netsys NH-310H User manual

H
H
H
P
P
P
N
N
N
A
A
A
3
3
3
.
.
.
1
1
1
E
E
E
O
O
O
C
C
C
M
M
M
a
a
a
n
n
n
a
a
a
g
g
g
e
e
e
d
d
d
C
C
C
o
o
o
n
n
n
c
c
c
e
e
e
n
n
n
t
t
t
r
r
r
a
a
a
t
t
t
o
o
o
r
r
r
a
a
a
n
n
n
d
d
d
B
B
Br
r
ri
i
id
d
dg
g
ge
e
e
N
N
NH
H
H-
-
-3
3
31
1
10
0
0H
H
H/
/
/S
S
S
U
U
US
S
SE
E
ER
R
R’
’
’S
S
S
M
M
MA
A
AN
N
NU
U
UA
A
AL
L
L

NH-310H/S HPNA3.1 EOC Managed Concentrator and Bridge USER’S MANUAL er.D1
1
Copyright
Copyright © 2011 by National Enhance Technology Corp. All rights reserved.
Trademarks
NETSYS is a trademar of National Enhance Technology Corp.
Other brand and product names are registered trademar s or trademar s of their respective holders.
Legal Disclaimer
The information given in this document shall in no event be regarded as a guarantee of conditions or characteristics. With respect
to any examples or hints given herein, any typical values stated herein and/or any information regarding the application of the
device, National Enhance Technology Corp. hereby disclaims any and all warranties and liabilities of any ind, including without
limitation warranties of non-infringement of intellectual property rights of any third party.
Statement of Conditions
In the interest of improving internal design, operational function, and/or reliability, NETSYS reserves the right to ma e changes to
the products described in this document without notice. NETSYS does not assume any liability that may occur due to the use or
application of the product(s) or circuit layout(s) described herein.
Maximum signal rate derived from IEEE Standard specifications. Actual data throughput will vary. Networ conditions and
environmental factors, including volume of networ traffic, building materials and construction, and networ overhead, lower actual
data throughput rate. Netsys does not warrant that the hardware will wor properly in all environments and applications, and ma es
no warranty and representation, either implied or expressed, with respect to the quality, performance, merchantability, or fitness for
a particular purpose. Ma e sure you follow in line with the environmental conditions to use this product.

NH-310H/S HPNA3.1 EOC Managed Concentrator and Bridge USER’S MANUAL er.D1
2
Foreword
Attention:
Be sure to read this manual carefully before using this product. Especially Legal Disclaimer, Statement
of Conditions and Safety Warnings.
Netsys’ NH-310H and NH-310S are the latest technological innovation of HomePNA3.1 Ethernet over coaxial managed concentrator
and bridged (client) respectively. NH-310H EOC managed concentrator is designed to connect with NH-310S MDU bridged for MDU
and MTU applications that leverage the two most popular networ connections for home use: 10/100Mbps Ethernet connection and
coaxial cable connection.
It is a norm that MDU and MTU are equipped with wired networ that simply transfer small files and shared applications, but the need
for triple play services li e transferring large multimedia files such as music, video, photo and deliver high speed VOIP data are ever
increasing.
This is why NH-310H/S is designed to be a cost effective MDU and MTU solution. With plug & play, this simply eliminates the pain in
modification and high infrastructure cost. With the data transmission up to 200Mbps and lin establish under -145dBm/Hz noise floor,
it meets the growing demand for high speed multimedia services. Most importantly, with MDU and MTU applications, it allows
networ ing for any locations such as buildings, apartments, hotels, resorts, sports center and other places that need a high
bandwidth networ .
Caution:
The NH-310H and NH-310S are for indoor applications only. This product does not have waterproof protection, please do not use
in outdoor applications.

NH-310H/S HPNA3.1 EOC Managed Concentrator and Bridge USER’S MANUAL er.D1
3
Safety Warnings
For your safety, be sure to read and follow all warning notices and instructions before using the device.
DO NOT open the device or unit. Opening or removing covers can expose you to dangerous high voltage points or other
ris s. ONLY qualified service personnel can service the device. Please contact your vendor for further information.
Use ONLY the dedicated power supply for your device. Connect the power to the right supply voltage (110V AC used for
North America and 230V AC used for Europe, NH-310H/S supports 12 VDC power input).
Place connecting cables carefully so that no one will step on them or stumble over them. DO NOT allow anything to rest on
the power cord and do NOT locate the product where anyone can wor on the power cord.
DO NOT install nor use your device during a thunderstorm. There may be a remote ris of electric shoc from lightning.
DO NOT expose your device to dampness, dust or corrosive liquids.
DO NOT use this product near water, for example, in a wet basement or near a swimming pool.
Connect ONLY suitable accessories to the device.
Make sure to connect the cables to the correct ports.
DO NOT obstruct the device ventilation slots, as insufficient air flow may harm your device.
DO NOT place items on the device.
DO NOT use the device for outdoor applications directly, and ma e sure all the connections are indoors or have waterproof
protection place.
Be careful when unplugging the power, because it may produce spar s.
Kee the device and all its parts and accessories out of the reach of children.
Clean the device using a soft and dry cloth rather than liquid or atomizers. Power off the equipment before cleaning it.
This product is recyclable. Dispose of it properly.

NH-310H/S HPNA3.1 EOC Managed Concentrator and Bridge USER’S MANUAL er.D1
4
Table of Contents
COPYRIGHT ........................................................................................................................................................ 1
FOREWORD ........................................................................................................................................................ 2
SAFETY WARNINGS ........................................................................................................................................... 3
CHAPTER 1. UNPACKING INFORMATION......................................................................................................... 7
1.1 C
HECK
L
IST
.............................................................................................................................................................................7
CHAPTER 2. HARDWARE DESCRIPTION..........................................................................................................
2.1
F
RONT
P
ANEL
...............................................................................................................................................................................8
2.2
F
RONT
I
NDICATORS
.......................................................................................................................................................................9
2.3
R
EAR
P
ANEL
...............................................................................................................................................................................11
CHAPTER 3. INSTALLATION ............................................................................................................................ 13
3.1
H
ARDWARE
I
NSTALLATION
............................................................................................................................................................13
3.2
P
RE
-
INSTALLATION
R
EQUIREMENTS
..............................................................................................................................................13
3.3
G
ENERAL
R
ULES
.........................................................................................................................................................................14
3.4
HCNA
C
ONNECTIONS
.................................................................................................................................................................15
CHAPTER 4. CONFIGURE THE NH-310H VIA WEB BROWSER...................................................................... 1
4.1
L
OGIN
.........................................................................................................................................................................................18
4.2
S
ELECT THE
M
ENU
L
EVEL
............................................................................................................................................................19
4.3
S
ELECT
“SYSTEM” ....................................................................................................................................................................20

NH-310H/S HPNA3.1 EOC Managed Concentrator and Bridge USER’S MANUAL er.D1
5
4.3.1 Administrator Setting..........................................................................................................................................................21
4.3.2 System Time Zone .............................................................................................................................................................22
4.3.3 System Time ......................................................................................................................................................................23
4.3.4 Firmware Upgrade .............................................................................................................................................................24
4.3.5 Reboot................................................................................................................................................................................25
4.3.6 Reset System.....................................................................................................................................................................26
4.3.7 Version Info........................................................................................................................................................................27
4.3.8 SNMP.................................................................................................................................................................................28
4.4
S
ELECT
”LAN” ............................................................................................................................................................................30
4.4.1 LAN Settings ......................................................................................................................................................................31
4.4.2 LAN Switch Port Setting.....................................................................................................................................................32
4.4.3 LAN Port Status .................................................................................................................................................................33
4.5
S
ELECT
”ROUTE”.......................................................................................................................................................................34
4.5.1Static Routing......................................................................................................................................................................35
4.5.2 Routing Table List ..............................................................................................................................................................37
4.6
S
ELECT
”HPNA” .........................................................................................................................................................................38
4.6.1 Device Info./Test ................................................................................................................................................................39
4.6.1.1 Concentrator Read Packet Counter .............................................................................................................................................41
4.6.1.2 End Point Net Interface Test........................................................................................................................................................42
4.6.1.3 End Point Read Packet Counter ..................................................................................................................................................44
4.6.2 Device Control....................................................................................................................................................................45
4.6.2.1 EOC driver Up rade for Concentrator..........................................................................................................................................47
4.6.2.2 HPNA driver Up rade and user speed control for Brid es ...........................................................................................................49
4.6.2.3 Reboot for Brid es.......................................................................................................................................................................51

NH-310H/S HPNA3.1 EOC Managed Concentrator and Bridge USER’S MANUAL er.D1
6
4.6.2.4 Add User for Brid es ...................................................................................................................................................................53
4.6.3 User List.............................................................................................................................................................................57
CHAPTER 5. CONFIGURE THE NH-310H VIA CONSOLE................................................................................ 60
5.1
S
ETUP ON
H
YPER
T
ERMINAL
.........................................................................................................................................................60
5.2
R
ESET THE SYSTEM TO DEFAULT CONFIGURATION
..........................................................................................................................60
5.3
TFTP
P
ROTOCOL FOR FIRMWARE UPGRADE
..................................................................................................................................61
APPENDIX A: CABLE REQUIREMENTS ........................................................................................................... 66
APPENDIX B: PRODUCT SPECIFICATION....................................................................................................... 69
APPENDIX C: TROUBLESHOOTING ................................................................................................................ 72
APPENDIX D: COMPLIANCE AND SAFETY INFORMATION............................................................................ 7
APPENDIX E: HOME NETWORKING INSTALLATION GUIDE .......................................................................... 1
APPENDIX F: MDU INSTALLATION GUIDE ................................................................................................... 91
WARRANTY ..................................................................................................................................................... 101
CHINESE SJ/T 11364-2006.............................................................................................................................. 102

NH-310H/S HPNA3.1 EOC Managed Concentrator and Bridge USER’S MANUAL er.D1
7
Chapter 1. Unpacking Information
1.1 Check List
Than you for choosing Netsys NH-310H/S. Before installing the router, please verify the contents inside the pac age.
Package Contents:
NH-310H or NH-310S Device
4 x rubber foot (NH-310H pre-installed on the bottom, and you can find the rubber foot inside the inner box right
side of the NH-310S)
1 x AC to DC
1 V
Power Adapter
1 x RJ-45 Cable
Notes:
1.
Please inform your dealer immediately for any missing or damaged parts. If possible, retain the carton including the
original pac ing materials. Use them to repac the unit in case there is a need to return for repair.
2. If the product has any issue, please contact your local vendor.
3. Do not use sub-standard power supply. Before connecting the power supply to the device, be sure to chec
compliance with the specifications. The NH-310H/S supports 12 VDC power input.
4. The power supply included in the pac age is commercial-grade. Do not use in industrial-grade applications.
5. Please loo for the QR code on the bottom of the product, the user can launch the QR code scanning program to
scan and download the user’s manual electronic format file.

NH-310H/S HPNA3.1 EOC Managed Concentrator and Bridge USER’S MANUAL er.D1
8
Chapter 2. Hardware Description
This chapter describes the important parts of the device. It features the front indicators and rear connectors.
NH-31 H Outward
NH-31 S Outward
.1 Front Panel
The front panel provides a simple interface monitoring of the concentrator/bridged. (Figure 2.1)
Figure 2.1 NH-310H and NH-310S Front Panel

NH-310H/S HPNA3.1 EOC Managed Concentrator and Bridge USER’S MANUAL er.D1
9
. Front Indicators
The NH-310H has Six LED indicators. The following Table shows the description. (Table 2-1)
Table 2-1 LED Indicators Description and Operation
LEDs Color Status
Descriptions
On The HCNA is receiving the power and also functioning properly
Power Green
Off The HCNA is not ready or has malfunctioned
On The LAN port is connected to Ethernet devices
Blin ing The HCNA is transferring data
LAN1
(Ethernet LED) Green
Off The LAN port is not connected to any Ethernet devices
On The LAN port is connected to Ethernet devices
Blin ing The HCNA is transferring data
LAN2
(Ethernet LED) Green
Off The LAN port is not connected to any Ethernet devices
On The LAN port is connected to Ethernet devices
Blin ing The HCNA is transferring data
LAN3
(Ethernet LED) Green
Off The LAN port is not connected to any Ethernet devices
On The LAN port is connected to Ethernet devices
Blin ing The HCNA is transferring data
LAN4
(Ethernet LED) Green
Off The LAN port is not connected to any Ethernet devices
On The HCNA is lin to another HCNA end point device
HCNA
(HCNA LED) Green
Blin ing The HCNA is active and it is transferring data
The NH-310S has Six LED indicators. The following Table shows the description. (Table 2-2)

NH-310H/S HPNA3.1 EOC Managed Concentrator and Bridge USER’S MANUAL er.D1
10
Table 2-2 LED Indicators Description and Operation
LEDs Color Status Descri tions
On The HCNA is receiving the power and also functioning properly
Power Green
Off The HCNA is not ready or has malfunctioned
On The LAN port is connected to Ethernet devices
Blin ing The HCNA is transferring data
LAN1
(Ethernet LED) Green
Off The LAN port is not connected to any Ethernet devices
On The LAN port is connected to Ethernet devices
Blin ing The HCNA is transferring data
LAN2
(Ethernet LED) Green
Off The LAN port is not connected to any Ethernet devices
On The HCNA is lin to another HCNA device
Blin ing The HCNA is active and it is transferring data
HCNA
(HCNA LED) Green
Off The HCNA is not connected
Green On Actual HCNA lin speed is ≧ 128MB
Green
Yellow
On
Actual HCNA lin speed is ≧ 64MB and < 128MB
Lin Quality
(HCNA LED)
Yellow
On
Actual HCNA lin speed is < 64MB

NH-310H/S HPNA3.1 EOC Managed Concentrator and Bridge USER’S MANUAL er.D1
11
.3 Rear Panel
The rear panel provides the physical connectors connected to the power adapter and any other networ device. (Figure 2.2)
Figure 2.2 Rear anel of the NH-310H
And the table shows the description. (Table 2-3)
Table 2-3 Connectors shown on the rear side of the device
Connectors Ty e Descri tion
HCNA F-type female
coaxial cable
For connecting HCNA port to another HCNA port with RG59 75ohm
coaxial cable.(HCNA port spectrum 12M - 44MHz)
TV F-type female
coaxial cable For connecting to TV or STB.(TV port spectrum 47M - 1GHz)
LAN1/LAN2/
LAN3/LAN4 RJ-45 For connecting to an Ethernet equipped device
Power Power Jac For connecting to 12V/1A power adapter

NH-310H/S HPNA3.1 EOC Managed Concentrator and Bridge USER’S MANUAL er.D1
12
The following figure shows the rear side of the NH-310S. (Figure 2.3)
And the table shows the description. (Table 2-4)
Figure 2.3 Rear anel of the NH-310S
Table 2-4 Connectors shown on the rear side of the device
Connectors
Ty e Descri tion
HCNA F-type female
coaxial cable
For connecting HCNA port to another HCNA port with RG59 75ohm cable.
(HCNA port spectrum 12M - 44MHz)
TV F-type female
coaxial cable For connecting to TV or STB. (TV port spectrum 47M - 1GHz)
LAN1/LAN2 RJ-45 For connecting to an Ethernet equipped device
Power Power Jac For connecting to 12V/1A power adapter, regarding the NH-310S power
specification you can refer to serial stic er of the bottom

NH-310H/S HPNA3.1 EOC Managed Concentrator and Bridge USER’S MANUAL er.D1
13
Chapter 3. Installation
3.1 Hardware Installation
This chapter describes how to install the device and establish the networ connections. The NH-310H/S may be installed
on any level surface (e.g. a table or shelf). However, please ta e note of the following minimum site requirements before
you begin. NH-310S must be stick the 4 rubber feet at the bottom and the NH-310H re-installed 4 rubber feet.
3. Pre-installation Requirements
Before you start the actual hardware installation, ma e sure you can provide the right operating environment, including
power requirements, sufficient physical space, and proximity to other networ devices that are to be connected. Verify
the following installation requirement:
• Power requirements: 12VDC (1A or above)
• The device should be located in a cool dry lace, with at least 10cm/4in of space at the front and bac for
ventilation.
• Place the device away from direct sunlight, heat sources, or areas with a high amount of electromagnetic
interference.
• If you
trying to setup basic connection between NH-310H and NH-310S, you need to add at least -10dB
attenuator (5M-850MHz).
• Chec if the networ cables and connectors needed for installation are available.
•
Avoid installing this device with radio amplifying stations nearby or transformer stations nearby.

NH-310H/S HPNA3.1 EOC Managed Concentrator and Bridge USER’S MANUAL er.D1
14
3.3 General Rules
Before ma ing any connections to the device, ta e note the following rules:
• Ethernet Port (RJ-45)
All networ connections to the concentrator Ethernet ports must be made using Category 5 UTP or above for 100
Mbps, Category 3, 4 UTP for 10Mbps.
No more than 100 meters of cabling maybe use between the MUX or HUB and an end node.
• HCNA Port (Coaxial)
All Home networ connections we recommend use RG59 75ohm coaxial cable and lin establish under -145dBm/Hz
noise floor.
• Di lexer / Multi-S litter
All Home networ connections could be use Diplexer or Multi-Splitter or use mix of them as you would li e to connect
an end point device.
Please choose according to different environments to different specifications of the Diplexer
(5M-45MHz, 47M-1GHz) or Multi-Splitter (5M-1Ghz).
• Attenuator
Establish the basic lin for NH-310H and NH-310S, please add a attenuator (at least -10 dB 5M-850MHz).
Diplexer Multi-Splitter Attenuator

NH-310H/S HPNA3.1 EOC Managed Concentrator and Bridge USER’S MANUAL er.D1
15
3.4 HCNA Connections
The device has been designed to operate on the coaxial cable installed in homes throughout the world. They utilized the
same cable and connectors commonly used for television.
The 2x Coaxial connector are used to connect to TV or coaxial wall soc et to another device that connect its RJ-45 to the
LAN card of another set of PC, noteboo , or other internet access device or coaxial connector to TV or set top box.
The device’s coaxial connector must support the transmission of data up to 200Mbps across the existing coaxial cable
and lin establish under -145dBm/Hz noise floor. But ma e sure that the connector is inserted properly and loc .
Ethernet cable used must conform to FCC standard to ensure data integrity and it should not exceed 100meters
(328feet).
The NH-310H EOC (Ethernet over coaxial) managed MDU concentrator can support up to 60(maximum) NH-310S
Bridges (Clients).
Notes:
1. Please refer to Appendix E: installation guide. There is introduced how to install HPNA3.1 device.
2. Each of the NH-310S can only be connected to 16 nodes (Mac Address).

NH-310H/S HPNA3.1 EOC Managed Concentrator and Bridge USER’S MANUAL er.D1
16
Figure 3.1 NH-310H/S connection diagram

NH-310H/S HPNA3.1 EOC Managed Concentrator and Bridge USER’S MANUAL er.D1
17
Figure 3.2 NH-310H/S connection diagram-2

NH-310H/S HPNA3.1 EOC Managed Concentrator and Bridge USER’S MANUAL er.D1
18
Chapter 4. Configure the NH-31 H Via Web Browser
The NH-310H provides a built-in HTML based management interface that allows configuration of the NH-310H via
Internet Browser. Best viewed using Chrome or Firefox browsers.
In order to use the web browser configure the device, you may need to allow:
• Web browser pop-up windows from your device. Web pop-up bloc ing is enabled by default in windows XP SP2
or above.
• Java Scripts. (Enabled by default)
• Java permissions. (Enabled by default)
Launch your web browser and input the default IP address “192.168.16.249” in the Web page.
Following section user can find default password.
4.1 Login
The default login password is “admin“. The password is changeable in Administrator Settings.
Figure 4.1 Login Password

NH-310H/S HPNA3.1 EOC Managed Concentrator and Bridge USER’S MANUAL er.D1
19
4. Select the Menu Level
There is an easy Setup for end users at the setup of NH-310H with SYSTEM, LAN, ROUTE, HPNA for more detail
configurations.
Figure 4.2 Select the Menu Level
This manual suits for next models
1
Table of contents
Other netsys Network Hardware manuals