Installation instruction
CTS 602 by Nilan
VP 18 EK
Version: 10.00, 13-04-2015
Software-version: 2.30

Table of contents
Table of contents ............................................................................................................................ 2
Figure table .................................................................................................................................... 2
Introduction..................................................................................................................................... 3
Power supply.................................................................................................................................. 4
Assembly of VP 18 EK.................................................................................................................... 5
Condensation drain / water seal ..................................................................................................... 7
HWS............................................................................................................................................... 8
Ducting ........................................................................................................................................... 9
Starting and set up of the CTS 602 control ................................................................................... 10
Starting ..................................................................................................................................... 10
Set up of the CTS 602 control................................................................................................... 10
Activating the service menu ...................................................................................................... 11
Central heating.......................................................................................................................... 12
Hotwater ................................................................................................................................... 13
Air quality.................................................................................................................................. 14
Air exchange............................................................................................................................. 15
Defrost...................................................................................................................................... 16
Temp. control............................................................................................................................ 17
Inlet control............................................................................................................................... 18
Room control ............................................................................................................................ 19
Restart...................................................................................................................................... 20
Preset....................................................................................................................................... 21
Manual...................................................................................................................................... 22
Modbus..................................................................................................................................... 23
Datalog ..................................................................................................................................... 24
Faultfinding................................................................................................................................... 25
Maintenance................................................................................................................................. 26
Energy saving............................................................................................................................... 29
Accessories/spare parts ............................................................................................................... 30
Figure table
Figure 1: CTS 602 control............................................................................................................... 4
Figure 2: Sketch of VP 18 EK ......................................................................................................... 6
Figure 5: Connection ...................................................................................................................... 8
Figure 6: Insulation of ducting......................................................................................................... 9
Figure 4: CTS 602 control............................................................................................................. 10
Figure 5: Headlines in the service menu........................................................................................11
Figure 7: The "Hotwater" menu..................................................................................................... 13
Figure 8: The "Air qulaity" menu ................................................................................................... 14
Figure 9: The "Air exchange" menu .............................................................................................. 15
Figure 10: The "Defrost" menu ..................................................................................................... 16
Figure 11: The "Temp. control" menu............................................................................................ 17
Figure 12: The "Inlet control" menu............................................................................................... 18
Figure 13: The "Room control" menu............................................................................................ 19
Figure 14: The "Restart" menu ..................................................................................................... 20
Figure 15: The "Preset" menu....................................................................................................... 21
Figure 16: The "Manual" menu ..................................................................................................... 22
Figure 17: The "Modbus" menu .................................................................................................... 23
Figure 18: The "Datalog" menu..................................................................................................... 24
Figure 19: Filtershift...................................................................................................................... 26

Ret til ændringer forbeholdes Side 3 af 30
Introduction
Please control that the following documents have been delivered together with the unit:
- Directions for assembly & use (this document)
- CTS 602 directions
- Electrical chart
Should you have any questions on how to operate the system, contact your nearest Nilan dealer,
who you can find at www.nilan.dk/dealers
VP 18 EK is a ventilation unit with heat recovery. The unit can yield up to 325m3/h at 100Pa exter-
nal back pressure. The energy in the exhaust air is being transferred to a 180L hot-water tank via a
heat pump. When the water is heated the remaining energy is being transferred to the supply air.
The unit is delivered with a G4 filter. In addition to this the unit can be equipped with different ac-
cessories e.g. hygrostat and filter box with pollen filter.
Operating the unit is done with the 600 control. The control has many functions such as menu
based attendance, week programme, time controlled filter guard and adjustment of the velocity of
the ventilator. (Directions for the CTS 602 control is described in another document delivered with
the unit.)
VP 18 EK is delivered in a white-lacquered aluminum-zinc cabinet, tested and ready for use. Instal-
lation and start-up must be carried out by an authorized electrician.

Ret til ændringer forbeholdes Side 4 af 30
Power supply
Power supply including safety switch must be installed by an authorized electrician.
The VP 18 EK -unit must be connected according to the attached electrical chart.
The unit is delivered with 1m test cable for the CTS 602 panel. The panel should be connected to
the CTS 602 control in the unit with cable type 2x2x0.25mm2twisted in pairs. (Maximum length
50m).
The CTS 602 panel must be placed dry and frost-proof. The panels’ integrated feeler prevents fur-
ther cooling of the building if the primary heat-supply stops by stopping the ventilation if the panel
feeler gets below a specific value. (Factory setting is 10°C; the value can be set from 1-20°C.)
The built-in sensor of the panel prevents further cooling of the building in case of outage of the
primary heating source. Should the panel sensor detect a temperature below the set value, the
ventilation system will stop. (Factory set position is 10 °C, can be set to anything between 1 and 20
°C)
Figure 1: CTS 602 control

Ret til ændringer forbeholdes Side 5 af 30
Assembly of VP 18 EK
When mounting the VP 18 EK -unit future service and maintenance should be consid-
ered. There is required a minimum of open space in front of the unit of 600mm measured
from the front of the unit.
In order to ease the mounting each of the connection pieces is labeled. Please notice the labels.
The connection between the unit and the ducting should be a flexible transition.
The unit should be leveled on a firm and vibration free bed. There should be at least 30mm to
building components and other inventory. The unit itself is quiet and almost vibration less; still any
potential vibration should be taken into account.
It is important to establish a condensation drain from the unit to the outlet. The unit has an inte-
grated water seal. The drain should be carried frost-proof and even downgrade to the outlet. The
overflow from the safety valve should also be carried to the nearest outlet.
If there is made a covering above the unit it should be easy to remove for maintenance purpose.
This manual suits for next models
1
Table of contents
Other nilan Air Conditioner manuals
Popular Air Conditioner manuals by other brands

Fujitsu
Fujitsu ASYG 09 LLCA installation manual

York
York HVHC 07-12DS Installation & owner's manual

Carrier
Carrier Fan Coil 42B Installation, operation and maintenance manual

intensity
intensity IDUFCI60KC-3 installation manual

Frigidaire
Frigidaire FAC064K7A2 Factory parts catalog

Sanyo
Sanyo KS2432 instruction manual

Mitsubishi Electric
Mitsubishi Electric PUHZ-RP50VHA4 Service manual

Panasonic
Panasonic CS-S18HKQ Service manual

Panasonic
Panasonic CS-E15NKE3 operating instructions

Gree
Gree GWH18TC-K3DNA1B/I Service manual

Friedrich
Friedrich ZoneAire Compact P08SA owner's manual

Daikin
Daikin R32 Split Series installation manual