Nobacco Stream User manual

STREAM Kit
USER MANUAL
www.nobacco.world

Thank you for selecng NOBACCO STREAM.
Please read the manual supplied and make sure that you have fully understood it before using the product.
For more informaon about the product or its use, please consult your local reseller or visit official product’s
webpage at www.nobacco.world .
Characteriscs:
NOBACCO STREAM uses INNOKIN’s ATHEON chipset with 75wa power and ClearWave noise cancelaon
technology. Choose your favorite coil head with STREAM TANK, or aach your preferred atomizer and enjoy an
astonishing vape experience.
Package contents*:
1 x NOBACCO STREAM with built in 2000mAh baery cell
1 x NOBACCO STREAM 2.0ml Glassomizer with 0.8 ohm coil head (organic coon)
1 x Extra coil head SS 0.5 ohm (organic coon)
1 x 510 Atomizer adaptor
1 x USB cable
1 x User manual
*The company reserves the right to change the contents and characteriscs of the package or/and the
product without any prior noce.
Preparaon, Open and Refill:
1. Press down the top cap of the tank to unscrew. Remove
the coil head and prime it with e-liquid.
2. Add e-liquid to the tank. Do not fill above MAX mark.
MAX capacity is 2ml
3. Securely reaach the top cap with the coil head to the
tank.
Aer the preparaon of the new coil head, leave the
atomizer for five (5) minutes prior to use to allow the coil
head to be fully saturated.
To refill the atomizer tank, you don’t need to remove the
coil head. Simply pour e-liquid.
CAUTION
Under no circumstances should the atomizer tank be empty of e-liquid, during usage. Malfuncon may occur
and you are running the risk of destroying the coil head. You are advised to refill when e-liquid level drops
below coil head’s feed holes.

TO MAINTAIN PEAK PERFORMANCE THE COIL HEAD NEEDS TO BE REPLACED PERIODICALLY.
Its life me depends on the usage and the e-liquid’s composion.
When a decrease in the amount of vapor and/or a tainted taste is noced, while using a recently charged
baery, it may be me to replace the atomizer head.
For sanitary reasons, frequently wash the detachable mouthpiece with warm water.
If you noce any humidity on the base of the mouthpiece, use a clean piece of paper to absorb it.
NOBACCO STREAM FUNCTIONS:
When aaching the atomizer STREAM will ask for coil type. Press power buon if the coil head is the same or
choose appropriate coil type (Ni-Ti-SS) for temperature control funcons with +.- buons.
Adjust WATT : In waage operaon long press + or – for one second. Screen will flash and allow you to adjust
WATT with +.- buons.
Temperature Control Mode (T.C. Mode): Long press power and + buons for 3 seconds to choose the T.C.
Mode according to coil head type (Ni-Ti-SS).
To adjust temperature long press + or - for one second. Screen will flash and allow you to adjust temperature
with +. - buons. To adjust power while in T.C. Mode long press power and - buon unl waage indicator starts
flashing. Adjust by pressing + or - buons.
Use:
Screw the atomizer onto the device without using
excessive force. Press 3* mes the power buon to
acvate the device and then inhale gently while
pressing the power buon of the device. Press 3* mes
the power buon to deacvate the device.
For peak performance, you are advised to press and
leave the power buon one (1) second prior starng
and ending your inhalaon.
The air flow control allows you to adjust the air intake
according to your preference.
CAUTION
When inhaling, Airflow control system must never be
fully closed in order for the atomizer to be able to
perform properly. Otherwise e-liquid may squirt in the
coil head causing malfuncon.
OLED Display Screen
Power-On/Off
Buon/Make Selecon
Micro USB Cable Plug Port
(+) Buon: Increase Temperature/Waage/Cycle Selecon
(-) Buon: Decrease Temperature/Waage/Cycle Selecon

DRY HIT PREVENTION
If there is insufficient e-liquid in the atomizer the device will lower the output. Refill the atomizer to avoid
malfuncon.
SCREEN ORIENTATION
Long press +,- buons for 3 second to change screen orientaon.
15 Seconds Cut Off
Device will cut off output if the power buon is pressed for more than 15 seconds for safety.
Short circuit/Atomizer Protecon
If the resistance of the atomizer is below 0.07Ω the LED light will blink solidly for 5 mes, the Ohms bar will
blink the device will not power on.
Check Atomizer
OLED screen will display CHECK ATOMIZER if no atomizer is aached or not properly connected or the
resistance is over 3.5Ω.
Over Discharge Protecon
NOBACCO STREAM will automacally power off if the baery cell is over discharged.
Overheat Protecon:
Screen will display TOO HOT if PCB is overheated
Low Voltage Warning-
The red LED and the screen baery indicator will blink 8 mes when the baery level is below 3.5V. Device will
power off automacally. Recharge your device to power on.
CHARGING
Connect the supplied USB cable to a wall charger or computer to charge the device.
CAUTION:
Power source must not exceed 2A/5V otherwise it may damage the baery cell or parts of the device. Warranty
is void in such an event.
DO NOT CHARGE THE DEVICE UNATTENDED.

Note: When STREAM is fully charged the LED will turn off.
510 ATOMIZER ADAPTOR
To aach an atomizer with diameter over 20mm securely screw the 510 atomizer adaptor on the device, using
the supplied tool and then your preferred atomizer on the adaptor.
Pass though charging System
- STREAM offer pass through charging operaon (charge and
vape).
- Using pass though may affect the baery lifespan of
STREAM.
POWER BUTTON COLOR CODE
When the power buon is pressed, or while the device is
charged, the color of the LED indicates the current level of
the baery cell.
Green, Yellow, Red
Precauons:
• In an event of drop, impact or crush examine that the product has no visible damage prior to use.
• Do not pierce or in any way damage the device housing. If the device housing is damaged in any way, directly
contact NOBACCO company.
• This device may include small parts, so please keep it away from children and/or pets.
• Do not immerse the device into any liquids or allow it to get wet.
• Do not carry or store the device with other sharp metal objects.
• Do not short circuit the negave (-) and posive (+) pole of the device.
• Do not use excessive force to connect the atomizer on the device
• Use only the dedicated for device parts and accessories to avoid any malfuncon.
• This product is not sold or marketed as a smoking cessaon device
• Please obey the local laws and/or regulaons pertaining to the use of vaping devices.
STORAGE INSTRUCTIONS:
• Keep the device away from children and minors.
• Keep the device away from very high or very low temperatures and/or humid environments.
• If you are not planning to use the device for a long period of me, fully charge the baery and disconnect the
atomizer. Repeat charging once every month.

SALES IS PROHIBITED TO UNDERAGE PEOPLE
This device is not intended to non-smokers and youth
Safety Instrucons:
If the product is used with e-liquid containing nicone.
The e-liquid is not intended for digeson. Do not allow the e-liquid to come in contact with skin. Keep your
device in accordance to common hygiene regulaons. Seek medical aenon if you feel nausea or experience
voming while using the device. E-liquids indented for electronic cigarees must not be combined with other
liquids or substances.
Do not use the product while driving. To avoid nicone overdose electronic cigarees should not be used
simultaneously with other nicone products (cigarees, cigars, gums, patches, nasal spray e.t.c.). Do not
dispose e-liquid in environment and sewage systems.
Warnings for risk groups:
If the product is used with e-liquid containing nicone.
Do not inhale the vapor if you are allergic to nicone or any other substance of the vapor.
If you experience any health issues or feel discomfort during the usage of electronic cigaree seek medical
advice.
Smoking or using electronic cigarees is not suggested during pregnancy or breaseeding.
Using electronic cigarees from an early age may cause serious health issues. Nicone can be very dangerous
or even lethal, if used or digested by children. Consult a doctor prior to use during pregnancy.
Contraindicaons:
If the product is used with e-liquid containing nicone.
Usage is not suggested to people who are hypersensive to nicone or other included contents, during
pregnancy, lactaon, or suffer from cardiopulmonary insufficiency.
Nicone must be used with cauon by people who have been diagnosed with: mild to severe liver disease,
severe kidney disease, cardiac disease, including angina pectoris, heart failure, high blood pressure, cardiac or
pulse arrhythmia, paents who have recently suffered from heart aack or stroke, hyperthyroidism, diabetes,
inflammaon of the esophagus, inflammaon of the stomach mucosa (gastris) , stomach ulcer, duodenal
ulcer, skin problems, long-term or chronicle throat issues, inhalaon difficules due to bronchis, emphysema
or asthma.
Side effects:
If the product is used with e-liquid containing nicone.
Possible side Effects, that might occur to some consumers due to the nicone toxicity, while using e-liquid
containing nicone, include, solely or in combinaon: nausea and voming, sleep disorders, head ache, chest
pain, gastrointesnal disorders, dizziness, terror, transpiraon, cardiac arrhythmia or tachycardia, paleness and

hypertension, spasms, fague, bradysphygmia, low blood pressure, respiratory or muscle paralysis. Side effects
may appear, typically, within 30 minutes to 2 hours aer oral exposure or may appear instantly aer nicone
inhalaon. Nicone is a highly addicve substance.
If you experience any possible side effect stop using nicone product and seek medical aenon or contact
your doctor.
If a child under age of 12 accidentally digests nicone product IMMEDIATELY seek medical aenon or
contact your doctor.
Poison Center phone number in Greece: (+30) 210 779 37777
Manufacturer:
Shenzhen Innokin Technology Co, Ltd
Building 6, XinXinTian Industrial park , Xinsha Road Shajing, Baoan District, Shenzhen, China P.R.C. 518104
Tel: 0086-755-2989-8770
Email: [email protected]
Contact affiliate:
ΝΟΒACCO S.A.
Address: 23 Tzavella St, Halandri, Greece, ZIP CODE 15231
Landline: (+30) 210 762 2020
E-mail: [email protected]
WARRANTY
This equipment has been tested and found to be free of defects in materials and workmanship that
result in failure during normal usage. This warranty is extended to the original end-user purchaser,
beginning at the me of retail purchase. Under this warranty, we will replace or repair, free of charge,
any defecve materials. This warranty does not cover misuse, unauthorized modificaons and external
uses such as acts of nature. This warranty does not cover normal wear and tear. In such a case, the
service department will inform you of the exact cost pertaining to the repair of your device and will
request your ap¬proval before proceeding to any further acon. For more informaon about the
warranty period, please visit the product’s official webpage at www.nobacco.world or ask your local
reseller.
NOBACCO COMPANY CANNOT BE HELD RESPONSIBLE FOR DAMAGES THAT MAY OCCUR DUE TO
INAPPROPRIATE USE OF THE DEVICE OR INCORRECT COMPLIANCE WITH THE PROCEDURES
DE¬SCRIBED IN THE USER MANUAL
No part of this guide may be reproduced, translated or transmied in any form or by any means
without the prior wrien permission of NOBACCO Company.
This manual suits for next models
1
Table of contents
Other Nobacco Electronic Cigarette manuals