netsys NVF-400L User manual

N
N
NV
V
VF
F
F-
-
-4
4
40
0
00
0
0L
L
L/
/
/R
R
R
4
4
4
B
B
Ba
a
an
n
nd
d
d
V
V
VD
D
DS
S
SL
L
L
C
C
CO
O
O/
/
/C
C
CP
P
PE
E
E
B
B
Br
r
ri
i
id
d
dg
g
ge
e
e
w
w
wi
i
it
t
th
h
h
4
4
4
P
P
Po
o
or
r
rt
t
ts
s
s
S
S
Sw
w
wi
i
it
t
tc
c
ch
h
h
U
U
U
S
S
S
E
E
E
R
R
R
’
’
’
S
S
S
M
M
M
A
A
A
N
N
N
U
U
U
A
A
A
L
L
L

NVF-400L/R 4 Band VDSL CO/CPE Bridge with 4 Ports Switch USER’S MANUAL Ver. A.5
1
Copyright
Copyright © 2011 by National Enhance Technology Corp. All rights reserved.
Trademarks
NETSYS is a trademark of National Enhance Technology Corp.
Other brand and product names are registered trademarks or trademarks of their respective holders.
Legal Disclaimer
The information given in this document shall in no event be regarded as a guarantee of conditions or characteristics. With respect
to any examples or hints given herein, any typical values stated herein and/or any information regarding the application of the
device, National Enhance Technology Corp. hereby disclaims any and all warranties and liabilities of any kind, including without
limitation warranties of non-infringement of intellectual property rights of any third party.
Statement of Conditions
In the interest of improving internal design, operational function, and/or reliability, NETSYS reserves the right to make changes to
the products described in this document without notice. NETSYS does not assume any liability that may occur due to the use or
application of the product(s) or circuit layout(s) described herein.
Maximum signal rate derived form IEEE Standard specifications.Actual data throughput will vary. Network conditions and
environmental factors, including volume of network traffic, building materials and construction, and network overhead lower actual
data throughput rate. Netsys does not warrant that the hardware will work properly in all environments and applications, and makes
no warranty and representation, either implied or expressed, with respect to the quality, performance, merchantability, or fitness
for a particular purpose. Make sure you follow in line with the environmental conditions to use this product.

NVF-400L/R 4 Band VDSL CO/CPE Bridge with 4 Ports Switch USER’S MANUAL Ver. A.5
2
Foreword: VDSL Point to Point Solution
The NVF-400L/R utilizes Ethernet to/from VDSL subscriber-site conversion-bridge and uses QAM-based 4-band VDSL technology
which supports high bandwidth up to 25Mbps symmetrical data service.
The NVF-400L also works with NVF-200R or NVF-400R, together to form a cost-effective solution for services such as remote
lecturing, telemedicine, video conferencing, Video-on-Demand (VoD), IP-TV, Internet access, and various high-speed data
applications.
The front panel provides LED indicators for system and interface status. The built-in POTS/ISDN splitter allows a standard POTS
phone or ISDN device to be connected. Full- or half-duplex mode of LAN operations is automatically sensed and configured. VDSL
link rates are configured by local IP DSLAMs over a fix speed and auto speed function.
Therefore, NVF-400L/R supports auto speed and plug & play operations in the subscriber site to form an ideal solution for delivering
cost effective, high performance broadband/multimedia services to Multi-Dwelling Units (MDU) and Multi-Tenant Units (MTU)
environments such as hotels, campus, hospitals and telecom.
Attention:
Be sure to read this manual carefully before using this product. Especially Legal Disclaimer, Statement
of Conditions and Safty Warnings.
Caution:
The NVF-400 is for indoor applications only. This product does not have waterproof protection. Do not use in harsh environments
(Over temperature range: 0°C ~ 50°C (32°F ~ 122°F)).

NVF-400L/R 4 Band VDSL CO/CPE Bridge with 4 Ports Switch USER’S MANUAL Ver. A.5
3
Safety Warnings
For your safety, be sure to read and follow all warning notices and instructions before using the device
DO NOT open the device or unit. Opening or removing covers can expose you to dangerous high voltage points or other
risks. ONLY qualified service personnel can service the device. Please contact your vendor for further information.
Use ONLY the dedicated power supply for your device. Connect the power cord or power adaptor to the right supply voltage
(110V AC in North America or 230V AC in Europe).
DO NOT use the device if the power supply is damaged as it might cause electrocution. If the power supply is damaged,
remove it from the power outlet. DO NOT attempt to repair the power supply. Contact your local vendor to order a new power
supply.
Place connecting cables carefully so that no one will step on them or stumble over them. DO NOT allow anything to rest on
the power cord and do NOT locate the product where anyone can work on the power cord.
DO NOT install nor use your device during a thunderstorm. There may be a remote risk of electric shock from lightning.
DO NOT expose your device to dampness, dust or corrosive liquids.
DO NOT use this product near water, for example, in a wet basement or near a swimming pool.
Connect ONLY suitable accessories to the device.
Make sure to connect the cables to the correct ports.
DO NOT obstruct the device ventilation slots, as insufficient airflow may harm your device.
DO NOT place items on the device.
DO NOT use the device for outdoor applications, and make sure all the connections are indoors. There may be a remote risk
of electric shock from lightning.
Be careful when unplugging the power, because the transformer may be very hot.
Keep the device and all its parts and accessories out of children’s reach.
Clean the device using a soft and dry cloth rather than liquid or atomizers. Power off the equipment before cleansing it.
This product is recyclable. Dispose of it properly.

NVF-400L/R 4 Band VDSL CO/CPE Bridge with 4 Ports Switch USER’S MANUAL Ver. A.5
4
Table of Contents
Copyright.................................................................................................................................................................................. 1
Foreword: VDSL Point to Point Solution................................................................................................................................ 2
Safety Warnings....................................................................................................................................................................... 3
Table of Contents..................................................................................................................................................................... 4
1.1 Check List...................................................................................................................................................................................................... 5
Chapter 2. Installing the Bridge .............................................................................................................................................. 6
2.1 Hardware Installation..................................................................................................................................................................................... 6
2.2 Pre-installation Requirements........................................................................................................................................................................ 6
2.3 General Rules................................................................................................................................................................................................. 7
2.4 Connecting the Bridge ................................................................................................................................................................................... 7
2.5 Connecting the RJ-11 / RJ-45 Ports............................................................................................................................................................... 8
Chapter 3. Hardware Description............................................................................................................................................ 10
3.1 Front Panel................................................................................................................................................................................................... 10
3.2 Front Indicators.............................................................................................................................................................................................11
3.3 Rear Panel.................................................................................................................................................................................................... 12
Chapter 4. Firmware Description............................................................................................................................................ 13
Appendix A: Cable Requirements........................................................................................................................................... 14
Appendix B: Product Specification ........................................................................................................................................ 17
Appendix C: 4 Band VDSL Electrical Characteristics........................................................................................................... 20
Appendix D: Troubleshooting................................................................................................................................................. 21
Appendix E: Compliance and Safety Information................................................................................................................. 26
Warranty.................................................................................................................................................................................... 29
Chinese SJ/T 11364-2006......................................................................................................................................................... 30

NVF-400L/R 4 Band VDSL CO/CPE Bridge with 4 Ports Switch USER’S MANUAL Ver. A.5
5
Chapter 1.
Unpacking Information
1.1 Check List
Carefully unpack the package and check its contents to compare to the checklist.
Package Contents
•1 x VDSL 4-Band Bridge (NVF-400L or NVF-400R)
•2 x Rubber foot
•1 x CD User’s Manual
•1 xAC To DC 12V PowerAdapter
•1 x RJ-45 cable
•1 x RJ-11 cable
Note1:
Please inform your dealer immediately for any missing or damaged parts.
If possible, retain the carton including the original packing materials.
Use them to repack the unit in case there is a need to return for repair.
Note2:
1. Do not use sub-standard power supply. Before connecting the power supply to the device, be sure to check
compliance with specifications. The NVF-400L/R of the power supply use DC 12V/1A.
2. Power supply included in package is commercial-grade. Do not use in harsh environments.

NVF-400L/R 4 Band VDSL CO/CPE Bridge with 4 Ports Switch USER’S MANUAL Ver. A.5
6
Chapter 2. Installing the Bridge
2.1 Hardware Installation
This chapter describes how to install the bridge and establishes network connections. You may install the bridge on
any level surface (e.g. a table or shelf). However, please take note of the following minimum site requirements before
you begin. 2 rubber feet at the bottom are pre-installed to avoid scratches.
2.2 Pre-installation Requirements
Before you start the actual hardware installation, make sure you can provide the right operating environment including
power requirements, sufficient physical space and proximity to other network devices that are to be connected.
Verify the following installation requirements:
•Power requirements: DC 12V/1A or above.
•The bridge should be located in a cool dry place with at least 10cm/4in of space at the front and back for
ventilation.
•Place the bridge away from direct sunlight, heat sources, or areas with a high amount of
electromagnetic interference.
•Check if network cables and connectors needed for installation are available.
•Do Not install phone lines strapped together with AC power lines, or telephone office line with voice signal.
•Avoid installing this device with radio amplifying station nearby or transformer station nearby.
•Please note NVF-400 internal splitter, can pass through voice spectrum is 0KHz ~ 630KHz.

NVF-400L/R 4 Band VDSL CO/CPE Bridge with 4 Ports Switch USER’S MANUAL Ver. A.5
7
2.3 General Rules
Before making any connections to the bridge, note the following rules:
•Ethernet Port (RJ-45)
All network connections to the bridge Ethernet port must be made using Category 5 UTP for 100Mbps,
Category 3, 4 UTP for 10Mbps.
No more than 100 meters of cabling may be use between the MUX or HUB and an end node.
•VDSL Port (RJ-11)
All Home network connections to the RJ-11Port made using 24~26 Gauge with twisted pair phone wiring.
•We do not recommend using 28 Gauge or above phone line.
2.4 Connecting the Bridge
The bridge has four Ethernet port which support connection to Ethernet operation. The devices attached to these ports
must support auto-negotiation or 10Base-T or 100Base-TX unless they will always operate at half duplex. Use any of
the Ethernet ports to connect to devices such as NIC, Switch, bridge or router.
Note:
1.The RJ11 Line port is used to connect to the wall RJ-11 modular socket (outlet) that is connected to VDSL 4-Band
CPE bridge side (Point to point solution).
2.The RJ11 Phone port of the bridge can be connected to a telephone for making calls.
3.The console port is not available for use. It is use for engineering debug only.

NVF-400L/R 4 Band VDSL CO/CPE Bridge with 4 Ports Switch USER’S MANUAL Ver. A.5
8
2.5 Connecting the RJ-11 / RJ-45 Ports
1. The bridge’s RJ-11 ports supports maximum distance up to 1.9km at 5M/5M or maximum speed at 25M/25M
symmetrical with distances up to 800m data service across existing phone wiring without interfering with standard
voice transmissions, it is easy to use and does not require the installation of any additional wiring. Every RJ-11
modular phone jack in the home can become a port on the LAN. Networking devices can be installed on a single
telephone wire that can span within 1.9km or 800m (depending on speed) between the two farthest points. (Figure
2.1)
Figure 2.1 NVF-400L/R application

NVF-400L/R 4 Band VDSL CO/CPE Bridge with 4 Ports Switch USER’S MANUAL Ver. A.5
9
2. NVF-400L/R bridge has embedded splitter between every VDSL side (Line) and POTS (Phone) side. It permits you
to deliver broadband service on the same lines as Plain Old Telephone Service (POTS), PBX, ISDN traffic and
VDSL Signal.
3. The RJ-11 port support maximum distance 1.9km at 5M/5M or max speed 25M/25M symmetrical and distances up
to 800m data service. When inserting a RJ-11 plug, be sure to tab on the plug clicks into position to ensure that it is
properly seated.
4. Do not plug a RJ-11 phone jack connector into the Ethernet port (RJ-45 port). This may damage the bridge. Instead,
use only twisted-pair cables with RJ-45 connectors that conform to Ethernet standard.
Notes:
1. Be sure each twisted-pair cable (RJ-45) does not exceed 100 meters (333 feet).
2. RJ-11 port use 24 ~ 26 gauge phone wiring, we do not recommend 28 gauge or above.
3. We advise using Category 3, 4, 5 cables for Cable Bridge or Router connections to avoid any confusion or
inconvenience in the future when you upgrade attached to high bandwidth devices.
4. Be sure phone cable has been installed before NVF-400L/R powered on.

NVF-400L/R 4 Band VDSL CO/CPE Bridge with 4 Ports Switch USER’S MANUAL Ver. A.5
10
Chapter 3. Hardware Description
This section describes the important parts of the bridge. It features the front indicators and rear connectors.
NVF-400 Outward
3.1 Front Panel
The following figure shows the front panel. (Figure 3.1)
Figure 3.1 Front Panel of NVF-400L / NVF-400R
Tip:
At a quick glance of the front panel, it is easy to determine if the CO or CPE bridge has power, if it has
signal from its Ethernet RJ-45 port and if there is phone line signal on RJ-11 port.

NVF-400L/R 4 Band VDSL CO/CPE Bridge with 4 Ports Switch USER’S MANUAL Ver. A.5
11
3.2 Front Indicators
The Bridge has EIGHT LED indicators. The following Table shows the description. (Table 3-1)
Table 3-1 LED Indicators Description and Operation
LEDs Color Status Descriptions
On The device is receiving the power and functioning properly.
PWR
(Power LED) Green Off The device is not ready or has malfunctioned.
On The device has a good Ethernet connection.
Blinking The device is sending or receiving data.
E1~E4
(Ethernet LED) Green
Off The LAN is not connected.
On VDSL is in good linkage at 5Mbps data rate.
5M
(VDSL LED) Green Off The VDSL connection is down.
On VDSL is in good linkage at 15Mbps data rate.
15M
(VDSL LED) Green Off The VDSL connection is down.
On VDSL is in good linkage at 25Mbps data rate.
25M
(VDSL LED) Green Off The VDSL connection is down.

NVF-400L/R 4 Band VDSL CO/CPE Bridge with 4 Ports Switch USER’S MANUAL Ver. A.5
12
3.3 Rear Panel
The following figure shows the rear connectors. (Figure 3.2)
Figure 3.2 Rear connectors
And the table shows the description. (Table 3-2)
Table 3-2 Description of the bridge rear connectors
Connectors Type Description
Ethernet 1~4 RJ-45 For Ethernet equipped device connection
Line RJ-11 For VDSL Bridge connection.
Phone RJ-11 For telephone or Fax, ISDN bridge connection.
Console RS-232C For In-band management.
Power 12Vdc adapter For power supply.
Note:
If it is needed to connect to the ISDN bridge, please refer to Appendix C for further details.

NVF-400L/R 4 Band VDSL CO/CPE Bridge with 4 Ports Switch USER’S MANUAL Ver. A.5
13
Chapter 4. Firmware Description
Auto speed function description:
NVF-400L/R is a 4 band VDSL solution which supports auto speed function and real plug & play. It can support
5M/15M/25M symmetrical data service but depends on installation environment and cable limit length. It can also do auto
speed function while phone cable be re-plug in between NVF-400L and NVF-400R, or both be re-power on. NVF-400L will
try to link at 25M/25M mode first, if the link fails, it will auto speed down to 15M/15M mode, and if the link fails again, it will
auto speed down to 5M/5M, then stay on this mode until re-plug in phone cable or re-power on them, to restart auto speed
function again, both link up need one to three minutes which depend on phone cable length by auto-speed function.
Speed mode limitation:
1. 5M/5M mode within 1.9km (6333 ft.)
2. 15M/15M mode within 1.3km (4333 ft.)
3. 25M/25M mode within 800m (2666 ft.)
Tip:
With the above phone cable limit based on without PBX noise.
Note1:
We recommend phone cable that must meet Cat. 3 standard or above and without clustering, otherwise the above
guarantee will be void.
Note2:
The performance data above is for reference only, the actual distance will vary on the quality of the copper wire and
environment factors. We recommend using 24~26 gauge and Cat. 3 standard or above phone wiring.

NVF-400L/R 4 Band VDSL CO/CPE Bridge with 4 Ports Switch USER’S MANUAL Ver. A.5
14
Appendix A: Cable Requirements
A.1 Ethernet Cable
A CAT 3, 4 or 5 UTP (unshielded twisted pair) cable is typically used to connect the Ethernet device to the modem.A
10Base-T cable often consists of four pairs of wires, two of which are used for transmission. The connector at the end of the
10Base-T cable is referred to as an RJ-45 connector and it consists of eight pins. The Ethernet standard uses pins 1, 2, 3
and 6 for data transmission purposes. (Table A-1)
Table A-1 RJ-45 Ethernet Connector Pin Assignments
MDI MDI-X
PIN #
Signal
Media Dependant
interface Signal
Media Dependant
interface-cross
1 TX+ Transmit Data + RX+ Receive Data +
2 TX- Transmit Data - RX- Receive Data -
3 RX+ Receive Data + TX+ Transmit Data +
4 -- Unused -- Unused
5 -- Unused -- Unused
6 RX- Receive Data - TX- Transmit Data -
7 -- Unused -- Unused
8 -- Unused -- Unused
Figure A-1 Standard RJ-45 repectacle/connector
Note:
Please make sure your connected cables are with same pin assignment as above table before deploying the cables into your
network.

NVF-400L/R 4 Band VDSL CO/CPE Bridge with 4 Ports Switch USER’S MANUAL Ver. A.5
15
Figure A-2 Pin Assignments and Wiring for an RJ-45 Straight-Through Cable
Figure A-3 Pin Assignments and Wiring for an RJ-45 Crossover Cable

NVF-400L/R 4 Band VDSL CO/CPE Bridge with 4 Ports Switch USER’S MANUAL Ver. A.5
16
A.2 Telephone wire
Standard telephone wire of any gauge or type-flat, twisted or quad is used to connect the Modem to the telephone network.A
telephone cable typically consists of three pairs of wires, one of which is used for transmission. The connector at the end of
the telephone cable is called an RJ-11 connector and it consists of six pins. POTS (plain old telephone services) use pins 3
and 4 for voice transmission.A telephone cable is shown below. (Figure A-4)
A
B
Figure A-4 Telephone cable
The A and B connectors on the rear of the Modem are RJ-11 connectors. These connectors are wired identically. The RJ-11
connectors have six positions, two of which are wired. The Modem uses the center two pins. The pin out assignment for
these connectors is presented below. (Table A-2)
Table A-2 RJ-11 Pin out Assignments
Pin# MNEMONIC FUNCTION
1 NC Unused
2 NC Unused
3 TIP POTS
4 RING POTS
5 NC Unused
6 NC Unused_

NVF-400L/R 4 Band VDSL CO/CPE Bridge with 4 Ports Switch USER’S MANUAL Ver. A.5
17
Appendix B: Product Specification
Key Features & Benefits
•Supports Universal Plug & Play(UPnP)
•Compliant with IEEE802.3 10BASE-T and IEEE802.3u 100BASE-TX standard
•Compliant with ETSI, ITU, ANSI standards
•Supports high bandwidth up to 25Mbps symmetrical
•Supports 1 * RJ-11 connector for Ethernet over VDSL
•Supports 1 * RJ-11 connector for telephone/PBX connection
•Supports 4 * RJ-45 port for 10/100Mbps Ethernet with Auto MDI/MDIX
•Supports Auto-speed and full duplex for VDSL port
•Supports long packet size up to 1536 bytes
•Supports POTS/ISDN voice pass
•Supports 4wires phone set pass through
•Voice and Data work on the same telephone line
•Spectral compatibility with xDSL, ISDN (2B1Q/4B3T)
•Supports flow control IEEE802.3x for Full Duplex & Back Pressure for Half Duplex
•Supports Surge protection
•Provides Power LED and LED indication Link/Active Status for Ethernet port and 5/15/25Mbps Link/Speed for
VDSL port
•EMI certified by CE and FCC

NVF-400L/R 4 Band VDSL CO/CPE Bridge with 4 Ports Switch USER’S MANUAL Ver. A.5
18
Product Specification
Standard: IEEE802.3 standard
IEEE802.3u standard
Compliant with ETSI, ITU,ANSI standards
Interface:
4 * RJ-45 10/100Mbps Ethernet port
1 * RJ-11 connector for EoVDSL
1 * RJ-11 connector for telephone connection
1 * RS-232C / 19200bps for Console port
Cable Connections: RJ-45 (Ethernet): Category 3, 4, 5 UTP/STP
RJ-11 (EoVDSL): Twisted-Pair phone wire
LED indication: Power
Link/Active Status for Ethernet port
5/15/25Mbps Link/Speed for VDSL port
VDSL Frequency Spectrum:
NVF-400L_Transmitter: 900kHz ~ 3.9MHz
Receiver: 4MHz ~ 7.9MHz
NVF-400R_Transmitter: 4MHz ~ 7.9MHz
Receiver: 900kHz ~ 3.9MHz
POTS/ISDN pass filter Spectrum:
0 ~ 630kHz
Power Consumption: NVF-400L (LT): 4.2W
NVF-400R (NT): 5.04W
Operating Temperature: 0°C ~ 50°C (32°F ~ 122°F)
Storage Temperature: -20°C ~ 70°C (-4°F ~ 158°F)
Humidity: 10 to 90% (non-condensing)

NVF-400L/R 4 Band VDSL CO/CPE Bridge with 4 Ports Switch USER’S MANUAL Ver. A.5
19
Dimensions: 184mm x 146mm x 40mm (7.2" x 5.74" x 1.57”)
Weight: 0.78kg & 1.02kg (for metal case)
External Power Adapter Input: AC 85~240 volts/50~60Hz
Output: DC 12V/1A
This manual suits for next models
1
Table of contents
Other netsys Network Hardware manuals