Newstripe Aerovent Standard User manual

AeroVent® Standard Manual / 4840.0123
AeroVent®Standard
Product Manual

AeroVent®Standard
ALWAYS wear appropriate personal protective equipment when operating the unit!
AeroVent® Standard Manual / 4840.0123
TABLE OF CONTENTS
Precautionary Warning .............Page 1
Assembly...................................Page 2
Operation...................................Page 3
Maintenance..............................Page 4
Parts List....................................Page 4
Cobalt Point Replacement.........Page 5
Safe2VentReplacement..........Page 5
Warranty....................................Page 6
Thank you and congratulations on
your purchase of the AeroVent®
Standard aerosol can disposal system.
The AeroVent® Standard has been
designed to puncture and drain
aerosol cans that have been used and
are mostly empty. It is not intended to
continuously process full cans.
Please read over the instructions and
make sure you understand operating
procedures before using the unit.

AeroVent®Standard
ALWAYS wear appropriate personal protective equipment when operating the unit!
AeroVent® Standard Manual / 4840.0123
Always consult your facility safety manager for particular safety protocols
prior to operating this equipment.
This unit is not intended for use with spray adhesives or expanding foam sealant products.
PRECAUTIONARY WARNING!
Please read and understand all operating instructions as detailed in
this manual. Failure to follow specified instructions may result in
equipment damage or serious injury to personnel, including death.
Always refer to the current Product SDS for specific chemical
handling and safety instructions prior to deflating aerosol cans.
Liquids collected into drums and accompanying vapors may be
highly flammable. Keep all waste collection containers away from
heat, spark and flame –No Smoking near the unit or waste
collection containers!
Avoid static discharge. Ensure that the unit grounding cable is
attached to a suitable grounding source such as metal water pipe or
grounding rod prior to operation.
Keep the collection container closed when not in use and kept in a
cool, well-ventilated area away from ignition sources.
Only operate unit out-of-doors or in a well ventilated area.
Wear appropriate personal protective equipment and eye
protection; avoid direct contact with aerosol can contents.
CAUTION: Use of filters not specifically designed for the
AeroVent®, aerosol can disposal systems may result in dangerous
back pressure inside the recovery drum, resulting in equipment
damage or serious injury to personnel, including death.
ALWAYS refer to the Product SDS to check compatibility when
multiple aerosols are co-mingled in the same collection drum.
Caustics, Pesticides, Insecticides and White Metals should never
be collected into a drum with other liquids and should be
segregated into properly labeled, designated containers. Contact
your waste handler or Facility Safety Manager for more
information.

AeroVent®Standard
ALWAYS wear appropriate personal protective equipment when operating the unit!
AeroVent® Standard Manual / 4840.0123
ASSEMBLY
1) Install the front support foot in the base of the unit.
2) Remove the 2” bung plug from an empty 30 or 55 gallon recovery drum.
Insert the threaded nipple of the AeroVent® Standard into the opening and
turn the unit until it is hand tight. The rear support foot should be located
just inside the rim (chime) of the drum.
3) Adjust the rear support foot clockwise until it is snug to the top of the
drum. Then, adjust the front support foot until it is tight to the chime.
4) Open the lid and let it rest against the back stop. Remove the two screws
from the lid handle. Position the lid handle on top of the lid and tighten the
two screws from the underside of the lid.
5) Place the operating handle/clamp assembly on the mounting plate so
that the holes are aligned. Insert one bolt (with washer) through each
hole. Install one lock nut onto each bolt, but do not fully tighten. (Pic 1)
6) Place one of the plunger blocks into the hole on the closed lid assembly.
Lower the operating handle so that it is centered side-to-side on the plunger
block. Tighten all nuts and bolts of the operating handle assembly to the
mounting plate at this time. (Pic 2)
7) Install the can stop in the slots at the front of the trough liner.
8) Remove the 3/4” bung plug from the top of the recovery drum and thread
the Safe2Filterfilter housing into the ¾” bung. Hand-tighten only! Note:
Remove the plastic packaging completely before installing the SafeFilter
Filter.
9) Install the ground cable with a rear cover bolt of the AeroVent (See
the photos in the maintenance section). Attach the clamp end of the
ground cable to a suitable ground source, such as a metal water pipe
or ground rod.
Box should include these parts:
AeroVent®with Ground Cable
Operating Handle
Safe2Filter
5/16-18 x 3/4” Bolt (4)
¼” Flat Washers (4)
5/16-18 Lock Nuts (4)
Plunger Set (2”, 2.5” & 3”)
Can Stop
Lid Handle
Owner’s Manual
Lid Handle
#5
Pic 1
Mounting
Plate
Pic 2
Front
Support
Foot
Chime
Operating Handle
Mounting Hardware
Plunger
Set #7
Can Stop
Operating
Handle #3
Front Support
Foot
Safe2Filter
#14

AeroVent®Standard
ALWAYS wear appropriate personal protective equipment when operating the unit!
AeroVent® Standard Manual / 4840.0123
OPERATION
1) Using the can guide on the side of the unit, select the matching plunger (2”, 2.5” or 3”)
2) Lift the operating handle to release the clamp, and then open the AeroVent® lid.
3) The can stop should be in the slots at the front of the trough liner.
4) Apply grease to the lid gasket prior to use, and as needed to ensure a proper seal, to keep the lid from sticking to
the gasket.
5) Insert 1 aerosol can with the bottom of the can pointing toward the clamp, and up against the can stop.
6) Close the lid. Operate the AeroVent® by pushing down on the operating handle. (The clamp will engage the lid
and push the lid down).
7) Push the operating handle down, until the clamp locks into place in the Puncture & Drain Position. The aerosol
can has now been punctured. Wait 15-30 seconds to allow the can to drain. You may now lift the handle to
release the clamp, and open the lid to remove the can.
Note: If aerosol cans are mostly full, leave the handle in the locked position for at least 60 seconds to allow the
can to drain completely.
WARNING: DO NOT USE WITH EXPANDING FOAM SPRAYS, INSECTICIDES OR STRONG ADHESIVES.
PRECAUTIONARY WARNING!
Do not use the AeroVent®for draining expanding foam
sealant aerosol products or spray adhesive products.
Always use the correct plunger block for the diameter of the
can that you are draining.
The clamp must remain locked until the can completely
drains.
To insure that the can is drained, wait 15-30 seconds before
un-locking the clamp and opening the lid.
If a can is full when punctured, wait at least 1 minute before
opening the unit. Full cans take longer to empty and may
discharge fumes or liquids if the unit is opened too soon.
We recommend changing the Safe2Filter™ every 60 days or
600 cans. If cans contain larger amounts of remaining liquids,
change the filter more often. Also, we do not recommend
allowing the drum to become more than 70% (2/3) full. An
air space is needed in the drum to allow for draining and
venting of fumes.

AeroVent®Standard
ALWAYS wear appropriate personal protective equipment when operating the unit!
AeroVent® Standard Manual / 4840.0123
MAINTENANCE
ITEM
CHECK
*REPLACE
Lid Gasket 10004249
Before each use
Lubricate the surface regularly with
grease to keep the lid from sticking.
Safe2Filter 10004898 (2 pack)
Monthly
Change every 60 days or 600 cans, or
more often for full cans.
Cobalt Points 10003377
Inspect before each use
As Necessary.
Bellow 10003791
Inspect every 180 days
As Necessary.
Operating Clamp 10004208
Inspect before each use
Lubricate regularly with light oil.
(3-in-1, WD-40 etc.)
PARTS LIST
Item Part
Number Description Number Item Part
Number Description Number
1 Main Base Plate 10004285
2 Support Foot (2 required) 10004262
3 Operating Handle/Clamp 10004208
4 Swivel Foot 10004294
5 Lid Handle 10004195
6 Lid Grommet for Plunger 10002410
7 Plunger Set (2”, 2.5” & 3”) 10004248
8 Trough Liner w/ Can Stop 10003970
9 Trough Liner Grommet 10001874
10 Lid Gasket 10004249
11 Trough Bellow 10003791
12 Trough Spring 10004257
13 Cobalt Point 10003377
14 Safe2Filter Filter Assembly 10004841
15 Safe2Filter Replacement
Element 2 pack 10004898
16 Ground Cable Assembly 10003914
17 Left Shroud 10004286
18 Right Shroud 10004287
19 Bellows Clamp (2 required) 10003794
20 10-32 x 3/8” Retaining Screw 10001712
Lid Gasket
#10
Trough Liner with
Can Stop #8
Swivel Foot
#4
Operating
Handle #3
Safe2Filter
Filter #14
Support Foot
#2
Left Shroud
#17
Trough Liner
Grommet #9
Right Shroud
#18
Ground
Cable #16

AeroVent®Standard
ALWAYS wear appropriate personal protective equipment when operating the unit!
AeroVent® Standard Manual / 4840.0123
COBALT POINT REPLACEMENT
HELPFUL HINT: Leave the unit mounted on the drum to replace cobalt points.
1. Open the lid and then remove the left and right shrouds.
2. Loosen the bottom clamp on the bellows. Note: There is no need
to loosen the top bellows clamp, unless the bellows are damaged
and need replaced.
3. Remove the trough liner can stop. Note: The bellows may have to
be gently pried off of lower neck to rotate the assembly upward.
Rotate the trough assembly upward and allow it to rest against the
lid.
4. Remove the retaining screw with a 5/32” hex key and replace the
point. Apply blue (removable) 242 Loctite® to the retaining screw,
re-install it, and then tighten it against the new point.
5. Re-assemble the unit in reverse order.
SAFE2FILTER REPLACEMENT
1) Remove the filter lid from the element by grabbing the edge and pulling upwards (you can pull on the check
valve to expose the edge.)
2) Lift off the filter element from the base.
3) Install the new element onto the filter base.
4) Replace the filter lid by pressing it into the top of the element.
5) Dispose of the used filter element appropriately. DO NOT THROW AWAY THE LID AND BASE.
Keep the Lid
Keep the Base
Change the
Filter Element

AeroVent®Standard
ALWAYS wear appropriate personal protective equipment when operating the unit!
AeroVent® Standard Manual / 4840.0123
THE NEWSTRIPE WARRANTY –18 MONTH
NEWSTRIPE, INC., WARRANTS TO THE ORIGINAL PURCHASER, FOR 18 (EIGHTEEN) MONTHS AFTER
DATE OF PURCHASE, THAT THE EQUIPMENT* HEREBY SOLD SHALL BE FREE OF DEFECTS IN
MATERIALS AND WORKMANSHIP. THIS WARRANTY DOES NOT EXTEND TO ANY DAMAGE OR
MALFUNCTION RESULTING FROM MISUSE, NEGLECT, ACCIDENT, IMPROPER OPERATION, OR NORMAL
WEAR AND TEAR.
Damage incurred in shipment from Newstripe, Inc. to the customer is the total responsibility of the carrier. The
CUSTOMER MUST NOTE DAMAGES on the Bill of Lading of Trucking Company or Railroad; and Newstripe, Inc.
will furnish to the customer the cost or parts and labor. The customer can then bill the common carrier for the damages by
placing his signature on the documents.
The Newstripe, Inc. obligation under this warranty and any implied warranties is limited to replacement or repair of
defective parts of its manufacture without charge for 18 (Eighteen) months from date of purchase. For service under this
warranty, buyer shall ship the defective part or parts of the equipment, transportation prepaid, to Newstripe, Inc. together
with a written description of any claimed defect and proof of purchase date of the materials being returned. Prior to
retuning any part or machine, the CUSTOMER must obtain a Return Materials Authorization number. Call 1-
800-624-6706. To review the complete guidelines for warranty and returns, please visit
www.newstripe.com/guidlinesforwarrantyandreturn.
*Gasoline engines, compressors, pumps (including airless) and Transaxles are furnished with their respective
manufacturer's warranties only. Such components are not covered by any warranty of Newstripe, Inc. Where
Newstripe elects to extend manufacturers’ warranties, the warranty shall be pro-rated as to cover 100% of the cost
to replace or repair materials and parts for the first 12 months of ownership and 60% for the remaining 6 month
period.
The responsibilities described above are the only responsibilities of Newstripe, Inc. under this written warranty or any
implied warranty, and may be exercised only within 18 (Eighteen) months from the date of purchase. In no event shall
Newstripe, Inc. be liable for incidental or consequential damages and no person had any authority to bind it to any
representation or warranty, not be responsible for work done, materials furnished or repairs made by others without its'
specific written authorization.
THIS WARRANTY SHALL BE IN LIEU OF ANY AND ALL OTHER WARRANTIES, EXPRESSED OR IMPLIED,
INCLUDING ANY WARRANTIES OF MERCHANTABILITY OR FITNESS FOR A PARTICULAR PURPOSE, AND
THERE IS NO OTHER REPRESENTATION OR WARRANTY OF ANY KIND WITH RESPECT TO THE GOODS
SOLD HEREBY EXCEPT AS SET FORTH HEREIN. IT IS EXPRESSLY AGREED THAT THIS WARRANTY
SHALL BE LIMITED TO THE ADJUSTMENT, REPAIR OR REPLACEMENT OF PARTS AND THE LABOR AND
SERVICES REQUIRED THEREBY. IN NO EVENT, INCLUDING ANY CLAIM FOR NEGLIGENCE, SHALL
NEWSTRIPE, INC. BE LIABLE FOR INCIDENTAL OR CONSEQUENTIAL DAMAGES.
Sincerely,
Newstripe, Inc
Other manuals for Aerovent Standard
1
Table of contents