C72 805/2008
127 / 137
GB
RUS
Before emptying the container it is a advisable to clean-
the filter (see “Shaking the main filter” sect.).
Normal version, not suitable for treating hazardousa)
dust
Release the container “I” (fig. 9), then remove and-
empty it.
Make sure that the seal is in perfect condition and cor--
rectly positioned.
Place the container back in position and use the lever-
to secure it again.
Plastic liner
A plastic liner (our code 40100) can be used to collect dust
(see fig. 9).
In this case, the machine must be equipped with optional
accessories (grill and depressor - fig. 9).
Versions for dusts that are hazardous for the health.b)
Classes M - H, suitable for vacuuming hazardous and/
or carcinogenic dust.
ATTENTION DANGER !
In compliance with current laws, these operations-
can only be carried out by trained and specialized
personnel who must wear adequate clothing.
Take care not to raise the dust during this operation.-
Wear a P3 protective mask.
A plastic liner can be used (our code 40100) or ABS-
safety container (our code 8 30202 - 8 31685) if dust
that is dangerous and/or hazardous for the health
must be removed.
The container and/or liner must only be disposed-
of by trained personnel and in compliance with the
current laws in force.
How to replace the safety container
Place the hose in a safe, dust-free place;-
Release the dusts container “I” (fig. 10);-
Close the safety container with the supplied cover and-
remove it from the dusts container “I” (fig. 10). Fit an
empty container in its place.
Start the motor again to prevent dust from being blown-
about.
Make sure that the seal is in perfect condition and cor--
rectly positioned.
Switch off the motor, fit an empty drum in place and-
fasten it in position.
Use as a wet cleaner
Make sure that the vacuum cleaner is equipped with a
float (liquid level sensor) and is suitable for use as a wet
cleaner.
Do not clean up flammable liquids.
If foam forms, stop work immediately and empty the con-
tainer.
The filter element will be wet after liquids have been cleaned
up.
Awet filter element can quickly become clogged if the vacuum
cleaner is then used to clean up dry substances.
For this reason, make sure that the filter element is dry or
replace it with another one before using the vacuum cleaner
to clean up dry materials.
At the end of a cleaning session-
Turn off the vacuum cleaner and remove the plug from1-
the socket.
Coil the connection flex (fig. 11).2-
Empty the container as described in the “Emptying3-
the container” section. Clean the vacuum cleaner as
described in the “Maintenance, cleaning and decon-
tamination” section.
Wash the container with clean water if aggressive sub-4-
stances have been cleaned up.
Store the vacuum in a dry place, out of the reach of5-
unauthorized people.
Shut the inlet with the appropriate plug “A” (fig. 11) when6-
the vacuum cleaner is transported or not being used
(particularly in the case of versions M - H).
Maintenance, cleaning and decontamina--
tion
ATTENTION DANGER !
Note: the precautions described below must be taken
during all the maintenance operations, including clea-
ning and replacing the main and Hepa filters.
To allow the user to carry out the maintenance opera-a)
tions, the vacuum must be disassembled, cleaned
and overhauled as far as is reasonably possible,
without causing hazards for the maintenance staff
or other people.
The suitable precautions include decontamination
before disassembling the vacuum, adequate filtered
ventilation for the air exhausted from the room in
which it is disassembled, cleaning of the maintenance
area and suitable personal protection.