manuals.online logo
Brands
  1. Home
  2. •
  3. Brands
  4. •
  5. Nidec
  6. •
  7. Security Sensor
  8. •
  9. Nidec WL10 Series User manual

Nidec WL10 Series User manual

This manual suits for next models

2

Popular Security Sensor manuals by other brands

Honeywell Home PROSiXCOCN Installation and setup guide

Honeywell Home

Honeywell Home PROSiXCOCN Installation and setup guide

Duevi SIRPZ-RB-868 Operation

Duevi

Duevi SIRPZ-RB-868 Operation

RKI 65-2483RK Operator's manual

RKI

RKI 65-2483RK Operator's manual

Nortech PD160 Enhanced Series user manual

Nortech

Nortech PD160 Enhanced Series user manual

Omron K8AC-H2 manual

Omron

Omron K8AC-H2 manual

Agilent Technologies G8610 Series Quick reference card

Agilent Technologies

Agilent Technologies G8610 Series Quick reference card

Shinko SE2EA-1-0-0 instruction manual

Shinko

Shinko SE2EA-1-0-0 instruction manual

Det-Tronics X Series instructions

Det-Tronics

Det-Tronics X Series instructions

ACR Electronics COBHAM RCL-300A Product support manual

ACR Electronics

ACR Electronics COBHAM RCL-300A Product support manual

TOOLCRAFT 1712612 operating instructions

TOOLCRAFT

TOOLCRAFT 1712612 operating instructions

Elkron IM600 Installation, programming and functions manual

Elkron

Elkron IM600 Installation, programming and functions manual

Bosch WEU PDO 6 Original instructions

Bosch

Bosch WEU PDO 6 Original instructions

THORLABS PDA10JT user guide

THORLABS

THORLABS PDA10JT user guide

Waeco UV-DETECT operating manual

Waeco

Waeco UV-DETECT operating manual

Intermatic IOS-DSIMF manual

Intermatic

Intermatic IOS-DSIMF manual

Siemens AZL66 Series manual

Siemens

Siemens AZL66 Series manual

BTI Profiline Multi Finder operating instructions

BTI

BTI Profiline Multi Finder operating instructions

Challenger SL01 instruction manual

Challenger

Challenger SL01 instruction manual

manuals.online logo
manuals.online logoBrands
  • About & Mission
  • Contact us
  • Privacy Policy
  • Terms and Conditions

Copyright 2025 Manuals.Online. All Rights Reserved.

1
ImportantInformationandWarnings
HandlingPrecautions
ThankyouforpurchasingNIDECCOMPONENTS
CORPORATION.product.
Inordertousetheproductcorrectlyandmost
appropriately,pleasecompletelyreadthismanualbefore
useandkeepitforfuturereference.
LiquidLeakSensor
INSTRUCTIONMANUALVer.4.0
WL10series
Nishi-ShinjukuPrimeSquarebldg.,7-5-25
Nishi-Shinjuku,Shinjuku-ku,Tokyo160-0023,Japan
Phone:+81-3-3364-7055 Fax:+81-3-3364-7098
URL:https://www.nidec-components.com
Thiscautionmarkdescribeswhenthereisapossibilitythatusermaysufferfromdamageorphysicaldamage
mayoccuriftheproductisusedimproperly.
CEmarking
(CompliancewithEMCStandard)
Theseproducts(pressuresensors,pressureswitches,pressuregauges,pressureindicators,leakagesensors,etc.)aredesignedand
manufacturedasgeneralindustrialparts.Therefore,apersonwithsufficientknowledgeandexperienceshallconfirmtheconditions
andenvironmentsdescribedinthecatalog,specifications,andinstructionmanualofeachproduct,checkthesuitabilityofthe
productforthemachine,device,orsystemwhichyouuse,andensuresafetybeforeuse.
Theseproductsarenotintendedtobeusedforapplicationsparticularlyrequiringhighreliability(Theseinclude,butarenotlimited
to,nuclearpowercontrol,aerospaceandmilitarypurposes).
Thedetailsofwarrantyshallbeasperthedescriptionsinthisdocumentandweshallnotbeliableforanydamageonyouresulting
fromtheuseofanyequipmentordevice(includingcontrolsystems)whichisnotinaccordancewiththisdocument(hereinafter
referredtoas"useinviolation").Inthecasewhereyouresellourproducts,weshallnotbeliableforanydamageonathirdparty
resultingfromuseinviolationbythethirdparty,andevenifwemakepaymenttothethirdpartyinconnectionwithsuchusein
violationregardlessofthenamebywhichsuchpaymentmaybecalled,wemaydemandthewholeamountthereoffromyou. 
・Donotusethisproductunderenvironmentwithcorrosivegases.
・Highlyviscousliquidmaynotbestablydetected.
・Donotusethisproductforapplicationconstantlyimmersedintoliquid.
・Thedetectionofthesensormaybeunstablewhenthereisapresenceofairbubblesonthedetectionpartofthesensor.
・Errormayoccurifanyliquidisleftonthedetectionpartofthesensor,orifthedetectionpartisscratched.
・Dependingonthecolorofthemountingsurface,and/ortheconditionofthesurface,theoutputmaybecomeunstable.
・Whenthereisambientlighttothedetectionpartofthesensor,theoutputmaybecomeunstable.Pleasemakesurethereisnoambientlight
approachingtothedetectionpartofthesensor.
・Avoidfromplaceswithdust,dirt,andsteam.
・Pleaseturnoffthepowerwhencarryingoutthewiring.
・Donotusethisproductduringsysteminitialization.Itmayoutputexcessivesignal.
・ConnectFGterminalonthepowerlinetothegroundwhenusinganoutsideswitchingregulator.
・Donotwirethepowerlineparalleltoahighvoltageline.Itmaycausemalfunctionsfromnoise.
・PleaseusearegulatedDCpowersupply.Surgeabsorbingdevices(e.g.diodes,varistors,etc.)arenecessaryifinductiveloads,suchasrelaysor
solenoidsareconnectedtothepowerline.
・DonotstronglypullthecableorthePFAtubewhenwiring.Itmayresultindamageordecreaseinwaterproofstructure.
・DonotdamageorbendthePFAtube.Itmayresultindamageordecreaseinwaterproofstructure.
・Pleaseprovideenoughstraight-partatthecablenearthesensor.Bendingthecablenearthesensorwillleadtodamageordecreaseinwaterproof
structure.
・Pleasecheckifthefunctionofthesensorisnormalafterinstallment.
・Pleasechecktheoperationperiodicallytoavoidanytroublethatmayariseduringnormalusage.
・Afteruse,pleasewipethedetectionpartofthesensorandneighboringpartgentlywithsoftandcleancloth.
・TheprotectiveconstructionforthisleaksensorisIP67.(AccordingtoIECstandard)Pleaseconfirmbeforehandifthemediaisotherthenwater.
・Becarefulnottomiswire.Miswiringwillresultininternalcircuitdamage.Also,donotapplyvoltageorloadcurrentexceedingitsoutputcapacity.
…
2
ModelDesignation
Specifications
InternalElectricalSchematics
Cablelength
Medium
Operatingtemp.range
Operatinghumidity
Materialofthebody
Materialofthetube
Materialoftheinnercable
Supplyvoltage
Consumptioncurrent
Indication
Outputinterface
Switchingcapacity
Residualvoltage
Protectionofcircuit
Protectiongrade
Weight
    Water    
CorrosiveliquidcompatiblewithPFA
     -10to60℃(Nofreezing)
    35to85%RH(Nocondensation)
 PP(Polypropylene) PFA(bodyandcabletube)
     −     
PFA(Includesheatshrinkabletube)
         PVC
  12to24VDC±10%(Recommended12VDC)
         10mAmax.
Normal:SwitchoutputisON/GreenLEDisON
Detectionoftheleakage:SwitchoutputisOFF/
       RedLEDisON
   N*−*:NPNopencollectoroutput
   P*−*:PNPopencollectoroutput
N*−*:Sinkcurrent:50mAmax.Voltageendurance:30VDC
P*−*:Sourcecurrent:50mAmax.Voltageendurance:24VDC
  N*−*:1.0Vmax.,P*−*:2.0Vmax.
      Overcurrentprotection
     Reversepolarityprotection
   IP67(InaccordancewithIECIP-67)
*P−2:Approx.30g(2mcable)/*P−4Approx.50g(4mcable)
*F−2:Approx.45g(2mcable)/*F−4Approx.80g(4mcable)
Material
Switchoutputinterface
N:NPNOpencollectoroutput
P:PNPOpencollectoroutput
Type WL10−*P−* WL10−*F−*
P:PP(Polypropylene)
F:PFA
2:2m
4:4m
①WL10−N*−*Type
 (NPNopencollectoroutput)
②WL10−P*−*Type
 (PNPopencollectoroutput)
□ □ □
3
MountingMethod
1)Installationmethodofthemountingplate
Mountingplateistobesecuredby2piecesofM4screworM4studbolt.
Therecommendedtighteningtorqueisbelow0.5N・m.
2)Installationmethodofthesensor
Placethesensorhorizontallytothemountingplate.Fitinthesquareholeofthesensorwiththesalientofmountingplateandpressinthesensor
sothedetectionpartofthesensorcomesoutoftheMountingplate.
Ifthedetectionpartisnotsecuredproperly,thesensormaynotfunctionproperly.
3)Wiring
Makesurenottomiswirewhenwiring.Afterinstallation,makesureifthesensorisworkingproperly.
4)Methodfordismountingthesensor
Pinchthenotchonthemountingplateandpickupthesensor.
Makesurenottomiswirewhenwiring.Itmayresultininternalcircuitdamage.
Thedetectionpartisdisplacedfromground Thesensorfitonatilt
4
OutlineDimensions(Unit:mm)
WarrantyandDisclaimer
1)Thewarrantyperiodoftheseproductsisoneyearafterdeliverytoadesignatedplace.Thewarrantymentionedhereislimitedtothewarrantyofa
deliveredproductitself, anditdoesnot coverconsumablessuchas batteries.Eachproducthas itsownspecificationssuch asdurability(pressure
cycles).Therefore,checkwitheachserviceoffice.
2)Ifafailureordamageoftheproductoccursduringthewarrantyperiod,forwhichweareresponsible,wewillpromptlyreplaceorrepairtheproduct
freeofcharge. Thewarrantymentioned heremeansthe warrantyofthe productitselfanddoesnotcoverany damageinducedby afailureof the
product.
3)Thewarrantydoesnotcoverwhenanyofthefollowingitemsisapplicable:
・Thefailureiscausedbyconditions,environments,orhandlingnotdescribedinthecatalogueandagreedspecificationsandotherdocuments.
・Theproducthasbeenmodified,adjusted,orrepairedbyaperson/companyotherthanourcompanyafterdelivery.
・Thefailurecannotbeforeseenbythescientificandtechnologicalknowledgeatthetimeofdelivery.
・Thefailureiscausedbyforcemajeuresuchasdisasters.
◆WL10−*P−*Type
 (PP)
◆WL10−*F−*Type
 (PFA)
WL10−**−2
WL10−**−4
Type
2-φ4.5
PFAheatshrinkabletube
Detectionpart
Detectionpart
LED
3corecableφ2.9AWG28
PFAtubeφ4.4
φ25
26
18
7.6
16.5
2-φ4.5
9.9
5
8.1
10.6
26
18
φ25
3corecableφ2.9AWG28
LED
7.6
9.9
5
10.6
8.1
16.5