netsys NVF-200LS/R User manual

N
N
N
V
V
V
F
F
F
-
-
-
2
2
2
0
0
0
0
0
0
L
L
L
S
S
S
/
/
/
R
R
R
v
v
v
e
e
e
r
r
r
.
.
.
S
S
S
4
4
4
B
B
Ba
a
an
n
nd
d
d
V
V
VD
D
DS
S
SL
L
L
C
C
CO
O
O/
/
/C
C
CP
P
PE
E
E
B
B
Br
r
ri
i
id
d
dg
g
ge
e
e
w
w
wi
i
it
t
th
h
h
D
D
Di
i
ip
p
p
S
S
Sw
w
wi
i
it
t
tc
c
ch
h
h
U
U
US
S
SE
E
ER
R
R’
’
’S
S
S
M
M
MA
A
AN
N
NU
U
UA
A
AL
L
L

NVF-200LS/R ver.S 4 Band VDSL CO/CPE Bridge USER’S MANUAL Ver. B.4
1
Copyright
Copyright © 2011 by National Enhance Technology Corp. All rights reserved.
Trademarks
NETSYS is a trademark of National Enhance Technology Corp.
Other brand and product names are registered trademarks or trademarks of their respective holders.
Legal Disclaimer
The information given in this document shall in no event be regarded as a guarantee of conditions or characteristics. With respect
to any examples or hints given herein, any typical values stated herein and/or any information regarding the application of the
device, National Enhance Technology Corp. hereby disclaims any and all warranties and liabilities of any kind, including without
limitation warranties of non-infringement of intellectual property rights of any third party.
Statement of Conditions
In the interest of improving internal design, operational function, and/or reliability, NETSYS reserves the right to make changes to
the products described in this document without notice. NETSYS does not assume any liability that may occur due to the use or
application of the product(s) or circuit layout(s) described herein.
Maximum signal rate derived form IEEE Standard specifications.Actual data throughput will vary. Network conditions and
environmental factors, including volume of network traffic, building materials and construction, and network overhead lower actual
data throughput rate. Netsys does not warrant that the hardware will work properly in all environments and applications, and makes
no warranty and representation, either implied or expressed, with respect to the quality, performance, merchantability, or fitness
for a particular purpose. Make sure you follow in line with the environmental conditions to use this product.

NVF-200LS/R ver.S 4 Band VDSL CO/CPE Bridge USER’S MANUAL Ver. B.4
2
Foreword: VDSL Point to Point Solution
Attention:
Be sure to read this manual carefully before using this product. Especially Legal Disclaimer, Statement
of Conditions and Safty Warnings.
The NVF-200LS/R ver.S works as Ethernet to/from VDSL subscriber-site conversion bridge. The NVF-200LS/Rver.S uses
QAM-based 4-band VDSL technology which supports max distance 1.9km (6333 ft.) at 5M/5M or 1.3km (4333 ft.) at 15M/15M, or
800m (2666 ft.) at 25M/25M symmetrical data service. The NVF-200R ver.S also works with NVF-800S/NVF-2400S VDSL IP
DSLAM, together to form a cost-effective solution for services such as remote lecturing, telemedicine, video conferencing,
Video-on-Demand (VOD), IP-TV, Internet access, and various high-speed data applications.
The front-panel provides LED indicators of system and interface status. The built-in POTS/ISDN splitter allows a standard POTS
phone or ISDN device to be connected. Full or half-duplex mode of LAN operations is automatically sensed and configured. VDSL
link rates are configured by local bridge or IP DSLAM over auto speed or fix speed function.
Therefore, NVF-200LS/R ver.S supports plug & play operations on the subscriber-site and can do auto and manual selection of the
data speed. An ideal solution for delivering cost-effective, high-performance broadband/multimedia services to Multi-Dwelling Units
(MDU) and Multi-Tenant Units (MTU) such as hotels, campuses and hospitals environments.

NVF-200LS/R ver.S 4 Band VDSL CO/CPE Bridge USER’S MANUAL Ver. B.4
3
Caution:
The NVF-200 is for indoor applications only. This product does not have waterproof protection. We do not recommend for harsh
environments. If user insist to install it for industrial applications (-20°C ~ 70°C (-4°F ~ 158°F)), please do not use the included
commercial-grade power supply. Please use of industrial-grade power supply for industrial applications.

NVF-200LS/R ver.S 4 Band VDSL CO/CPE Bridge USER’S MANUAL Ver. B.4
4
Safety Warnings
For your safety, be sure to read and follow all warning notices and instructions before using the device.
DO NOT open the device or unit. Opening or removing covers can expose you to dangerous high voltage points or other
risks. ONLY qualified service personnel can service the device. Please contact your vendor for further information.
Use ONLY the dedicated power supply for your device. Connect the power cord or power adaptor to the right supply voltage
(110V AC used for North America and 230V AC used for Europe).
DO NOT use the device if the power supply is damaged as it might cause electrocution. If the power supply is damaged,
remove it from the power outlet. DO NOT attempt to repair the power supply. Contact your local vendor to order a new power
supply.
Place connecting cables carefully so that no one will step on them or stumble over them. DO NOT allow anything to rest on
the power cord and do NOT locate the product where anyone can work on the power cord.
DO NOT install nor use your device during a thunderstorm. There may be a remote risk of electric shock from lightning.
DO NOT expose your device to dampness, dust or corrosive liquids.
DO NOT use this product near water, for example, in a wet basement or near a swimming pool.
Connect ONLY suitable accessories to the device.
Make sure to connect the cables to the correct ports.
DO NOT obstruct the device ventilation slots, as insufficient airflow may harm your device.
DO NOT place items on the device.
DO NOT use the device for outdoor applications, and make sure all the connections are indoors. There may be a remote risk
of electric shock from lightning.
Be careful when unplugging the power, because the transformer may be very hot.
Keep the device and all its parts and accessories out of children’s reach.
Clean the device using a soft and dry cloth rather than liquid or atomizers. Power off the equipment before cleansing it.
This product is recyclable. Dispose of it properly.

NVF-200LS/R ver.S 4 Band VDSL CO/CPE Bridge USER’S MANUAL Ver. B.4
5
Table of Contents
COPYRIGHT ........................................................................................................................................................1
FOREWORD: VDSL POINT TO POINT SOLUTION.............................................................................................2
SAFETY WARNINGS...........................................................................................................................................4
CHAPTER 1. UNPACKING INFORMATION.........................................................................................................7
1.1 Check List ......................................................................................................................................................................................7
CHAPTER 2. INSTALLING THE BRIDGE.............................................................................................................8
2.1 Hardware Installation......................................................................................................................................................................8
2.2 Pre-installation Requirements ........................................................................................................................................................8
2.3 General Rules ................................................................................................................................................................................9
2.4 Connecting the Bridge....................................................................................................................................................................9
2.5 Connecting the RJ-11 / RJ-45 Ports.............................................................................................................................................10
CHAPTER 3. HARDWARE DESCRIPTION........................................................................................................12

NVF-200LS/R ver.S 4 Band VDSL CO/CPE Bridge USER’S MANUAL Ver. B.4
6
3.1 Front Panel...................................................................................................................................................................................12
3.2 Front Indicators ............................................................................................................................................................................13
3.3 Rear Panel...................................................................................................................................................................................14
3.4 Side Panel....................................................................................................................................................................................15
CHAPTER 4. FIRMWARE DESCRIPTION .........................................................................................................17
APPENDIX A: CABLE REQUIREMENTS ...........................................................................................................18
APPENDIX B: PRODUCT SPECIFICATION.......................................................................................................21
APPENDIX C: 4 BAND VDSL ELECTRICAL CHARACTERISTICS....................................................................23
APPENDIX D: TROUBLESHOOTING ................................................................................................................24
APPENDIX E: COMPLIANCE AND SAFETY INFORMATION ............................................................................29
WARRANTY.......................................................................................................................................................32
CHINESE SJ/T 11364-2006................................................................................................................................33

NVF-200LS/R ver.S 4 Band VDSL CO/CPE Bridge USER’S MANUAL Ver. B.4
7
CHAPTER 1.
UNPACKING INFORMATION
1.1 Check List
Carefully unpack the package and check its contents against the checklist.
Package Contents
•VDSL 4-Band Bridge (NVF-200LS for CO side / NVF-200R ver.S for CPE side)
•1 xAC to DC 5V or 12V Power Adapter
•4 x rubber foot
•1 x CD User’s Manual
•1 x RJ-45 cable
•1 x RJ-11 cable
Note1:
Please inform your dealer immediately for any missing or damaged parts.
If possible, retain the carton including the original packing materials.
Use them to repack the unit in case there is a need to return for repair.
Note2:
1. Do not use sub-standard power supply. Before connecting the power supply to the device, be sure to check
compliance with specifications. The NVF-200LS/R ver.S of the power supply use DC 5-12V/1A.
2. Power supply included in package is commercial-grade. Do not use in harsh environments.

NVF-200LS/R ver.S 4 Band VDSL CO/CPE Bridge USER’S MANUAL Ver. B.4
8
Chapter 2. Installing the Bridge
2.1 Hardware Installation
This chapter describes how to install the bridge and establishes network connections and may install the bridge on any
level surface (e.g. a table or shelf). However, please take note of the following minimum site requirements before one
begin. Stick the 4 rubber feet at the bottom to avoid scratches.
2.2 Pre-installation Requirements
Before you start the actual hardware installation, make sure you can provide the right operating environment, including
power requirements, sufficient physical space, and proximity to other network devices that are to be connected.
Verify the following installation requirements:
•Power requirements: DC 5-12V / 1A or above
•The bridge should be located in a cool dry place, with at least 10cm/4in of space at the front and back for
ventilation.
•Place the bridge away from direct sunlight, heat sources, or areas with a high amount of electromagnetic
interference.
•Check if the network cables and connectors needed for installation are available.
•Do Not install phone lines strapped together with AC power lines, or telephone office line with voice signal.
•Avoid installing this device with radio amplifying station nearby or transformer station nearby.
•Please note NVF-200 internal splitter, can pass through voice spectrum is 0KHz ~ 630KHz.

NVF-200LS/R ver.S 4 Band VDSL CO/CPE Bridge USER’S MANUAL Ver. B.4
9
2.3 General Rules
Before making any connections to the bridge, please note the following rules:
•Ethernet Port (RJ-45)
All network connections to the bridge Ethernet port must be made using Category 5 UTP for 100Mbps,
Category 3, 4 UTP for 10Mbps.
No more than 100 meters of cabling may be use between the MUX or HUB and an end node.
•VDSL Port (RJ-11)
All Home network connections to the RJ-11port must use 24~26 gauge with twisted pair phone wiring.
We do not recommend the use of the telephone line 24 gauge below or 26 gauge above.
2.4 Connecting the Bridge
The bridge has one Ethernet port which support connection to Ethernet operation. The devices attached to these ports
must support auto-negotiation or 10Base-T OR 100Base-TX unless they will always operate at half duplex. Use any of
the Ethernet ports to connect to devices such as NIC, Switch, bridge or router.
Note:
1.The RJ11 Line port is used to connect to the wall RJ-11 modular socket (outlet) that is connected to VDSL 4-Band
CPE bridge side (Point to point solution).
2.The RJ11 Phone port of the bridge can be connected to a telephone for making calls.

NVF-200LS/R ver.S 4 Band VDSL CO/CPE Bridge USER’S MANUAL Ver. B.4
10
2.5 Connecting the RJ-11 / RJ-45 Ports
1. The bridge’s RJ-11 ports supports max distance 1.9km at 5M/5M or max rate 25M/25M symmetrical and distances
up to 800m data service across existing phone wiring, without interfering with standard voice transmissions,
easy-to-use which do not require installation of additional wiring. Every RJ-11 modular phone jack in the home can
become a port on the LAN. Networking devices can be installed on a single telephone wire that can span within
1.9km or 800m (depends on speed) between the two farthest points. (Figure 2.1)
Figure 2.1 VDSL Point-to-Point application

NVF-200LS/R ver.S 4 Band VDSL CO/CPE Bridge USER’S MANUAL Ver. B.4
11
2. NVF-200LS/R bridge has an embedded splitter between every VDSL side (Line) and POTS (Phone) side. It permits
one to deliver broadband service on the same lines as Plain Old Telephone Service (POTS), PBX, ISDN traffic and
VDSL Signal.
3. When inserting a RJ-11 plug, make sure the tab on the plug clicks into position to ensure that it is properly seated.
4. Do not plug a RJ-11 phone jack connector into the Ethernet port (RJ-45 port). This may damage the bridge. Instead,
use only twisted-pair cables with RJ-45 connectors that conform to Ethernet standard.
Notes:
1. Be sure each twisted-pair cable (RJ-45) does not exceed 100 meters (333 feet).
2. RJ-11 port use 24 ~ 26 gauge with twisted pair phone wiring.
3. We advise using Category 3 ~7 cables for Cable bridge or Router connections to avoid any confusion or
inconvenience in the future when you attached to high bandwidth devices.
4. Be sure phone cable has been installed before NVF-200LS and NVF-200R ver.S powered on.

NVF-200LS/R ver.S 4 Band VDSL CO/CPE Bridge USER’S MANUAL Ver. B.4
12
Chapter 3. Hardware Description
This section describes the important parts of the bridge. It features the front panel, side panel and rear connectors.
NVF-200LS/R ver.S Outward
3.1 Front Panel
The figure shows the front panel. (Figure 3.1)
Figure 3.1 Front Panel
Tip:
At a quick glance of the front panel, it is easy to determine if the CO or CPE bridge has power, if it has
signal from its Ethernet RJ-45 port and if there is phone line signal on RJ-11 port.

NVF-200LS/R ver.S 4 Band VDSL CO/CPE Bridge USER’S MANUAL Ver. B.4
13
3.2 Front Indicators
The bridge has Five LED indicators. The following Table shows the description. (Table 3-1)
Table 3-1 LED Indicators Description and Operation
LED Color Status Descriptions
On The device is receiving the power and functioning properly.
PWR
(Power LED) Green Off The device is not ready or has malfunctioned.
On The device has a good Ethernet connection.
Blinking The device is sending or receiving data.
E
(Ethernet LED) Green
Off The LAN is not connected.
On VDSL is in good linkage at 5Mbps data rate.
5
(VDSL LED) Green Off The VDSL connection is down.
On VDSL is in good linkage at 15Mbps data rate.
15
(VDSL LED) Green Off The VDSL connection is down.
On VDSL is in good linkage at 25Mbps data rate.
25
(VDSL LED) Green Off The VDSL connection is down.

NVF-200LS/R ver.S 4 Band VDSL CO/CPE Bridge USER’S MANUAL Ver. B.4
14
3.3 Rear Panel
The following figure shows the rear connectors. (Figure 3.2)
Figure 3.2 Rear connectors
And the table shows the description. (Table 3-2)
Table 3-2 Description of the bridge rear connectors
Connectors Type Description
Line RJ-11 For connecting to the VDSL bridge.
Phone RJ-11 For connecting to the telephone or Fax, ISDN bridge
Ethernet RJ-45 For connecting to a Ethernet equipped device
Note:
If it is needed to connect to the ISDN bridge, please refer to Appendix C for further details.

NVF-200LS/R ver.S 4 Band VDSL CO/CPE Bridge USER’S MANUAL Ver. B.4
15
3.4 Side Panel
The following figure shows the DIP switch connection. (Figure 3.3)
Figure 3.3 Side panel
At quick glance, it is easy to see that the DIP switch pin 1 is switch ON where it is in auto-speed and that is also the
default mode. (Figure 3.4)
Figure 3.4 DIP switch setting

NVF-200LS/R ver.S 4 Band VDSL CO/CPE Bridge USER’S MANUAL Ver. B.4
16
To set the data speed to 25Mbps simply switch ON the pin 2 while the other pins are switch OFF. To change it to
15Mbps, switch ON the pin 3 while the other pins are switch OFF, for 5Mbps switch on the pin 4 while other are switch OFF.
Remember that no two pins can be activated at the same time or it will result in error and for data speed of 5Mbps. Table
shows the summary of DIP switch configuration. (Table 3-3)
Table 3-3 DIP Switch Configuration
Speed mode Pin 1 Pin 2 Pin 3 Pin 4
Auto speed On Off Off Off
25Mbps Off On Off Off
15Mbps Off Off On Off
5Mbps Off Off Off On

NVF-200LS/R ver.S 4 Band VDSL CO/CPE Bridge USER’S MANUAL Ver. B.4
17
Chapter 4. Firmware Description
Auto and manual data speed selector description:
NVF-200LS/R is a 4band VDSL solution which supports real plug & play and can do auto and manual selection of the
data speed, the setting of the data speed depends on the phone cable length limit, they can support 5M/15M/25M
symmetrical data service but depends on installation environment. If NVF-200LS try to link at 25Mbps data speed but
fails to do so then NVF-200LS data speed must be lower due to the limitation of the phone cable length. If the cable
length is unsure, then auto selection of the data speed at the default setting is recommended. Power must be unplug
before changing of data speed then powered on and wait for VDSL to link again at the correct data speed function.
Speed mode limitation:
1. 5M/5M mode within 1.9km (6333 ft.)
2. 15M/15M mode within 1.3km (4333 ft.)
3. 25M/25M mode within 800m (2666 ft.)
Tip:
With the above phone cable limit based on without PBX noise.
Note1:
We recommend phone cable that must meet Cat. 3 standard or above and without clustering, otherwise the above
guarantee will be void.
Note2:
The performance data above is for reference only, the actual distance will vary on the quality of the copper wire and
environment factors. We recommend using 24~26 gauge and Cat. 3 standard or above phone wiring.

NVF-200LS/R ver.S 4 Band VDSL CO/CPE Bridge USER’S MANUAL Ver. B.4
18
Appendix A: Cable Requirements
A.1 Ethernet Cable
A CAT 3, 4 or 5 UTP (unshielded twisted pair) cable is typically used to connect the Ethernet device to the modem. A
10Base-T cable often consists of four pairs of wires, two of which are used for transmission. The connector at the end of the
10Base-T cable is referred to as an RJ-45 connector and it consists of eight pins. The Ethernet standard uses pins 1, 2, 3
and 6 for data transmission purposes. (Table A-1)
Table A-1 RJ-45 Ethernet Connector Pin Assignments
MDI MDI-X
PIN #
Signal
Media Dependant
interface Signal
Media Dependant
interface-cross
1 TX+ Transmit Data + RX+ Receive Data +
2 TX- Transmit Data - RX- Receive Data -
3 RX+ Receive Data + TX+ Transmit Data +
4 -- Unused -- Unused
5 -- Unused -- Unused
6 RX- Receive Data - TX- Transmit Data -
7 -- Unused -- Unused
8 -- Unused -- Unused
Figure A-1 Standard RJ-45 repectacle/connector
Note:
Please make sure your connected cables are with same pin assignment as above table before deploying the cables into your
network.

NVF-200LS/R ver.S 4 Band VDSL CO/CPE Bridge USER’S MANUAL Ver. B.4
19
Figure A-2 Pin Assignments and Wiring for an RJ-45 Straight-Through Cable
Figure A-3 Pin Assignments and Wiring for an RJ-45 Crossover Cable
Table of contents
Other netsys Network Hardware manuals
Popular Network Hardware manuals by other brands

Inscape Data
Inscape Data AirGoggle NVS 440R user manual

HIK VISION
HIK VISION DS-7732NI-I4/16P quick start guide

Multitech
Multitech MultiDSU56K owner's manual

Black Box
Black Box SW543A Specifications

Tripp Lite
Tripp Lite BP240V150 specification

HIK VISION
HIK VISION DeepinMind iDS-6700NXI-I/8F(B) Series user manual