Throughout this manual, this mark:
indicates a required condition or procedure.
GRANITE COMPARATOR STAND
Precision Measuring Instrument Holder WGC-150・WGC-200
Model No.
User Manual
Thank you for purchasing the Niigata Seiki Granite Comparator Stand. This stand holds measuring tools with ȭ8
mm stem, including dial gauge and electronic micrometer, for measuring dimensions such as outside diameter,
thickness, and step heights.
●For safe and proper use of this product, please read this instruction manual
before use and follow the procedures described. Please keep manual where
it is accessible to user for future reference.
●Keep this manual with the instrument if transferred or leased to a third party.
●For inquiries about this product, please contact dealer or place of purchase.
SAFETY NOTICE
Moves vertically with attached
measuring instrument.
Fixes bracket to main post.
Vertical fine adjustment of instrument
clamp.
Measuring instrument mounts here.
Clamp secures measuring instrument.
Holds bracket for vertical positioning.
Work surface.
Platform will wear with continued
use, so please use block gauge to
check for wear before use.
①Bracket ・・・・・・・・・・・・②Bracket Clamp ・・・・・③Fine Adjustment ・・・ Knob
④Stem
・・・・・・・・・・・・・・ Mounting Hole
⑤Instrument ・・・・・・・・・ Mounting Clamp
⑥Main Post ・・・・・・・・・⑦
Measuring Platform
・・・■PART IDENTIFICATION ■
PACKAGE CONTENTS
■ASSEMBLY
SPECIFICATIONS ⑦Measuring
 Platform
①Bracket ②Bracket
 Clamp
⑥Main Post
Main Post Hole
M10 Bolt
Washer
Spring Washer
8mm Hex Wrench
①Bracket ⑦Measuring
 Platform
⑥Main Post
Washer
Spring Washer
M10 Bolt
※Model WGC-150 shown ※
Model WGC-150 shown
Please confirm the above items are included. If any items are
missing, please contact dealer or place of purchase.
●Material
 Measuring Platform…Granite
Main Post…Steel
 Bracket…Aluminum  135mm
250mm
Model
WGC-150
WGC-200
Base Flatness
2μm
ȭ8mm 3.0kg
6.9kg
Tighten
53
Insert
4
Mount
2
Insert
1※Requires 8mm Hex
Wrench (
Allen Wrench.)
※If Bracket clamp is
disassembled, first
assemble the clamp.
①Place the M10 bolt,
spring washer and
washer into the hole in
the Measuring Platform
as shown in the drawing.
②Mount the Main Post.
③Tighten the bolt to
secure the Main
Post to the
Measuring Platform
using the 8mm Hex
Wrench.
④Slide the Bracket
Clamp onto the Main
Post.
⑤Tighten the Bracket
Clamp to secure in
position.
Vertical
Stroke Length  ≧1mm
Fine Adjust Vertical
Stroke Length
Tighten
Stem
Mounting Hole Weight
(approx.)②
Bracket Clamp
SAFETY PRECAUTIONS Please Observe
Always follow these marked operating procedures in order to prevent harm to yourself or others, and to prevent
damage to property.
Improper use may result in personal injury or damage to property.
Read the instruction manual and follow the instructions.
・Use of product other than as described in the manual
may cause accident.
Use only for measuring.
・
Use for any purpose other than measuring may damage or
wear the instrument. Improper use may also cause accident.
Use in an environment which meets the following
conditions:
●Dry location protected from rain, water, and oils.
●Location not subject to wide temperature changes.
●Location free from cutting chips and dust.
●
Horizontal surface which is stable and free from vibration.
●Location protected from use by children and unauthorized
people.
・
Use in location contrary to the above may cause poor
accuracy, damage to the product, or may result in accident
or injury.
CAUTION
Handle With Care.
・
Do not drop or subject to shock -- instrument accuracy
may be affected.
・Do not allow water or oil to sit on measurement base,
use a soft cloth to clean.
Protect measuring platform from scratches.
・To prevent damage, use care when placing workpieces
onto platform surface, and avoid sharp edges.
When mounting measurement instrument to
bracket clamp, make sure clamp is tightened
firmly.
・If clamp is loose, measurement instrument may fall
and cause damage or affect instrument accuracy.
HOW TO USE
Measuring platform will wear with continued use.
Please check for wear before each use.
①Install an accurate measuring instrument.
②
Measure block gauge placed at several points on measuring
surface and make sure the reading is consistent.
If the reading varies significantly, please discontinue use as
the wear on the measuring surface is to large.
Wipe measuring platform with a clean, dry cloth or with cloth
moistened with alcohol to remove any contamination.
Do not use a stiff brush or abrasive pad as it will damage the surface and
cause poor accuracy.
Wipe any contamination from the main post and bracket
using a clean, dry cloth.
Store in area free from dust and with low humidity.
Cleaning and Storage After Use
CHECKING THE PLATFORM FOR WEAR
3
Loosen
1
Insert
2⑤Instrument
 Mounting Clamp
④Stem
 Mounting Hole
Measuring Instrument
Stem
③Fine Adjustmemt Knob
①Bracket
①
Insure that the measuring surface is free of dirt and is secure
and not loose.
Wipe measuring surface with soft cloth moistened with alcohol to
remove contamination. Insure that it is tight and is not scratched. Do
not use with damaged or loose platform as it will affect accuracy.
②Check that bracket moves smoothly.
Loosen the bracket clamp and check that it moves smoothly on
the main post. Otherwise, clean post and remove any
contamination or corrosion.
③Attach the measurement instrument to the bracket.
Firmly tighten the bracket clamp.
Loosen the instrument mounting clamp and insert the measuring
instrument stem into the mounting hole. Fix the instrument by
tightening the instrument mounting clamp.
Tighten ④Taking Measurements.
1.
Make sure that there is no dirt or dust on the measuring
platform, measuring instrument, or workpiece.
2.
While supporting the bracket by hand, loosen the bracket
clamp and adjust to roughly the desired height before
re-tightening the bracket clamp.
3.
Use the fine adjustment knob to fine-tune the height.
Perform the desired measurements.
※
Before start of measurement, please check the measuring
surface for wear using the following procedure.
Wear and performance degradation will vary
greatly depending on frequency and type of use.
We recommend periodic inspection conforming
your in-house standards and requirements.
⑦Measuring
 Platform ⑥Main Post ①Bracket
②Bracket
 Clamp
④
Stem
 
Mounting Hole
③
Fine Adjustment
 Knob
⑤Instrument
 
Mounting Clamp
Niigata Seiki Co., Ltd.
5-3-14, Tsukanome, Sanjo, Niigata, Japan, 955-0055
Tel. : +81-256-33-5522 Fax. : +81-256-33-5518
MAIL intl.sales@niigataseiki.co.jp
URL http://www.niigataseiki.co.jp
発売元
〒955-0055
新潟県三条市塚野目5丁目3番14号
(0256)33-5502(代)FAX(0256)33-5528
URL http://www.niigataseiki.co.jp
I400
-
K12106
この説明書は、必ずお守り頂きたい強制事項にマークを付けて表示しています。測定器を取り付け、上下に移動します。ブラケットを締め付けて、主柱に固定するクランプです。ステム取付穴に差し込んだ測定器の上下位置を微調整します。測定器のステムを差し込む取付用の穴です。
ステム取付穴に差し込んだ測定器のステムを、締め付けて固定するクランプです。
ブラケットを支える柱です。ワークを置く台です。使用を繰り返すうちに磨耗しますので、ご使用前に毎回、ブロックゲージを使用して磨耗確認を行ってください。①ブラケット…………②
ブラケットクランプ
… ③微動送り……………④ステム取付穴………⑤測定器クランプ……⑥主柱…………………⑦測定台………………石製コンパレータスタンド精密測定器保持具WGC
-
150・WGC
-
200品番取扱説明書この度は「石製コンパレータスタンド」をお買上げ頂きありがとうございます。この商品は、ダイヤルゲージ、電気マイクロメータなど㋡8ステムの測定器を保持し、ワークの外径・厚さ・段差などを測定する測定補助具です。●正しく安全にお使い頂くため、ご使用の前に本取扱説明書を必ず読み、記載の手順に従ってご使用ください。お読みになった後は、お使いになる方がいつでも見ることができる場所に、大切に保管してください。●第三者に譲渡・貸与される場合も、この説明書を必ず添付してください。●当商品に関するお問い合わせは、お買い求めの販売店もしくは当社にご連絡ください。安全上のお知らせ■各部の名称と機能■梱包内容の確認■組み立て方製品仕様⑦測定台⑥主柱⑦測定台①ブラケット②ブラケット クランプ①ブラケット②ブラケット クランプ②ブラケット クランプ⑥主柱主柱穴M10ボルトワッシャ
六角棒レンチ
8
mm
①ブラケット⑦測定台⑥主柱④ステム取付穴③微動送り⑤測定器クランプ※図はWGC
-
150を使用しています。※図はWGC
-
150を使用しています。上記の物が揃っているか確認し、部品が足りない場合は、お買い求めの販売店もしくは当社までご連絡ください。●材質測定台…花崗岩主 柱…ステンレスブラケット…アルミ安全上のご注意必ずお守りください。お使いになる人や他の人への危害、財産への損害を未然に防止するため、必ずお守り頂くことを下記のように説明しています。誤った使い方をした場合に『傷害を負う、または物的損害が発生するおそれがある内容』です。取扱説明書をよく読み、指示に従う。・取扱説明書に記載された内容以外での使用は、事故の原因となります。測定作業にのみ使用する。・指定用途以外へのご使用は、製品の破損や磨耗、予測できない事故の原因となります。下記の条件を満たす環境で使用する。●雨や水、油などがかからない、乾燥した場所●温度変化の少ない場所●切粉や粉塵が発生しない場所●振動やガタツキのない水平な場所●子どもや、使用者以外が近付かない場所・上記に反する場所での使用は、精度不良や製品の破損、事故やけがの原因となります。注意本器は大切に取り扱う。・落下などの衝撃を与えないでください。精度不良や製品の破損の原因となります。・測定台に水や油が付着した場合は長時間放置せず、柔らかい布などで拭き取ってください。測定台上面の傷に注意する。・傷防止のため、ワークは静かに測定台へ載せてください。また、鋭利なものは載せないでください。測定器を取り付けている時は、ブラケットクランプをしっかりと締めて固定する。・ブラケットクランプの締め付けがゆるいと、ブラケットごと測定器が落下し、測定器の故障・破損・精度不良の原因となります。使用方法①測定台に汚れ、傷、ガタツキなどが無いか確認する汚れは柔らかい乾いた布か、アルコールを少量含ませた布で拭き取ってください。ガタツキや、測定台上面に傷がある場合は精度が出ないため使用を中止してください。②ブラケットの動きがスムーズである事を確認するブラケットクランプをゆるめ、ブラケットを上下させます。動きがスムーズで無い場合は、主柱やブラケットの汚れ、錆などを取り除いてください。③測定器をブラケットに取り付けるブラケットクランプをしっかりと締めます。測定器クランプをゆるめて、ステム取付穴に測定器のステムを差し込み、測定器クランプを再度締めて固定してください。④測定する1.ワークや測定器の測定子にごみ・埃・汚れなどがないことを確認し、ワークを測定台の上に置きます。2.ブラケットを手で支えながら、ブラケットクランプをゆるめ、おおよその高さに合わせてブラケットクランプを締めます。3.微動送りねじで高さを微調整し、任意の位置に合わせたら測定を行ってください。測定台は使用を続けると磨耗します。毎回のご使用前に磨耗状況の確認を行ってください。①信頼できる測定器を取り付けます。②ブロックゲージを測定台の上に置いて数点測定し、お客様の測定に影響するような数値変化が無いか確認してください。数値変化がお客様の測定に影響する状態になったら、磨耗状況が大きいため使用を中止してください。※測定開始前に、下記手順に従って測定台の磨耗状況の確 認を行ってください。 135mm250mm品 番WGC
-
150WGC
-
200ベース平面度2μmステム取付穴㋡8mm質 量約3.0kg約6.9kg性能の劣化は、使用の頻度・環境によって大きく異なります。お客様の社内規格に準じた周期で、定期点検を行うことをおすすめ致します。測定台の汚れは柔らかい乾いた布か、アルコールを少量含ませた布で拭き取る。硬いブラシなどで汚れを落とすと測定台に傷がつき、精度不良の原因となるのでおやめください。主柱やブラケットの汚れを落としてから保管する。主柱やブラケットは柔らかい布などで汚れを拭き取り、湿度の少ない環境で保管してください。使用後のお手入れ・保管方法測定台の磨耗状況の確認締める5締める3締める3ゆるめる1差し込む4取り付け2差し込む1差し込む2⑤測定器クランプ④ステム取付穴測定器ステム③微動送り①ブラケット※組み立てには、六角棒レンチ8
mm
が必要です。※ブラケットクランプが外した状態で梱包されていた場合は、最初にブラケットクランプをブラケットに取り付けてください。①ワッシャ・スプリングワッシャ・
M10
ボルトを図の順番で測定台裏の主柱穴へ差し込みます。②
主柱を取り付けます。
③六角棒レンチ
8
mm
でボルトを締め、測定台に主柱を固定してください。④ブラケットを主柱へ差し込みます。⑤ブラケットクランプを締めて、ブラケットの位置を固定します。
ヘッド上下有効ストローク
1mm以上
微動送り上下ストローク
ワッシャ
スプリングワッシャ
M10ボルト
スプリングワッシャ

This manual suits for next models

1

Other Niigata seiki Rack & Stand manuals

Niigata seiki WSC-80 User manual

Niigata seiki

Niigata seiki WSC-80 User manual

Niigata seiki WGC-150 User manual

Niigata seiki

Niigata seiki WGC-150 User manual

Popular Rack & Stand manuals by other brands

ATCP SONELASTIC SX-PD Installation and operation manual

ATCP

ATCP SONELASTIC SX-PD Installation and operation manual

Vivo STAND-V102AM instruction manual

Vivo

Vivo STAND-V102AM instruction manual

SSS Siedle ZTVP 850-0 Product information

SSS Siedle

SSS Siedle ZTVP 850-0 Product information

Sanus BLT3 instruction manual

Sanus

Sanus BLT3 instruction manual

Mockett KP6/M2 quick start guide

Mockett

Mockett KP6/M2 quick start guide

Melchioni IRRADIO STV-IR-42100-FIX quick start guide

Melchioni

Melchioni IRRADIO STV-IR-42100-FIX quick start guide

HUANUO HNHM4 instruction manual

HUANUO

HUANUO HNHM4 instruction manual

Hydrofarm Active Aqua AASFT48 instructions

Hydrofarm

Hydrofarm Active Aqua AASFT48 instructions

CHIEF K1 installation instructions

CHIEF

CHIEF K1 installation instructions

bouncepad Wallmount Assembly instructions

bouncepad

bouncepad Wallmount Assembly instructions

BEHR KEEP COOL Curve 625 Fitting instructions

BEHR

BEHR KEEP COOL Curve 625 Fitting instructions

Ironwood GLACIER ATLAS LFAS 32 quick start guide

Ironwood

Ironwood GLACIER ATLAS LFAS 32 quick start guide

Britec DRYERSTRAP Assembling instructions

Britec

Britec DRYERSTRAP Assembling instructions

ricoo TS3111 installation manual

ricoo

ricoo TS3111 installation manual

Electronic Systems Support EFR63 Series Installation, operation and maintenance manual

Electronic Systems Support

Electronic Systems Support EFR63 Series Installation, operation and maintenance manual

peerless-AV SMARTMOUNT SF16D manual

peerless-AV

peerless-AV SMARTMOUNT SF16D manual

Abicor Binzel CAT2 operating instructions

Abicor Binzel

Abicor Binzel CAT2 operating instructions

Nibe GSU 30 Installer manual

Nibe

Nibe GSU 30 Installer manual

manuals.online logo
manuals.online logoBrands
  • About & Mission
  • Contact us
  • Privacy Policy
  • Terms and Conditions

Copyright 2025 Manuals.Online. All Rights Reserved.