Data Record
SEEPROM Serial Electrically Erasable Programmable Read-Only Memory
SEL System Event Log
SERR System Error
SMBus A two-wire interface based on the I2C protocol. The SMBus is a low-speed
bus that provides positive addressing for devices, as well as bus arbitration
SMI Server Management Interrupt. SMI is the highest priority nonmaskable inter-
rupt
SMM Server Management Mode
SMS Server Management Software
SNMP Simple Network Management Protocol
SOL Serial Over LAN
UART Universal Asynchronous Receiver/Transmitter
UCT Upper Critical Threshold
UDP User Datagram Protocol
UNCT Upper Non-Critical Threshold
UNRT Upper Non-Recoverable Threshold
WDT Watchdog Timer
Word 16-bit quantity

Netberg Demos R130 M2 server
6
1.3. Safety Information
1.3.1. Important Safety Instructions
Read all caution and safety statements in this document before performing any of the instructions.
Warnings
Heed safety instructions: Before working with the server, whether using this manual or any other
resource as a reference, pay close attention to the safety instructions. Adhere to the assembly in-
structions in this manual to ensure and maintain compliance with existing product certifications and
approvals. Use only the described, regulated components specified in this manual. Use of other
products / components will void the UL listing and other regulatory approvals of the product and
will most likely result in non-compliance with product regulations in the region(s) in which the prod-
uct is sold.
System power on/off: The power button DOES NOT turn off the system AC power. To remove
power from system, you must unplug the AC power cord from the wall outlet. Make sure the AC
power cord is unplugged before opening the chassis, adding, or removing any components.
Hazardous conditions, devices and cables: Hazardous electrical conditions may be present on
power, telephone, and communication cables. Turn off the server and disconnect the power cord,
telecommunications systems, networks, and modems attached to the server before opening it.
Otherwise, personal injury or equipment damage can result.
Electrostatic discharge (ESD) and ESD protection: ESD can damage drives, boards, and other
parts. We recommend that you perform all procedures in this chapter only at an ESD workstation.
If one is not available, provide some ESD protection by wearing an antistatic wrist strap attached
to chassis ground any unpainted metal surface on the server when handling parts.
ESD and handling boards: Always handle boards carefully. They can be extremely sensitive to
electrostatic discharge (ESD). Hold boards only by their edges. After removing a board from its
protective wrapper or from the server, place the board component side up on a grounded, static
free surface. Use a conductive foam pad if available but not the board wrapper. Do not slide board
over any surface.
Installing or removing jumpers: A jumper is a small plastic encased conductor that slips over two
jumper pins. Some jumpers have a small tab on top that can be gripped with fingertips or with a
pair of fine needle nosed pliers. If the jumpers do not have such a tab, take care when using nee-
dle nosed pliers to remove or install a jumper; grip the narrow sides of the jumper with the pliers,
never the wide sides. Gripping the wide sides can damage the contacts inside the jumper, caus-
ing intermittent problems with the function controlled by that jumper. Take care to grip with, but not
squeeze, the pliers or other tool used to remove a jumper, or the pins on the board may bend or
break.

Netberg Demos R130 M2 server
7
1.4. Disclaimer
The information in this document is subject to change without notice. The manufacturer makes no
representations or warranties with respect to the contents hereof and specifically disclaims any im-
plied warranties of merchantability or fitness for any particular purpose. Furthermore, the manufac-
turer reserves the right to revise this publication and to make changes from time to time in the con-
tent hereof without obligation of the manufacturer to notify any person of such revision or changes.
For the latest information and updates please refer to [email protected]
[mailto:[email protected]]
All the illustrations in this technical guide are for reference only and are subject to change without
prior notice.
Table of contents
Other Netberg Server manuals
Popular Server manuals by other brands

Dell
Dell PowerEdge T110 II Getting started with

HP
HP ProLiant DL380 Maintenance and service guide

Fujitsu
Fujitsu PRIMERGY TX600 S2 Options guide

Digital Watchdog
Digital Watchdog Blackjack Tower DW-BJMT31 T/LX Series quick start guide

Digital Equipment
Digital Equipment Prioris XL 6000 Series installation guide

Dell
Dell poweredge VRTX owner's manual